Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹73,000
Closing Date
1 May 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
office of the S.E., EUDC-II, Sec-18, Noida.
Replacment of Damged Pole Wire etc Under EUDD-3 Noida
2024_PVVNL_922298_2
Replacment of Damged Pole Wire etc Under EUDD-3 Noida
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
Attached in DOC
2 documents required · 2 mandatory
₹3,540
office of the S.E., EUDC-II, Sec-18, Noida.
₹73,000
16 May 2024
20 Apr 2024
1 May 2024
20 Apr 2024
1 May 2024
20 Apr 2024
Amount
33 @ 11 dsoh fo|qr midsUnz] lsDVj&126] uks,Mk ls mftZr {ks=] xzke& jk;iqj] esa vfrfjDr ,y-Vh- lfdZV gsrq 2-5 fd0eh0 ,y-Vh- ,-ch-lh- dsfcy Mkyus dk dk;Z
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 4
PCC 8.5Mtr Long Pole
LT AB Cable 3x120+1x95+1x16sqmm
Supply and Errection of the ABOVE Following material AND SUPPLY & ERRECTION OF THE FOLLOWING MATERIAL for completing the work as per RESPO.
Laying, spreading, lifting and final sagging of LT AB Cable 3x120sqmm in accordance with Line chart includidng binding and fixing of all accessories as per site requirement.
Providing and Fixing of LT PVC Cable 1x35sqmm as per site requirement
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) PCC 8.5 Mtr Long Pole.
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) 11M Long ST/PCC Pole and 8.5 Mtr Long PCC Pole
Providing and Fixing of Suspension Clamp with I hook as per site requirement
Providing and Fixing of End Clamp with I hook as per site requirement
Providing and Fixing of Pad Lock and Clamps for Distribution Box as per site requirement
Providing and Fixing of J Hook for Distribution Box as per site requirement
Providing and Fixing of Pierceing Clamp for Distribution Box as per site requirement
Providing and Fixing of Three Phase Distribution Box as per site requirement (GTP Approved.)
11KV HORIZONTAL TPMO SET WITH COMPELTE ACCESSORIES leLr lkexzh o dk;Z dk;Znk;h laLFkk }kjk lEikfnr djk;k tkuk gS iw.kZ VuZdh ijA
Supply of Horizontal TPMO SET with complete Structure and accessories with 02 Nos. 75mm X 40mm X 2800mm galvanised mounting channels as per Approved GTP and specifications.
Mounting and installation of above Horizontal TPMO Set with Fabrication of 02 Nos. 75mm X 40mm X 2800mm galvanised mounting channels complete with providing and fixing ofgalvanised holding clamps, heavy duty GI pipe 25mm dia with operating handle mechanism, nuts & bolts with supporting channel etc. by the contractor with complete connections in all respect.
SUPPLY AND INSTALLATION OF 50 Nos. L.T. FEEDER PANELS (MAIN PANEL) ON TURN-KEY BASIS.
Supply and Installation of new L.T. Feeder Pillar (Main Pannel) as per following specification with all relevant certificate:- 1) LT Feeder Pillar Box (Main Pannel) shall be of 14 SWG HR sheet, having (4) doors, two in front and 2 doors on back side of 14 SWG HR sheet. Doors should have proper locking arrangements with providing crome locks of standard make. It should have a canopy on top in order to prevent it from water ingress in rains. The doors of box should be welded with robust quality hinges and PVC Gasket with provision of 3 hinges on each door and handle on each door with PVC Gasket.The periphery of door of the LT Feeder Pillar Box (Main Pannel) shall be provided with lining of rubber/ PVC to prevent entry of rain, insects, lizards, rats etc. so as to make it vermin proof. 2) The dimension of Feeder Pillar Box (Main Pannel) 5(Height) X 3.5(Width) X 2.5(Depth) Feet (With Canopy). 3) 04 Nos. Bus Bar insulation coated made of aluminum for red, yellow, blue & neutral phases suitable for 400 Amp. 4) 01 No. ISOLATOR SWITCH of 400 Amp. of L&T / Havell’s / ABB make for disconnecting of Supply. 5) 24 Nos. KIT KAT Fuse of 415V, 200 Amp. each capacity tested as per IS shall be provided with 8 Nos. on each phase so as to cater to 8 Nos. 3 Phase connections of branch pannel. 6) Aluminum crimping lugs of size 400 / 240 Sq.mm. and proper size thimbles shall be provided for safe termination of incomer as well as individual service cable as per qty. requirement. 7) Bakelite sheet shall be provided on the base of channel meant for mounting the Kit Kats. 8) All nuts, bolts & washers used shall be electro galvanized. 9) The height of erected feeder pillar box (Main Pannel) approx. 01 feet from the earth on powder coating base of angle iron size 40x40x5mm frame with 04 nos. legs of 1.6 feet each (06 inch grount of angle on earth bottam, 6 inch grout in plinth and 6 inch gap in pannel base and plinth) 10) Grouting & Plinth of Feeder Pillar Box (Main Pannel) as per site requirement complete in all respects. 11) The panel case consisting of door and roof (canopy) shall be powder coated with chemical process (weather proof) of light green color both inside and outside. Before painting, the sun faces shall be thoroughly cleaned from dust, grease and rust. Identification no. shall be written as per direction. 12) Sundry item.
Disconncetion of all incoming & outging connection from pannel as per requirement.
Reconncetion of all incoming & outging connection from pannel after replacement as per requirement.
Dismantling of damaged L.T. Main Feeder Pannel from earth on work site.
Carriage of above dismantled Pannel from works site to JE store / central store & proper stacking with loading & unloading.
Making of plinth with Ist class brick work in the size of 1100(length)x700(width) , 150 mm below the earth and 300 mm above the earth in 1::4 (Cement,Sand) mortar with plaster outer suface of Plinth, all material and work for using in plinth will be provided by the contractor.
Installation of above new L.T. Main Feeder Pannel in place of damgaged L.T. Main Feeder Pannel with required items complete in all respect.
Providing & fixing of 3.5c x 240 sq mm aluminium armoured XLPE L.T PVC cable or as per site requirement and as per approved PVVNL technical specification for installation above Pannels as per requirement. (GTP Approved)
Providing of chemical earthing for above new L.T. Feeder Pillar (Main Pannel) and installation as per following :-
Chemical earthing with earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 k.g. x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32mmx6mm.
Replacement of Damage Distribution Tranformer Plinth 20 Nos at All 19 Nos Sub Station under EUDD-III Noida
Construction of New Plinth for Distribution Transformers, The size of plinth shall be 2M long 2m wide and the height of the plinth shall be 1.50 M with 20 cm. thick top slab with 02 no. 125x65mm MS channel 2 M long embedded in it. The repairing work includes excavation of earth, laying of brick ballast pad for foundation brickwork, CC and plastering and proper curing. The ratio of cement/course sand/fine sand/brick ballast/stone grit as per RESPO schedule including unloading and Loading of the transformer with complete work in all respect. (All work and material in the scope of the Contractor)
M/S GOVIND ENTERPRISES
M/s Ashu Brothers
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .