| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAccepted-AOC NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | ₹5.5 Cr Quoted ₹5.6 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹5.7 Cr+₹12.6 L (2.24%)Rejected-AOC | ₹5.7 Cr+₹12.6 L (2.24%) | L2 | Rejected-AOC Not being lowest bidder |
| 3 | L3₹5.8 Cr+₹23.0 L (4.09%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | ₹5.8 Cr+₹23.0 L (4.09%) | L3 | Rejected-AOC Not being lowest bidder |
| 4 | L4₹6.0 Cr+₹34.0 L (6.05%)Rejected-AOC NO 18 8 254 26 RAKSHAPURAM SAIDABAD POST HYDERABAD 500 005 | HYDERABAD | HYDERABAD | TELANGANA | 500005 | ₹6.0 Cr+₹34.0 L (6.05%) | L4 | Rejected-AOC Not being lowest bidder |
| 5 | L5₹6.0 Cr+₹37.6 L (6.69%)Rejected-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹6.0 Cr+₹37.6 L (6.69%) | L5 | Rejected-AOC Not being lowest bidder |
| Sl No | Description | Qty | Unit | SAI RUPA CONSTRUCTIONS L3 | Sukhdevraj Sharma Engineers & Contractors Pvt Ltd L2 | Shree Construction Co. L5 | R. Wadhumal and Sons L8 | ASHOK CONSTRUCTION L1 | G.CHANDRIAH AND SONS L7 | Dwarka Pershad Radhey Ramanlal L9 | S.R.M.K Enterprises L6 | saradhi construction combines L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete in roof including complete removal of existing roof treatement (other than ground floor) and removing debris to a distance of n.exc 100M away from the bldg complete all as specified and directed. | 65.8 | Cubic Meter | 900 ₹59,220 | 225 ₹14,805 Lowest | 250 ₹16,450 | 400 ₹26,320 | 400 ₹26,320 | 600 ₹39,480 | 400 ₹26,320 | 500 ₹32,900 | 300 ₹19,740 |
| 2.00 | M&L for 25 mm average thick PCC (1:2:4) Type B0 by using 12.50 mm graded stone aggregate as in roof where required over slabs and finishing the exposed surfaces fair even without using extra cement complete all as specified and directed. | 1,880 | Square Meter | 126 ₹2,36,880 Lowest | 225 ₹4,23,000 | 150 ₹2,82,000 | 175 ₹3,29,000 | 170 ₹3,19,600 | 150 ₹2,82,000 | 200 ₹3,76,000 | 250 ₹4,70,000 | 180 ₹3,38,400 |
| 3.00 | M&L for 10mm thick rendering in CM 1:4 using water proofing compound at the rate of 3% weight of cement over concrete surfaces complete all as specified and directed. ( Note : WPC measured and paid separately) | 1,880 | Square Meter | 144 ₹2,70,720 | 180 ₹3,38,400 | 200 ₹3,76,000 | 21 ₹39,480 Lowest | 140 ₹2,63,200 | 150 ₹2,82,000 | 200 ₹3,76,000 | 200 ₹3,76,000 | 150 ₹2,82,000 |
| 4.00 | M&L for providing APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyester/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litre/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminium paint on top @ 0.20 litre/sqm complete all as specified and directed. | 1,880 | Square Meter | 405 ₹7,61,400 | 423 ₹7,95,240 | 410 ₹7,70,800 | 365 ₹6,86,200 Lowest | 520 ₹9,77,600 | 450 ₹8,46,000 | 450 ₹8,46,000 | 450 ₹8,46,000 | 400 ₹7,52,000 |
| 5.00 | Supply only water proofing compound | 523.39 | Kilo Gram | 45 ₹23,552.55 | 36 ₹18,842.04 Lowest | 80 ₹41,871.2 | 110 ₹57,572.9 | 50 ₹26,169.5 | 45 ₹23,552.55 | 40 ₹20,935.6 | 150 ₹78,508.5 | 50 ₹26,169.5 |
| 6.00 | Dismanting single layer mangalore pattern or similar tiles in roofing complete all as specified and directed. | 1,950 | Square Meter | 18 ₹35,100 Lowest | 18 ₹35,100 Lowest | 30 ₹58,500 | 50 ₹97,500 | 25 ₹48,750 | 20 ₹39,000 | 50 ₹97,500 | 50 ₹97,500 | 20 ₹39,000 |
| 7.00 | S & F prepainted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPA asin roof covering/cladding to wall fixed with self tapping screws as specified. | 3,989.4 | Square Meter | 810 ₹32,31,414 | 760 ₹30,31,944 | 720 ₹28,72,368 | 770 ₹30,71,838 | 740 ₹29,52,156 | 800 ₹31,91,520 | 900 ₹35,90,460 | 750 ₹29,92,050 | 700 ₹27,92,580 Lowest |
| 8.00 | S&F pre painted galvalume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour having tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws as specified | 356.4 | Square Meter | 900 ₹3,20,760 | 760 ₹2,70,864 | 730 ₹2,60,172 | 840 ₹2,99,376 | 740 ₹2,63,736 | 800 ₹2,85,120 | 850 ₹3,02,940 | 700 ₹2,49,480 Lowest | 725 ₹2,58,390 |
| 9.00 | Removal of Battens for spacing N exc 15 cm tiles, shingles, etc of any size including tilting fillets complete all as specified and directed. | 1,950 | Square Meter | 18 ₹35,100 | 18 ₹35,100 | 30 ₹58,500 | 28 ₹54,600 | 15 ₹29,250 Lowest | 20 ₹39,000 | 50 ₹97,500 | 40 ₹78,000 | 30 ₹58,500 |
| 10.00 | Dismantling framed wooden purlin/Rafter work of any description sectional area under 40 Sqcm not other wise provided for, complete all as specified and directed. | 4,215 | Running Meter | 9 ₹37,935 | 18 ₹75,870 | 30 ₹1,26,450 | 28 ₹1,18,020 | 8 ₹33,720 Lowest | 10 ₹42,150 | 100 ₹4,21,500 | 20 ₹84,300 | 10 ₹42,150 |
Tender Value
₹7.2 Cr
EMD Value
₹6.8 L
Closing Date
9 Feb 2026, 6:00 pmClosed
Chief Engineer Chennai Zone, Chennai
Chief Engineer Chennai Zone, Chennai
ADDN/ALTN AND SPL REPAIRS TO VARIOUS MARRIED ACCN IN AOC CENTRE UNDER GE (South) SECUNDERABAD.
2026_MES_747674_1
89118/E8
Open Tender
Civil Works
Item Rate
365 days
Secunderabad
As per tender documents
8 documents required · 8 mandatory
₹3,000
Secunderabad
₹6.8 L
Yes
17 Apr 2026
9 Jan 2026
16 Feb 2026
10 Jan 2026
9 Feb 2026
2 Feb 2026
Demolition of cement concrete in roof including complete removal of existing roof treatement (other than ground floor) and removing debris to a distance of n.exc 100M away from the bldg complete all as specified and directed.
M&L for 25 mm average thick PCC (1:2:4) Type B0 by using 12.50 mm graded stone aggregate as in roof where required over slabs and finishing the exposed surfaces fair even without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:4 using water proofing compound at the rate of 3% weight of cement over concrete surfaces complete all as specified and directed. ( Note : WPC measured and paid separately)
M&L for providing APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyester/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litre/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminium paint on top @ 0.20 litre/sqm complete all as specified and directed.
Supply only water proofing compound
Dismanting single layer mangalore pattern or similar tiles in roofing complete all as specified and directed.
S & F prepainted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPA asin roof covering/cladding to wall fixed with self tapping screws as specified.
S&F pre painted galvalume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour having tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws as specified
Removal of Battens for spacing N exc 15 cm tiles, shingles, etc of any size including tilting fillets complete all as specified and directed.
Dismantling framed wooden purlin/Rafter work of any description sectional area under 40 Sqcm not other wise provided for, complete all as specified and directed.
S & F roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A.
M&L for providing cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets. all as specified and as directed.
M&L for providing false ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mm and aluminium wall angle size 25x25x1.8 mm fixed to wall hanging from soffits\trusses\bracking using adjustable supporting hanger compressing of GI wire 4mm thick with locking clip complete all as sepcified and directed by Engr-In-Charge.
M&L for Providing and fixing Non-asbestos designer E-Board 4mm thick in ceiling fixed to snap grid as per manufacturers instructions complete all as sepcified and directed by Engr-In-Charge.
Dismantling structural steel work including doors, gates, railling but excluding framed truss etc.
S &F for framed work such as grills, grating etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars(for windows); barred iron doors; ladders; framed balusters; walk ways; railings; framework of watertanks and similar work conforming to Fe 290. Gde E-165
M&L for Preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat primer. all as specified & directed.
M&L for Preparatioin of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified & directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc all as specified and as directed. .
M&L for brick work with flyash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 all as specified and as directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia for securing with clips quality conforming to deformed or TMT bars complete all as specified and directed.
All as per Item No 23 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders TMT bars complete all as specified and directed.
M&L for Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc.rough finished surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) in type B1 1:2:4 (20 mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Taking down plaster on brick / concrete / stone masonary sunfaces including racking out joints, hacking for key, scrabing down with water etc. complete all as specified and directed.
M & L for 15 mm thick rendering in Cement Mortar 1:4 on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement. complete all as specified and directed. Note : Roof projection/sun shade portion upto ht 7.50m incl necessary scaffolding complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed.
M&L for 10 mm thick rendering in Cement Mortar 1:3 on fair faces of Brick works or Concrete surfaces in ceilings and finishing even and fair without using extra cement. complete all as specified and directed. Note : Roof projection/sun shade portion upto ht 7.50m incl necessary scaffolding
M&L for preparation of newly plastered surfaces of wall for two coats of cement base paint over a coat of primer all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying one coat of 1mm thick putty over one coat of primer to obtain smooth regular/even finish using sand paper and applying two coats of OBD of any tint complete all as specified and as directed.
M&L for Preparation of newly plastered surfaces of wall applying three coats of white wash on ceiling over primer complete all as specified and as directed.
M&L complete removal of existing treatment and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. Note : (i) Will be done by roller only, after complete removal of old loose flakes. (ii) Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.
M&L for complete removal of existing treatment and applying two coats of white wash on ceiling surfaces.complete all as specified and directed. Note : Will be done by roller only, after complete removal of old loose flakes. (ii) Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.
M&L for complete removal of existing treatment on walls and applying one coat of 1mm thick putty over one coat of primer to obtain smooth regular/even finish using sand paper and applying two coats of OBD of any tint complete all as specified and as directed. Note : Will be done by roller only, after complete removal of old loose flakes. (ii) Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.
Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed.
Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided including floor finishes complete all as specified and directed.
Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) finished fair & even as in Sub base flooring complete all as specified & directed.
M&L for glazed ceramic tiles, coloured, of size 350 x 250 x 7mm or 450 x 300x 7mm , as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick plaster on wall in cement mortar 1:4 complete all as specified & directed.
M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/ rectangular) area of each tile exc 0.06 and not exceeding 0.11 Sqm in floors surface set and jointed in neat cement slurry and pointed with white or colour cement to match over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified & directed.
M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors surface set and jointed in neat cement slurry and pointed with white or colour cement to match over and including 15mm screed bed in cement mortar 1:6 complete all as specified & directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite and incl Rounding to edges of stone slabs one edge complete all as specified and as directed.
S&F 18-20 mm thick kota stone as in floors over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish and rounding chamfered edges where directed complete all as specified and diirected.
All as per item No 45 above but 16 to 18m thck kota stone slab as in small width in vertical surfaces like landings, risers, treads, skirtings, dado, etc over and including 10mm thick packing coat in cement mortar 1:4 complete all as specified and directed.
M&L for Machine cut cudappah stone slab 20-25mm thick small wiidth in window cills over 15mm screed base in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rounding to edges of stone slabs one edge, cills, cooking platform, and other similar situations rubbing and polishing and existing windows for any required chipping and clear neat existing structure and all as complete specified and directed.
Taking down chowkat with frame (without taking off shutter from the frame) n exc 1.50 Sqm each complete all as specified & directed.
All as per item no:48 above, but area exc 1.5 Sqm n.exc 4 Sqm each complete all as specified.
Taking down shutter of any description exc 1 Sqm & n exc 2 Sqm each complete all as specified & directed.
M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube supplying & fixing in opening as per specification & drawing.
M&L for 2nd class hard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F factory made solid PVC moulded shutter with 28 to 30mm thick(stiles)with 2,4 or 6 raised panel design with 2mm thick moulded PVC prelam sheet on the front face and 2mm thick plain colour PVC sheet on back face with particle board core complete all as specified and directed.
S&F 35mm thick factory made plain framed paneled shutter of 2nd class HW (any Number of panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm th venered particle board with veneering on both face kiln seasoned & chemically treated complete all as specified & directed.
S&F 35mm thick 2nd class hard wood glazed skeleton shutters open rebated and prepared to receive glass and divided into square with plain, rounded, chamfered, mitred and rebated sash bars.complete all as specified & directed.
S&F 100mm long Stainless steel butt hinges with galvanised aluminium pin.complete all as specified & directed.
S&F 100mm butt hinges medium weight cold rolled mild steel complete all as specified & directed.
S&F Aluminium handle 150mm fabricated type complete all as specified & directed.
S&F Aluminium anodised barrel tower bolts 150mm of extrded section complete all as specified & directed.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 300 mm long helical door springs including roller plate complete all as specified & directed.
S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire with avg 1.18mm width of aperture and fixed with tinned tacks. complete all as specified & directed.
All as per item no:62 above but fixed in repairs complete all as specified & directed..
Hacking out old broken glass any description & size from wooden/steel window and removal of rubbish from work site as directed.
S&F 3mm thick sheet glass ordinary quality and fixed with oil putty in square not exc 0.5 sqm in each pane complete all as specified & directed.
S&F 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor complete all as specified and directed.
S&F Windows/Ventilators fabricated from roll framed sections made of galvanized steel colour coated/ powder coated (Base steel as per IS 513 “D” quality galvanized as per IS 277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm. Paint Specifications: Coated sections should be with Primer coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester paint of 12-16 microns thick or Powder Coated with pure Polyester up to 50-60 microns thick. Dimensions of Sections: Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm. Fixing Details: Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter. Accessories: Each Glazed Shutter and Mesh shutter should be provided with SS Pivot Hinges – 1 set, Seccolor Handle & Seccolor Stay. Window Frame should be fixed to brick/ concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frame
Glass: Glass shutter & Fixed Glass portions should be provided with a glass of 4MM Plain Float Glass. Mesh: Mesh Shutter should be provided with a Stainless Steel Fly mesh of 304 grades. Grill: Windows should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm center-to-center, 5mm x 10mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. Note: All existing wooden/steel windows & ventilators inclunded tacking down.
M & L for preparation of new wooden surface and applying 2 coats of synthetic enamel paint over one coat of pink primer over 10cm width or girth complete all as specified.
M&L for complete removal of existing treatment of old wooden surface and applying 2 coats of synthetic enamel paint over one coat of pink primer over 10cm width or girth complete all as specified.
Taking down AC/PVC pipes of any description any pattern incl all fittings heads, shoes bends etc all as specified.
S&F PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls or in floors all as specified.
S&F PVC (SWR) pipes of 75mm dia single socketed in any length with rubber ring joints fixed to walls or laid in trenches or in floors all as specified.
S&F PVC (SWR) bends 110mm dia any radius complete all as specified and directed.
S&F PVC (SWR) bends 75mm dia any radius complete all as specified and directed.
S&F PVC (SWR) bends 110mm dia any radius with access door complete all as specified and directed.
S&F PVC (SWR) bends 75mm dia any radius with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm dia complete all as specified and directed.
S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement in repair complete all as specified and directed.
Demolition of cement concrete of any desscription and any position exc 15 cm thickness below or above ground level complete all as specified and directed.
Taking down the plaster incl existing treatment in sunken portion, washing down with water and applying 15mm thick plaster in CM 1:4 with 3% WPC all around incl floors and applying Shaliu Urethane BTD two coats @ 1.5 Kg/Sqm each Coat (Apply 2nd Coat after 6 Hrs) over a coat of Shali Pime WP @ 200gm/sqm and Provide 40mm GI Spout Pipe complete all as specified and as directed.(Note : Supply of water proofing compound will be measured and paid separately).
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in filling of sunken portion etc complete all as specified and directed.
Taking up or down 15 mm steel tubing and connections, including all fitting heads in wall/floor complete all as specified & directed
Taking up or down 20 mm steel tubing and connections, including all fitting heads in wall/floor complete all as specified & directed
S&F 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed
S&F 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed
S&F 15mm bore chromium plated Bib taps, with crutch or butterfly handle, screweddown, screwed for iron/CPVC pipe or for brass ferrule and fixed in repairs complete all as specified & directed
S&F 15mm bore chromium plated long body Bib taps, with crutch or butterfly handle, screwed down, screwed for iron/CPVC pipe or for brass ferrule and fixedin repairs complete all as specified & directed
S&F Brass two way CP mixture for mixing hot & cold water screwed down for iron pipe and fixed screwed for iron/CPVC pipe or for brass ferrule and fixedin repairs complete all as specified & directed
S&F in repairs stop cock 15mm dia copper alloy with crutch or butterfly handle, screweddown, screwed for iron pipe or for brass ferrule and fixedin repairs complete all as specified & directed
S & F in repair Vitreous china Squatting pan Orissa pattern of size 580mx440mm white with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding complete.all as specified & directed
S&F in repairs wash down water closet (pedestal pattern) complete white with plastic water closet seat black closed pattern with flat bottom anc cover and mild steel chromium plated or aluminised hinging deviceincl PVC health faucet with 01 Mtr tube and hookand complete all as specified & directed.
S & F in repair PVC valveless syphonic action type low level flushing cistern 10 Ltr capacity with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low or high density PVC 32mm dia pipe for low level flushing cistern complete and directed
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450 mm all as specified and directed
S&F in repair CP Soap dish fixed with chromium plated brass screw complete all as specified and directed.
S&Fin repair WHB vitreous china (flat back or angle back type ) any size ,including cutting for pinning in ends size 550x400 mm including brackets, out let pipe, coupling, connection pipe 450mm and fancy type CP mixture complete all as specified and directed.
S&Fin repair WHB vitreous china (flat back or angle back type ) any size ,including cutting for pinning in ends size 450x300 mm including brackets ,out let pipe ,coupling ,connection pipe 450mm and CP mixture complete all as specified and directed.
S&F 25mm Stainless steel curtain rods incl required nos of brackets complete all as sepcified and directed by Engr-In-Charge.
S & F in repair Tubular towel rail, 20mm dia, D type, 60 cm long brass cromium plated incl all fitting & fixtures complete all as specified and directed.
S&F in repair chromium plated shower rose 125mm size with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
S&F stainless steel Kitchen plate rack of overall minimum size 600mm x 600mm and 230mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed. Note : Weight of rack shall not be less than 3.80 Kg.
S & F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified and directed.
S&F rotational moulded polyethylene water storage tanks 500 litre capacity incl (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I including dismantling and taking down existing water tank complete all as specified & directed.
S&F 20 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe as in repairs complete all as specified & directed.
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weigth 455gms) 20mm bore complete all as specified and directed.
S&F for 18 mm thick , prelaminated medium density fibre (MDF) , interior grade, prelaminated one side with decorative choice lamination and other side balancing white with lamination fixed with screw to timber/ steel frame work as in CB shutter, shelves etc with PVC liping on all exposed edges on same texture and shade. Stainless steel cleat of suitable size will be use to fix the shelves of CB and cabinets complete all as specified and directed.
Supply and fix 200 mm long stainless steel decorative handle fixed with screws complete all as specified .
Supply and fix 200 mm long stainless steel hinge for cabinets auto close , concealed type complete all as specified .
Supply and fix Stainless steel Telescopic type ball bearing drawer channel of any size complete all as specified .
Supply and fix Stainless steel kitchen basket of size 17" x 20" x 4" size complete all as specified .
Supply and fix Stainless steel kitchen basket of size 17" x 20" x 6" size complete all as specified .
Supply and fix Stainless steel kitchen basket of size 17" x 20" x 8" size complete all as specified .
Supply and fix Stainless steel dust bin holder 10 " dia complete all as specified and as direcetd .
Supply and fix stainless steel bottle pullout of size 106 mm X 476 mm X 130 mm complete all as specified .
Supply and fix in repair CP Quarter Turn Sink Cock with regular swinging spout ( wall mounted model ) with wall flange complete all as specified .Make : Cat No-FLR-5347N of Jaquar or equivalent .
Demolition of reinforced cement concrete in Roof slab, floors (other than ground floors), beams, staircases, landing, chajjas /sunken portion of WC/Bath of any thickness complete all as specified and as directed.
Removal of damaged concrete along with loose damaged and cracked concrete/cover concrete at all specified locations up to beyond the corroded steel reinforcement to a depth of 10 mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chipper including high pressure water jetting to chipped concretand reinforcement and removal and disposal of debris within owners premises including all plant and machineries. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed. Depth of chipping may very from 50 mm to150 mm complete with labor, machinery, tools etc. all a directed by Engg.in charge. The edges of repair locations shall be saw cut to a depth of at least 10 mm to avoid feather edgeing and provide a square edge. Removal of dust, loose particles, marine growth etc. from concrete surface manually by wire brush, mechanically or any other means to obtain a sound surface over areas other than above.
Cleaning as directed & specified all rust/ scales/corrosion from reinforcement bars using rust remover agent like Reebaklens RR of Fosroc or equivalent having Specific Gravity 1.16 - 1.22. The material to be applied to the rusted metal using brush and make leaving to dry for 30 mins & washing surface with fresh water as required to exposed reinforcement bars complete as specified.
M&L for providing & applying inhibition coats/system to exposed reinforcement bars after drying & also new bars after cleaning & removing scales and rust completely as specified. Two component inhibitor Nitozinc Primer or equivalent having specific gravity of 1.75, Adhesive bond strength > 1.5 N/mm2, Solid content- 60 %, 40 microns DFT as approved by engineer shall be used as per manufacturers specification in two coats including all labors, tools and tackles, necessary surface preparation and necessary protection after and during work complete all as specified and directed.
M&L for providing and applying bond coat on the prepared surface to receive polymer modified mortar/polymer modified micro concrete, with two component epoxy based bonding coat Nitobond EP Std of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs. and 300 C. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. The bond coat act as a bonding coat between old and new concrete. Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc. complete as per specified and directed.
M&L for providing and applying polymer modified micro-concrete like Renderoc RG of Fosroc make or equivalent having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days, Young’s modulus-25 kN/mm2, Expansion characteristics (ASTM C827 - 1987)Unrestrained expansion 1 to 4 %,Pressure to restrain Plastic Expansion-Approx. 0.004 N/mm2,Thermal Conductivity – 1.5 W/m C. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc. complete as specified and as directed.
M&L for providing and laying of polymer modified single component, alkaline resistant fiber reinforced, thixotropic, cementitious patch repair mortar Renderoc SP 40 of Fosroc make or equivalent that achieves compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength (BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 micro strain. Finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc., where the thickness of application is average 30 mm in patches as per specification after applying bonding coat (bonding coat shall be payable separately). Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc. complete as specified and as directed.
M & L of Acrylic emulsion based curing compound-Concure AB; Solids content : 33 ± 1% as per (ASTM D1644; Drying time : < 4hrs @ 23°C(ASTM C135, M 8.3) complete all as specified and directed.
Supply of Polymer admixture for waterproofing and anti carbonation coating Emulsified Acrylic Polymer complete all as specified and directed.
M&L for applying putty of 1 mm thickness over plastered surface of ceiling to prepare the surface even and smooth finish complete all as specified and directed.
Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in Cement or Cement Lime mortar; not previously plastered; and scrubbing down with water etc. to receive plaster complete all as specified and directed.
M&L for Additional Reinforcement Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement which was reduced to 20 % or more of its originaldiameter as provided in original structure and additional steels as directed by EIC as required welding or tying with 16 guage annealed binding wire complete as per drawing and specifications for heights as directed by EIC.
M&L for providing and executing injection/pressure grouting in cracks in the parent concrete by fixing PVC nipples at 150 mm to 200 mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout Conbextra EP 10(M) of Fosroc or equivalent having mix density 1060 kg/m3,Compressive Strength(ASTM D695)-60 N/mm2,Tensile Strength(ASTM C 304-97)-20 N/mm2,Flexural strength(BS 6319 Part 4)-45 N/mm2.Pressure grouting shall be done at required pressure etc.shall complete as directed by EIC. Payment shall be made on actual grout consumed.
Demolition of Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete.
M&L for 75 mm thick plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with bitumastic filling in proportion of bitumen and sand (1:2) complete as specified and directed.
Supply and fix in repair bathroom mirror cabinet PVC of size 400 X 500 mm fancy type complete all as specified and as directed . Make : Prayag or equivalent .
M&L for complete removal of existing treatment including preparing surfaces of wall & Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified and directed.
M&L for new plastered surfaces & Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed.
M&L for complete removal of existing treatment including preparing surfaces of ceiling & Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
Supply and fix in repair 15 mm bore pillar tap of cast copper alloy with capstan head , chromium plated , fancy type , screwed down high pressure with or without lettered 'Hot' or 'Cold with long screwed shanks and fly nuts , screwed for iron pipe complete all as specified and as directed. Make : Cat No:CON-021KN of Jaquar or equivalent .
Supply and fix in repair 150 X150 mm overhead shower complete all as specified. Make :Cat No:OHS-CHR-1605 of Jaquar or equivalent .
Supply and fix in repair shower arm 400 X 25 X25 mm square shape for wall mounted shower complete all as specified .Make : Cat No:SHA -455L400 of Jaquar or equivalent .
S&F of rotational moulded poly thylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 Ltrs complete all as specified specified in SSR Pt-I including dismantling and taking down existing water tank complete all as specified & directed.
Supply and fix in repair CP health faucet with 01 Mtr tube and hook complete all as specified .
S&F in repairs toilet paper holder, vitreous china, box type coloured, fixed with chromium plated brass screw complete all as specified.
S&L in repairs CI floor trap with grating incl jointing to waste pipe with dia of outlet 75mm complete all as specified and directed.
S&F HDPE pipes or pressure rating 6kgf/sqcm of 40 mm dia fixed/concealed on walls or floors complete all as specified and directed.
M&L for stainless steel railing of grade 304, including bending ends, cutting, welding, smoothing cutting to holes, embedded in cement concrete etc all as specified and directed by Engr-in-Charge.
S&F in repair stainless steel sink without draining board made out of 1.00 mm thick sheet for kitchen with plug and washers, waste pipe with cantilever brackets over all size 495mm x420mm bowl size 410mm X 330mm X160mm complete all as specified and directed.
S&F in repairs Stainless steel 6 shelf wall mount utensils plate rack of size 36" X 36" X 10 "(Lower 3 plate) weight not less than 7.6 Kg complete all as specified and directed. Make : Prayag or equivalent
S&F in repair vitreous china wash down water closet (pedestal pattern) with plastic seat and cover including PVC low level flushing cistern 10 ltrs capacity complete as directed by Engr-in-Charge. Note :- Cat No - CNS-WHT-551SNPP184LZ of JAGUAR or equivalant make of CERA or HINDWARE.
Supply & fixing in repair vitreous china wash basin with padestal , white flat size 550x400mm incl bracket cutting for and pining in ends of brackets or erecting stand including PVC connection pipe 15 mm bore 450 mm long , waste coupling of PTMT, PVC waste pipe complete all as specified and directed. Note :- WHB Cat No - CNS-WHT-801 of JAGUAR or equivalant make of CERA or HINDWARE. Note :- Pedestal Cat No - CNS-WHT-301 of JAGUAR or equivalant make of CERA or HINDWARE.
M&L for 10mm thick vitrified light shade polished ceramic tiles,area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for 10mm thick vitrified light shade polished ceramic tiles, area of each tile not exceeding 0.36 sqm, in skirtings/ dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick cement plaster backing coat in CM 1:4 complete all as specified and as directed.
S&F Hasp & staple 100 mm size aluminium anodised fixed with screws complete all as specified and directed.
S&F continuous (piano) hinges 30 mm width of flap, brass, bright finish or electrogalvanised complete all as specified and directed.
S&F 40mm dia cupboard knobs fixed with nuts screws and washers of brass polished complete all as specified and directed.
S&F mild steel flat iron as in hold fast complete all as specified.
S&F Mild steel, plain, black sheet 1.60mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required and complete all as specified and as directed.
Cutting holes in brickwall builtin cement mortar depth of embedded portion of holdfast exc halfbrick but not exc one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any kind of soil complete all as specified and as directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation etc or wells cess pits manholes n.exc 10 Sqm on plan and getting out in Hard and dense soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 (Using 40mm stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L for hard core of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface using broken stone/boulders all as specified
M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) 100mm thick as in sub base floor laid in panels and finished top even and fair without using extra cement complete all as specified and as directed.
M&L for 40mm thick Plain Cement concrete type B-1, 1:2:4 (20mm graded aggregate) Laid in base of flooring complete all as specified and as directed.
Returning filling in incl levelling watering & well ramming in layers not exc 25cm in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance exc. 50m and n exc 250 m depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
S&F for steel work in tublar column and trusses including special shaped washers etc complete using ERW or induction but welded tubes conforming to IS 1161-1979 grade SI-240 complete all as specified and as directed.
M&L 25 mm precast cement concrete coping 1:2:4 type B0 (12.5 mm graded aggrgate) set in cement, coping mortar 1:4 including all moulding and complete all as specified and directed.
Rolling and consolidating formation surfaces in cutting with power roller exc 8-12 ton capacity complete all as specified and directed.
M&L for 150mm thick soling (or sub base0 with brocken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to requied gradient and camber complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate 75mm thick concrete as in sub base of paving complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 as in base to chequered tiles complete all as specified and directed.
M&L for Chequered cement concrete tiles with grey cement and pigment of size 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 15 mm thick screed in CM 1:6 complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS-15658-2006 of 80mm thickness M-40 grade complete all as specified and directed.
M&L for sand fillingunder floor or in foundations including watering and consolidation complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar 200mm dia complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar 150mm dia complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 200mm dia pipe complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150mm dia pipe complete all as specified and directed.
M&L for SWG drain pipes grade 'A' of 200mm internal dia laid in trenches and jointed in cement mortar 1:1 complete all as specified and directed.
M&L for SWG drain pipes grade 'A' of 150mm internal dia laid in trenches and jointed in cement mortar 1:1 complete all as specified and directed.
S&F for PVC (SWR) gully trap of 125/110mm dia set and jointing with solvent cement complete all as specified and directed.
Demolition of brick/stone masonry work built in cement mortar including all quions, arches, pillars etc complete all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6M mean radius built in CM 1:6 as in manhole etc complete all as specified and directed.
M&L for Construction of RCC Septic tank With Upflow Filter designed to carry sewage and sullage water, excavation in any type ofdesigned to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete for 150 users complete all as specified and directed.
M&L for Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 4.5 M effective depth (Note : Soak pits must to be constructed in pair for each septic tank.) complete all as specified and directed.
M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLSH unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 with ISI marked (for phase, neutral and earth) in and including non-metallic rigid PVC conduit medium grade with ISI Mark of minimum 20mm dia and all conduit accessories concealed including cutting/ chases in wall/ ceiling/ fixed to roof/ truss/ columns, etc., and including factory made branded make embossed galvanised steel pressed terminal boxes alongwith suitable size modular cover plates with frames for fixing modular switches and sockets, fan regulators, etc., of suitable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following :- Note: (i) The cost of cutting chases of required width and depth for concealed conduit incl plastering making good to disturbed surface painting two coats /pop to match the existing wall is deemed to be included in the quoted rate by the contractor
(a) One light point/fan point controllled by one modular switch
(b) One three pin switch socket 6 Amps outlet on same board.
(c) One three pin switch socket 6 Amps outlet on independent board.
(d) One light point controlled by two nos of two way switches.
All as per Sl item No.186 here in before, but for One Bell point controlled by one, bell push complete all as specified & directed by Engr in Charge.
All as per item No 186 here in before but with cable 2.5 sqmm multi stranded copper FRLSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor FRLSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified
M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLSH unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 with ISI marked (for phase, neutral and earth) in and including non-metallic rigid PVC conduit medium grade with ISI Mark of minimum 20mm dia and all conduit accessories on surface/ wall/ ceiling and including factory made branded make embossed galvanised steel pressed terminal boxes alongwith suitable size modular cover plates with frames for fixing modular switches and sockets, fan regulators, etc., of suitable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following :- Note: (i) The cost of cutting chases of required width and depth for concealed conduit incl plastering making good to disturbed surface painting two coats /pop to match the existing wall is deemed to be included in the quoted rate by the contractor
(a) One light point/fan point controllled by one modular switch
(b) One three pin switch socket 6 Amps outlet on same board.
(c) One three pin switch socket 6 Amps outlet on independent board.
(d) One light point controlled by two nos of two way switches.
All as per Sl item No 189 here in before, but for One Bell point controlled by one, bell push complete all as specified & directed by Engr in Charge.
All as per item No 189 here in before but with cable 2.5 sqmm multi stranded copper FRLSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor FRLSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified
S&F Modular switch 1 way 6A , 1-module all as specified and directed.
S&F Modular switch 2 way 6A,1 module complete all as specified and directed by the engineer-in-charge.
S&F Modular Bell push 6A 1 module complete all as specified and directed by the engineer-in-charge.
S&F Modular switch 1 way 16A with indicator, 1-module all as specified and directed.
S&F Modular socket, shuttered type, 6A - 3 pin 2 -module all as specified and as directed
S&F Modular socket, shuttered type, 6/16A - combined 2-module all as specified and as directed.
S&F Bell, Ding Dong AC. 230 volts, single pole complete all as specified and directed by the engineer-in-charge.
S&F modular Telephone socket outlet fixed in wall/surface complete all as specified and directed.
S&F Rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
S&F modular TV CO-Axial socket outlet fixed in wall/surface complete all as specified and directed.
S&F 3 pin, 6 A, 250 V ceiling rose conforming to IS 371: 1999 and having terminal capacity 3 X 1.5 mm² with IK 04 and IP 20 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S&F ceiling fans complete with blades,copper winding, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery not less than 210 CFM with service value more than equal to (≥) 6.00, BEE Five star rated with brushless direct current motor (BLDC) white colour incl suitable fixing arrengment and fan hook for fixing of fan complete all as specified and directed. Make:Gold Medal cat part no.SCFS 500748/Bajaj Cat part No:ENERGOS 28/ Crompton Cat part No:ENERGION RIVIRA/Havells Cat part No:PRO 28BLDC, etc.
Supply and fix exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm sweep complete all as specified and directed. Make:Havells Cat part No:Vetil Air DX HS/ Gold Medal EFS850310 AIR MAXX/ Crompton VENTILUS250MM/ Bajaj-Maxima neo, etc.
S&F exhaust fan, metal body AC single Phase 230V of size 300 mm sweep,RPM 1200 with, copper winding,blades,rag-bolts, and frame and louvers complete including making suitable size hole in wall for fixing of fan complete all as specified and directed. Make: Havells Cat part No:Ventil air DSB / Gold Medal EFS851012 HAVAC PLUS / Crompton drift air plus300mm/ Bajaj-Supreme plus, etc.
S&F Electric water heater, storage type,vertical, single phase, electric operated, 50Hz, steel body heating element up to 2 KW capacity 25 Ltrs, BEE 5 star rated innner tank as per OEM specification with minimum 2 years warranty on over all product (inner tank ,heating element & thermostat) complete with all accessories such as safety valve, thermostate, NRV, connection piece, FRLSH multistranded copper conductor cable 3 core PVC insulated, plug top 3 pin 15 Amp , 15 mm dia, brass coupler, flexible pipe suitable to withstand upto 120 °C for hot and cold water, Anchor fastener- 04 Nos of suitable size etc. complete all as specified and as directed. Make:Crompton VERSA 25L / HAVELLS FABIA GHWAFATWB025 / Gold Medal SWMS01025VWH / Bajaj SPECTRUM15096625L.
S&F Electronic type fan regulator stepped socket type suitable for BLDC ceiling fans, suitable to work on 230 volts complete all as specified and as directed
S&F 20 W surface / wall mounted LED batten light fitting aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: Crompton CCS-100-20-65-HSL2-DP-NWH/ PHILIPS BN308CLED20S-6500L120PSUWH / WIPRO LL31-251-XXX-65AL5/Havells ENDURALINEARPROBS20WLED865PCSSIND /Bajaj-BCLAB20WCWLEDXT
S & F 10 W surface / wall mounted 2 feet LED batten light fitting input voltage range 250 V, input frequency 50Hz, efficacy not less than 100 Lumen/Watt rated life 25000 burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make:Crompton CCS-103-10-65-SL-DP-NWH/ Havells LHEXAZP7PN1W010 / PHILIPS BN021LED12S 6500K PSU GR / WIPROLL20-111-XXX-65NE3 /Bajaj-BCLAB10WLEDCWLED
M&L for fixing only in repairs LED batten 20W with 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings suitable for B22 type LED bulb complete all as specified and as directed.
S & F LED Bulb 15 W B22, BEE energy efficient rating complete all as specified and as directed.
S&F LED light fitting 10W bulkhead luminaires, efficacy not less than 100 lm/w, rated life 25000 burning hours including LED light driver holder connecting up with three core flexible copper conductor cable IP 65 out door type metal body of suitable size complete all as specified and as directed. Make: Crompton CIS-306-10-57-SL-DP-NBK/ PHILIPS WT202W LED10S CW PSU S3 PC/ HAVELLS HEXAFT10WLED857SSYMBOPC /WIPRO LW07-141-XXX-57-G1/Bajaj-BIBWP10W LED
S&F LED security light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect as specified and directed by engineer-in-charge.complete in all respect as specified and directed by engineer-in-charge. Make:Crompton CRP-409-70-57-SL-GL-NSG/ PHILIPS-URBAN EDGE-BRP501LED078CWR5CPSUS1V1 / HAVELLS-ENDURA SUNDOWN SL70WLED765PASYBOTG /WIPRO-LR09-781-XXX-57-XX/Bajaj-ZELAP86LWHPOTGSDJ72W
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F single pole & neutral, double door, metallic distribution board 12 ways suitable for flush / surface mounting with provision for DP Isolator / MCB as incomer and SP MCBs as outgoing, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. complete all as specified in and directed.
S&F 240V, 10 KA miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by the engineer-in-charge.
S&F 240V, 10 KA miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by the engineer-in-charge.
S&F RCBOs for earth leakage, overload & short- circuit protection 32 A, 230 V, 50 Hz, 2P, 100 mA rating complete all as specified in IS 12640-1 (2008) and directed by the engineer-in-charge.
S&F of sheet metal enclosure TPN DBs with 200 Amps rated bus bar of 4 way 415 volts with blank plate complete with double door complete all as specified and directed by Engr-in-Charge.
S&F of MCB three phase and neutral (TPN), 63 Amps, 415 Volts, connecting with lugs, complete all as specified and directed by Engr-in-Charge.
M & L for submain wiring using 3 runs of 6 Sq mm 1100 V grade single core FR-LSH flexible cable conforming to IS 694: 2010, with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/surface / ceiling including continous earth wire having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade PVC recessed conduits of size not less than 25 mm , including making good of disturbed surfaces of wall / ceiling / floor all complete as specified and directed by engineer-in-charge.
All as per Item No. 222 here in before above but 4 Sq mm wiring cable complete as specified and directed by engineer-in-charge.
All as per Item No.222 here in before above but 1.5 Sq mm wiring cable complete as specified and directed by engineer-in-charge.
M & L for submain wiring using 3 runs of 6 Sq mm 1100 V grade single core FR-LSH flexible cable conforming to IS 694: 2010, with ISI marking in including continous earth wire having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade PVC recessed conduits of size not less than 25 mm , including making good of disturbed surfaces of wall / ceiling / floor all complete as specified and directed by engineer-in-charge.
All as per Item No.225 here in before above but 4 Sq mm wiring cable complete as specified and directed by engineer-in-charge.
All as per Item No.225 here in before above but 1.5 Sq mm wiring cable complete as specified and directed by engineer-in-charge.
Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete all as specified and as directed.
S&F Wall mounted Fan 450 mm sweep, PVC blades with wire grill, speed regulator oscillation type including hanging on wall with the help of suitable size screws complete all as specified. Make : Havells Cat No; V3 Wall/ Bajaj Cat No; 250527 Supreme Plus AC 450MM/ Crompton Cat No: SSTORM2
Removing, refixing and connecting of existing electric meter of any type and capacity complete all as specified.
M&L for cutting of wall in required shape using machine core cutting only and making opening,at any height, fixing of suitable premoulded block of required suitable for mounting of exhaust fan including wire mesh and making good the disturbed surfaces,plastering,matching with existing colour along with hole size matching with existing colour and clearing all debris and making the work area clean all as specified and directed .Note:The quoted rate includes for all/any number of openings required at any place for proper ventilation of the site.
Supply and Fix PVC sleeve tail piece for fixing exhaust fan on the wall all as specified and directed by Engg-in-Charge.
Supply and fix metallic clamps (minium 03 mm thick) suitable for fixing of ceiling fans incl rubber bush, nut bolt, washer and cotter pin complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down ceiling/exhaust fans dismantling blades complete and deposited to MES yard complete all as specified and as directed by Engr-in-Charge.
Taking down existing unserviceable Distribution boards / AC board with MCB's any size and any type complete all as specified and as directed by Engr-in-Charge.
Taking down existing submain wiring of any size or any type complete all as specified and as directed by Engr-in-Charge.
Taking down existing earthing with GI Wire/Strip complete all as specified and as directed by Engr-in-Charge.
Taking down old unsv electric cable of any type and any size complete all as directed.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 Core, 35 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 Core, 150 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete.
Material and labour for riddle earth as in cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose complete all as specified and directed.
Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm all as specified and directed.
Cutting the existing bituminuos road/ PCC road for passing of UG Cable in road/path crossing and making good the disturbed surface of road/path to its original specification complete all as directed.
S&F GI tubing 50mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as directed.
Supply, erection & testing of electrical chimney with the following specifications:- Size: 60 cm, Shape/mounting: Box/wall mounting, Suction capacity : 1100 cum/hr Air outlet size: 150 mm, Duct size : 150 mm Duct :MOC- Stainless Steel, Duct pipe/ baffle filter: inclusive as required. Motor type: BLDC motor, 240W. Blower type: Metallic Lamp: 2 x 1.5 W, Finish: Stainless Steel, Features: Low Noise (less than 62 dB) steam auto clean Controls: Dual touch, multi speed option, motion sensor”. Make: Faber/ Hindware/ Glen/ Kaff/ Crompton
Dismantling of asbestos cement (corrugated, semi-corrugated sheets in roof covering incl ridge complete all as specified and directed
stage.html
html • 0.07 MB
technical_837517.pdf
techsummary_837517.pdf
finance_837517.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
89118Tenderdocuments.pdf
Tender Documents • 1.80 MB
BOQ_837517.xls
BOQ • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .