Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.3 L
EMD Value
₹20,500
Closing Date
12 Aug 2024, 4:00 pmClosed
Executive Engineer ED-II JPDCL
Executive Engineer ED-II JPDCL
Supply, Installation, Testing, Commissioning of 02 No. 25KVA, 11/0.415KV distribution substations along with 11 KV HT Line for Bailing Machine and Shredders at Badyal Brahmna R.S Pura and Village Gandu Chak Panchayat Parlad Pur Phallian Mandal
2024_PDD_253797_1
Enit 31 of 2024 Dated 22-07-2024
Open Tender
Electrical Works
Turn-key
45 days
ED-II JPDCL
As per Enit and SBD
9 documents required · 9 mandatory
₹1,000
Executive Engineer ED-II JPDCL
₹20,500
16 Aug 2024
23 Jul 2024
13 Aug 2024
23 Jul 2024
12 Aug 2024
23 Jul 2024
Amount
Creation of 02 Nos 11/0.433kV, 25KVA , 3-phase Distribution Substation
Supply, Installation & commissioning of 11/0.433kV, 25 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) with LV Cable Box having detachable Aluminium Gland plate. ( As per Latest Ammendment upto date)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of G.I Channel Iron, Cross arms, Angle Iron Braces, Clamps etc. duly fabricated including all necessary G.I Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA, LA with polymer housing, Stn. Type
Providing & fixing of 50 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type along with 12 Nos Al. Thimble of size
Providing & Fixing of LT Distribution Box for 25 kVA DTR with 50 Amp MCCB for incomer & SFU’s for Outgoing Circuits including Busbar arrangements for Phases & Neutral of EC Grade Aluminium, PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 Mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Particulars of works for erection of 0.30 km 11KV line with ACSR Weasel Conductor on 9 Mtrs PCC poles
Supply, Erection, Testing & Commissioning of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, GI Cross arms, GI Angle Iron Braces, GI Clamps etc duly fabricated including all necessary GI Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor.
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm.
Providing & Fixing of 11kV Polymeric composite Disc Insulator with fitting 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Providing & Fixing of Stone Pad (300 mm x 300 mm x 75 mm)
Providing & Fixing of Aluminium Jointing Sleeves
Providing & installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete
Particulars of works for erection & commissioning of 01 Nos Isolation point
Supply, Erection, Testing & Commissioning of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply ,Fabrication & Fixing of GI Channel Iron, GI Cross arms, GI Angle Iron Braces, GI Clamps etc duly fabricated including all necessary GI Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor
Supply, Installation, Testing & Commissioning of 11 KV GO AB Switch, 3-phase, 3-pole, 400 Amp.
Supply, Installation, Testing & Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip(2 nos for PCC poles & ino. For G O Switch/LA)
Providing of Stone Pad 300 mmx300mmx75mm
Supply, Erection, Testing & Commissioning of Prodigy Meter ( Complete)
Supply, Installation, Testing & Commissioning of 3-Phase, 4 Wire Prodigy Meter with all necessary cables of required capacity for making connections including Thimbles & Lugs duly crimped for termination of wires with tapes for meter connections. Technical Specifcation : 3-phase 4-wire,Direct connected,40-200 A,Accuracy Class 1.0, Insulation Protection class II, following standards IS 13779, IEC 62052-11, IEC 62053-21, IEC 62053-23, Dimensions (W x H x D): 365.0 X 283.0 X 221.0 mm (with extended terminal cover) with Enclosure Double-insulated glass-filled polycarbonate along with terminal Thread-through design suitable for current up to 200 A
ASHISH SINGH
M/S RAJ ELECTRICAL CONTRACTOR
M/S DAYAL BUILD TECH
vk construction
VEENA CONSTRUCTION CO.
JASMEET SINGH
M/s ASL POWER SOLUTIONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .