Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC | ₹2.2 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹2.3 Cr+₹19.0 L (8.82%)Rejected-Finance | ₹2.3 Cr+₹19.0 L (8.82%) | L2 | Rejected-Finance Higher bidder |
| 3 | L3₹2.4 Cr+₹19.3 L (8.96%)Rejected-Finance | ₹2.4 Cr+₹19.3 L (8.96%) | L3 | Rejected-Finance Higher bidder |
| 4 | L4₹2.4 Cr+₹27.5 L (12.8%)Rejected-Finance BU 02 SFS FLATS OUTER RING ROAD PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹2.4 Cr+₹27.5 L (12.8%) | L4 | Rejected-Finance Higher bidder |
| 5 | L5₹2.4 Cr+₹27.9 L (12.9%)Rejected-Finance | ₹2.4 Cr+₹27.9 L (12.9%) | L5 | Rejected-Finance Higher bidder |
Tender Value
₹2.6 Cr
EMD Value
₹3.3 L
Closing Date
12 Nov 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPLACEMENT OF BER CENTRALISED AIR CONDITIONING PLANTS INCLUDING COMPREHENSIVE MAITENANCE AND OUTSOURCING FOR MANNING AND OPERATION OF AIR CONDITIONING PLANTS OF PRODUCTION BLOCK AT NAY GOA UNDER GE NW VASCO
2021_MES_448848_3
85410/E8
Open Tender
Civil Works
Item Rate
365 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹2,000
Yes
GE NW VASCO
₹3.3 L
Yes
27 Dec 2021
21 Oct 2021
15 Nov 2021
21 Oct 2021
12 Nov 2021
28 Oct 2021
Amount
(PART - I) Notes:- The unit-rate quoted for Air conditioning work shall deemed to be included for taking down of existing false ceiling and any other usable material carefully and to preserve it in safe conditions for refixing after completion of work complete all as specified and as directed.
Supplying, installing, testing & commissioning of water cooled scroll chillers,77 TR Minimum Actual capacity (2 Nos working + 1 no standby) with multi compressors, comprising of semi -Hrmatic / Hrmatic/open type compressors, DX-Evaporator, shell and condenser suitable expansion device for operation on R-407/410a refrigerants and of actual capacity as mentioned & as per specification . Frame work for mounting the above condenser, chiller, compressor and motor with base plate complete with anti vibration pads/springs. Initial/first charge of refrigerant gas & compressor oil. The chiller operation parameters shall be Chilled water in 54 ºF(12.2º C) Chilled water out 44 ºF(6.7ºC) Max operating pressure 150 psig(water side/condenser side) Condenser water IN 90.0 ºF (32.2 ºC) Condenser water OUT 97.5 ºF (36.4 ºC) Chiller fouling factor 0.0005 ft.hr.deg F/BTU (0.0001 mtr.hr.deg C/Kcal) Condenser fouling factor 0.001 ft.hr.deg F/BTU (0.0002 mtr.hr.deg C/Kcal) Chilling machine COP (at AHRI conditions ) shall be min 4.4 and IPLV of min 5.2 & all performance requirements at ARI 550/590-1998 test condition Relative humidity range = 50(+/-)10% complete all as specified and as directed
Notes:- (i) The unit shall be suitable for three phase 415 volt +/- 10%,50 HZ AC electric supply with inbuilt microprocessor based control panel. (ii) Initial/first charge of refrigerant gas and compressor oil shall be deemed to be included in the quoted rate. (iII) Necessary civil work i.e foundation for placement of chiller etc shall deemed to be included in the quoted rate
Supply, installation, testing and commissioning of PN16 rated Centrifugal split coupled type end suction single stage chilled water pump with CI Casing, Bronze Impeller, SS shaft, Base Frame, Coupling, Coupling Guard, Mechanical Seal(to be easily replaceable without disturbing the pump and motor shaft), each pump capable of delivering the specified flow rate comprising the following and complete as per specifications. i) 1 No. -End suction split coupled type single stage pump with bronze impeller, S.S Shaft, CI body and mechanical seal. ii) 1 No. Suitable HP, TEFC squirrel cage induction motor (IE-2) with class 'F' insulation, suitable RPM synchronous speed, operating on 415 Volts + 10 %, 3 phase, 50 Hz A.C. supply. Water flow rate : 186.5 USGPM (706 LPM Approx) Head : 85 ft. Motor HP : 7.5 HP(suggested) or as per OEM standard Efficiency : 75 % or above Pumps as mentioned above (2W+1S) complete all as specified and as directed Notes:- (i) Necessary civil work i.e foundation for placement of pump etc shall deemed to be included in the quoted rate (ii) Contractor must provide lot-mounting frame work along with necessary vibration isolation arrangement, if required.
Supply, installation, testing and commissioning of PN16 rated Centrifugal split coupled type end suction single stage condenser water pump with CI Casing, Bronze Impeller, SS shaft, Base Frame, Coupling, Coupling Guard, Mechanical Seal (to be easily replaceable without disturbing the pump and motor shaft), each pump capable of delivering the specified flow rate comprising the following and complete as per specifications. i) 1 No. -End suction split coupled type single stage pump with bronze impellar, S.S Shaft, CI body and mechanical seal. ii) 1 No. Suitable HP, TEFC squirrel cage induction motor (IE-2) with class 'F' insulation, suitable RPM synchronous speed, operating on 415 Volts + 10 %, 3 phase, 50 Hz A.C. supply. Water flow rate : 317 USGPM (1200 LPM Approx) Head : 90 ft. Motor HP : 12.5 HP(suggested) or as per OEM standard Pump Efficiency(Min) : 75% or above Pumps as mentioned above (2W + 1S ) complete all as specified and as directed Notes:- (i) Necessary civil work i.e foundation for placement of pump etc shall deemed to be included in the quoted rate (ii) Contractor must provide lot-mounting frame work along with necessary vibration isolation arrangement, if required.
Supply, installation, commissioning and testing of induced draft top discharge counterflow type FRP Cooling Tower (Rectangular/Round bottle shape) with FRP body and base, water spray headers, cooling tower fills, fan with motor, supporting base frames, as per manufacturer's standard instructions, complete as per specifications and as required. Water Leaving Temperature : 90.0 Deg F (32.2 Deg C) Water Entering Temperature : 97.5 Deg F (36.4 Deg C) Ambient Monsoon Wet Bulb Temperature for Vasco Da Gama : 84.0 Deg F (28.7 Deg C) Heat Rejection Capacity : 160 TR Water Flow Rate : 308 USGPM Cooling Tower as above (2 W) complete all as specified and as directed Note:- (i) Necessary civil work i.e foundation for placement of cooling tower etc shall deemed to be included in the quoted rate
The closed expansion tank will be of M.S. construction with interchangeable EPDM-BUTYL rubber membrane. The expansion tank shall be complete with safety relief valve and pressure gauge. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations. For chilled water application, it will be insulated with 50 mm thick insulation to the specifications and cladded with 26G-aluminum cladding. The expansion tank shall be supplied along with pressurization unit. The pressurization unit shall consist of two nos.(1 working+1 stand-by) high pressure pumps of suitable pressure rating mounted on M.S. frame, complete with interconnecting piping, isolation valves, NRV, Y-strainer, Pressure gauge, pressure transmitter, auto-logic panel(IP 55) with dry-run protection, electrical MCB and interconnecting wiring. The unit shall be housed in powder-painted canopy suitable for external installation, if required. 500 Liters approx. capacity tank (on chilled water system main header) complete all as specified and as directed
Supply installation testing and commissioning of Deaerator-dirt separator. Flanged connections, complete with Brass drain valve 1” F (from DN 50 to DN 150), 2” F (from DN 200 to DN 300) PN 16. complete with a set of concentric metal mesh surfaces to create the swirling motion required to facilitate the release of micro-bubbles and dirt to the surfaces. Epoxy resin coated steel body. Brass automatic air vent valve body. Stainless steel internal element. PP float. Brass float guide and stem. Stainless steel float lever and spring. EPDM hydraulic seals. Medium water and non-hazardous glycol solutions excluded from the guidelines of EC directive 67/548; maximum percentage of glycol 50%. Maximum working pressure 10 bar. Working temperature range 0–110°C. Particle separation rating down to 5µ. Working temperature range 0–100°C. Floor brackets as per site requirement.Connection size 125 mm (for chilled water main line) complete all as specified and as directed
Providing and placing on terrace (of plant room) polyethylene water storage tank of capacity 2000 ltrs , IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and as directed Note: The arrangement for the makeup soft water shall be made by the client to fulfil the makeup water requirement.
Supply , install , commissioning and testing of Double Skin Floor Mounted Air Handling Unit with 6 Rows Deep Coil of nominal capacity having panel thickness size 25 +/- 2 mm with outer as 0.6 mm and inner sheet of 0.6 mm GI as shown complete all as specified and as directed
(a) 10000CFM / 31.0TR, 60mmwg SP, Fan motor of required HP (For Ground Floor)
(b) 20000CFM / 59.0TR, 60mmwg SP, Fan motor of required HP (For First Floor)
(c) 22000CFM / 67.0TR, 60mmwg SP, Fan motor of required HP (For First Floor)
Supply, Installation,testing & Commissioning of duct mounted Electric finned strip Heater for monsoon reheating with thermostatic controller including power & control wiring. Unit shall be of corrosion resistant steel frame with control box. Unit shall start only after air supply is active and automatically cutoff as package unit stop. Actual kW shall be consider by as per Manufacturer standard, complete as required. Panel Details: Fabricated out of 16G CRC Sheet duly powder coated having following controls. Panel is attached with heater battery & Internally wired with heater complete all as specified and as directed Front Panel Controllers. 1. Fan on/off heater rocker switch. 2. Power on indication. 3. Heater on indication. 4. Manual/auto rocker switch 5. Fan run indication. 6. Fan failure indication 7. Door inter lock system
Connectioning 1. Electric heater battery. 2. Supply fan. 3. Temperature sensor via duct or room thermostat. 4. Airflow switch(normally open) 5. High temperature cut-out (an integral part of a heater battery) High Temperature A high temperature cut-out is provided to protect the system and element bank against temperatures in excess of the design conditions and wired in series to ensure that the heater is shut down until the fault is rectified. Manual Reset This will manually be reset when the fault has been rectified.
(i) Heating 16.0kW Approx (1 nos. 16.0kW capacity each)
(ii) Heating 42.0kW Approx (3 nos. 14.0kW capacity each)
Supply, installation, testing and commissioning of latest generation digital display type cooling thermostat/humidistat with controller for cooling application suitable for two pipe system for various air handling Units. The thermostat/humidistat shall have provision of setting of space temperature & humidity and display of the same. The quoted price of thermostat/humidistat shall include the cost of 20mm MS conduits, control cabling, MS Box etc. as required. The cost quoted shall be excluding the control valves. It shall include all accessories ,mountings, wiring between thermostat/humidistat & unit, terminations etc complete all as specified and as directed
Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes as shown as per specification and as required complete all as specified and as directed
(a) 150 mm dia
(b) 125 mm dia
(c) 100 mm dia
(d) 80 mm dia
(e) 65 mm dia
(f) 50 mm dia
(g) 40 mm dia Note:- The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes up to 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
M & L for Insulation of M S Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes as shown as per specifications and as required complete all as specified and as directed
(a) 65 mm dia. CHW Pipe
M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminous compound and GI cladding with 26 gauge GI sheet complete of sizes as shown. as per specifications and as required complete all as specified and as directed
(a) 125 mm dia
(b) 100 mm dia
(c) 80 mm dia
Supplying, fixing, testing and commissioning of butterfly Valve(Manual) with C I body SS Disc, Nitrile rubber Seal & O- Ring PN 1.6 pressure rating for chilled water circulation, in the chilled/hot water plumbing duly insulated to the same specifications as the connected piping and adequately complete all as specified and as directed
(a) 125 mm dia
(b) 100 mm dia
(c) 80 mm dia
(d) 65 mm dia
Supplying, fixing, testing and commissioning of Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water circulation, in the chilled/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications complete all as specified and as directed
(a) 125 mm dia
(b) 100 mm dia
(c) 80 mm dia
(d) 65 mm dia
Supplying, fixing, testing and commissioning of NON - RETURN VALVE 100 mm dia, with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled water circulation, in the chilled/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications complete all as specified and as directed
Supplying, fixing, testing and commissioning of Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled water circulation, in the chilled/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications complete all as specified and as directed
(a) 100 mm dia
(b) 80 mm dia
(c) 65 mm dia
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications & as required. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for condenser water circulation complete all as specified and as directed
(a) 150 mm dia
(b) 125 mm dia
(c) 100 mm dia
(d) 50 mm dia
Supplying, fixing, testing and commissioning of Balancing Valve 125 mm Dia with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch & PN 16 pressure rating for condenser water circulation as specified for condenser water circulation as per specifications complete all as specified and as directed
Supplying, fixing, testing and commissioning of NON - RETURN VALVE 125 mm dia with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for condenser water circulation as specified for condenser water circulation as per specifications complete all as specified and as directed
Supplying, fixing, testing and commissioning of Y - Strainer 125 mm dia of Ductile CI Body flanged ends with stainless steel strainer for condenser water circulation as specified for condenser water circulation as per specifications complete all as specified and as directed
Supply, installation, testing and commissioning of Three Way Control Valve in a single body equipped with electronic modulating actuator working on 0-10 V DC, 4- 20 mA electric signal. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications of following sizes. The valve shall be complete with digital type modulating thermostat (with NTC sensors) which will have provision of setting room temperature. The valve system shall be complete with necessary control cabling between control transformer, valve and standalone thermostat.The valve shall be suitable for the following pipe sizes complete all as specified and as directed
(a) 100 mm dia
(b) 80 mm dia
(c) 65 mm dia
Providing and fixing in position the following Ball Valves 40 mm dia for makeup line as per specifications complete all as specified and as directed Note :Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting & gland of superior quality of preferably PN 1.6 rating.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required complete all as specified and as directed
Providing & Fixing in position the mercury in glass with industrial type thermometers complete all as specified and as directed
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminators suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications (PN 1.6 rating) complete all as specified and as directed
(a) 100 mm dia
(b) 125 mm dia
Providing and fixing Auto air vents (Brass MOC) of 25 mm dia complete all as specified and as directed
Supplying, installation, testing and commissioning of Pot strainer. Pot Strainers body shall be fabricated out of MS plate of size 8 mm thick IS 226. Thickness of sheet shall be as per size of the strainer chamfered pipes with flanges shall be provided at inlet /outlet connections of the strainer. A powerful magnet shall be provided in the body to arrest MS particles. Filter element of Pot Strainer shall be of non magnetic 18 gauge SS sheet properly reinforced to avoid damage of the element. A set of MS flanges with tongue and groove arrangement and neoprene rubber gasket shall be provided on the top cover and Pot Strainer flange with sufficient bolts and nuts to make the joint water light. The Pot strainer body shall be properly de-rusted and epoxy coated from inside and outside complete all as specified and as directed
(a) Connection Size 150 mm dia (for condenser water line)
(b) Connection Size 125 mm dia (for chilled water line)
Supply , Installation, Testing & Commissioning of FLOW SWITCH of brass construction suitable for below mentioned pipe dia, as per specification & requirement complete all as specified and as directed
(a) 150 mm dia
(b) 125 mm dia
Providing and fixing in position 40 mm dia GI pipe medium class cut to required length and installed with screw joints including the necessary fittings (bends, tees, unions, sockets etc) duly insulated with 6 mm thick nitrile rubber pre formed pipe section as per specifications complete all as specified and as directed
Supply, installation, testing, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required complete all as specified and as directed
(a) Thickness 0.63 mm sheet (24 Gauge)
(b) Thickness 0.80 mm sheet (22 Gauge)
(c) Thickness 1.00 mm sheet (20 Gauge)
(d) Thickness 1.25 mm sheet (18 Gauge) Note- 1) All hanging and support of ducts shall be with Hangers & Supports complete with end fixing in accordance with the approved shop drawings and as required by the specifications. 2) All the plenums shall be constructed in 18G sheet
Supply, installation, testing and commissioning of GI volume control duct damper of 1.2 mm thick sheet complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications & as required complete all as specified and as directed
Supply, fabrication, installation and testing of non-porous flexible connections constructed of fire resistance flexible, double canvas connection with resistoflex material as per the approved shop drawings complete all as specified and as directed
Supplying & fixing of powder coated extruded aluminium Supply/Return Air Grills with aluminium volume control dampers as per specifications complete all as specified and as directed
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications complete all as specified and as directed
(a) Fire damper(150 mm deep)
(b) Control Panel with actuator(10Nm Torque) & Wiring
Supplying, installing, testing and commissioning of Fresh Air powder coated Anodized extruded aluminium construction fresh air louvers (50 mm deep) (Fresh air louver with VCD , bird screen & rattle-free) complete as per specification complete all as specified and as directed
Supplying and fixing of following thickness factory laminated glass cloth overclosed cell flexible elastomeric foam insulation with fire performance rating of 25/50 as per ASTM E 84 after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. The insulation material shall meet ASHRAE 90.1-2010, ASHRAE Standard 189.1, NFPA 90A & NFPA 90B Standards. The insulation material shall have Microban®* an anti-microbial product complete all as specified and as directed
(a) 13 mm thick (Return air ducts)
(b) 19 mm thick (Supply air ducts)
Supply, installation testing and commissioning of duct acoustic insulation inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test or 10,000 fpm air velocity as per ASTM C 1071-05 to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete all as specified and as directed
(a) 10 mm Thick Insulation
(b) 25 mm thick Insulation
Supplying ,laying , fixing & testing of following sizes of XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 volts grade complete as required and as directed
(a) 3 ½ C - 70 sq mm
(b) 4C- 25 sq mm
(c) 4C- 10 sq mm
(d) 4C- 6 sq mm
(e) 3.5 C- 120 sq mm
(f) 3.5 C- 50 sq mm
(g) 2 C- 2.5 sq mm
(h) 5 C- 1.5 sq mm
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required complete all as specified and as directed
(a) 150 mm width X 50 mm depth X 1.6 mm thickness
(b) 200 mm width X 50 mm depth X 1.6 mm thickness
M&L for earthing complete with galvanised iron earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip Size 20 x 3 mm thick by mean of nuts/bolts check nuts and washers of brass as shown in electrical plate No.3 of SSR part including necessary excavation and earth work. Gt Pipe 15 mm bore light grade for watering with Funnel wire mesh and protection to earthing strip shall be provided with Gl pipe light grade 25 mm dia up to 7.5 m from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common sall etc & earth work in any strata PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick precast RCC cover slab 1:2: 4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-charge Note: GI strip upto 7.5 RM is included in the unit rate quoted
M&L for earth continuity conductor as aluminium strip 20 X 4 mm with saddles and fixing screws etc for roof conductors above ground complete all as specified and as directed
(PART - II)
Outsourcing of services round the clock ( consisting of three shifts) including Sundays and holidays and operation of Central type air conditioning plant of capacity 3 x 77 TR ( Two plants each to be run at a time and one will be kept as stand by) including all connected electrical items such as main switch, starter ,change over switch, MCCB, voltmeter, ammeter, panel board etc, cooling tower, condenser or water pump ,valve system, controling system, condenser, refrigerant line, adjusting valve, refrigerant valve, bypass valve, daily checking, leakage, checking noise, controlling temp. of plant, cleaning of plant and it's surrounding area etc, by one Ref Mech (Skilled) per shift for 03 shifts in a day all as per manufacturers instructions complete all as specified and as directed
(a) 1st year after certified date of completion of work
(b) 2nd year after certified date of completion of first year
(c) 3rd year after certified date of completion of second year
(d) 4th year after certified date of completion of third year
(e) 5th year after certified date of completion of fourth year
(f) Sixth (05 months after completion of 1(e) above) Notes :- (a) 24 Hour period will be considered as a day, AC Plant shall be operated as and when needed and as directed and the same shall be operated in three shifts of 08 hours each i.e, 1st shift 0600 to 1400 Hours, 2nd shift 1400 Hours to 2200 Hours and 3rd shift from 2200 Hours to 0600 Hours of the next day as directed by Engineer-in-Charge. Contractor shall employ one operator (skilled) per shift. (b) Daily maintenance as per manufacturer's instr for AC plants (c) Log sheet for recording daily running hours run shall be provided / maintained by the contractor in their respective installation and same will be checked by the Engineer-in-charge periodically and daily by JE.
(d) General cleanliness / removing of vegetation of respective installation surrounding area to be done regularly and the cost of the same deemed to be included in the quoted rate. (e) Cleaning of the cooling tower, package unit, compressor, condenser complete, cleaning of all parts with brush, washing with detergent powder refit all parts after cleaning and making good the disturbed area. The cleaning shall be carried out twice in whole contract as directed. The same shall deemed to be included in the rate quoted for above mentioned central AC plants. (f) The rates quoted shall be inclusive of all taxes ,cess, levies etc as applicable including GST (g) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date.
(h) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (j) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also. (k) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more.
(PART - III)
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of chilled water type central air conditioning plant of capacity 3X 77 TR installed at Production Block NAY-G, comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years i.e after expiry of defects liability period of 24 months after completion of all phase II tests) complete all as specified and as directed and shown below:-
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of first year period
(c) 3rd year after expiry of second year period Notes:- (i) The comprehensive maintenance for a period of 36 months wef satisfactory completion of guarantee (defects liability period) for the work at Production block at NAY-G. (ii) The Contractor shall be responsible for periodical maintenance including renewal / replacement of parts, fittings/fixture filling of refrigerant gas etc required for smooth functioning of the plant as per manufacturer's instructions. (iii) The cost of spare parts, consumable items, repair/replacement of equipments/machinery with labour charge for carrying out comprehensive maintenance are deemed to be included in the unit rate quoted by the contractor above.
HVAC Engineering Co
AIRFRAME
Pneumatic Engineers Pvt. Ltd.
M/s Vijay Airconditioning Pvt Ltd
somnath engineering corporation
Comfort Systems
M/S J J ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .