Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 CrAccepted-AOC | ₹23.4 Cr | L1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L2₹32.4 CrRejected-Finance | ₹32.4 Cr | L2 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹35.5 CrRejected-Finance | ₹35.5 Cr | L3 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹37.6 CrRejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹37.6 Cr | L4 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
Tender Value
₹26 Cr
EMD Value
₹15 L
Closing Date
4 Jul 2024, 6:00 pmClosed
Chief Engineer(AF) Nagpur
HQ Chief Engineer(AF) Nagpur, Vayusena Nagar, Nagpur - 440007
PROVISION OF CERTAIN NEW IGLOO SHEDS (PHASE-IV) AT AF STATION AMLA
2024_MES_640401_1
AF_AMLA_801206
Open Tender
Civil Works
750 days
Amla
For MES Enlisted Contractors- Class SS Category a (i) For other Contractor meeting enlistment Criteria of MES for Class SS Category a (i)
8 documents required · 8 mandatory
₹3,000
GE(AF) Amla
₹15 L
Yes
Nagpur
21 Oct 2024
4 Mar 2024
11 Jul 2024
15 May 2024
4 Jul 2024
20 Jun 2024
6 Mar 2024 - 26 Mar 2024
20 Mar 2024
Amount
Blank
Blank
Blank
Blank
Blank
Blank
SCH 'A' PART IX (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule 'A' Part-II.
Supply and fixing hazard division symbol double sided board of size 1500 x 1500 mm by using double legged informatory sign board fixed on single frame and meeting back to back on the square pipe, boards of high intensity Green/blue or in colour as required by using retro-reflective sheeting of AVERY DENNISON made out of 2 mm thick Alco bond/ aluminium sheet conforming to IS 736 to be covered with high intensity grade retro-reflective sheeting (AVERY DENNISON) of Green/Blue or required colour as per user complete all as specified and as directed.
NOTES :- (i) The computerized cut AVERY DENNINSON sheet shall be fixed with suitable adhesive to alco bond/ aluminium sheet painted with epoxy paint to standard make, fixed to structural steel frame work of MS pipe of size 35 x 35mm square pipe with nuts, bolt/rivets ensuring safety against removal of plates. (ii) The lettering shall be computerised cut of high intensity grade white sheeting (AVERY DENNISON) and mechanically fixed on this board of Green/Blue colour or required color. Then these two separate boards shall be fixed back to back on single frame to two vertical posts of 50mm square pipe 2.5 mtr long to be painted in black and white alternative bands of 25cm height with synthetic enamel paint complete in all respect. (iii) This board on single frame shall be embedded in PCC 1:4:8, type D2 of required size including necessary excavation in post hole all as specified and as directed.
Supply and fixing double legged informatory sign board single side of size 1200 x 1200 mm, fixed on single frame and meeting back to back on the square pipe, board of high intensity Green/blue or in colour as required by using retro-reflective sheeting of AVERY DENNISON made out of 2 mm thick Alco bond/ aluminium sheet conforming to IS 736 to be covered with high intensity grade retro-reflective sheeting (AVERY DENNINSON) of Green/Blue or required colour as per user complete all as specified and as directed.
NOTES :- (i) The computerized cut AVERY DENNINSON sheet shall be fixed with suitable adhesive to Alco bond/aluminium sheet painted with epoxy paint to standard make, fixed to structural steel frame work of MS pipe of size 35 x 35mm square pipe with nuts, bolt/rivets ensuring safety against removal of plates. (ii) The lettering shall be computerised cut of high intensity grade white sheeting (AVERY DENNISON) and mechanically fixed on this board of Green/Blue colour or required color. Then these two separate boards fixed back to back on single frame are fixed to two vertical posts of 50mm square pipe 2.0 mtr long to be painted in black and white alternative bands of 25cm height with synthetic enamel paint complete in all respect. (iii) This board on single frame shall be embedded in PCC 1:4:8, type D2 of required size including necessary excavation in post hole all as specified and as directed.
INTERNAL ELECTRIFICATION
Material and labour for sub main wiring with 2 runs of 2.5 Sqmm as main cable and one run of 2.5 sqmm as earth continuity conductor on wall and surface wiring on ceiling / roof with necessary fixing arrangements using approved colour coding as per IS with single core PVC insulated unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade, IS-694 marked, drawn through ISI Marked (IS 9537 Part II) ERW stove enamelled rigid steel conduit suitable for wiring, not less than 20mm dia with all MS conduit accessories/ fittings such as bends, tee, elbow etc., and making good the disturbed surface complete all as specified and as directed.
Notes : (i) Rates of flame proof junction boxes, flame proof unions and couplings, rotary switch shall be measured and paid separately. (ii) One rotary switch shall control 2 to 3 Nos FP Points fitting. (iii) 3 runs of 2.5 sqmm cable and 1 run of conduit shall be measured as 1 unit . (iv) Rates of flame proof bends and elbows, couplers, bell mouth reducer etc. shall be deemed to be included in the rate quoted.
Supply and fix flame proof and weather proof switch rotary type with termination box in LM6, 16 A, single pole, 250 V suitable for hazardous locations of Zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete all as specified and as directed.
Supply and fixing surface mounted flame proof junction box 3 to 4 way 20 mm minimum all as per relevant IS for flame proof sub main wiring complete all as specified and as directed.
Supply and fixing surface mounted flame proof union (male, female type) dia 20 mm minimum all as per relevant IS for flame proof sub main wiring complete all as specified and as directed.
Supply and fixing flame proof coupling dia 20 mm all as per relevant IS for the flame proof sub main wiring complete all as specified and as directed.
Supply and fixing CMRI certified LED flame proof well glass luminaries 60 Watt with LM6 aluminium alloy lamp housing heat resistant and toughened glass, cover hinges cover with neoprene gasket, painted MS bar guard, epoxy finish provided with built in control gear box complete with all accessories internally prewired & eye bolt for suspension, IP 65 protection and including fixing light fitting on wall/roof and making all electrical connection complete all as specified and as directed.
Supply and fixing LED 60 W flame proof bulk head light fitting properly earthed suitable for hazardous locations of Zone 1 & 2 Ex 'd' with relevant IS & IP65 protection complete with all mounting attachments complete all as specified and as directed.
Material and labour for earthing with galvanized iron earth plate of size 600 mmx600mmx6mm thick buried directly in ground not less than 2.25 mtr below normal ground level, earth plate packed on all side with charcoal mixed with salt to a thickness of 150 mm connected by GI wire 4 mm dia at two points soldered and riveted to earth plate, GI earth wire protected by using 20 mm bore light grade GI pipe, watering pipe GI 20 mm dia medium grade 2.5 mtr long with funnel, wire mesh etc. necessary earth/brick work and PCC work, disposal of surplus soil to a distance not less than 50 metre, chamber of PCC (1:4:8) type D2 using 40 mm graded stone aggregate, coping in PCC (1:3:6) type C1 using 20 mm graded stone aggregate,
RCC pit cover 50 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate, reinforced with 8 mm MS bar at 80 mm C/C both way, flame funnel wire mesh, testing on completion all as specified and as shown in electrical plate No 3 of MES SSR Part-1 2009 complete all specified and as directed. Note:- Quantity of GI earth wire & protection pipe beyond 7.5mtrs length shall be measured and paid separately.
Supply and fixing weather proof distribution board approved by CMRI Dhanbad of cast aluminium alloy LM6 MCB type SPN 8 way with and including 32 Amps SPN MCB as incoming - 01 No with rotary switch and MCB SP 'C' series 10 KA 6-32 Amps - 6 Nos with rotary switch as outgoings complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
Material and labour for Cutting/ Demolition of PCC/Hard Standing Plinth Protection/WBM Road not exceeding 30 cm in width and not exceeding 45 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e. bitumen/PCC 1:3:6 type C1 complete all as specified and as directed.
Supply, installing, testing and commissioning of LT feeder pillar box, weather andf vermin proof, factory fabricated, cubical type made out of CRCA sheet 3 mm thick with mounting on frame of angle iron 50 x 50 x 6 mm, fixed on ground but not less than 30 cm high from ground level, suitable for 415 Volt, 3 phase, 4 wire system with front openable each compartment with PVC star screwing hinged arrangement including locking arrangement with sliiding bolts, internal wiring complete with suitable size copper conductor cable for metering system and CTs complete all as specified and as directed and comprising of following equipments/fitments complete :-
(i) MCB, 4 Pole, 40 Amps - 01 No (ii) Isolator SPN 32 Amps - 4 Nos (c) Digital type VAF complete - 1 No (d) Indicator lamp RYB - 1 set (e) Aluminium bus bars 200 Amps rating, 3 Nos for phases and one No for neutral of half capacity - 1 set (f) PCC foundation in PCC 1:2:4 type B1 including earthwork, rendering etc. complete all as specified - 1 job. NOTE :- (i) LT feeder pillar box shall be CPRI approved. (ii) All MCBs & Isolator shall be fitted in vertical position.
Material and labour for earthing complete with GI mild steel earth plate electrode 600mm X 600mm X 6 mm thick, burried directly in ground veritcally (Earth pit not less than 2.25 metre deep below ground level) with top edge of the earth plate not less than 1.5 metres below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and earth plate connected to GI strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of steel and riveted to earth plate at one end and connected to metallic bodies of equipment etc. at other end, earth strip encased in and
including 40mm bore GI light grade pipe with all fitting from top of electrode to the body of equipment fixed with and including 25 x 4mm flat iron clamps, bolts, nuts and washer and also including GI pipe 20 mm light grade for watering from bottom of earth pit to top of electrode including GI funnel with wire mesh all as shown in electrical plate No. 3 including PCC pit (1:3:6) type C1 in cement concrete 40mm thick precast RCC cover in (1:2:4) type B1 reinforced with 8mm dia TMT bars @ 75 c/c both ways with 01 No lifting handle of 12mm dia MS plain bar, etc. complete all as specified and as directed. NOTES : (i) Quantity of GI strip/ protection pipe beyond 7.5mtrs length shall be measured and paid separately. (ii) 2 Nos of earthing under this item shall be for External Electrification and 32 Nos of earthing shall be for Lightening Protection.
ROAD/PATH/CULVERT/FIREBREAK
Labour only including all necessary equipments for finishing 150 mm thick paving tremic concrete using vaccum dewatering method complete all as specified and as directed.
LIGHTNING PROTECTION
Supply and fixing ready made type PVC junction box IP65 of size 200 mm x 160 mm x 98 mm having shutter and lefting knob with provision of earthing strip entry glands and fixing the box on wall/poles with suitable size of clamps, nuts, bolts and washers etc. complete all as specified and as directed.
Supply, erection in true vertical position and fixing of steel tubular LT poles, swaged, welded complete with Cl base plate 6mm thick of size 300mm X 300 mm, finial taper plug pole cap, bolt and nuts and screw as per IS-2713 (Pt- II) made out of ERW MS Tubing with including drilling of hole of required size & Nos for fixing cross arms & 02 Nos hole on bottom and top of pole for insertion of cable including painting with two coat of aluminum paint over one coat of primer for exposed surface and two coat of bituminous paint for embedded portion in concrete, painting three blue bands at lower portion of pole 300 mm height at 300 mm spacing. painting pole No with black paint at suitable height complete of type 410 SP- 73 (14.5 mtr long) all as specified and as directed.
EXTERNAL WATER SUPPLY
Material and labour for valve chamber 900 x 900 x 900 mm (internal) with fly ash brick masonry 230 mm thick in cement mortar 1:6, PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) foundation 75 mm thick finished fair and even, PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar 1:4 plaster on exposed surfaces of brick wall (both internal and external), MS cover 3 mm thick including MS angle iron 40x40x6 mm size frame fixed to PCC coping with same size of angle iron hold fast and with necessary handle and locking arrangement, metal surfaces duly painted with black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surface with 3 coats of white wash including necessary excavation and earthwork complete all as specified and as directed.
Total amount of Schedule 'A' Part XIV carried over to General Summary
Blank
Blank
GENERAL SUMMARY
Lumpsum price worked out by the contractor for “BUILDINGS & STRUCTURES” as listed in Schedule ‘A' Part I representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part I on Srl Page No. 33(R)
Lumpsum price worked out by the contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK (FOR SCHEDULES OTHER THAN SCHEDULE 'A' PART-I)” as listed in Schedule ‘A' Part II representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part II on Srl Page No. 35(R)
Lumpsum price worked out by the contractor for “ROAD/ PATH/ CULVERT/ FIRE BREAK” as listed in Schedule ‘A' Part III representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part III on Srl Page No. 41(R)
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A' Part IV representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IV on Srl Page No. 43(R)
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A' Part V representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part V on Srl Page No. 45(R)
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A' Part VI above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part VI on Srl Page No. 48
Lumpsum price worked out by the contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A' Part VII representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VII on Srl Page No. 54(R)
Total amount of SCHEDULE 'A' PART VIII (MISC B/R & E/M ITEMS) brought forwarded from Serial Page No. 69(R)
PRAGMATIC INFRASTRUCTURE LIMITED (BID ID -3042426)
M/s Gujarat Construction Company (BID ID -3041945)
Phoenix Infra (BID ID -3041790)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid