Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC 17 A RABINDRAPALLY P O N C PUKUR BARRACKP 24PGS NORTH | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | ₹4.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹6.0 LRejected-AOC | ₹6.0 L | L2 | Rejected-AOC L2 |
| 3 | L3₹6.1 LRejected-Finance | ₹6.1 L | L3 | Rejected-Finance L3 |
| 4 | L4₹6.2 LRejected-Finance | ₹6.2 L | L4 | Rejected-Finance L4 |
| 5 | L5₹6.2 LRejected-Finance 339 2 DIAMOND HARBAR ROAD CALCUTTA 34 700034 | KOLKATA | WEST BENGAL | 700034 | ₹6.2 L | L5 | Rejected-Finance L5 |
Tender Value
₹6.0 L
EMD Value
₹12,100
Closing Date
10 Dec 2025, 3:00 pmClosed
DIRECTOR GENERAL (ELEC)
Office of the D. G. Elec LIGHTING DEPARTMENT Kolkata Municipal Corporation 15n Nellie Sengupta Sarani Kolkata-700 087 West Bengal
DEVELOPMENT AND BEAUTIFICATION OF ROAD SIDE GARDEN,STREET LIGHT POLE WITH FITTINGS AND ALLIED WORKS IN WARD NO-51
2025_KMC_945269_1
LTG/168/51/VI/Z-II/25-26
Open Tender
Electrical Work/ Equipment
15 days
KMC WARD NO. 51
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹12,100
20 Mar 2026
18 Nov 2025
12 Dec 2025
18 Nov 2025
10 Dec 2025
18 Nov 2025
40 WATT POST TOP 5700K MAKE-MAGIK-CENTURY LED LTD. MODEL-ORBIT NEO POST TOP CAT NO-APOR040C5005
Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe,Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1) b) 4 SWG ;5.0 mtrs; 45 Kg
Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc. Erection of minipole of height 3.25 M to 5.0 M in C.C. foundation 0.46 m x 0.46 m x 0.9 m depth of 1:3:6 cement concrete with hard jhama metal/stone chips including muffing of 0.3m x0.3m x 0.3m painting the pole with 2 coats of aluminium paint over a coat red oxide.
Painting steel tubular pole including projected arm bracket with one coat of red oxide primer and two coats with.silverlac AI.paint (Scraping where necessary). Pole painting upto 5mtr. Pole
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 4 1/2.24 4
Laying through Underground Trech.(a)Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying through RCC/Hume/GI Pipe.(a)Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench FOR single, 2, 3, 3... & 4 core
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 54. 40mm heavy gauge Polythene Pipe
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Soil Excavation.Excavation of soil FOR installation of Earth Electrode and filling & ramming.FOR Morrum Soil.
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 124. 40mm GI pipe (ISI-Medium)
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe.
(H) Street lights : 5. Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland FOR upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP
S/F projected lamp bracket made 50mm dia G.I. Pipe of 1.85 M (6') in length of which 0.9M (3') In projection having .an angle of 105 degree with clamps, bolts, nuts & clamps, etc. as required .
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.
Estimated amount
Add: 9%SGST
Add: 9%CGST
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.24 MB
BOQ_2245819.xls
BOQ • 0.30 MB
form168.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid