Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹51.0 LAdmitted-Finance | +2.50% | ₹51.0 L | L1 | Admitted-Finance |
| 2 | L2₹52.0 L+₹99,581 (1.95%)Admitted-Finance | +4.50% | ₹52.0 L+₹99,581 (1.95%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical technical not doc completed |
Tender Value
₹49.8 L
EMD Value
₹99,600
Closing Date
11 Aug 2026, 2:00 pmClosed
EO
Nagar Palika Mandawari
To get the work of 9 meter octagonal pole with street light done in the municipal area. 3
2026_DLB_579141_1
NPM/20226/71-3
Open Tender
Electrical and Maintenance Works
Percentage
90 days
Mandawari
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
MD RISL
₹99,600
Yes
18 Aug 2026
29 Jul 2026
12 Aug 2026
29 Jul 2026
11 Aug 2026
29 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 2 | 16.0 Sq. mm 4 core. | 2,000 | Mtr | 238 | ₹4,76,000 |
| 3 | 25.0 Sq. mm 3 core | 500 | Mtr | 250 | ₹1,25,000 |
| 4 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed
Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of
1.1 KV with electrolytic grade Copper made of copper rods
confirming to IS 613-1964, of purity >99.7 %, round / flat strip
armouring, Inner / outer sheath confirming to IS:5831 in existing
RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench /
Cable tray(with cable tie) including testing etc. as required of
following size. OEM must have it's own in house NABL accrediated
Laboratory for testing procedure as per IS:10810 For additional
technical parameters of product / work refer Annexure 'A' attached
with this BSR | - | - | - | - |
| 5 | 6.0 Sq. mm 3 core | 900 | Mtr | 357 | ₹3,21,300 |
| 6 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 40 | Nos | 15,523 | ₹6,20,920 |
| 7 | Supply & Laying following size earth wire in horizontal or vertical run
in ground/surface/recess including riveting, soldering, saddles,
making connection with GI/Cu purity purity >95% thimble etc. as
required. All as per pre approved by Engineer in-charge. For
additional technical parameters of products/ work , refer Annexure
"A" attached with this BSR . | - | - | - | - |
| 8 | 6 SWG tinned copper Wire | 1,200 | Mtr | 238 | ₹2,85,600 |
| 9 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | - | - | - |
| 10 | 9 Mtr Pole | 55 | Each | 19,456 | ₹10,70,080 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 8.22 MB
BOQ_1029127.xls
BOQ • 0.31 MB
corrigendumonline.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .