20 Aug 2021, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Special repairs to certain buildings of KV School at Old Cantt Allahabad.
2021_MES_445682_2
8469/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹48,000
Yes
6 Sept 2021
29 Jul 2021
23 Aug 2021
29 Jul 2021
20 Aug 2021
13 Aug 2021
29 Jul 2021 - 5 Aug 2021
Amount
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed..
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5sq.m not exceeding 4.0sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and directed.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, including ridges, complete all as specified and directed.
Provision of false ceiling, consisting of E-Board of make : Everest or techno-commercially equivalent in Armstrong / Sanitgobain, design "lake and hill" of size 605mm x 605mm x 4mm thick, white prelaminated set, embossed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section (white powder coated); the framework shall comprises of main runner made of 0.33mm thick GS sheet and of size 24mm x 32mm x 300mm and spaced at 1200mm (maximum) centre-to-centre, securely fixed to structural soffits with hangers of 4.00mm dia GI wire, to be fixed with approved rawl plugs, adjusters and screws; flush fitting of 1200mm long cross tee (double section) to be interlocked between main runners at 600mm centre-to-centre to form 1200mm x 1600mnm modules, cross tee shall be longer than 600mm, to be supported independently. 600mm x 600mm doubles to be formed by fittings 600mm long cross tee centrally between 1200mm cross tee; perimeter wall angle shall be made out of 0.45mm thick GS sheet of size 19mm x 19mm and 300mm long of white colour, all as per manufacturers specifications, complete all as specified and directed.
Mild steel works (miscellaneous) as in framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165, complete all as speicirfed and directed.
Steel windows, factory made, with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
Steel windows, factory made, with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
Steel ventilator, factory made, with top hung shutter including box type hinges, steel peg stay complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of walls, finishing the surface even and smooth without using exta cement but mixed with and including provision of integral water proofing compound as per manufacturers instructions, complete all as specified and directed. NOTE:- The quantity of water proofing compound shall be measured and paid separately under respective items of this Schedule.
Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of walls, finishing the surface even and fair, complete all as specified and directed.
Supply only integral water proofing compound, complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
Sheet glass, 3mm thick, ordinary quality and glazing in squares not exceeding 0.5 sq. m in each pane with oil putty, complete all as specified and directed.
Flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
Rolled mild steel sections conforming to Fe-410 W (Grade E-250) quality 'A' as in framing for cladding, glazing and including door frames / chowkats, cooler stand etc., fixed with angle cleats and connecting plates, etc, complete all as speicirfed and directed.
Mild steel sliding door bolts 250 mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section 200mm long complete all as specified and directed.
Aluminium handles, cast type, anodised, 150mm long, complete all as specified and directed.
100mm long butt hinges, extrucded aluminium alloy with brass/bronze hinge pin, anodised type B-21, bright polished type B-11, complete all as specified and directed.
Preparation of wood or wood based new surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Preparation of new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of new decorated surfaces of AC sheet as in roof of any description, over 10cm width or girth not otherwise described and applying two coat of weather coat antifungal exterior emulsion paint over a coat of primer including washing of floors, cleaning of glass/ joinery/ electric fittings/ switches etc. complete all as specified and directed.
Preparation of new plastered surfaces of walls over 10cm width or girth not otherwirse described and applying two coat of acrylic emulsion paint over a coat of alkali resistant primer over two coats of internal grade wall care putty (the total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coat of acrylic emulsion paint over a coat of alkali resistant primer over two coats of internal grade wall care putty (the total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed.
Preparation of newly plastered surfaces of walls of any description over 10cm width or girth not otherwise described and applying two coat of cement base paint over two coats of external grade wall care putty (the total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coat of cement base paint over two coats of external grade wall care putty (the total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed.
Preparation of old decorated surfaces of AC sheet as in roof of any description over 10cm width or girth not otherwise described (including brooming down or scraping with steel wire brushes, washing down with water and removal of rubbish from roof surfaces) and applying two coat of weather-proof antifungal exterior emulsion paint over a coat of primer, including washing of floors, cleaning of glass / joinery / electrical fittings / switches etc., of drops / splashes of paint, complete all as specified and directed.
Abestos cement, corrugated or semi-corrugated sheets, 6mm thick, in roofs, walls etc., fixed with L-type or J-type or cranked hook bolts, complete all as specified and directed.
Abestos cement, corrugated or semi-corrugated sheets (Except sheets), 6mm thick, in roofs, walls etc., fixed with L-type or J-type or cranked hook bolts, complete all as specified and directed. NOTE:- Quantities of AC sheets retrieved from dismantling of AC sheets vide Sl. No. 4.00 here-in-before shall be used.
Abestos cement, corrugated or semi-corrugated sheets, 6mm thick, two piece adjustable plain wing ridge, fixed with L-type or J-type or cranked hook bolts, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Taking down switches, distribution boards and old cut-outs etc., of any type and carefully along with the existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Taking down carefully sub-main wiring of any type and any numbers including earthwire surface type / concealed type and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.00mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FR copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light point controlled by one 5 Amp one-way switch, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 36.00 here-in-before but for 5-pin 5Amp socket outlet point on independent board
All as per Sl. Item No. 36.00 here-in-before but for one 5-pin socket oiutlet 5 Amp on same board alongwith other switches
Point wiring complete with 2.50 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.00mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for housing switches, sockets, regulators etc., including 2.50 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 6-pin, 15/16 Amp socket outlet, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
Switch piano, flush type single pole, one-way 5 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 5A, flush type, ISI marked, complete all as specified and directed.
Switch piano, flush type single pole, one-way 15/16 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Socket outlet 2 in 1, 6 pin, 15/16 Amp, flush type, ISI marked, complete all as specified and directed.
Lamp holder, PVC polycarbonate body with back plate suitable for batten fittings, complete all as specified and directed.
Ceiling rose three terminal PVC / polycarbonate insulated body, surface bakelite type AC 50 Hz 230V, complete all as specified and directed.
Ceiling fan 230Volt, 50Hz, single phase AC supply, 1400mm sweep with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to fan including writing MES number on fan motor using synthetic enamel paint of approved tint, complete all as specified and directed. MAKE:- Havells / Bajaj / Crompton Greaves
Stepped (rotary) type electronic fan regulator (suitable for 1200mm / 1400mm sweep ceiling fan) flush type duly fixed on the existing phenolic laminated sheet etc. as required, 240V, humming free, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
MCB DB, SPN, double door, epoxy powder coated, factory made 8-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCCB DB wall mounted vertical type TPN 4 way with and including provision of MCCB TPN 160Amp 25KA rupturing capacity as incomer and SP 6-32 Amp MCBs - 06 Nos, 'B' series, 10KA breaking capacity as outgoing, double door with 200Amp rated bus bars for main distribution DB and including provision of thimble copper lugs, blanking paltes etc complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB SPN 6 - 32 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, complete all as specified and directed.
MCB SP 6 - 32 Amp, 240 Volt, 'B' curve, 10KA breaking capacity, complete all as specified and directed.
LED bulk head light fitting, 10W, 600lumen, enclosed in polycarbonate body, weather proof, fixture with co-extruded polycarbonate body, environmental friendly, energy efficient, complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. ENDURA Model No. WT202W LED65 CWPSUS1PC of Philips or techno-commercially equivalent model in Havells / CG
Recessed mounted decorative LED light fitting, of size 600mm x 600mm, 36W, 2800-6500K lumen efficiency, high brightness including suitable driver polycarbonate body, environment friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. ARIION III, Model No. LCTLSN-36-CDL of Crompton or FULL GLOW Cat No. RC 380BLED355-6500G4L60W60PSU OD of Philips or techno-commercially equivalent model in Bajaj / Havells
LED wall mounted tube light fitting, 1x18W, LED 6000K, decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. LHEXBHP7IN1W018 of Havells or techno-commercially equivalent model in Philips / CG
Security LED light fitting 25Watt, IP-65 protection pressure die-cast aluminium body, heat resistant glass, including driver and making necessary electric connection with 2.5sq.mm twin core copper wire 1.50metre long complete fixed to and including provision of GI pipe light grade bracket 1.20metre long and bent to shape required and fixed with suitable FI 40mm x 6mm clamp two Nos with nuts, bolts and washers as required, complete all as specified and directed. MAKE:- Cat No. BRLEP25W LED WH of Bajaj or Cat No. ASTRAL LSTS 25CDL of Philips or techno-commercially equivalent model in CG
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 25mm dia including conduit accessories and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit and conduit accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) If earth resistance is not found satisfactory, till satisfactory test result comes, the same shall be redone by the contractor without any extra cost to department.
Shivam Constructions
Hi-Tech Constructions
M/S A P CONSTRUCTION
Shivagya Engineering
M/S Shiv Ballabh Mishra
M/S Rajani Singh
His And Her Enterprises
chauhan construction
M/S SS Tarders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .