Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAdmitted-Finance | ₹44.6 L | L1 | Admitted-Finance |
| 2 | L2₹49.0 L+₹4.3 L (9.71%)Admitted-Finance | ₹49.0 L+₹4.3 L (9.71%) | L2 | Admitted-Finance |
| 3 | L3₹50.0 L+₹5.4 L (12.1%)Admitted-Finance | ₹50.0 L+₹5.4 L (12.1%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not recommended due to No in WLR QE Mar 2026 of HQ CE (AF) Bengaluru |
| Sl No | Description | Qty | Unit | GVR ENGINEERING WORKS L2 | Sri Lakshmi Enterprises L3 | m. surender singh L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling old ACSR conductor of any size from over head lines complete all as specified and as directed. | 3.1 | Qtl | 400 ₹1,240 | 279 ₹864.9 Lowest | 4,500 ₹13,950 |
| 2.00 | Dismantling old Cross-arms of MS channel including clamps nuts and bolts or angle sections etc. of any size from over head lines complete all as specified and as directed. | 1.25 | Qtl | 160 ₹200 | 126 ₹157.5 Lowest | 4,500 ₹5,625 |
| 3.00 | Dismantling old insulators of any type and size from over head lines complete all as specified and as directed. | 82 | Each | 10 ₹820 | 4.59 ₹376.38 Lowest | 99 ₹8,118 |
| 4.00 | Dismantling old service wire of any type and size from over head lines complete all as specified and as directed. | 2,440 | RM | 5 ₹12,200 | 4.59 ₹11,199.6 Lowest | 9 ₹21,960 |
| 5.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq. mm 3.5 core in trenches/ fixed to walls/ poles etc. complete all as specified and as directed. | 750 | RM | 965 ₹7,23,750 | 1,089 ₹8,16,750 | 819 ₹6,14,250 Lowest |
| 6.00 | All as per item No.5 but 95 Sqmm x 3.5 Core complete all as specified and as directed. | 350 | RM | 815 ₹2,85,250 | 891 ₹3,11,850 | 702 ₹2,45,700 Lowest |
| 7.00 | All as per item No.5 but 50 Sqmm x 3.5 Core complete all as specified and as directed. | 385 | RM | 495 ₹1,90,575 | 495 ₹1,90,575 | 396 ₹1,52,460 Lowest |
| 8.00 | All as per item No.5 but 25 Sqmm x 3.5 Core complete all as specified and as directed. | 310 | RM | 300 ₹93,000 | 333 ₹1,03,230 | 252 ₹78,120 Lowest |
| 9.00 | All as per item No.5 but 10 Sqmm x 2 Core complete all as specified and as directed. | 6,355 | RM | 182 ₹11,56,610 | 162 ₹10,29,510 | 126 ₹8,00,730 Lowest |
| 10.00 | Supply, install, testing and commissioning of new Out door LT feeder panel, factory fabricated, CPRI tested , cubicle type, 3.15 mm thick CRCA sheet vermin proof with 3 phase and neutral Aluminium bus bar of current capacity 400A of suitable size, phase and neutral colour coded with heat shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painting with one coat of red oxide primer and two coats of powder coated paint, suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc. , including PCC foundation complete all as specified and directed and including provision of the following :-
(a) 4 Pole MCCB 320 Amp 50 Hz 415 V with rupturing capacity 36 KA,Adjustable thermal & Magnetic setting(Incoming ) - 01
(b) 4 Pole MCCB 100A 50 Hz 415 V with rupturing capacity 25 KA,Adjustable thermal & Fixed Magnetic setting - 05 Nos ( 01 Stand by for Sub Panel)
(c) Three phase Digital voltmeter 0-500 Volts with selector switch - 01 Set
(d) Three phase digital Ammeter 0-500 Amps with selector switch - 01 Set
(e) Phase Indicating lamp LED type for Red, Yellow and Blue - 01 Set | 1 | Each | 1,30,000 ₹1,30,000 Lowest | 1,89,999 ₹1,89,999 | 1,62,000 ₹1,62,000 |
Tender Value
₹44.2 L
EMD Value
₹88,500
Closing Date
14 Aug 2026, 6:00 pmClosed
GE Golconda
GE GOLCONDA LANGER HOUSE ROAD OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPL REPAIRS TO OVER HEAD CONDUCTORS TO UNDER GROUND CABLE AND CONNECTED ITEMS AT 17 DOGRA AREA AND SPECIAL REPAIRS TO LT OHT LINE TO LT UNDER GROUND CABLE OF 92 TO 99 BLOCK OF 383 MD ACCN AT 47 INF BDE UNDER GE GOLCONDA
2026_MES_778944_1
8134/E8
Open Tender
Civil Works
Item Rate
180 days
GE GOLCONDA
As per Tender
9 documents required · 9 mandatory
₹500
GE Golconda
₹88,500
Yes
1 Sept 2026
16 Jul 2026
17 Aug 2026
16 Jul 2026
14 Aug 2026
31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling old ACSR conductor of any size from over head lines complete all as specified and as directed. | - | Qtl | - | - |
| 2 | Dismantling old Cross-arms of MS channel including clamps nuts and bolts or angle sections etc. of any size from over head lines complete all as specified and as directed. | - | Qtl | - | - |
| 3 | Dismantling old insulators of any type and size from over head lines complete all as specified and as directed. | - | Each | - | - |
| 4 | Dismantling old service wire of any type and size from over head lines complete all as specified and as directed. | - | RM | - | - |
| 5 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq. mm 3.5 core in trenches/ fixed to walls/ poles etc. complete all as specified and as directed. | - | RM | - | - |
| 6 | All as per item No.5 but 95 Sqmm x 3.5 Core complete all as specified and as directed. | - | RM | - | - |
| 7 | All as per item No.5 but 50 Sqmm x 3.5 Core complete all as specified and as directed. | 385 | RM | - | - |
| 8 | All as per item No.5 but 25 Sqmm x 3.5 Core complete all as specified and as directed. | 310 | RM | - | - |
| 9 | All as per item No.5 but 10 Sqmm x 2 Core complete all as specified and as directed. | - | RM | - | - |
| 10 | Supply, install, testing and commissioning of new Out door LT feeder panel, factory fabricated, CPRI tested , cubicle type, 3.15 mm thick CRCA sheet vermin proof with 3 phase and neutral Aluminium bus bar of current capacity 400A of suitable size, phase and neutral colour coded with heat shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painting with one coat of red oxide primer and two coats of powder coated paint, suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc. , including PCC foundation complete all as specified and directed and including provision of the following :-
(a) 4 Pole MCCB 320 Amp 50 Hz 415 V with rupturing capacity 36 KA,Adjustable thermal & Magnetic setting(Incoming ) - 01
(b) 4 Pole MCCB 100A 50 Hz 415 V with rupturing capacity 25 KA,Adjustable thermal & Fixed Magnetic setting - 05 Nos ( 01 Stand by for Sub Panel)
(c) Three phase Digital voltmeter 0-500 Volts with selector switch - 01 Set
(d) Three phase digital Ammeter 0-500 Amps with selector switch - 01 Set
(e) Phase Indicating lamp LED type for Red, Yellow and Blue - 01 Set | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
8134NIT.pdf
Additional Documents • 0.33 MB
BOQ_872456.xls
BOQ • 0.23 MB
8134Tender.pdf
Tender Documents • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .