Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹73.2 L+₹2.9 L (4.17%)Rejected-Finance VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹77.3 L+₹7.0 L (9.94%)Rejected-Finance | L3 | Rejected-Finance Not being lowest |
Tender Value
₹76.2 L
EMD Value
₹1.4 L
Closing Date
17 Oct 2023, 6:00 pmClosed
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPECIAL REPAIR TO BLDG NO P-04 (16 OR QTRS) OR MD ACCN OF 874 AT ASC BN UNDER GE (NORTH) UDHAMPUR
2023_MES_617873_1
CWE/U(N)-70/2023-24
Open Tender
Civil Works
Item Rate
180 days
Udhampur
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (NORTH) UDHAMPUR
₹1.4 L
7 Dec 2023
8 Sept 2023
24 Oct 2023
8 Sept 2023
17 Oct 2023
30 Sept 2023
9 Sept 2023 - 25 Sept 2023
Amount
Chipping/removing loose concrete upto reinforcement bars, without damaging the reinforcement, removing all loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc., complete all as specified and as directed.
Removing all loose scale and corrosion deposits of the exposed corroded steel including surface preparation. Corroded steel should be cleaned all around including the back of exposed steel bars and removing all the loose concrete around the reinforcement with the clearance as recommended by the manufacturer of rust remover, then applying rust remover with brush by complete wetting the rusted material surface by rust remover & leaving for 24 Hrs and thereafter surface preparation of coated bars and applying 2nd coat of the rust remover & leaving the same for the specific period as per manufacturer's instructions and further again preparing and cleaning the steel surfaces for treatment, complete al as specified and directed by the Engr-in-Charge, Make : Sika/ Rustoff 100/fosroc Rebacklens/BASF Emaco S420 Sika Rustoff 100/Fosroc Rebacklens/BASF Emaco S420.
Rebaring of Mild steel TMT bars 8mm to 20mm dia (as per existing provn at site) of required length with Sika Anchor Fix&3+/ fosroc lockfix/equivalent in BASF wherever required in RCC members including power drilling, cleaning of holes then rebar should be inserted in the holes that should b filled with epoxy as mentioned above to ensure the bond as per manufacture instructions, complete for the 8/10/12/16/20mm diameter of TMT bars as per site requirement & as directed by Engr-In-Charge. (Where ever required necessary welding of rebar’s shall also be done with main reinforcement without any extra cost).
CORROSION RESISTANCE COATING: M&L for applying passivator/anti corrosion coating to the prepared surface of item 2 above. The material shall be cement base polymer modified coating for corrosion protection and shall be applied as per manufacture instructions. Make: Sika Armatec 108/Fosroc Nito cote AP-35/equivalent in BASF. Note: Site for application is at various locations and height varies upto 15m. Proper stable scaffolding is must for working and is included in the rate quoted by the contractor.
Preparation of old RCC/concrete surface and applying a coat of two components solvent free epoxy bonding agent using brush after cleaning of surface from all dust or laitance all as per manufacturer instructions and as directed by Engr-In-Charge. Mak: Sika 32Lp/Fosroc Nitobond Ep/equivalent in BSAF. Note: Site for application is at various locations and height varies upto 15m. Proper stable scaffolding is must for working and is included in the rate quoted by the contractor.
PATCH WORK FOR INSUFFICIENT CONCRETE COVER OF SOFFIT AREA OF CONCRETE- Providing and applying ready to use single component high strength polymer modified cementitious repair mortar 25 mm thick with water/powder ratio as specified by manufacturer so as to achieve the following parameter:- (i)28 days compressive strength >=50N/mm2 (ii)Flexture strength at 28 days>= 5N mm2. Make: Sikatop 122 HS/Fosroc Nito mortars/or equivalent in BASF. Note: Site for application is at various locations and height varies upto 15m. Proper stable scaffolding is must for working and is included in the rate quoted by the contractor.
CURING COMPOUND- Applying high efficiency water based film forming curing compound over the fresh concrete/cementitious surface to form a continuous non-penetrating coating, providing a barrier to moisture moss ensuring more efficient cement hydration improved durability and reduced shrinkage. The compound shall be applied by sprayer only as per manufacturer instructions to ensure complete and proper coverage. Pump pressure should be maintained to give an even fine spray and Finish as per the manufacturer's specification. Make: Fosroc Concure WB Sika Antisol EWP or equivalent on FOSROC/BASF.
Making V groove of 10mm wide and 30mm deep or upto the extend of crack present at site over crack line using electricity operated angle grinder with diamond concrete saw blade and cleaning it by air blower. The groove shall be cut on the concrete surface along the crack over beam or column to be repaired, there after sealing of exposed ‘V’ grove with solvent –free, moisture tolerant, thixotropic, two part structural adhesive and epoxy repair mortar cum surface leveling mortar as per manufacturer's instructions and as directed by Engr-In-Charge. Make: Sika Sikagard 694 F(I)Fosroc Nito cote-VF or equivalent in BASF.
Taking down cement plaster/terrazo plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
10mm thick plastering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement,complete all as specified and as directed.
15mm thick plastering in cement mortar 1:6 on stone masonry surfaces or other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified and as directed.
5mm thick plastering in cement mortar 1:3 on concrete surfaces of ceiling, surface finished even and smooth without using extra cement, complete all as specified and as directed.
Preparation of new plastered surfaces of wall by applying 1 to 1.2mm thick Attek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of oil emulsion distemper over one coat of alkali-resistant priming paint, complete all as specified and as directed.
Preparation of old treated/old plastered surfaces of wall by and applying 1 to 1.2mm thick Attek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of oil emulsion distemper over one coat of alkali-resistant priming paint, after complete removal of existing treatment,complete all as specified and as directed.
Preparation of new plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and as directed.
Preparation of old treated/old plastered surfaces of ceiling and applying two coats of white wash, after complete removal of existing treatment, complete all as specified and as directed.
Preparation of new plastered surfaces of wall and applying two coats of cement base paint over one coat of alkali-resistant priming paint including scafolding, cleaning and curing etc., complete all as specified and as directed.
Preparation of old treated/old plastered surfaces of wall and applying two coats of cement base paint over one coat of alkali-resistant priming paint including scafolding, cleaning and curing etc., after complete removal of existing treatment, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. , complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Non skid, light coloured, ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic tiles 350x250mm or 450 x 350 mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, including 10mm thick backing layer of cement mortar in 1:3 to receive tiles in vertical surfaces, complete all as specified and as directed by Engr-in-Charge.
Machine cut Udaipur green marble stone slab flooring, 15-20 mm thick as in shelves and the likr, laid with grey cement slurry and jointed in white cement with pigment to match the shade of slab, complete all as specified and as directed.
Machine cut kota stone slab flooring 18-20mm thick over and incl screed bed or bedding layer 15mm thick in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab in floor including rubbing and polishing mirror finish complete, all as specified and as directed.
Machine cut kota stone 18-20mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 10 mm thick rendering in cement mortar 1:3 as in backing coat for laying wall tiles, complete all as specified and as directed.
Makrana white marble 18-20 mm thick machine cut not exc 100mm wide strip of, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 15 mm thick CM 1:4 mortar backing for fixing the stone slab, complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 28 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges 100mm, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges 100mm, lock strike plate etc. complete, of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified.
Mild steel work as in bands, straps, supports or stays for rain water, vantilating pipes including bolts, if required, bolt hooks (stay), heavy for large gates; hook and pintle hinges; large hasp and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles, conforming to Fe-290 grade-E-165, complete all as specified.
Plain cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads, exc 1.5 sqm, complete all as specified.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including two coats of synthetic enamel paint over a coat red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including two coats of synthetic enamel paint over a coat red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed.
19/20mm thick block board, grade 2 quaility, interior grade, both side decorative with 10mm thick 1st class soft wood beading on edges with solution, complete all as specified and as directed.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified and as directed.
4 lever locks for cupboaud/drawers of size 75mm and fixed, complete all as specified and as directed. Make: Harrison/Godrej/Link
Magnetic catcher of size 50 x 25 mm fixed with stainless steel screws, suitable for cupboard & rubber wood shutter complete all as specified and as directed.
150mm size hasp & staple, aluminium, safety type, including bolt to hinge plate and fixed with screws, complete all as specified and as directed.
Stainless steel handle, fancy type, 150mm fixed with stainless steel screw complete all as specified and as directed. Make: NU-LITE/CROWN/EURO/OXFORD/ GLOBAL/QUALITY
Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site complete all as specified.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified and as directed.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed.
3 mm thick figured glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each panecomplete all as specified and as directed.
250 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by Engr-in-Charge.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm size extruded aluminium alloy handles (ISI Marked), fabricated type., anodised, complete all as specified and directed.
100mm butt hinges, medium weight, cold rolled mild steel all as complete all as specified and directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. (ISI Mark)
1st Class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete all as specified and as directed.
Drapery rod (MS conduit) of dia not less than 25 mm having a corrugated virgin PVC extrusion on it & finials of approved shade with standard MS powder coated/ brackets, fixed to walls with rawl plugs and steel screws as in repairs complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, but except brick complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
25mm thick plain cement concrete 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as in levelling course, rough finished, complete all as specified and as directed.
50 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
Taking down eaves gutters and and rain water pipes (any size or pattern ), including all fittings incl removal of store and sold to contractor through credit.
Cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), dia of outlet 75mm fixed in repairs, complete all as specified and as directed.
Cast iron nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), dia of outlet 75mm, fixed in repairs, complete all as specified and as directed.
Salt-glazed stoneware gully traps, size 150 x 150 mm, square or round mouthed, type 'P', including setting and jointing to drains with cement mortar 1:1, fixed in repairs, including demolition of old unserviceable gully traps complete all as specified (ISI Marks).
100mm Cast iron `P' or `S' traps , complete all as specified and as directed.(ISI Mark)
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 100mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 75mm bore, complete all as specified and as directed.
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron bends (any radius) with duck’s foot or heel rest, bore of pipe 100mm, fixed in repair, complete all as specified and as directed.
Cast iron bends (any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 75mm, fixed in repair,complete all as specified and as directed.
75mm cast iron cowls as in repairs complete all as specified and as directed.
Cast iron bends (any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 100mm, fixed in repair,complete all as specified and as directed.
32mm bore galvanised steel water tubing medium grade (ISI Marked) fixed in sunken floor as spout, complete all as specified and as directed.
Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge.
110 mm bore PVC SWR bends and fixed solvent etc complete all specified and as Directed (ISI Marked)
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) fixed in repairs, complete all as specified.
Grating doom 125mm dia of PTMT (Minimum weight 40gms) fixed in repairs, complete all as specified.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 incl PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware fixed in repairs complete, all as specified and as directed.
Brass chromium plated centre hole basin mixer 15 mm bore for mixing hot & cold water screwed down for iron pipe, fixing in repair complete all as specified.
Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and and wooden/plastic cleats (minimum weight 190 gms) fixed on walls, fixed in repairs, complete all as specified.
Towel ring of PTMT fixed with and including chromium plated brass screws and and wooden/plastic cleats (minimum weight 90 gms) fixed on walls, fixed in repairs, complete all as specified.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by Engr-in-Charge.
Sinks made of stainless steel with draining board, made out of 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar including fixing cantilever brackets connecting union to pipe and 32mm dia GI pipe duly painted upto Nihani Trap or Floor trap complete as directed at site, overall size 915mmx460mm bowl size 410mm x 330mm x160mm, in repair complete all as specified and as directed.
Plate rack made of 1 mm thick stainless steel, of size 600 x 750X250mm including fixing as per manufacturers instruction complete all as specified and as directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for roof padding, including roof tiles etc complete all as specified and as directed.
Supply only Integral water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 15mm thick screeding in CM (1:4) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately) and applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm complete all as specified and as directed by Engr-in-Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Preparation of roof surfaces of any description over 10cm width or girth and applying two coats aluminium paint, complete all as specified.
Pre-cast RCC cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed.
TMT mild steel bars, 6mm to 8mmm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and includingMS wire (annealed not less than 0.9mm dia), complete all as specified and as directed.
Soap dish, mild steel chromium plated, fixed in repairs complete all as specified and as directed. Make: Jaquar cat Part No ACN 1131FN or equivalent make as mentioned in Particular Specifications.
Corner glass shelf with chromium plated guard rails, fixed in repairs complete all as specified and as directed. Make: Jaquar cat Part No ACN 1173N or equivalent make as mentioned in Particular Specifications.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Fixing only 15 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Fixing only 20 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, concealed in wall and ceiling or laid in floor complete with all fittings ( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank (white colour), two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Brass Chromium plated over head shower rose of dia 125mm with swivel joint fixed to pipe or union of 15mm bore, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, complete all as specified and as directed by Engr-in-Charge.
Stop valves / Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15/20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified & directed.
Removing excavated material (soils) to a distance n.exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Hard core of gauge not exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified & directed.
75mm thick PCC 1:4:8 Type D2 using 40 mm graded stone aggregates as in foundations filling and mass concrete., complete all as specified and as direceted.
Sand cushioning under floors including watering and consolidation complete all as specified and as direceted.
Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment. Shape shall be approved by GE.
Machine pressed (factory made) Precast cement concrete 1:2:4 mix type B-1 kerb stone of size 300mm x 300mm x 100mm and setting in cement mortar 1:4, complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface as in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat section) including distance pieces conforming to Fe 410-W, Gde E-250 Quality 'A', complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as direceted.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as direceted.
Plain cement concrete 1:3:6, nominal mix, type C-0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge. Note: Serviceable light fittings any type and wattage shall be kept in safe custody for refixing.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 126 above but for one ceiling fan point with and including surface PVC conduit on ceiling.
Description all as per item No 126 above but for bell/buzzer on independent board.
Description all as per item above No 126 but one 3/5 pin 5 Amp socket outlet on independent board .
Description all as per item No 126 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly.
Description all as per item above No 126 but one light point controlled by two two way switches.
Description all as per item above No 126 but one 3/5 pin 5 Amp socket outlet on same board .
Switch piano, single pole, one way, 5 Amp, piano type, complete all as specified & directed.
Switch piano , single pole, two way, 5 Amp, piano type, complete all as specified & directed.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 6 pin, 6 & 16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,with all acessories, complete all as specified and as directed.
Bell push piano type 5 Amps 230 volts, 1 way complete all as specified.
Stepped type fan regulator 120W, 230V 50 C/S, electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed.
Refixing only LED lights fitting 5 Watt to 20 Watt any pattern and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
E-lite LED curve luminaire, 20 watt with wide angle profile, and connecting up with flexible copper conductor cable of suitable size , complete all as specified and directed. Make : Havells cat Pt No LHEXBYPNIN1W020, or equivalent in performance of makes as specified in particular specifications.
E-lite LED curve luminaire, 10 watt with wide angle profile, and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells cat Pt No LHEXBYPNIN1W010, or equivalent in performance of makes as specified in particular specifications.
Slim linear LED lighting fixture 5 Watt LED Batten, For mirror light purpose, complete making all connection using 1.5 sqmm copper conductor multi stand PVC insulated 3 core flexible cable from ceiling rose to fitting complete all as specified & directed.
9/10 watt LED Bulk Head Light energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED (Make of LED shall be CREE/Nichia/Osram) complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 148 Contd … (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Taking down MCB DBs with MCBs for reuse or credit as directed.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with MCCB as incommer and MCBs as outgoings with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,incl taking down existing DBs, complete all as specified and as directed by Engr-in-Charge.
MCCB 4 pole, 415 volts 160 Amps with breaking capacity 16 KA complete all as specified and as directed by Engineer-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Single phase electric energy meter box made of polycarbonate body with locking arrangement, complete all as specied and as directed.
Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as per the directions of Engr-in-Charge.
Angular holder with rectangular base including round block, complete all as specified.
Led bulb 15W, 230 Volts AC and fixed complete all as specified.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
9/10 watt LED Bulk Head Light energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED (Make of LED shall be CREE/Nichia/Osram) complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 32mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as per the direction of Engr-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable, complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles, complete all as specified and as directed by Engr-in-Charge.
Modular TV socket outlet single with inner and outer cover strip required moduele including TV cable required length form roof complete all as specified and directed by Enger In charge.
Removing and refixing only LED lights fitting 5W to 20W, 220V, AC decorative box type with driver, holder including LED tube light C & S Make connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Removing and refixing water heater, 25 ltr capacity 220V, AC single phase including nut bolt, copper conductor cable of suitable size, one coat of synthetic enamel white spray painting complete all as specified and directed.
KALSOTRA CONSTRUCTION CO
jyoti parkash sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .