Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-Finance 98 PANIYARE PURWA MAKRAND NAGAR SARAIMEERA KANNAUJ KANNAUJ UTTAR PRADESH 209726 | KANNAUJ | UTTAR PRADESH | 209726 | L1 | Accepted-Finance Accepted | |
| 2 | L2₹1.2 L+₹4,700 (4.07%)Accepted-Finance AASHIYANA SECTOR N 304 KILA CHAURAHA KANPUR ROAD AASHIYANA LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L2 | Accepted-Finance Accepted | |
| 3 | L3₹1.4 L+₹24,250 (21.0%)Accepted-Finance | L3 | Accepted-Finance Accepted |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
9 Jul 2021, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer, ETD-II, Aligarh, UPPTCL 132 KV Substation Sarsol compound complex, Sarsol, GT road, Aligarh 202002
Replacement of relay panels, retrofitting of relays at 220KV substation Atrauli and 220/132 KV substation Sikandra Rao under ETD-II, Aligarh.
2021_UPTCL_598974_1
ETD(A)/TD-04/2021-22
Open Tender
Electrical Works
Item Rate
15 days
Atrauli
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer
₹2,000
12 Jul 2021
25 Jun 2021
9 Jul 2021
25 Jun 2021
9 Jul 2021
25 Jun 2021
60 days
Amount
Distance protection panel replacment work of 220KV DC Atrauli-Aligarh line (I&II circuits).
Dismantling of distance protection panels by removing of terminations of cables ,opening nut and bolt, earthing from existing distance protection panels at following substations. (a) 220KV substation Atrauli.............2No.
Preparation of Inter connection diagram and cable schedule as per old panel drawings and new panel drawing for making connection in new panel.
Installation and erection of new distance protection panel at following substations as per technical specification and drawing including shifting of panel from store to site . Work also includes earthing of panel as per drawing . (a) 220KV substation Atrauli.............2No. .
Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or junction box wherever required fixing of gland providing ferruels and no of each core of cable and its termination with dressing and binding and all associated work to complete the job satisfactorily. The glands supplied by firm with the equipment shall be used by the contractor, if moe glands are required for completion of work, the same shall be arranged by the contractor without any extra cost.
Laying and dressing of control cable in trenches at 220KV substation Atrauli and 132KV Substation Sikandra Rao as per requirement after removal of trench covers as per cable schedule including clamping with 23x3 MM alu. Stip and G.I. Nut and Bolts including cutting, peeling and inter connecting at both ends.
2x2.5 Sq.MM
4x2.5 Sq.MM
4x2.5 Sq.MM
Safe carriage of 1no. distance protection panel from 220KV subsation Chandausi to 220KV Substation Atrauli with distance of 90Km including risk of transit and loading and unloading at both end.
Retrofitting of 86 Relay of 132KV Boner feeder relay panel at 220KV substation Atrauli .
Opening of terminations of control cables at existing defected 86 132KV Boner relay panel . Removal of defected relays & housing of old relay from panel cabinet.
Preparation of panel front by cutting & adding new backlight new ms sheet for replacement of housing of new numerical relay for proper mounting on panel front & covering with beading
Prepartion of interconnection drawing & modification in panel wiring for new numerical relay instalation on panel in place of electromechanical relays. Work includes submission of drawing, connection /termination as approved by department.
Fixing of 86 relay (to be provided by department) at 132KV Boner relay panel as techincal specification including termination work.
Retrofitting of Distance protection relay in distance protection panel of 132KV Akrabad bay at 132KV Substation Sikandra Rao.
Opening of terminations of control cables at existing 220KV Atrauli-Aligarh-II line distance protection panel for removing distance protection relay . Removal of distance protetion relays & housing of old relay from panel cabinet and carriage of same to 132KV Substation Sikandra rao.
Preparation of panel front of 132KV Sikandra rao-Akrabad line by cutting & adding new backlight new ms sheet for replacement of housing of new numerical relay for proper mounting on panel front & covering with beading .
Prepartion of interconnection drawing & modification in panel wiring for new numerical relay instalation on panel in place of defected distance protection relay relays. Work includes submission of drawing, connection /termination as approved by department.
Fixing of distance protetion relays (dismantled from 220KV Atrauli-Aligarh-II line relay panel) at 132KV Sikandra rao-Akrabad line relay panel as techincal specification including termination work.
Addition of 1No. 132KV bay in RTU of existing SCADA system for sending digital/ Anolog datas to SLDC lucknow as per requiement of UPPTCL at 220KV Substation Sikandra Rao.
SMV POWER SOLUTION
Vertex india
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .