Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC DUE TO BEING L1 | |
| 2 | L2₹32.9 L+₹6.2 L (23.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹34.6 L+₹7.9 L (29.5%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹41.4 L+₹14.7 L (55.0%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
1 Oct 2021, 6:00 pmClosed
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Repair/Replacement of LV switchgear, ACBs, Earthing, LT overhead lines, LT cables, voltage stabilizers and allied work at CPH area under GE (Utilities) Udhampur
2021_MES_472532_1
GE/U-36/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹70,000
Yes
3 Nov 2021
3 Sept 2021
8 Oct 2021
3 Sept 2021
1 Oct 2021
17 Sept 2021
Amount
Decarbonising of LT Panel board / Feeder pillar boxes by CTC( Carbon Tetra Chloride), removing the carbon deposited inside the panel, cleaning the panel with cotton waste, applying one coat of becktol red solution, checking the faults inside the panel board and charging the LT Panel post completion of decarbonisation complete all as specified and directed by Engr-in-Charge. Note : (a) Proper shut down shall be taken prior the commencement of work . (b) Contractor shall provide 2 bottles of (250ml) - CTC . Cotton waste of not less than -1kg and Dr Bectol solution (250ml) - 1 no for performing the decarbonisation. (c) Fabrication of LT Panels for broken hinges shall be rectified. (d) LT Panel shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer. (e) Marking on LT panels shall be done as per sources of power supply (1100 volts) and outgoing area by 10cm glow sign/paint all as directions of Engr-in-Charge.
Replacement of earthing with Copper earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the earth plate not less than 1.5 M below ground level connected to Copper strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR-2009 part 1, including necessary excavation and earth work in any type of soil, common salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note: - (a) All the joints shall be made with welding to get proper conductivity. (b) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Painting to steel tubular swaged pole of Overhead lines (9 Mtr long) including MS angle,channel,clamp etc.complete with and including comprising the following works:- Note: - (a) Scraping out wornout old paint and making the surface smooth complete all as specified and directed by Engr-in-Charge. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) complete all as specified and directed by Engr-in-Charge. (c) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engr-in-Charge)synthetic enameled paint and marking pole no. with black and white paint complete all as specified and directed by Engr-in-Charge.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed by Engr-in-Charge.
Note: - (a) The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b) Prooning of all tree branches in one tree shall be measured as one Job. (c) Contractor will employ sufficient labour to complete the job with in time as directed. (d) Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply. However full assistance will be provided by MES staff. (f) The contractor will provide proper tools and safety devices to his staff for prooning of trees.
Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the end portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number with black paint at suitable height complete all as specified and directed by Engr-in-Charge. Note: - The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’.
Dismantling re-errecting, restringing, tensioning and repair to overhead line ACSR conductor any size upto 5 conductor in one span as required on poles LT / HT including fixing insulators and jointing with ACSR conductor complete all as specified and directed by Engr-in-Charge.
Taking down the burnt / unserviceable lugs from the LT Panel boards , Supply and fix aluminium thimble (Lugs) in replacement suitable for Cable of size 25 Sqmm complete all as specified and directed by Engr-in-Charge. Make: Dowells
Description all as per serial item No 7 here-in-before but for cable of size 35 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of size 50 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of size 70 Sqmm.
Description all as per serial item 7 here-in-before but for cable of size 95 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of size 120 Sqmm.
Description all as per serial item No7 here-in-before but for cable of size 150 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of size 185 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of size 240 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of size 300 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of size 400 Sqmm.
Description all as per serial item No 7 here-in-before but for cable of of size 630 Sqmm.
Taking out the existing unserviceable rusted bus bar panel board alongwith busbar with parts of any size/capacity including disconnection, dismantling PCC foundation etc and disposed off complete all as specified and directed by Engr-in-Charge.
Factory made sheet metal enclouser (junction box) made out of 14 SWG CRCA sheet powder coated weather proof outdoor type with 60 cm long legs 4 Nos made out of 40X40X6 mm equal angle size of enclosure not less than 75X60X30 cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 400 amps suitable of one incoming and 5 outgoing feeders, mounted on insulators including disconnection of cable from the burnt bus bar and reconnection of cable from the burnt bus bar and reconnection in the new chamber with nuts and bolts including lugs of suitable sizes, necessary earth work and PCC foundation for grouting of four legs all as per existing complete all as specified and directed by Engr-in-Charge.
On load change over switch, 800 Amps, 4 pole, conforming to IEC 947-3 including taking down old U/S change over switch complete all as specified & directed by Engr-in-Charge. Make:- Havells / L&T/ Schneider
All as per serial item No. 10 here-in-before but of capacity 630 Amps, 4 pole
All as per serial item No. 10 here-in-before but of capacity 400 Amps, 4 pole
All as per serial item No. 10 here-in-before but of capacity 250 Amps, 4 pole
Taking down the unserviceable LT Cable from the system . Supplying, laying, jointing and testing LT underground cable of size 400 sqmm 3.5 Core, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Note: - GI Tubing and earth work shall be measured and paid seperately under respective item of Sch 'A'.
Description all as per serial item No 14 here-in-before but size of 300 Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 240 Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 185 Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 120 Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 95 Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 70Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 50 Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 35 Sqmm 3.5 Core.
Description all as per serial item No 14 here-in-before but size of 16 Sqmm 4.0 Core.
Description all as per serial item No 14 here-in-before but size of 16 Sqmm 2.0 Core.
Description all as per serial item No 14 here-in-before but size of 10 Sqmm 2.0 Core.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m deep for foundations of poles/stays etc not exceeding 10sqm area on plan and getting out in solft/loose soil complete all as specified and as directed by Engr in Charge.
Returning, filling in, excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
DWC Pipe ( Double wall corruguated) conforming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for LT Cable of size 400sqmm (110X 95 mm as diameter) including taking out/down old unserviceable pipe of any capacity/size all as specified & directed by Engr-in-Charge. Make : Rex Poly extrusion / Tirupati
DWC Pipe ( Double wall corruguated) conforming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for LT Cable of size 300/240 sqmm (90X 76 mm as diameter) including taking out/down old unserviceable pipe of any capacity/size all as specified & directed by Engr-in-Charge. Make : Rex Poly extrusion / Tirupati
DWC Pipe ( Double wall corruguated) conforming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for LT Cable of size 185/120sqmm (77X63 mm as diameter) including taking out/down old unserviceable pipe of any capacity/size all as specified & directed by Engr-in-Charge. Make : Rex Poly extrusion / Tirupati
DWC Pipe ( Double wall corruguated) conforming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for LT Cable of size 95/70sqmm (63X50 mm as diameter) including taking out/down old unserviceable pipe of any capacity/size all as specified & directed by Engr-in-Charge. Make : Rex Poly extrusion / Tirupati
DWC Pipe ( Double wall corruguated) conforming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for LT Cable of size 50/35sqmm (50X38 mm as diameter) all as specified & directed by Engr-in-Charge. Make : Rex Poly extrusion / Tirupati
DWC Pipe ( Double wall corruguated) conforming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for LT Cable of size 16 sqmm (40X 32 mm as diameter) including taking out/down old unserviceable pipe of any capacity/size all as specified & directed by Engr-in-Charge. Make: Rex Poly extrusion / Tirupati
Straight through joint kit, heat shrinkable type suitable for 50 to 95 Sqmm LT underground cable complete including taking out old unserviceable straight through joint kit all as specified and directed by Engr-in-Charge.
Straight through joint kit, heat shrinkable type suitable for 120 to 185 Sqmm LT underground cable complete including taking out old unserviceable straight through joint kitall as specified and directed by Engr-in-Charge.
Straight through joint kit, heat shrinkable type suitable for 240 Sqmm to 300 sqmm LT underground cable complete including taking out old unserviceable straight through joint kitall as specified and directed by Engr-in-Charge.
