Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.9 L+₹1,030 (0.03%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹45.3 L+₹6.4 L (16.5%)Rejected-Finance | L3 | Rejected-Finance Being Higher Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF INTERNAL DRAINAGE AND RAIN WATER HARVESTING SYSTEM IN THE VICINITY OF BUILDING No. 101, 116 AND 123 IN THE AREA OF AGE E/M HOSP UNDER GE E/M LUCKNOW
2022_MES_507519_1
GE/EM/LKO/HOSP/T-85 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
26 Mar 2022
11 Feb 2022
11 Mar 2022
11 Feb 2022
9 Mar 2022
25 Feb 2022
60 days
Amount
M&L for lowering of submersible pump and connecting lead (submercible cable ) pump to LT Pannel for the controling of pump & column pipe of suitable dia and connecting the same to the first main hole (details of non submersible pump 02 No Pumps , Sumbersible copper cable, control pannel etc for complete of the following:- ' (a) submersible pumps flow range 120 - 360 LPM, minimum 12 mtr head, 3 phase 415 V, 50 mm delivery size with CI impeller including installation with guide rail and lifting chain . (Notes -(i) Rate is included for submersible copper cable of size 3 core 4.0 Sqmm from connection panel to pump complete. (ii) MS Header of size 100 mm of length 3 Mtr long with suitable size of NRV and buttterfly valve- 2 Nos of inlet connection of size 50 mm dia and 1 Nos of outlet of dia 100 mm- 01 No complete all as specified and directed. (iii) MS pipe ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes heavy duty of size 50 mm dia from pump delivery to MS Header connection complete all as specified and directed. (iv) Discharge MS pipe medium Grade 100 mm dia from MS header to nearest manhole.)
M&L for PCC 1:2:4 type B2 (using 40 mm graded stone agregrate) as in foundation of pole including necessary form work complete all as specifies and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes, foundation etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exc. 3.0 mtr in depth for laying of cables, pipes, foundation etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Excavation in over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in over areas, exc 1.5 m but n. exc. 3.0 mtr deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in over areas, exc 3.00 m but n. exc. 4.50 mtr deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in over areas, exc 4.50 m but n. exc. 6.00 mtr deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specifies and directed.
Removing excavated material ( soils) exceeding 250m and n. exc. 500 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specifies and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specifies and directed.(Note :- Punned thickness shall only be considered for payment)
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specifies and directed.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specifies and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specifies and directed.
M&L for PCC 1:2:4 type -B1 (using 20mm graded stone aggregate) as in surface channel and drain finishing the surface even and smooth with out using extra cement complete all as specifies and directed.
M&L for PCC 1:2:4 type -B0( using 12.5mm graded stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specifies and directed.
M&L for precast cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes etc.), manhole covers, drain covers, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles including necessary form work (reinforcement measured and paid seperately) complete all as specified and directed.
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specifies and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length bent to shape required including crancking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for formwork to soffits of suspended slabs, such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick [Horizontal or sloping] for fair finished fough finished surface of faces complete complete all as specifies and directed.
M&L for RCC 1:2:4type B1 (Nominal mix) using 20 mm graded stone as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specifies and directed.
M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specifies and directed.
M & L for Add or deduct for each 25 mm girth or part thereof over or under 30cm complete all as specified and directed.
M&L Cement concrete Type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed .
M & L for cutting of existing bituminous/ concrete road/pavement of any thickness and make good with 200mm thick PCC 1:2:4 Type B1 (using 20mm graded aggregate) complete all as specified and directed.
S& F for HDPE Double wall corrugated (DWC) pipes Class SN-8, 300 mm dia and including coupler and rubber sealing ring complete conforming to IS-16098 (ISI marked) complete all as specified and directed.
M&L for plain cement concrete bed Type C2, 1:3:6 (using 40 mm graded stone aggregare), using 300 mm bore pipes including forming cradles complete all as specified and directed
M&L for plain cement concrete bed, Type C2, 1:3:6 (using 40 mm graded stone aggregare) for 300 mm bore HDPE Double corrugated pipes (DWC) including packing under, and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed ( note : to be provided for encasing pipe for 450 mm length at every 2.0 Mtr centre to centre length of pipe)
M & L for 60mm thick SFRC cover with frame of dia 600mm complete all as specified and directed
Plain PVC pipe 100 mm dia bore as per IS 12818 including lowering & jointing complete all as specified and directed.
Screened PVC pipe 100 mm dia bore as per IS 12818 including lowering & jointing complete all as specified and directed.
Bore/Drilling 200 mm dia size duct bore through any kind of soil/strata by direct rotary method up to and including 90 mtr depth complete all as specified and directed.
Reaming of bore upto 300 mm (only for recharge well) pilot bore in any kind of soil/strata including hard stone /boulder by means of direct rotary method complete all as specified and directed.
Pea Gravel packing of size 6 to 10 mm for trail bores of size to be designated by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and directed.
Development of bore wells by means of high velocity jetting together with air compressor having capacity not less than 100 PSI for pumping out mud/ dirty water complete all as specified and directed.
PVC end cap for 100 mm bore pipe complete all as specified and directed.
Plain PVC bend 87.5 for 100 mm bore pipe with nylon wiremesh for to covering one end complete all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M & L for Loose filling with aggregates with broken stone or boulders of gauge 40 to 80 mm in soakage pits, soakage wells etc complete all as specified and directed.
M & L for Plain PVC pipe 160 mm dia bore as per IS 12818 for laying in trenches or fixing to wall complete all as specified and directed.
Spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed.
M R CONSTRUCTION
Powertronix
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .