Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC 3RD FLOOR BNCCI HOUSE 23 R N MUKHERJEE ROAD KOLKATA 1 | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹24.0 L+₹3.9 L (19.4%)Rejected-Finance BANSHBARI MALDA | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹24.4 L+₹4.3 L (21.6%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
11 Nov 2020, 12:30 pmClosed
EE/BED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Construction of one Generator Room and one BMW Room at ground Floor for COVID 19 Testing Labroatory and CBNAT/ True NAT Laboratory at BSMC and H, Bankura. SITC of 250 KVA DG Set for total power backup at Natun Bhaban
2020_WBPWD_301884_1
WBPWDTE/EE/BED/NIQ_73/Q of 2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹50,000
Bankura
7 Jan 2021
15 Oct 2020
13 Nov 2020
15 Oct 2020
11 Nov 2020
16 Oct 2020
16 Oct 2020
Amount
i) Disel Engine Supply ,installation ,testing and commissioning of silent type DG set conforming to latest environment protect ion regulation for emission and noise level comprising of radiator cooled vertical multi-cylinder diesel engine equipped with flywheel having Prime Power Rating of following KVA 415 Volts at 1500 RPM ,0.8 lagging Power factor at 415 volt suitable for 50 Hz, 3 phase system & for 0.8 Load Factor and consisting of the following. Rating of DG : 250KVA Eelectric Start Diesel Engine 1500 R.P.M Turbocharged and air-to-air charge cooled ,Rediator cooled ,4 Stroke , heavy duty,power generation diesel engine as per IS1002/BS5514/ISO3046, capable of taking 10% over loading for one hour after 12 hours of continuous operation at 50 dge C the engine will be fitted complete with all following accessorise Freewheel with Freewheel housing Inlet manifold and oil bath air cleaners Gear type Lube Oil pump Lube oil Filter Electronic Fuel Injection system with injector Pump Nozzles Electronic Governor Fuel Filtter (Double bowl) Engine mounted instrument Panel fitted with and having digital display for following: Start-stop switch with key Water temperature indication Lubrication oil pressure indication Battery charging indication RPM indication Over speed indication Low lub. Oil trip indication Engine Hours indication ii) Alternator Brush less type ,Synchronous ,A.C.Generators continuously rated for 415 Volts,3 phase, 4 wire,50 HZ, 0.8 power factor (lagging) at 1500 RPM,4 Pole, screen protected ,drip proof,horizontal foot-mounted type,self-excited,self regulated with static excitation system ,Class „H“ insulation.The Alternator is capable of developing rated output & able to take 10% overload for one hour at every 12 hrs of operation. The Alternator shall confirm to IS: 4722 /BS:2613 and will be suitable for tropical condition.
iii) Starting System 12V / 24V DC starting system comprising of stsrter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator extraction ,discharging hot air in to the atmosphere as per specifications. iv) AMF Panel Supply, Installation, Testing & Commissioning of vertical floor mounting free standing, extensible on either side, compartmentalised cubical type panel board made of 14 SWG CRCA sheet suitable for 415V, 50 HZ, AC , 3 Phase and neutral system having the following features panel shall be designed to ensure that the weight of the components is adequately supported without deformation or loss in allignment. The doors of the cubicle shall be fitted with dust excluding neoprene gaskets with fastners for proper compression of the gaskets. Panel shall be multitier comparmentalised cubical type, extensible on either side and shall be treated with all anticorrosive process before painting with two coats of zine chromate primer and final approved shade of enamel paint. All the MCCBs shall be provided with extended rotary operated mechanism. Safety interlocks are toe be provided to prevent the doors of the compartments housing the MCCBs to prevent the doors to open when the MCCBs are 'ON' position. The panel shall also comprise of necessary meters, CTs, protection MCBs/HRC fuses, indication lamps relays, lifting bolts, label inscriptions (metalic engraved identification tags) describing the rating of the breakers, bus couplers, designation of the feeders etc including all other accessories, complete as per IE rules and regulations conforming to relevant IS and duly approved by the EIC incl. to comp. the same The rate shall include necessary cutting chases, and mending good damages to original finish as per direction of EIC & The panel shall have the following major components.
INCOMER 400A, 4P electrically operated, thermo-magnetic based MCCB ( make Siemens / ABB/ L&T/ Legrand) of rated service voltage upto 690V, 50 HZ with manual push buttons, indications, current sensors, CTs, etc ---- 2 nos Icu-36 KA for 1 Sec. (at 415V, 50 HZ), Ics=100% Icu thermo-magnetic S/C & O/C releases. 600A, 415V, 50HZ, 31 MVA Amps symmetrical continuous rated Tined CU busbars ( 40 mm x 10 mm for phases and 40 mm x 10 mm for neutral) Busbars shall be of continuous rated Tined Copper adequate for speciifed rated continuous and short circuit current covered by, proper graded heat shrinkable PVC sleeves (colour coded). Busbars shall be supported by suitable hylaml/DMC/SMC or compatable insulator supports. HIgh tensile bolts and springs washers are to be provided on all busbars and suitable drilled holes for connection joints. The busbars shall have a throuth fault withstand capacity of 31 MVA, RMS symmetrical for one second. the interconnections between the busbars and the circuit breakers shall be made by continuous rated Aluminium strips suitably covered by proper graded heat shrinkable colour coded PVC sleeves. The earth busbar shall run through the length of the panel and terminated at two ends.…. 1 item 400A, 4P electrically operated,Contractor ( make Siemens / ABB/ L&T/ Legrand)-- 2 No ON/OFF Iluminated Push Botton.( make Siemens / ABB/ L&T/ Legrand) --1 item Core Balance CT with earth leakage relay.--1 item 400/5-5A Dual Core cast resin type Current Transformer (MakeKappa / PWD appvd) of CL-5P10 for protection and CL-1 for metering with 15VA burden each 1 Set (3 Nos) Cast Resin Construction Type Potential Transformer 415 V/√3 : 110V/√3 with Cl - 0.1 accuracy with 100 VA burden with HRC fuses at primary and secondary for protection.(MakeKappa / PWD appvd)-- 1 Set (3 Nos) - RYB cluster type LED phase indlcation lamps.( make Siemens / ABB/ L&T/ Legrand)-- 3 No CT Operated Digital Kilowatt Meter.( make Siemens / ABB/ L&T/ Legrand)-- 1 item CT Operated Digital Load Monitor.( make Siemens / ABB/ L&T/ Legrand)-- 1 item CT Operated Digital VAF meter for Mains ( make Siemens / ABB/ L&T/ Legrand)-- 1 item
Over Voltage relay..( make Siemens / ABB/ L&T/ Legrand)-- 1 item Under Voltage relay..( make Siemens / ABB/ L&T/ Legrand)-- 1item Master Trip relay For Alternator and Engine Fault..( make Siemens / ABB/ L&T/ Legrand)-- 1 item Positive Active Power relay..( make Siemens / ABB/ L&T/ Legrand)-- 1 item AMF Controller ( make Siemens / ABB/ L&T/ Legrand)-- 1 item Supply & Installation of 1.1 KV grade 3 c x 2.5 Sq mm Cu. Unrmoured Control Cable including terminations as required. with necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. To complete the installation as per direction of EIC - 50 mm x 10 mm GI Earth busbar running along the base frame covering entire length of the panel with high tensile bolts, nuts, etc. and number of drilled holes as required for earth connection at both ends..1 item Danger Board…1 no
Base foundation for the Installation of DG ( Appx . Base Size - L-6000 mm x W-3000 mm x H-800 mm ) i) Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed (50 Sq mtr).{ Ref Page-1 Item No- 1) ii) Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge (26.32 Cu mtr).{ Ref Page-12 Item No- 13) iii) Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. (21 Cu Mtr) { Ref Page-1Item No- 2) iv) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) (a) Do - by Silver sand (foundation & plinth) (21 .39 Cu Mtr) { Ref Page-2 ,Item No- 4) v) Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. (Wall & base) (30 Sq Mtr) { Ref Page-14 ,Item No- 1) vi) Ordinary Cement concrete (mix 1:2:4) with graded stone chips....... floor as per relevant IS codes(d) With local hard blackstone variety chips (crusher broken (4.50 Cu Mtr) { Ref Page-10 ,Item No- 27) vii) Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (iv) With local hard blackstone variety chips (crusher broken) (2.70 Cu Mtr) { Ref Page-12 ,Item No- 33)
viii) Hire & labour charges for shuttering with centering and necessary staging upto 4.00 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works.(f) 25mm to 30mm Shuttering without staging in foundation.Foundation Wall PCC , Base PCC & RCC(8.60 Sq Mtr ){ Ref Page-42 ,Item No- 36) ix) Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel, I. SAIL/ TATA/RINL (0.53 MT) { Ref Page-25 ,Item No- 6) x) Brick work with 1-st class bricks in cement mortar (6:1) In foundation & plinth Wall & Steps (9.42 Mt Cu) { Ref Page-15 ,Item No- 8) xi) Artificial Stone floor ,dado,staircase etc. With cement concrete (1:2:4) with stone chips ,laid in panekls as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concetre surface and application of cement slurry before flooring works using cement @ 1.75 kg /sqm all complete including all materials and labour in ground floor 3mm thjick topping (High polishing grinding on this item is not permitted with ordinary cement ). using grey cement (ii) 25mm thick. Shade (18 Sq Mt ) { Ref Page-48 ,Item No- 6) xii) Plastering (in wall floor , ceiling etc)with sand and cement morter Including rounding off or chamferring corners as directed and raking out joints or roughening of concrete surface including throating and drip course where necessary.20 mm thick plaster (4:1) (24 Sq Mt { Ref Page-189 ,Item No- 1) xiii) Applying Exterior grade Acrylic primer of approved quality and brand on plaster or concrete surface old and new surface receive Texture(mat finish ) or smoth finish acrylic exterior emulsion paint including cleaning and preparing the surface throughly, complete. / Acrylic emulsion paint and preparing the surface throughly, complete as per manufacture specificationof the E.I.C. In ground floor. one coat (24 Sq Mt { Ref Page-196 ,Item No- 8) xiv) Protective and decorative Acrylic Exterior emulsion Paint of approved quality as per manufacturer's specification and as per direction of Engineer -in Charge to be applied over acrylic Primer as required. The rates includes the cost of materials, labour, scaffolding and all others incidental charges but excluding and all others incidental charges but excluding the cost of primer.c) Super Protective 100% Acrylic Emulsion (24 Sq Mt { Ref Page-197 ,Item No- 18)
Exhaust System Supply & Installation of MS black exhaust pipe of 150 dia dult connected with residential type silencer. Pipe to be painted with heat resistant paint after the fabrication. The rate shall be inclusive of flanges, fire fly/ asbestos gaskets, hardware, glass wool and aluminium sheet cladding etc. complete. i) For Horizontal Run
ii) For Vertical Run
Supply & Fabrication of Exhaust Pipe supporting structure made by suitable sizes ( approved by EIC) MS Channel / angle /flat iron frame / structure with necessary support to complte the installation incl painting with two coats of primer and two coats of approved enamel paint. as per direction by EIC
M/S KUNDU CONSTRUCTION
Karmakar electrical Repairing Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .