Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹32.1 L+₹1.7 L (5.43%)Rejected-Finance B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not being the lowest | |
| 3 | L3₹36.5 L+₹6.1 L (19.9%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not being the lowest | |
| 4 | L4₹36.8 L+₹6.3 L (20.8%)Rejected-Finance | L4 | Rejected-Finance Not being the lowest | |
| 5 | L5₹37.1 L+₹6.6 L (21.6%)Rejected-Finance | L5 | Rejected-Finance Not being the lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Jan 2020, 6:00 pmClosed
Shri Rajiv Ranjan, IDSE
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR/MAINT OF DG SETS, BOOM BARRIERS, AMF PANEL, HANGER MOTOR AND CONNECTED ITEMS AT INS UTKROSH IN THE AREA OF AGE E/M NO II UNDER GE MINNIEBAY, PORT BLAIR(8817/E8)
2019_MES_304882_1
8817 GE MB PB
Open Tender
Civil Works
Item Rate
180 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE, Minniebay, Junglighat (PO), Port Blair -744103
₹70,000
Yes
25 Jan 2020
9 Dec 2019
9 Jan 2020
9 Dec 2019
7 Jan 2020
24 Dec 2019
Amount
Supply & Fix in repairs Low oil pressure transducer of 62.5/82.5/160 / 200 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed.
Supply & Fix in repairs Low lub oil pressure safety suitable for 62.5/82.5/160 /200 KVA DG set as per existing make and model and connecting with DG set system all as specified and directed.
Supply & Fix in repairs High water temperature trip safety suitable for 160 /200 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed.
Supply & Fix in repairs harness wiring suitable for 62.5/82.5/160 / 200 / DG set as per existing make and model and connecting with DG set operating system complete all as specified and directed.
Supply & Fix in repair shutdown valve suitable for 125/160 / 200 KVA DG set as per existing make and model complete all as specified and directed.
Supply and fix in replacement of magnetic pick up of 62.5/82.5/125/ 160 / 200 KVA DG set as per existing make and model complete all as specified and directed.
Supply and fix in replacement AVR unit as per existing make and model ,Suitable for DG set 62.5 / 82.5 / 125 KVA including connecting with alternator and control panel circuits, starting and testing complete all as specified and directed.
Supply and fix in replacement AVR unit as per existing make and model ,Suitable for DG set 160 / 200 / 250 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed.
Supply and fixing in repairs rotating rectifier assembly as per existing make and model, suitable for DG set 160 / 200 / 250 KVA complete all as specified and directed.
Supply and fixing in repairs rotating rectifier assembly as per existing make and model suitable for Cummins DG set 62.5/ 82.5 / 125 KVA complete all as directed at site.
M & L for B check maintenance in 25 KVA Kirloskar / Cummins/ Crompton greaves DG set including the replacement of lub oil, oil & fuel filters, B check all as specified by the manufacturer and directed by Engineer-in-charge. ( Note -Engine oil will be measured and paid separately)
M & L for B check maintenance in 62.5 KVA Kirloskar / Cummins/ Crompton greaves DG set including the replacement of lub oil, oil & fuel filters, B check all as specified by the manufacturer and directed by Engineer-in-charge ( Note -Engine oil will be measured and paid separately)
M & L for B check maintenance in 82.5 KVA Kirloskar / Cummins/ Crompton greaves DG set including the replacement of lub oil, oil & fuel filters, B check all as specified by the manufacturer and directed by Engineer-in-charge. ( Note -Engine oil will be measured and paid separately)
M & L for B check maintenance in 125 KVA Kirloskar / Cummins/ Crompton greaves DG set including the replacement of lub oil, oil & fuel filters, B check all as specified by the manufacturer and directed by Engineer-in-charge. ( Note -Engine oil will be measured and paid separately)
M & L for B check maintenance in 160 KVA Kirloskar / Cummins/ Crompton greaves DG set including the replacement of lub oil, oil & fuel filters, B check all as specified by the manufacturer and directed by Engineer-in-charge. ( Note -Engine oil will be measured and paid separately)
M & L for B check maintenance in 200 / 250 KVA Kirloskar / Cummins/ Crompton greaves DG set including the replacement of lub oil, oil & fuel filters, B check all as specified by the manufacturer and directed by Engineer-in-charge. ( Note -Engine oil will be measured and paid separately)
M & L for B check maintenance of 156 HP drainage pump make Kirloskar including the replacement of lub oil, oil & fuel filters, B check all as specified by the manufacturer and directed by Engineer-in-charge. ( Note -Engine oil will be measured and paid separately)
M & L for repair and reconditioning of battery charge alternator 24 V DC cummins make including taking out the defective alternator from 82.5 / 160 KVA / 200 / 250 KVA / capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge.
M & L for repair and reconditioning of battery charge alternator 12 V DC cummins make including taking out the defective alternator from 25 / 62.5 KVA / 82.5 KVA / capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge.
Supply and filling coolant for radiator suitable for DG set 125/160/200KVA of Make- Cummins/ Cotton greaves / Kirloskar under part no. 3167215, all as per manufacturers recommendations and directed by Engineer in Charge at site.
Supply and replace engine oil from engine oil sump with suitable grade oil SAE-20W40 complete all as directed by Engr-in-Charge.
Supply & fix inreplacement asbestos rope 12 mm dia for wrapping the exhaust pipe of DG set all as directed by Engineer-in-charge.
Supply and fix in replacement of Air filter of 25/62.5/125 KVA DG set of Make- Cummins/ Cottton greaves/ Kirloskar part no. 4055283 all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of Air filter for 160 / 200/250 KVA DG set of Make- Cummins/ Cottton greaves/ Kirloskar all as specified and directed by Engineer-in-charge.
Supply and fix in replacement water pump for 125/160 / 200 /250 KVA DG set of Make- Cummins/ Cottton greaves / Kirloskar, parts no. AR45347 all as specified and directed by Engineer-in-charge.
Supply and fix in replacement water pump for 62.5/82.5 KVA DG set of Make- Cummins/ Cottton greaves/ Kirloskar all as specified and directed by Engineer-in-charge.
S&F in replacement fan belt ( set ) for 62.5/82.5/125 KVA DG set of Make- Cummins/ Cottton greaves/ Kirloskar, part no. 178623 all as specified and directed by Engineer-in-charge.
S&F in replacement of fan belt ( set ) for 160/200/250 KVA DG set of Make- Cummins/ Cottton greaves/ Kirloskar, part no. 178611 all as specified and directed by Engineer-in-charge.
S&F in replacement belt water pump ( set ) for 62.5/82.5/125 KVA DG set of Make- Cummins/ Cottton greaves/ Kirloskar, part no.200328 all as specified and directed by Engineer-in-charge.
S&F in replacement of belt water pump ( set ) in 160/200 KVA DG set of Make- Cummins/ Cottton greaves/ Kirloskar all as specified and directed by Engineer-in-charge.
M & L for repair and reconditioning the starting motor of kirloskar / Cummins / Greaves make including taking out the defective starter from 82.5 KVA / 160 KVA / 200 KVA / capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assembly, bush, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge .
Supply and fix in replacement Carbon brush set with holder as per existing make and model suitable for 82.5 KVA / 160 KVA / 200 KVA capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement Solenoid switch assembly with bush as per existing make and model suitable for 82.5 KVA / 160 KVA / 200 KVA capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement commutator unit as per existing make and model suitable for 82.5 KVA / 160 KVA / 200 KVA capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement stator starting coil unit as per existing make and model suitable for 82.5 KVA / 160 KVA / 200 KVA capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement of stator running coil unit as per existing make and model suitable for 82.5 KVA / 160 KVA / 200 KVA / capacity DG set complete all as specified and directed by Engineer-in-charge .
M & L for repair and reconditioning of starting motor 12 V DC of kirloskar / Cummins / Greaves make including taking out the defective starter from 25 / 62.5 / 125 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bush, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge.
Supply and fix in replacement carbon brush set with holder as per existing make and model suitable for 25/62.5/125 capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement Solenoid switch assembly with bush as per existing make and model suitable for 25/62.5/125 capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement commutator unit as per existing make and model suitable for 25/62.5/125 capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement stator starting coil unit complete as per existing make and model suitable for 25/62.5/125 capacity DG set complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement stator running coil unit as per existing make and model suitable for 25/62.5/125 capacity DG set complete all as specified and directed by Engineer-in-charge .
M&L for repairs of copper/aluminium type radiator of 125/160/200 KVA capacity DG Sets, by disconnecting and taking out from DG set and locating the leaking places and soldering / brazing complete including cleaning by acid and refixing in position with replacement of old hose pipe with new complete all as specified and directed by Engineer-in-charge .
M&L for repairs of copper/aluminium type radiator of 25/62.5/82.5 KVA capacity DG Sets, by disconnecting and taking out from DG set and locating the leaking places and soldering / brazing complete including cleaning by acid and refixing in position with replacement of old hose pipe with new complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement Lub oil hoses set for DG set of capacity 160/200 complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement Lub oil hoses set complete for DG set of capacity 62.5/82.5/125 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement 3 pole ML- 4 Contactor, heavy duty with aux contacts 415Volt all as per existing make and model complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement 3 pole MNX 325 Contactor , heavy duty with aux contacts 415V all as per existing make and model complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement contactor 4 pole, heavy duty with aux contacts 415V, MCX 32 make L & T in existing AMF control panel of DG set 62.5 KVA, thorough checking, connecting with the system, testing for both Auto and manual mode operation all as specified as directed by Engineer-in-charge.
Supply and fix in replacement contactor 4 pole, heavy duty with aux contacts 415V, MCX 41 make L & T in existing AMF control panel of DG set 125 KVA, thorough checking, connecting with the system, testing for both Auto and manual mode operation all as specified as directed by Engineer-in-charge.
Supply and fix in replacement MCX 33 contactor 4 pole, heavy duty with aux contacts 415V, all as per existing make and model and fixing in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation complete all as specified as directed by Engineer-in-charge.
Supply and fix in replacement MNX-45 contactor 4 pole, heavy duty with aux contacts 415V, all as per existing make and model and fixing in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation complete all as specified as directed by Engineer-in-charge.
Supply and fix in replacement 220/415 Volt Coil suitable for ML-4 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement 215/415 Volt Coil suitable for MNX 325 / MCX 32 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement 220/415 Volt Coil suitable for MCX-41 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement 220/415 Volt Coil suitable for MCX-33 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge .
Supply and fix in replacement 220/415 Volt Coil suitable for MNX 45 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge .
Material and labour for taking down stator assembly of alternator for 25 / 62.5 / 82.5 / 125 KVA DG Sets by disconnecting electrically and mechanically complete cleaning with CTC and decarbonising the stator , rotor and excitor coils, heating the coils for achieving insulation upto the mark, checking thoroughly the complete system and connections and replacing the defective insulation paper by applying varnish, baking / heating and bringing back to installation and refixing, assembling the same, Connecting electrically , mechanically and testing on completion of work complete all as specified and directed by Engineer-in-charge.
Material and labour for taking down stator assembly of alternator 160/200 /250 KVA DG Sets by disconnecting electrically and mechanically complete cleaning with CTC and decarbonising the stator , rotor and excitor coils, heating the coils for achieving insulation upto the mark, checking thoroughly the complete system and connections and replacing the defective insulation paper by applying varnish baking / heating and bringing back to installation, refixing and assembling the same, Connecting electrically , mechanically and testing on completion of work complete all as specified and directed by Engineer-in-charge.
Supply and fix UVT trip coil 240/415 Volt operating system as per existing make and model suitable for MCCB model DH complete all as specified and directed by Engineer-in-charge.
M&L for replacement of unserviceable maintenance free lead acid battery with new maintenance free lead acid battery 12 Volt,180AH capacity complete with brass terminals including testing on load all as specified and directed by Engineer-in-charge.
M&L for replacement of unserviceable maintenance free lead acid battery with new maintenance free lead acid battery 12 volt 150 AH capacity complete with brass terminals including testing on load all as specified and directed by Engineer-in-charge.
M&L for replacement of unserviceable maintenance free lead acid battery with new maintenance free lead acid battery 12 volt 130 AH capacity complete with brass terminals including testing on load all as specified and directed by Engineer-in-charge.
Supply and fill distilled water for batteries 12 volt 180 / 150 AH / 130 AH all as specified and directed by Engr-in-Charge.
Supply & fix in repairs Automatic battery charging unit with indication of automatic charge, float with charge indication and cut off 220 V input AC and output 12/24 V DC -10 amps and testing with DG sets complete all as specified and directed by Engineer-in-charge.
Supply & fix alternator terminal connector in 200 KVA by taking out the burnt connector from alternator, checking cable lugs and connecting in the new terminal, tightening and testing complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement exhaust manifold set of three pieces with gaskets , stud mountings, nuts etc complete ( centre , rear and front) as existing make and model of 200 KVA / 160 KVA DG set all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement exhaust manifold set of three pieces with gaskets , stud mountings, nuts etc complete ( centre , rear and front) as per existing make and model of 82.5/125 KVA DG set all as specified and as directed by Engineer-in-charge.
Supply & Fix in repairs of PT fuel pump by dismantling, transporting to workshop, repairing and calibration, testing and commissioning for DG set of capacity 160 / 200 KVA / 250KVA including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed by Engineer-in-charge.
Supply & Fix in repairs PT fuel pump for DG set of capacity 82.5/ 125 KVA by dismantling, transporting to workshop, repairing and calibration, testing and commissioning including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed by Engineer-in-charge.
Supply and fix in replacement and commissioning 24 V DC heavy duty starter motor as per existing make and model suitable for 160 / 200/250 KVA Cummins / Kirloskar DG set all as directed by Engineer-in-Charge.
Supply and fix in replacement and commissioning 12 V DC heavy duty self starter motor as per existing make and model suitable for 125/82.5/ 62.5 KVA Cummins / Kirloskar DG set all as directed by Engineer-in-Charge.
M&L for Supply and fix in replacement DG Set door Hinges & accessaries, for 25/ 62.5/ 82.5 KVA DG Sets complete all as specified and directed by Engineer-in-charge.
M&L for Supply and fix in replacement DG Set door Hinges & accessaries, for 160/200/250KVA DG Sets complete all as specified and directed by Engineer-in-charge.
M&L for Supply and fix in replacement of solid state potentiometer of Make- Cummins part no. 3877372 in 200 KVA DG Set and testing all as specified and directed by Engineer-in-charge.
Supply and fix in replacement fan pulley assembly of 160/200 KVA DG Set as per existing make and model complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement Digital electronic control panel of DG set with mounting bracket , vibration isolating pads -3 nos for 160/200/250 KVA DG Sets as per existing make and Model Complete all as directed.
Supply and fix in replacement Digital electronic control panel of DG set with mounting bracket, vibration isolating pads -3 nos for 62.5/82.5/125 KVA DG Sets as per existing make and model complete all as directed at Site.
Supply & Fix Push button ( 2 nos ) as per existing make and model for ON / Off in 25 to 200 KVA AMF panel connecting with control circuit including connection and testing complete all as specified and directed by Engineer-in-charge.
Supply and fix coolant hose set Cummins part no. 67185 - 4 nos, 63495 - 2nos, AK 5045 SS - 1 no, AK 16030 SS - 1 no, AK 16018 MS - 1 no and set of clamps.
supply ad fixing Housing actuator as per existing make and model in 160/200 KVA DG set by taking out old from fuel pump, fixng the new housing actuator all as directed by Engineer-in-Charge.
Supply and fixing drive accessory as per existing make and model in 160/200 KVA DG set all as specified and directed by Engineer-in-charge.
Supply & fixing seal accessory as per existing make and model in 160/200 KVA DG set all as specified and directed by Engineer-in-charge.
S & fixing Electronic Governor controller as per existing make and model in 62.5/82.5/125/160/200 KVA DG set and testing all as specified and dicrected by Engineer-in-charge.
Supply, installation and commissioning of radiator for 200 KVA Cummins DG set as per existing make and model including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
Supply, installation and commissioning of radiator for 160 KVA/125 KVA Cummins DG set as per existing make and model including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
Supply, installation and commissioning of radiator for 62.5/82.5 KVA Cummins DG set as per existing make and model including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
Supply and fixing AMF Logic conttroller (Microprocessor based type) by taking out the defective unit from 125 / 62.5/82.5 KVA capacity DG set as per existing make and model complete checking the panel and its connection, circuit in the panel board, providing proper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge.
Supply and fixing AMF Logic conttroller (Microprocessor based type) by taking out the defective unit from 160/ 200/250 KVA capacity DG set as per existing make and model complete checking the panel and its connection, circuit in the panel board, providing proper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge.
Supply and fix start and stop relay 12 V/24 V DC suitable for AMF Panel capacity of 62.5 /82.5/125/160/200 KVA all as specified and directed by Engineer-in-charge.
S & F in replacement high bay light 50 W luminaries with high power (integral) with system lumen out put 220 volts, 50 Hz, with suitable capacity drivers complete all as specified and directed.
S & F in replacement heavy duty Exhaust fan 600 mm Sweep 240 volt , Opal White/brown including bracket nut bolts , and making hole for fitting fan on wall, making good to match with the existing including all accessories all as specified and directed by Engineer-in-charge.
S&F in replacement wall mounted fan (Air circulators) Turbo Force 600MM sweep compplete all as specified and directed by Engineer-in-charge.
Dismantling iron sections as in chequred plate and frame work to plates in any size and position all as specified and directed.
S&F plates (plain or chequred) plate channels squre cut or notched forming holes , without any attachement incl necessary welding as specified and directed.
S&F Rolled sections as in main and cross beam, frame work to ducts for laying chequred plates and similar work including necessary welding, grouting using PCC1:3:6 and amking good to surface as required all as specified and directed by Engineer-in-charge.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer on steel surfaces of any descrption , over 10cm width or girth, including preparing on new steel surfaces complete all as specified and directed.
Supply and fixing Digital panel board including Ammeter, Voltemeter , start and stop buttuns, oil temeprature , water pressure gauge , battery status indicator , suitable for 156 HP drainage pump all as specified and directed by Engineer-in-charge.
M&L for writing MES NO of DG set at INS Utkrosh power house , ATC & ASR Power house on DG set in white/black colour including paint and labour charge maximum 15 laters in one job all as specified and directed by Engineer -in - Charge.
Cleaning of fuel tank made of MS sheet of DG Set up to 200KVA capacity by draining out fuel in a separate container, taking out all silt/ dirt deposition inside the tank, cleaning it completely by manual labour and necessary T&P, refitting, refilling and connecting with fuel pipes with DG sets all as per site requirement and directed.
Supply and fixing battery lead with stranded copper conductor of size 70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for positive and stator terminal duly soldered all as directed.
Supply and fixing in replacement of battery lead with stranded copper conductor of size 70 sqmm single core PVC insulated flexible 0.6M long along with battery terminal for negative and stator terminal duly soldered all as directed.
M&L for disconnecting LT supply and taking out defective LT draw out EDO type ACB 440V 800Amp/630Amp/400 Amp of Make:- Legrand and servicing by cleaning the fixed and moving all parts, removing dust particles by using high speed blower applying grease/jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB complete and testing on full load all as directed at site.
Supply and fixing in replacement of isolating JAW contacts suitable for 800Amp/630Amp /400 Amp LT draw out EDO type ACB all as directed by Engr-in-Charge.
Supply and fixing in replacement of polyester resin cast CT 800/5A suitable for 800Amp/630Amp / 400 Amp LT draw out EDO type ACB as per existing make and model complete all as directed at site.
Supply and fixing in replacement of ARC Chutes for Air circuit brekers EDO type suitable for 800Amp/630Amp / 400Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of Pole Unit for Air circuit brekers EDO type suitable for 800Amp/630Amp / 400 Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of Draw out terminals for Air circuit brekers EDO type suitable for 800 Amp / 630 Amp / 400 Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of Lower terminals for Air circuit brekers EDO type suitable for 800Amp/630Amp / 400 Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of Upper terminals for Air circuit brekers EDO type suitable for 800Amp/630Amp/ 400Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of Charging motor for Air circuit brekers EDO type suitable for 800Amp/630 Amp / 400 Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of shunt trip and closing coil for Air circuit brekers EDO type suitable for 800Amp/630Amp / 400 Amp .
Supply and fixing in replacement of manual Charging handle for Air circuit brekers EDO type suitable for 800Amp/630Amp / 400 Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of under voltage trip device compact with UVT coil for Air circuit brekers EDO type suitable for 800Amp/ 630Amp / 400 Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of Safety shutter assembly for Air circuit brekers EDO type suitable for 800Amp/630Amp / 400 Amp as per existing make and model complete all as directed at site.
Supply and fixing in replacement of Earth fault relay with NCT for Air circuit brekers EDO type suitable for 800Amp/630Amp / 400 Amp as per existing make and model complete all as directed at site.
S&F in replacement of sheet metal enclosure with socket plug top , Triple pole and neutral enclosure with three pin earth plug and socket complete with one MCB TPN of capacity 32 Amps.
Attending breakdown / inspection of 25 KVA to 200 KVA DG Sets including AMF and Electrical Panel to check and locate / detect fault related to breakdown complete all as directed by Engineer-in-charge. Note:- (a) Spares will be measured and paid separately under relavant items. (b) The break down complaint should be attended within 2 hours with the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally. (c) Not attended of complaint within tow hours will lead to recovery from subsequent payment in the following manner :- (i) Not attending within 2 to 4 Hours - Rs. 2000.00 (ii) Not attending within 4 to 6 Hours- Rs. 4000.00 (iii) Not attending within 6 to 8 Hours- Rs. 8000.00 (iv) Not attending after 8 Hours - Rs. 10,000.00 (v) The maximum recovery will be Rs. 50,000.00 plus the expenditure incurred for rectification of the same by any other means.
KAPOOR AUTOMOBILES
Kathir Marketing Services
bansal construction
M/s Karbhagam Sales Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .