Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.7 LAccepted-AOC D 16 OF HQ ADG P CHENNAI PLOT NO 97 SANTOSH NAGAR BALAJI NAGAR NEAR CURRENT OFFICE MEDCHAL MALKAJGIRI TELANGANA 500087 | MEDCHAL MALKAJGIRI | TELANGANA | 500087 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹96.4 L+₹6.4 L (7.13%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L2 | Rejected-Finance other than L1 bidder | |
| 3 | L3₹99.8 L+₹9.8 L (10.9%)Rejected-Finance | L3 | Rejected-Finance other than L1 bidder | |
| 4 | L4₹1.1 Cr+₹16.8 L (18.7%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-Finance other than L1 bidder | |
| 5 | L5₹1.1 Cr+₹19.0 L (21.1%)Rejected-Finance | L5 | Rejected-Finance other than L1 bidder |
Tender Value
₹99.6 L
EMD Value
₹1.7 L
Closing Date
18 Nov 2023, 6:00 pmClosed
CWE ARMY Secunderabad
Commander Works Engineers Mudfort, MES Office Complex Secunderabad-500 003
SPL REPAIR TO BLDG No P 5 P6 OTM ACCN OF NO 1 TRG BN F AOC CENTRE TO INCL REPLACEMENT OF AC SHEETS/MANGALORE TILES WITH GALVANISED SHEETS, REPAIR AND REPLACE OF WINDOWS, VENTILATIONS, BIRD PROOFING OF ROOF, REPLACEMENT OF ELECTRICAL WIRING AND
2023_MES_623093_1
CWE(S)/SOUTH/TOKEN/34 OF 2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH Secunderabad
As per NIT
7 documents required · 7 mandatory
₹1,000
GE SOUTH Secunderabad
₹1.7 L
Yes
16 Jan 2024
13 Oct 2023
25 Nov 2023
13 Oct 2023
18 Nov 2023
4 Nov 2023
Amount
Demolition of cement concrete in roof inc existing roof treatement (other than ground floor) and in any position, removing debris to a distance of n.exc 100M away from the bldg complete all as specified and directed..
M & L for 25 mm average thick PCC (1:2:4) Type B0 by using 12.50 mm graded stone aggregate as in roof where required over slabs and finishing the exposed surfaces fair even without using extra cement complete all as specified and directed.
M&L for removal of old treatment of any description and removing the debris roughening the surfaces of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M & L 10mm thick rendering in CM 1:4 using water proofing compound at the rate of 3% weight of cement over concrete surfaces complete all as specified and directed. ( Note : WPC measured and paid separately)
M&L priming the plastered roof surfaces with bitumenous primer @ 0.30 Kg per sqm and applying APP based polymeric membrane minimum weighing 3 Kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Wt not less than 150 gms/per Sqm) and on primed surface by forced application over apply bitumen base aluminium paint @ 0.20 Kg/Sqm complete all as specified.
Supply only water proofing compound
M & L cutting grooves in brick wall/roof slab of size 75mm wide 65mm deep and shapping to horizontal face of the groove with cement mortar 1:3 complete all as specified and directed.
Taking down rain water pipes of any description any pattern incl all fittings heads, shoes bends etc all as specified.
S&F PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls all as specified.
Dismanting asbests cement ( corrugated, semi-currugated etc.) sheets in roof covering complete all as specified and directed.
S & F prepainted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPA asin roof covering/cladding to wall fixed with self tapping screws as specified.
S&F pre painted gal valume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour haing tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws as specified
Dismantling framed wooden purlin/Rafter work of any description sectional area exc 40 Sqcm not other wise provided for, complete all as specified and directed.
S & F roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A.
M & L providing cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed.
M&L Preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat primer. all as specified & directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc all as specified and as directed. .
M & L for brick work with flyash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 all as specified and as directed.
Taking down cement or cement lime plastering on brick walls etc including racking out joints, hacking for key, scrabing down with water etc. complete all as specified and directed.
M & L for 15 mm thick in two coats (inner 10mm layer 1:6 and outer 5mm layer 1:4) rendering in Cement Mortar on fair faces of Brick works or Concrete surfaces and finishing even and fair and using water proofing compound for outer 5mm layer complete all as specified and directed incl scaffolding if necessary. Note : Patch work upto height 7.50m incl necessary scaffolding. (WPC will be measured and paid separately)
M & L for 10 mm thick rendering in Cement Mortar 1:6 on fair faces of Brick works or Concrete surfaces and finishing even and smooth without using extra cement. complete all as specified and directed.
M & L for 10 mm thick rendering in Cement Mortar 1:3 on fair faces of Brick works or Concrete surfaces in ceilings and finishing even and smooth without using extra cement. complete all as specified and directed. Note : Roof projection/sun shade portion upto ht 7.50m incl necessary scaffolding
S&F Hard drawn steel wire fabric cut to length, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia in reinforcement n exc 4kg per Sqm
M&L for two coats of cement base paint over a coat of primer on new surfaces of wall including preperation all as specified and as directed.
M&L for two coats of OBD over a coat of primer including preparation of new plastered surfaces of walls all as specified and directed
M&L for three coats of white wash including preparation of new plasted ceiling all as specified and directed
M&L Preparation of plastered or unplastered old decorated surfaces and applying two coat of white wash on ceiling surfaces.complete all as specified and directed.
M&L Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L Complete removal of existing treatment on walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for providing false ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mm and aluminium wall angle size 25x25x1.8 mm fixed to wall hanging from soffits\trusses\bracking using adjustable supporting hanger compressing of GI wire 4mm thick with locking clip.complete all as sepcified and directed by Engr-In-Charge.
M&L for Providing and fixing Non asbestos designer E-Board 4mm thick in ceiling fixed to snap grid as per manufacturers instructions complete all as sepcified and directed by Engr-In-Charge.
Taking down chowkat with frame (without taking off shutter from the frame) exc 1.50 Sqm each complete all as specified & directed.
Taking down shutter of any description not exc 1 Sqm each complete all as specified complete all as specified & directed.
Taking down shutter of any description exc 1 Sqm & n exc 2 Sqm each complete all as specified complete all as specified & directed.
M&L for plain cement concrete type C-1 1:3:6 (20mm graded aggregate) for setting hold fasts, steel windows all as specified and directed.
S&F bands, straps, supports or stays for rain watr, ventilating pipes including bolts if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasta, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles confirming to Fe-290 Gde E-165
M & L for 2nd class hard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints
M & L for preparation of new wood and wood based materials, like backs of chowkhats and tarred with tar or coal tar black paint, area tarred exc 0.1 sqm but n exc 0.5 sqm surface and complete all as specified.
M & L for treating small articles such as stop, covers, holdfasts, with tar or coal tar black paint area tarred n exc 0.1 sqm complete all as specified.
S&F for 35mm thick factory made plain framed paneled shutter of 2nd class HW (any Number of panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm th venered particle board with veneering on both face kiln seasoned & chemically treated complete all as specified & directed.
S & F 35mm thick 2nd class hard wood glazed skeleton door shutters open rebated and prepared to receive glass, gauze, etc (without sah bars) and divided into square with plain, rounded, chamfered, mitred complete all as specified & directed.
S & F 35mm thick 2nd class hard wood glazed skeleton windows shutters open rebated and prepared to receive glass, gauze, etc (with sash bars) and divided into square with plain, rounded, chamfered, mitred and rebated sash bars.complete all as specified & directed.
S & F 100mm butt hinges medium weight cold rolled mild steel complete all as specified & directed.
S & F Aluminium handle 150mm fabricated type complete all as specified & directed.
S & F Aluminium anodised barrel tower bolts 150mm of extrded section complete all as specified & directed.
S & F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
S&F 300 mm long MS helical door springs including roller plate complete all as specified & directed.
S& F for 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor
S &F for framed work such as grills, grating etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars(for windows); barred iron doors; ladders; framed balusters; walk ways; railings; framework of watertanks and similar work cnforming to Fe 290. Gde E-165
S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and avg width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed.
All as per item No 48 above but fixed in repairs complete all as specified & directed..
S & F 2nd class hardwod in fillets, square, rectanglar in section wrought, secrred with nails sectional area exc 3 sqcm and n exc 6 sqcm fixed in repairs.
S & F 2nd class hardwod in fillets, square, rectanglar in section wrought, secrred with nails sectional area exc 13 sqcm and n exc 25 sqcm fixed in repairs.
Hacking out old broken glass any description & size from wooden/steel window and removal of rubbish from work site as directed.
S & F 3mm th sheet glass ordinary quality and fixed with oil putty in square not exc 0.5 sqm in each pane complete all as specified & directed.
M & L for preparation of new wooden surface and applying 2 coats of synthetic enamel paint over one coat of pink primer over 10cm width or girth complete all as specified.
M & L for preparation of old wooden surface and applying two coats of synthetic enamel paint over 10cm width or girth complete all as specified.
Demolition of cement concrete(unreinforced) in ground floors and paving nexc 15 cm thickness (below and above ground level) complete all as specified & directed.
M&L cement concrete 40mm thick type B- 1, 1:2:4 (20mm graded agg) as in floor finishing cement concrete surface even and smoothwithout using extra cement ..
M&L forming 38mm wide construction joints Glass dividing strips, 3 mm thick complete
M&L for cutting hole in brick masonary/RCC for fixing rain water outlet pipe including finishing with PCC to match existing finishes all as specified and directed.
M&L for removing plants incl complete root in wall and roof, also repair and finish with PCC (1:3:4) finished to existing surface upto height of 7.5m all as specified and directed.
S&F 25mm Stainless steel curtain rods incl required nos of brackets complete all as sepcified and directed by Engr-In-Charge.
Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar
S&F 20-25 mm thick kota stone as in floors over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish and rounding chamfered edges where directed complete all as specified and diirected.
All as per item above but 20 to 25mm thick kota stone slab as in small wiidth in vertical surfaces like landings, risers,, treads, skirtings, dado, etc over and including 10mm thick pcking coat in cement mortar 1:4 complete all as specified and directed.
Mirror polishing on Kota stone/stone work where ever required to give high gloss finish complete all as specified and directed.
M&L for chequered cement concrete tiles with grey cement and pigments of size 300cmx300cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1:6 screed bed in flooring complete all as specified & directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M & L for Point wiring complete with two runs of 1.5 Sq mm copper conductor (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade confirming to IS- 694 drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc,including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches,sockets,fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw ,cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dollyetc. complete all as specified and as directed for one light point controlled by one switch. Note1: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth Note 2: The cost of cutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted in case of concealed wiring
All as per Sl item No 71 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No 71 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
M & L Submin wiring with 4 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 6 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB / main board including removing the esisting unserviceable submain wiring complete all as specified and directed. Note : 4 runs of 6 Sqmm, one run of earth wire of size 6sqmm and one run of PVC conduit will shall be measured as one unit lenght.
M & L Submin wiring with 2 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 6 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB / main board including removing the esisting unserviceable submain wiring complete all as specified and directed. Note : 2 runs of 6 Sqmm, one run of earth wire of size 6sqmm and one run of PVC conduit will shall be measured as one unit lenght.
M & L Submin wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB / main board including removing the esisting unserviceable submain wiring complete all as specified and directed. Note : 2 runs of 4 Sqmm, one run of earth wire of size 4sqmm and one run of PVC conduit will shall be measured as one unit lenght.
S & F Switch piano type single pole one way flush type 5 Amps capacity 230 volts.
Supply and fix switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 Volts complete all as specified.
Supply and fix socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts all as specified
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
Supply and fix switch socket combination flush type multipurpose 5 in 1, 6/16 Amps, 230 Volts complete all as specified.
S & F wall mounted Batten type, LED tube light 20 watt ,3 Feet with heat sink provided for efficient heat dissipation & integrated electronic driver complete with necessary fixing arrangements and connecting to the point wiring with necessary flexible copper conductor multistranded three core of suitable length & size from fitting to the ceiling rose complete all as specified & directed Make : Philips Model:Reserve plus or its its equivalent in wipro/Havells Cat part No LHEXAPP7TUNIW020
S & F wall mounted box type LED of 20 watt , extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with 2 Nos round blocks with necessary fixing arrangements and connecting to the point wiring with necessary flexible copper conductor multistranded three core of suitable length & size from fitting to the ceiling rose complete all as specified & directed. Make - Havells Cat part No LHEXBLP7PNIW018
S & F Security Lights of 1x30 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified & directed. Make - Havells Cat part No LHEXAYP7PN6K030
M & L bracket made out of GI pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and directed by Engg-in-Charge
S&F sheet metal enclosure vertical type MCB DB TPN 4 way double door with 160 Amps rated bus bar 415 volts suitable for and provision of 63 Amps TPN MCCB 16 KA as incommer and 12 Outgoing SP MCB's with magnetic locking system complete all as specified. Note for item No 86, 87 & 88 : MCB's, MCCB's Shall be measured and paid seperately, all as specified and directed.
S and F sheet metal enclosure MCB DB TPN 4 way with 160 Amps rated bus bar 440 Volts double door with magnetic locking system complete all as specified.
S and F sheet metal enclosure MCB DB SPN 8 way with 100 Amps rated bus bar 240 Volts double door with magnetic locking system complete all as specified.
S& F Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) , SPN 32 A and current carrying capacity in the MCB DB complete with connection testing and commissioning
S & F MCB SPN 230V suitable for fixing on MCB DB of capacity 40 Amps complete all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP current carrying capacity in the DB complete with connection testing and commissioning
MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth earth lead 4 mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe med grade 15mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI pipe med grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of SSR Part-I and connection to earth test point all as specified incl testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4 mm size and protection pipe of 15 mm bore GI light grade.
Supply,fix ,test and commissioning of ceiling fans complete regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply,fix ,test and commissioning of LED adore lamp 9 Watts min 85 lumens with B22 base cap, WW 3 star lamp 3000K all as per Cat No.LHLDEUEEMC8R009 OF HAVELLS or its euivalent for bed side/study lamps complete
Supply & Fix Telephone socket modular type modular type RJ11 with shutter all as per cat No.573426 of Legrand or techno-coomercially equivalent of other specified makes
Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles etc. for TV/Telephone socket
Supply and fix TV CO-Axial socket outlet modular type all as per Cat No.5736 25 of Legrand or techno-coomercially equivalent of other specified makes
SAI RUPA CONSTRUCTIONS
BEEGEE DESIGN SYSTEMS
STANDARD AGENCIES
K CHANDRAPAL REDDY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .