Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAdmitted-Finance | ₹7.3 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AASTHA CONTRACTS INDIA PVT LTD L1 |
|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil | 888 | Cum | 140 ₹1,24,320 Lowest |
| 2.00 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil | 222 | Cum | 70 ₹15,540 Lowest |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 830 | Cum | 175 ₹1,45,250 Lowest |
| 4.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 76 | Cum | 1,560 ₹1,18,560 Lowest |
| 5.00 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | 50 | MTR | 290 ₹14,500 Lowest |
| 6.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 95 | Cum | 4,630 ₹4,39,850 Lowest |
| 7.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 95 | SQM | 490 ₹46,550 Lowest |
| 8.00 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete | 242 | SQM | 225 ₹54,450 Lowest |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers | 325 | SQM | 440 ₹1,43,000 Lowest |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts | 29 | SQM | 580 ₹16,820 Lowest |
Tender Value
Refer Docs
EMD Value
₹8.8 L
Closing Date
8 Nov 2021, 3:00 pmClosed
PROJECT MANAGER
PROJECT MANAGER, UWD, GGSIPU
Construction of Atal incubation centre(G PLUS 3), Dwarka Campus, GGSIPU
2021_GGSIP_210257_1
10/PM/UWD-P/2021-22
Open Tender
Construction Works
Works
180 days
PROJECT MANAGER, UWD GGSIPU
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹8.8 L
9 Nov 2021
27 Oct 2021
8 Nov 2021
27 Oct 2021
8 Nov 2021
27 Oct 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walls Under 20 cms wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing, fabricating transportation,assembling and erecation in position of steel plate for Structural steel member like columns, built up beems etc. using structural steel/section of grade E-350 A, Normalised/conforming to IS-2062 with latest amendment, to the required profile and shape as per the drawing and specification. This item includes adequate temporary welding (using automatic submerged arc welding and gas metal are (MIG) welding wherever specified) & all labour, tools, plants & equipment’s and operation etc. required to complete the job as per drawing and specification Every precaution to be taken to prevent rusting of sections. This item also includes all testes of material and welded fabricated parts as per specification and direction of Engineerin- charge. Temporary bolts and nuts (Grade 4.6) to be used during assembling shell be removed before site reation. All site erection bolts shall be HSFG type only. Item include ti cost of steel shot blasting on external surface using abrasive charge conforming to SA 2.5 (ISO 8501-1988), and appliying epoxy based steel primer of approved brand etc. complete as per technical specification, epoxy of manufacture. All work executed as per approval drawing, specification and as per direction of Engineer-in-charge.
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work Area of slab upto 0.50 sqm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 800x800 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4+B199 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 1729
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal outer dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 18.50.1 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 250 mm diameter S.W. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 250 mm dia. R.C.C. pipe
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. Red sand stone
Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800- 1984 and IS:801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
Making trench less under ground hole across the roads/cement concrete pathway at a depth of about 1 mtr. by means of manual augor and connecting pipes to suit the pipe/cable of size up to 150/200 mm dia. i/c making excavation on both side of road/pathway for making trenchless hole and refilling the same with excavated soil after laying pipe & cable through trenchless hole. watering. dressing complete as required as per instruction of Engineer-incharge. (Cost of laying of cable & pipe is not included in this item)
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth)
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charges
Grouting the joints of flooring tiles having joints of 5 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing cylindrical lock for toilet door with push button locking mechanism (keyless type) of approved quality with necessary screws etc. complete.
Providing & Fixing Wash basin – Vitreous china counter top basin with CP brass pressmatic faucet of approved make.. as approved by Engineer-in-charge.
Providing Drip seal joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter
Providing and fixing glazing in UPVC window complete as per the architectural drawings and the directions of engineer-in-charge. With Toughened glass panes of 6 mm thickness
Providing and fixing Roller blinds of make-Vista with pelmet and chain draive mechanism of approved pattern , including fixing etc. complete as per direction of Engineer-in-Charge. (The rates are inclusive of all the operation, fittings and materials.)
Providing and fixing S.S. Health faucet with flexible tube upto 1.5 metre long with hook etc complete as per direction of engineer incharge.
Providing and fixing CP grating of approved quality and colour. 100 mm nominal dia
Providing and fixing liquid soap dispenser-press type of standard shape with bracket of the same materials with snap fittings of approved quality and colour.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Colour Anodised aluminium (shampaign coiour according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) colour Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125mm
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 75 mm each
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick
Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete.
Providing and fixing steel roller for uPVC sliding door with necessary screws etc. complete.
Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete.
Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete.
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square
Providing and fixing in all exterior face panels breathable vapour barrier underneath the cement fiber board as per National Building Code 2009 complete as per direction of Engineer-in-charge.
Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000, category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners@ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge oflength varying from 25 to 45 mm and internal face 12.5mm thick gypsum plaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately).
Providing and fixing external wall cladding tiles of size 150x3000x8 mm square edge having density >1200kg/cum,thickness tolerance +/- .5 mm modulas of repture >9 Mpa,water absorption<30%,water permeability -NO DROP modulas of repture >9 Mpa,water absorption<30%,water permeability -NO DROP LET PASSES,Thermal conductivity-.0872W/m-K AT mean temperature of 25 degree C. for use in cladding,façade,ceiling,soffit lining,gates,fencings etc.resistent to warm water,soak dry resistant,heat rain resistant with all necessary fixing arrangement and as per the direction of engineer in charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed withwater proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm diameter
Single tee with door 110x110x110 mm
Providing and fixing two hour fire rated partition comprising of Boarding with Double layer tapered edge Gypsum Board with GreenPro certification by CII. Partition includes boarding with one layer of 13mm thick Multistop3 or equivalent Gypsum boards having density >950 Kg/cum (complying to requirements of D, F, I, R Categories as per BSEN 520) which is engineered to take Fire Resistance, Sound Insulation & Impact Resistance is screw fixed vertically on one layer of 12.5mm Fire Bloc/ Fire resistant Gypsum Board conforming to IS 2095 Part I on either side of the wall Studs with 25mm & 38mm long Drywall Screws at 300mm centres. The screw fixing to the metal framing at the periphery, openings and cut edges should be at 150mm centres. The horizontal & vertical joints of the on both sides of the metal framework must be staggered to avoid through joints. 50mm thick Insulation of 48kg/m3 and acoustic sealant of approved brands. At the location of door frame in dry wall system, wooden member shall be fixed of required size as per manufacturer's specification. Extra support for provision of hanging any Electrical Fixtures/ Office Cabinets to be provided wherever required in the Drywall as per recommendation of Engg In Charge and which shall be paid in relevant tender item. The junction of the partition with masonry & all penetration through the partition has to be treated with fire and acoustic sealant as per approved makes.
Wiring for light point / fan point / exhaust fan point / call bell point / with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed STEEL conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. 2 x 2.5 Sq.mm.+ 1 x 2.5 Sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. 2 x 4.0 Sq.mm. + 1 x 4.0 Sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. 2 X 10 sq. mm + 1 X 10 sq. mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. 2 X 16 sq. mm + 1 X 16 sq. mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. 4 X 10 sq. mm + 2 X 10 sq. mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. 4 X 16 sq. mm + 2 X 16 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 2X1.5 Sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3X2.5 Sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3X4.0 Sq. mm
Supplying and drawing following pair 0.5 mm FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supply & fixing of following size of steel conduit along with accessories in surface / recess including painting incase of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required. 20 mm dia
Supply & fixing of following size of steel conduit along with accessories in surface / recess including painting incase of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required. 25 mm dia
Supply & fixing of following size of steel conduit along with accessories in surface / recess including painting incase of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required. 32 mm dia
Supply & fixing of following size of steel conduit along with accessories in surface / recess including painting incase of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required. 40mm dia
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supply and fixing of following modular switch / socket on existing modular plate and switch box including connections but excluding modular plates etc. as required 5/6 Amp switch
Supply and fixing of following modular switch / socket on existing modular plate and switch box including connections but excluding modular plates etc. as required 15/16 Amp switch
Supply and fixing of following modular switch / socket on existing modular plate and switch box including connections but excluding modular plates etc. as required 3 pin 5/6 Amp socket outlet
Supply and fixing of following modular switch / socket on existing modular plate and switch box including connections but excluding modular plates etc. as required 6 pin 15/16 amp socket outlet
Supply and fixing of following modular switch / socket on existing modular plate and switch box including connections but excluding modular plates etc. as required Telephone socket outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of following size / modules GI box along with modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mmX75mm)
Supplying and fixing of following size / modules GI box along with modular base & cover plate for modular switches in recess etc. as required 3 Module (100mmX75mm)
Supplying and fixing of following size / modules GI box along with modular base & cover plate for modular switches in recess etc. as required 4 Module (125mmX75mm)
Supplying and fixing of following size / modules GI box along with modular base & cover plate for modular switches in recess etc. as required 6 Module (200mmX75mm)
Supplying and fixing of following size / modules GI box along with modular base & cover plate for modular switches in recess etc. as required 12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface / recessed steel / PVC conduit as required 1 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface / recessed steel / PVC conduit as required 2 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface / recessed steel / PVC conduit as required 3 run of cable
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 2 + 12 way/14 way, Double door
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 12 way (4 + 36), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SINGLE POLE
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DOUBLE POLE
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63AMP
Supplying and fixing 25 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 25 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and installing following size of perforated pre-painted M.S. cable tray with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders etc. as required. 300mm x 50mm x 1.6mm thickness.
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm (50mm)
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Making trench less under ground hole across the roads/cement concrete pathway at a depth of about 1 mtr. by means of manual augor and connecting pipes to suit the pipe/cable of size up to 180 mm dia. i/c making excavation on both side of road/pathway for making trenchless hole and refilling the same with excavated soil after laying pipe & cable through trenchless hole. watering. dressing complete as required as per instruction of Engineer-incharge. (Cost of laying of cable & pipe is not included in this item)
Supplying, installation, testing & Commissioning of of XLPE insulated PVC sheathed ( Heavy duty ) armored electric cable with aluminum conductor for working voltage of 1100 volts confirming to IS : 7098 ( Part- I ). 3½ X 25 sq. mm
Supplying, installation, testing & Commissioning of of XLPE insulated PVC sheathed ( Heavy duty ) armored electric cable with aluminum conductor for working voltage of 1100 volts confirming to IS : 7098 ( Part- I ). 3½ X 35 sq. mm
Supplying, installation, testing & Commissioning of of XLPE insulated PVC sheathed ( Heavy duty ) armored electric cable with aluminum conductor for working voltage of 1100 volts confirming to IS : 7098 ( Part- I ). 3½ X 95 sq. mm
Supplying, installation, testing & Commissioning of of XLPE insulated PVC sheathed ( Heavy duty ) armored electric cable with aluminum conductor for working voltage of 1100 volts confirming to IS : 7098 ( Part- I ). 3½C x 150 sq. mm
Supplying, installation, testing & Commissioning of of Bulkhead Luminaire 6W LED Complete in all respect.
Supplying, installation, testing & Commissioning of recessed type 30 W to 36W Full window glarefree opal Diffuser LED Panel of size 595mmX595mm suitable for existing calcium silicate false ceiling with MS Powder coated CRCA Housing, the total lumen of LED fitting should be 3600 or above in Cool day Light(5700K to 6500K), Power factor>0.95, CRI >80, LED, Complete with all accessories including connections etc as required and as per direction of Engineer-in-charge.
Supplying, installation, testing & Commissioning of recessed type 15 W Round Downlighter with pressure die-cast aluminium housing and glare free opal diffuser, ceiling cutout 138 mm suitable for existing false ceiling, the total lumen of LED fitting should be 1400 or above in Cool day Light(5700K to 6500K), Power factor>0.95, CRI>80, LED Lamp Complete with all accessories including connections etc as required and as per direction of Engineer-in-charge.
Supplying, installation, testing & Commissioning of Surface Mounted Fitting 1 x18 W LED complete in all respect.
Supplying, installation, testing & Commissioning of Surface Mounted fitting 2 x18 W LED complete in all respect.
Supplying, installation, testing & Commissioning of A.C. CEILING FAN 48" (1200MM) SWEEP,
Supply, Installation, Testing and Commissioning of Variable refrigerant volume/ Variable refrigerant flow modular type air- conditioning system suitable for cooling and heating by using inverter Driven/ digital scroll compressors complete with indoor and outdoor units with individual controller and with fittings etc., as per quantity given below i/c full charging of R-410A refrigerant gas complete as per specifications & direction of Engineer-in-charge and having following items. Outdoor units. Outdoor units of 22 HP suitable for operating with R-410A refrigerant as per specification attached.Total 88 HP.
Indoor units Supply ,installation , testing and commissioning of Indoor units with compact DX cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamically balanced and designed for silent operation, the filters shall be synthetic washable media type arranged for convenient cleaning and replacement as per the given capacity range.HIGH Wall Type 1.6 TR ( Nominal Capacity)
Indoor units Supply ,installation , testing and commissioning of Indoor units with compact DX cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamically balanced and designed for silent operation, the filters shall be synthetic washable media type arranged for convenient cleaning and replacement as per the given capacity range.HIGH Wall Type Y-joints / Refnet
Indoor units Supply ,installation , testing and commissioning of Indoor units with compact DX cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamically balanced and designed for silent operation, the filters shall be synthetic washable media type arranged for convenient cleaning and replacement as per the given capacity range.HIGH Wall Type Outdoor Refnet
Indoor units Supply ,installation , testing and commissioning of Indoor units with compact DX cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamically balanced and designed for silent operation, the filters shall be synthetic washable media type arranged for convenient cleaning and replacement as per the given capacity range.HIGH Wall Type Corded Remote controls.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 6.4 mm dia with 13mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 9.53 mm dia with 13mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 12.70 mm dia with 13mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 15.86 mm dia with 19mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 19.1 mm dia with 19mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 22.1 mm dia with 19mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 28.5 mm dia with 19mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 34.9 mm dia with 19mm thick nitrile rubber insulation.
Supplying & Installation of interconnecting following sizes of refrigerant copper pipe insulated with closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly fixed/ supported with suitable size of clamp/ M.S. hanger and all external piping shall run in existing cable tray etc. as reqd. 41.3 mm dia with 19mm thick nitrile rubber insulation.
Providing & fixing of Rigid PVC Piping complete with fittings, supports as per specifications and duly insulated with 9mm thickness of closed cell nitrile rubber insulation etc. complete as per direction of Engineer-in-charge & specifications enclosed as reqd. 25 mm dia.
Providing & fixing of control wiring with following sizes of copper cable between indoor and outdoor units directly on surface of wall/ existing channel etc. as reqd. 2 x 1.5 sq. mm
Providing and fixing of 18 SWG perforated cable tray of approximate size for running outdoor refrigerant pipes. Cable tray should be properly clamped and hang with all necessary accessories as required. 40mm x 300mm x 40mm
Supply & Installation of suitable size of stand made out of angle iron frame work to be suitable to bear the overall weight of the outdoor Unit, duly painted including grouting the legs in CC foundation etc. as reuqired.
Supplying and installation of ISI mark heavy duty Exhaust fan of 300 mm sweep 230 volt 50 HZ 1400 RPM complete with blade, leg guards, rubber pads, louver etc. in the existing opening including connections, testing etc. as required.
Supplying and installation of ISI mark heavy duty fresh air fan of 300 mm sweep 230 volt 50 HZ 1400 RPM complete with blade, leg guards, rubber pads,with louver etc. in the existing opening including connections, testing etc. as required.
Supplying, installation, testing & Commissioning of 35Watt uniflood integral flood with driver inside a DPC housingh it is highly efficient, reliable and sturdy compared to similar LED. Halogen and metal halide flood light.
Supply, installation, testing and commissioning of horizontal single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC.,etc as required and as per direction of Engineer-in-charge. Capacity 900 LPM at 3.5 Kg/cm2 (Roof Fire Pump).
Supplying and fixing Hose box (Double Door) (750mm x 600mm x 250mm) 16 gauge suitable for 2 no. 15mtr. Hose and 1 no short branch pipe. Complete in all respect. Including nut and bolts etc,Old dismantling M.S.hose box etc as required and as per direction of Engineer-in-charge.
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Stainless Steel cap and chain as required , Single headed Stainless steel and as per direction of Engineer-in-charge.
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585,20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 Mtrs and as per direction of Engineer-in-charge.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Stainless Steel (Grade 304) : and as per direction of Engineer-in-charge.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) and as per direction of Engineer-in-charge.
Providing laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/3589 (all pipes shall be ISI marked and of makes specified in the specifications) i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including excavation & providing cement concrete blocks as supports and anti-corrosive treatment to burried pipes by wrapping & coating with 4 mm thk. (OR 2 COATS of 2mm thick tape) anticorrosion tape along with two coat of black japan primer for under-ground pipe including digging and backfilling upto 1.0 mtr. below from G.L.for external work as per IS-909 (Specification for Underground Fire Hydrant cannection with exixsting fire line.nd as per direction of Engineer-in-charge. 100 nominal bore (class C)
Supply and installation of Butterfly Valves of rating PN 1.6 with mating flanges generally as specified all complete.nd as per direction of Engineer-in-charge. 100 nominal bore
Supply and installation of Butterfly Valves of rating PN 1.6 with mating flanges generally as specified all complete.nd as per direction of Engineer-in-charge. 80 nominal bore
Providing and laying cast iron non-return valve of rating PN 1.6 dule ISI marked with flanges generally as specified completend as per direction of Engineer-in-charge. 100 nominal bore
Providing and laying cast iron non-return valve of rating PN 1.6 dule ISI marked with flanges generally as specified completend as per direction of Engineer-in-charge. 80 nominal bore
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Note:Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 100 mm nominal bore (class C)
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Note:Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 80 mm nominal bore (class C)
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Note:Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 65 mm nominal bore (class C)
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Note:Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 50 mm nominal bore (class C)
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Note:Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 40 mm nominal bore (class C)
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Note:Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 32 mm nominal bore (class C)
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Note:Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 25 mm nominal bore (class C)
Supply, installation, testing and commissioning of 100 mm dia Installation Control Valve inclusive of 2 nos 100 mm dia Butterfly Valve, strainer, Alarm Valve with Water Motor Gong, Pressure Gauges, Test Lines with Ball Valves with necessary GI (H) piping with threaded fittings of required sizes complete
Providing, fixing, testing and commissioning of quick response 15 mm dia. gunmetal quartz bulb type sprinkler head to operate at 68 degree centigrade Pendent type
Supplying, installing, testing and commissioning 0 to 12 Kg/ cm2 ON/OFF pressure switch in delivery line of pump along with control wiring for auto starting and auto stopping of hydrant and jockey pumps.
Supplying and fixing of (Stored Pressure Type) fire extinguishers ABC powder type capacity of 6Kg duly ISI marked conforming to IS 15686:2006, with IS 14609, ISI marked complete with squeeze grip release valve,discharge pipe,locking arrangement, pressure gauge,operation manual and bracket. Operating Temperature:-10ºC to +55° C.as required and as per direction of engineer-in-charge.
Supply, installation, testing and commissioning of ABB make 630A , 4P , 36KA , with M/P LSI Release,ABB make 630A , 4P , T5 Extended Rotary handle,ABB make 630A , 4P , T5 Spreader Terminal, For Retrofitting With New 600A,4pole MCCB complete with fitting The new 630A,4pole MCCB Complete Following Scope of Work :- 1. Installation and Retrofitting of Bus-Bar With Links. 2. Retro Fitting the 630A,4pole MCCB. 3. Tightening the Bus-Bar with change-over links Complete with commissioning and testing etc. 4. Material Inclusive :- a) (50x50x12mm) x1 - RYB - Incomer + Outgoing + b) Bus-Bar Sleeve c) Hardware - Nut n Bolts in Existing L.T panel in Sub-sation
Supply installation testing and commissioning of 13 passenger (884 KG ) PMSM gearless MRL lift car enclosure in stainless steel hair line finish with three side glass mirror having contract speed of 1MPS in the lifts shaft as per deatil specification as under :- Speed - 1.75 MPS Floors-Ground+3 Travel - 15 Meters (appx) Stops & Opening - 4 (all on one side) Controller -AC variable voltage & variable frequency(V3F) Operation -simplex full collective with and without attendant gear less drive & machine room less Power - 415 ± 15% V , 3Phase, 50Hz AC Car Finish - Internal finish Stainless steel in Vandal Proof Finish Type of doors Car Entrance - Center Opening sliding Stainless steel doors in Vandal Proof Finish Landing Doors - Center Opening sliding Stainless steel doors in Vandal Proof Finish Door Operation - Automatic and Multi Ray Electronic Door Detector System Signals Combined Luminous hall button with seven segment digital hall position indicators at all floors Car operation panel with luminous floor button in car Seven segment digital car position indicator in car Battery operator alarm bell and emergency light Fireman's Switch Overload warning device Automatic rescue devise Voice Synthesizer Interface for BMS and Access Control Complete with in all respect with providing and fixing guide rails, minor building works, scaffolding, putting into operation and final testing etc as requiredand as per direction of engineer-in-charge. Overload warning device Automatic rescue devise Voice Synthesizer Complete with in all respect with providing and fixing guide rails, minor building works, scaffolding, putting into operation and final testing etc as requiredand as per direction of engineer-in-charge.
Supply, Installation, Testing & Commissioning of Microprocessor based EN listed 2 loop expandable upto 4 loops fire alarm control panel fully networkable with each loop capable of taking 127 devices, 1/4 VGA display character alpha-numeric liquid crystal display. The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have an option of second CPU with hot redundancy as incase of faliure of one CPU the other (redundant) CPU should take over fully. The panel shall have second power supply module/card as redundant power supply . The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. and as per direction of engineer-in-charge.
Supply, Installation, Testing & Commissioning of Repeater Panel (LCD indicator panel) with 80 characters alpha numeric LCD display connected with Main Fire Alarm panel complete as required and as per direction of engineer-in-charge.
Supply, Installation, Testing & Commissioning of plug in type intellignet photo electric addressable analog smoke detector with decentralise with inbuilt fault isolator including cost of base plate, outlet box for fixing of detector base where required, mounting accessories etc. complete required. and as per direction of engineer-in-charge.
Supply, Installation, Testing & Commissioning of Addressable type Intelligent Heat Detector having inbuilt fault isolator of rate of rise cum fixed temperature analog including the cost of base plate, outlet box fixing of detector base where required , mounting accessories etc. complete as required. and as per direction of engineer-in-charge.
Supply, Installation, Testing & Commissioning of dust and vermin protected Addressable Manual Call Point with reset lock to inititae the audio alaram system complete as required. and as per direction of engineer-in-charge.
Supply, Installation, Testing & Commissioning of Addressable wall/ceiling mounting Hooter (sound output of minimum 90 db) cum strobe(strength of light 110 cd) & suitable to PA system also complete as required. and as per direction of engineer-in-charge.
Supply Installation Testing and Commissioning of 4 zone IP based, digital Voice Alarm controller expandable upto 90 zones. The voice alarm controller should be able to connect directly over Ethernet. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. The Voice alarm controller should have minimum 125 priorities with time schedule broadcasts and should have its own PTT microphone with the capability of amplifier redundancy and eight trigger inputs and outputs.and as per direction of engineer-in-charge.
Supply Installation Testing and Commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection.and as per direction of engineer-in-charge.
Supply Installation Testing and Commissioning of 6W Ceiling/wall Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W.and as per direction of engineer-in-charge.
Supplying and Drawing of following size of FR PVC Insulated Copper Conductor, two core cable in the sorface/recessed steel/ PVC conduit as required for FAS and PA system.and as per direction of engineer-in-charge.
Supply Installation Testing and Commissioning of sign board by new LED exit signage double side with MS powder quoted cabinet with suitable size MS suspension road including trickle and boost charging and indication for battery mode & charging and suitable operation on 230 volt 50 Hz AC and 6 volt DC including 6 V 4 Ah battery and as per direction of engineer-in-charge.
Supplying and Installation, testing and commissioning of 15KVA online UPS with ATS miminum 30 min battery back up three phase (3 Phase) input and Three phase output including distrubution panel and connections etc. as required and as per direction of Engineer-in-Charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .