| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-Finance | ₹2.9 L | L1 | Accepted-Finance found in order |
| 2 | L2₹3.0 LAccepted-Finance | ₹3.0 L | L2 | Accepted-Finance found in order |
| 3 | L3₹4.2 LAccepted-Finance | ₹4.2 L | L3 | Accepted-Finance found in order |
| 4 | L4₹4.4 LAccepted-Finance | ₹4.4 L | L4 | Accepted-Finance found in order |
Tender Value
₹50 L
EMD Value
₹50,000
Closing Date
15 May 2026, 3:00 pmClosed
Executive Engineer STD bijbehara
Hanjipora Bijbehara
Stage Contract for maintenance of 33/11 KV Receiving stations along with their 33KV Lines falling under the jurisdiction of Sub Transmission Division Bijbehara for the Year 2026-27
2026_PDD_309126_1
STB/12 of 2025-26 dt. 30.04.2026
Open Tender
Electrical and Maintenance Works
Turn-key
120 days
STD Bijbehara
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Executive Engineer STD bijbehara
₹50,000
22 May 2026
30 Apr 2026
16 May 2026
30 Apr 2026
15 May 2026
30 Apr 2026
30 Apr 2026 - 14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantalling of Switchgear System of 33 KV C&R Panel | 1 | No | 100 | ₹100 |
| 2 | Dismantalling of Switchgear System of 33 KV VCB Panel | 1 | No | 101 | ₹101 |
| 3 | Dismantalling of Switchgear System of 11KV VCB Panel | 1 | No | 102 | ₹102 |
| 4 | Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 33 KV C&R Panel | 1 | No | 104 | ₹104 |
| 5 | Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 33KV VCB breaker | 1 | No | 105 | ₹105 |
| 6 | Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 11KV VCB Panel | 1 | No | 100 | ₹100 |
| 7 | Fixing,installation, testing & commissioning,testing of fresh Numerical/Digital/electromagnetic Relays by way of Replacement of Damaged/Burnt already installed in panel.(including fabrication of slot in the pannel if required) | 1 | No | 102 | ₹102 |
| 8 | Fixing,installing,commissioning,testing of fresh Master tripping relay.(including fabrication of slot in the pannel if required) | 1 | No | 104 | ₹104 |
| 9 | Rectification ,setting right the electrical section (Panel wiring) of 11KV VCB Panel including replacement of damaged parts like Rotor selector switch,TNC switch etc excluding Relay & Motor | 1 | No | 105 | ₹105 |
| 10 | Rectification,Re-Alignment,setting right the mechnical section of 11KV Breakers which includes replacement of damaged parts excluding Vacuum interrupter | 1 | No | 106 | ₹106 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.77 MB
Tendernotice_2.pdf
PDF • 2.21 MB
NIT12StageMaintt.pdf
Tender Documents • 0.75 MB
SBD12StageMaintt.pdf
Tender Documents • 2.19 MB
BOQNIT12StageExecution.xls
Tender Documents • 0.40 MB
SDVcombine.pdf
Other Document • 15.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].