MCCB 4 pole (in replacement), Ics=100%Icu- 35/36 KA, 415 Volts, 630 Amps , with adjustable thermal and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
MCCB 4 pole (in replacement), Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
MCCB 4 pole (in replacement), Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
MCCB 4 pole (in replacement), Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
MCCB 4 pole (in replacement), Ics=100%Icu- 35/36 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
MCCB 4 pole (in replacement), Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
LT change over switch Onload type 400 Amps, 4 pole, 50 HZ, conforming to IEC 947-3 including taking down old unserviceable change over switch 400 Amps complete all as specified & directed by Engr-in-Charge. Make:- Legrand/ L&T/Havells
Opening, maintenance and general servicing of Servo voltage stablizers of different makes (Rating from 30 KVA to 400 KVA) including removal of sludge from disserstate coils, Buck Boost Transfromers, tightening of all nut bolts, cleaning of stablizer coils, checking and servicing of servo mechanism, gear synchronising system, automatice voltage regulator circuits and other allied electrical components complete all as specified and directed by Engr-in-Charge. Note : a) Rate quoted by contractor is inclusive of shifting of stabilizer from CPH area to workshop (Tro/Fro) b) OEM Service engineer shall be engaged for rectification of defects (c) Minor items like carbon brushes, Push buttons & varic resistors are inclusive of rate quoted.
Replacement of Servo Motor with RC Net work having torque of 3 Kg/cm as per existing make complete all as specified and directed by Engr-in-Charge.
Replacement of Servo Motor with RC Net work having torque of 10 Kg/cm as per existing make complete all as specified and directed by Engr-in-Charge.
Replacement of Electronic Control Card (H/J) for Automatic Voltage regulation as per existing make complete all as specified and directed by Engr-in-Charge.
Replacement of wiring of Electronic Control panel complete all as specified and directed by Engr-in-Charge.
Replacement of Control Transformer complete all as specified and directed by Engr-in-Charge.
Top up of transformer oil (ISI Marked) suitable for existing voltage stablizer as per IS 335 part-1 complete all as specified and directed by Engr-in-Charge.
Rewinding of variac coil conforming to the original specifications of the servo stablizer of any make/capacity with super enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete all as specified and directed by Engr-in-Charge.
ACSR conductor of required size for Over head lines on poles including streching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor including taking down old unserviceable conductor from OH structure complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-10, type D-2 (using 40mm graded crushed stone aggregates) as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-10, type C-1 (using 20mm graded crushed stone aggregates) for coping of poles incl all necessary form work complete all as specified and directed by Engr-in-Charge.
Taking down the U/S ACBs from existing LT panel boards, S&F LT ACB, 4 pole, 415 V, 1000 Amps, 4 pole,50 Hz with magnetic release, manual draw out type, Ico-50 KA with all as specified & directed. Make:- Schneider/ Legrand/ L&T/Havells
Taking out the existing unserviceable rusted LT panel board alongwith bus bar, MCCBs etc of any size/capacity including disconnection, dismantling PCC foundation etc and disposed off complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments: -
Outgoing: - (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 63 Amps with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Note: - (i) Rates quoted by the contractor shall be deemed to include for:- (a) Connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (b) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs all as directed by Engineer-in-Charge. Note: Drawing of LT panel shall be submitted to department for approval before procurement.
Taking down the U/S panel mounted in ACB of 800 amp capacity, S&F LT ACB with sheet metal enclosed pedestal type to house ACB 800 Amps 4pole, manual draw out magnetic release breaker of capacity 50 KA all as specified & directed by Engr-in-Charge. Make of ACB:- Schneider/ Legrand/ L&T/Havells
1100 Volts grade heavy duty cable (in replacement) PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service conncetions one twin core 10 Sqmm cable flat or round complete all as specified and directed by Engr-in-Charge.
proach associates
MOHAN LAL AND SONS
FANGALIA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .