Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 CrAccepted-AOC | ₹13.0 Cr Quoted ₹13.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹14.7 CrRejected-AOC | ₹14.7 Cr | L2 | Rejected-AOC Rejected |
Tender Value
₹12.2 Cr
EMD Value
₹24.4 L
Closing Date
8 Jan 2020, 12:00 pmClosed
EXECUTIVE ENGINEER PWD WD II DIU FORT ROAD DIU.
EXECUTIVE ENGINEER PWD WD II DIU FORT ROAD DIU.
Site Development Works and Remaining Works for Phase I and II for Education Hub at Diu. 5th Call.
2019_DIUDT_635_1
53 2019 2020
Open Tender
Civil Works - Buildings
180 days
DIU
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Yes
EXECUTIVE ENGINEER PWD WD II DIU
₹24.4 L
Yes
13 Oct 2020
31 Dec 2019
8 Jan 2020
31 Dec 2019
8 Jan 2020
31 Dec 2019
Civil Works :
Excavation for foundation up to 1.5m depth including sorting out and stacking of useful materials and disposing off the excavated stuff up to 50 Meter lead.(A) Loose or soft soil. The drawing is to be referred for further details and as directed by EIC.
Excavation for foundation for depth from 1.5m to 3.0m including sorting out and stacking of useful materials and disposing off the excavated stuff up to 50 Meter lead.(A) Loose or soft soil. The drawing is to be referred for further details and as directed by EIC.
Providing and fixing White stone bela masonry block in course in foundation and plinth with stone of approved quality in cement mortar1:5 ( 1 Cement: 5 course Sand) include the packing the joints complete. The drawing is to be referred for further details and as directed by EIC.
Providing and laying controlled cement concrete M 250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, base of columns and Mass concrete.The drawing is to be referred for further details and as directed by EIC.
Providing and laying controlled cement concrete M 250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in ( C ) Slabs, landing Shelves, Balconies, lintels, Beams, girders and cantilever up floor two level. The drawing is to be referred for further details and as directed by EIC.
Providing and laying controlled cement concrete M 250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in ( D) Columns, Pillars posts and struts up to Floor two level. The drawing is to be referred for further details and as directed by EIC.
Providing TMT Bar FE 500/500D reinforcement for R.C.C work including bending, binding and placing in position complete up to floor two level. The drawing is to be referred for further details and as directed by EIC.
Providing and fixing Masonry work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure above plinth level upto floor two level in cement mortar 1:5 (1 cement:5 fine sand) complete as per technical specification. The drawing is to be referred for further details and as directed by EIC.
Providing and laying 15 mm thick cement plaster in single coat on rough (similar) side of single/half brick walls for interior plastering upto floor two level and finished even and smooth in cement mortar 1:3 ( 1 Cement : 3 sand). The drawing is to be referred for further details and as directed by EIC.
Providing and laying Vitrified tiles 8 to 10mm thick, 24" x 24" in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finishing with flush pointing in white cement. The drawing is to be referred for further details and as directed by EIC.
Providing and laying Vitrified tiles 8 to 10mm thick, 24" x 24" in skirting risers of steps and dedo on 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry. The drawing is to be referred for further details and as directed by EIC.
Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation . The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre-coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles of approved texture (Fine Fissured/Cosmos/Spintone) in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge.Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of 0.50 (Minimum) for Fine fissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation.
Dismantling tiles of stone floors laid in mortar including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift and as directed by EIC.
Demolition including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift. (i) RCC work and as directed by EIC.
Demolition of brick work and stone masonry including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift. (ii) in cement mortar and as directed by EIC.
Supplying of graded stone aggregate of following sizes (1) Graded stone aggregate 25mm to 90mm size for soling work of plinth and road or any were as per detail given by consultant and as directed by EIC.
Spreading the stone aggregate for consolidation and W.B.M. including filling the interstices to required camber and gradient ( excluding spreading of Blindage) (ii) 40mm to 63mm size aggregates (H.B) and as directed by EIC.
Providing and laying cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth. The drawing is to be referred for further details and as directed by EIC.
Providing and laying 25mm th. River Finish Kota stone slab ledge / flooring / cladding. Rate to include for making nosing, polishing visible edges, etc. Rate includes filling the joints with cement slurry admixed with pigment to match the shade; including holes for railing fixing and required grooves. Joints and sizes as per architectural drawings. The stone edges to have uniform thickness and to be free of any bending. Rate also to include araldite required to fix the same to the M.S. Fabrication. The rate shall be inclusive of making of holes. The rates shall include for applying of zycoseal or any other waterproof transparent coating of approved make on Kota flooring.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow, tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and applying anticorrosive treatment with polymer base material to steel reinforcement including descaling the dust and applying the preventive coating of approved make ( for RCC structures near coastal area only) etc. complete. The drawing is to be referred for further details and as directed by EIC.
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads, above rate are including the stocking up up to 2.5 M in to Rock with bore hole in rock(Length of pile for payment of excavated earth with all lifts and leads (Length of pile for payment shall be measured up to bottom of pile cap). 600 mm dia piles and as directed by EIC.
Providing and laying floor protection with floor gasd with tape and other necessary accessories. The drawing should be referred for further details and as directed by EIC.
Providing and rebaring 12mm dia with necessary accessories. The drawing should be referred for further details and as directed by EIC.
Providing and rebaring 16mm dia with necessary accessories. The drawing should be referred for further details and as directed by EIC.
Providing and core cutting 75mm dia with necessary accessories. The drawing should be referred for further details and as directed by EIC.
Providing and core cutting 100mm dia with necessary accessories. The drawing should be referred for further details and as directed by EIC.
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length of the pile to be embedded in the cap etc. all complete, including removal of excavated earth with all lifts and lead, above rate are including the stocking up upto 1.2 M in to Rock with bore hole in rock (Length of pile for payment shall be measured upto bottom of pile cap.) 350mm dia piles and as directed by EIC.
Providing and filling in plinth with sand under floors, including watering, ramming, consolidating etc. complete. The drawing is to be referred for further details and as directed by EIC.
Providing and fixing Signages with LED letters with Samsung LED modules and monopole as per design of size 6.11m along with power supply having specifications 60,000 hrs warranty for LED bulb and water proof and 1 year replacement warranty and as directed by EIC.
Providing and laying polished Kota stone slab flooring over 20 mm (average) thick base of cement mortar 1:6 (1-cement, 6-coarse sand ) or L.M. 1:1.5 ( 1-Lime putty, 1.5-Coarse sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing etc. complete. (A) 25 mm thick. The drawing is to be referred for further details and as directed by EIC.
Providing and laying 20mm thick sand faced cement plaster on wall up to height 10 M above the ground level constituting of 12mm thick backing coat of cement mortar 1:3 ( 1 cement : 3 sand) and 8mm thick finishing coat of cement mortar 1:1 ( 1 cement : 1 sand) etc. complete. The drawing is to be referred for further details and as directed by EIC.
Providing and Applying two coats of Birla (white cement based) or Asian (acrylic lapy-putty) or equivalent & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. The drawing is to be referred for further details and as directed by EIC.
Providing and Finishing walls with Acrylic Smooth interior paint on wall surface ( two coats) to give an required shape even shade after throughly brushing the surface to remove all dirt, and remains of loose powdered materials etc. complete. The drawing is to be referred for further details and as directed by EIC.
Providing and laying Washed stone grit plaster on exterior walls height up to 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 4 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings, sample make and approved with consultant complete as per specification and direction of Engineer-in- charge (payment for providing grooves shall be made separately). The drawing is to be referred for further details and as directed by EIC.
Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove with anodized aluminium strip of 50 micron and 0.45kg/ Rmt approved size and colour with all material and labour and cutting with machine etc. Complete as per specifications and direction of the Engineer-in-charge : 13.73.1 15 mm wide and up to 15 mm deep groove
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
Providing and laying broken china mosaic flooring for terrace using 12 to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 ( 1 cement : 3 sand ) to Palin or slope and to be tempered to bring mortar crème out up to surface using white cement including rounding off junction and extending them up to 15 cm along the wall, cleaning with water and oxalic acid etc. as directed. The drawing is to be referred for further details and as directed by EIC.
Providing and fixing rolling shutters with perforations of approved make made of 80mm wide MS laths interlocked together through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with pushh-pull operation including the cost of hood cover and spring etc. complete. (A) Shutters having width below 3.5m. The drawing is to be referred for further details and as directed by EIC.
Providing & laying factory made precast U shaped surface drain USD 450 mm of FUJI Silvertech make or equivalent, having inner dimensions width: 450 mm, height: 450 mm, length: 2000 mm, load carrying capacity: 5 tonne wheel load of vehicle confirming JIS and meeting IS requirements, made of high performance self compacting M-40 grade concrete and reinforcement Fe 500. The product shall have groove of width: 10-20 mm and depth: 25 mm as per relevant standards on both sides for joining two precast units using cement mortar 1:3 proportion/ non shrink grout suitable. The precast drain should have lifting inserts at appropriate locations for safe installation. The rate includes transportation on specific location at site and placing in line, level, gradient and plumb with necessary testing commissioning etc. complete as per manufacturer's specification and satisfaction of Engineer-in-charge. The drawing is to be referred for further details and as directed by EIC.
Providing & laying factory made precast lid of FUJI Silvertech make or equivalent having length: 500 mm, width: 572 mm, thickness: 130 mm, suitable for placing on precast U shaped surface drain of 450 mm X 450 mm, load carrying capacity : 5 tonne wheel load of vehicle confirming JIS and meeting IS requirements, made of high performance self compacting M-40 grade concrete and reinforcement Fe 500. The product shall have anti-skid finish at top.The precast lid should have lifting arrangment at appropriate locations for safe installation. The rate includes transportation on specific location at site and placing in line, level, gradient and plumb with necessary testing commissioning etc. complete as per manufacturer's specification and satisfaction of Engineer-in-charge.
Providing & Laying of factory made FUJI brand Precast Box Culvert having 1200 mm (W) X 1400 mm (H) in to in dimension units of 2000mm length, confirming to Japanese Industrial Standards (JIS) & meeting IS requirements, made by using advanced Japanese Technology having High Performance Self Compacting Concrete of M40 Grade and using Fe 500 reinforcement bar designed for 5 T wheel Load with 200 mm to 3000 mm cushion above it. Product also includes, male & female jointing system, groove for fixing rubber gasket, flange coupling jointing arraignments with and special in-built hanging brackets at appropriate locations for faster & safe installation of the product. The drawing is to be referred for further details and as directed by EIC.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 Metre. The drawing is to be referred for further details and as directed by EIC.
Providing and laying (to level or slopes) and jointing reinforced concrete light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. 450mm. The drawing is to be referred for further details and as directed by EIC.
Providing and laying (to level or slopes) and jointing reinforced concrete light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints complete. 150mm. The drawing is to be referred for further details and as directed by EIC.
Providing and laying corrosion-resistant chain manufactured from mild steel used in marine and high temperature environments of size 25mm along with fixing it with the rainwater pipe by holes. The drawing is to be referred for further details and as directed by EIC.
Providing and laying in trenches galvanised mild steel tubes (medium grade) of the following nominal bore, and tube fitting (earthwork in trenches to be measured and paid for separately) 80mm. The drawing is to be referred for further details and as directed by EIC.
Supply and spreading of unpolished pebbles of size 25mm including supply of necessary labour, material and equipment complete with carting, loading, storage, stacking of debris and casting upto any lead and lift. The drawing is to be referred for further details and as directed by EIC.
Supplying of Bolt "L" 3 to 4 size iron (7.5 cms to 10 cms). The drawing is to be referred for further details and as directed by EIC.
Fixing metallic tower bolts of sizes with screws etc. complete (tower bolts and screws to be paid under separate items). The drawing is to be referred for further details and as directed by EIC.
Providing and fixing MS grills of required pattern to wooden frames of windows etc. with MS flats at required spacings and frame around, square or round bars with round headed bolts and nuts or by screws - Plain Grill. The bars and flats are to be cleaned thoroughly to be polished, PU coated and painted. The drawing is to be referred for further details and as directed by EIC.
Applying priming coat over new steel and other metal surface after and including preparing the surface by thoroughly cleaning, oil, grease, dirt and other foreign matter and scoured with brushes fine steel wood, scrapers and sand paper with ready mixed priming paint brushing red lead. The drawing is to be referred for further details and as directed by EIC.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleaning the surface of all dirt, dust and other foreign matter. The drawing is to be referred for further details and as directed by EIC.
Providing formwork of oridnary timber planking so as to give rough finish including centering, shuttering, strutting, and propping etc. height of centering and propping below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in ( A ) Foundations of footings base of columns etc. and mass concrete. The drawing is to be referred for further details and as directed by EIC.
Providing formwork of oridnary timber planking so as to give rough finish including centering shuttering, strutting, and propping etc. height of centering and propping below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in ( B) Flat Surfaces such as soffits of suspended floors slabs landings and the like (1) Floors upto 200mm in thickness. The drawing is to be referred for further details and as directed by EIC.
Providing formwork of oridnary timber planking so as to give rough finish including centering shuttering,strutting, and propping etc. height of centering and propping below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in ( C) Vertical surface such as walls (any thickness) partitions and the like including attached buttresses and string course & the like. The drawing is to be referred for further details and as directed by EIC.
Providing formwork of oridnary timber planking so as to give rough finish including centering shuttering, strutting, and propping etc. height of centering and propping below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in (G) Columns Pillars posts and struts (1) Square, Rectangular, Polygonal in plan. The drawing is to be referred for further details and as directed by EIC.
Providing formwork of oridnary timber planking so as to give rough finish including centering shuttering,strutting, and propping etc. height of centering and propping below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in (H) Sides and soffits of beams, beam haunchings, cantilever girders bressumers and lintels not exceedding 1 M in depth. The drawing is to be referred for further details and as directed by EIC.
Providing and fixing flush door shutters, solid core construction with frame of first class hardwood with cross board and face veneer or plywood face panels, including anodised aluminium butt hinges with necessary screws. Non-decorative type and block board core anodised aluminium butt hinges in flush door shutters 35mm thick. The drawing is to be referred for further details and as directed by EIC.
Extra for using both side laminated sheet of 1mm thick in any color and design given by consultant and as per the details shown in the drawing and as directed by EIC..
Supplying locks godrej mortice lock cover as shown in the drawing and as directed by EIC. Approved Make : Godrej.
Fixing metallic door handles or knobs for mortice locks with necessary screws etc. complete (Door handles/knobs and screws to be paid separately) as shown in the drawing and as directed by EIC. Approved Make : Godrej.
PLUMBING WORKS :- SUB HEAD-I CP & SANITARY , INTERNAL BUILDING AREA TOILET PLUMBING WORK:- Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Cera/Hindware/Parryware.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required ::Cera/Hindware/Parryware.
Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : Oval under counter type 550 X 400 mm.Make- Cera/Hindware/Parryware.
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsCera/Hindware/Parryware.
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.Cera/Hindware/Parryware.
Providing and Installation, testing and commissioning of C.P.brass single level basin mixer and brass nuts complete as required.Make : Jaquar / Equivalent 5011
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour,Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
Providing and fixing PTMT Bottle Trap for Wash basin and sink,Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bor
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm dia
Flexible pipe 32 & 40 mm dia
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia
Rectangular shape 453x357 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms.
Providing and fixing PTMT urinal cock of approved quality and colour, 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 610x510 mm bowl depth 200 mm
610x460 mm bowl depth 200 mm
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
Providing and Installation of C.P brass twin coat hook fixed on the toilet door with C.P brass screws complete as required .Model 1161 N Jaquar make / Equivalent make..
Providing and Installation C.P. brass grab bar 300 mm long with C.P brass screws complete as required .Model 1101 N Jaquar make / Equivalent make..
Providing and Installation C.P. 2-WAY Brass bib cock with including cp flanze, cp extension pease, C.P brass screws complete as required .Jaquar Florentine Series Jaquar make / Equivalent make..
Providing and Installation,testing and commissioning of bath area single lever divertor, including over head rain shower of 250 dian, bath spout, with all internal cp plante, fixures, cp extension pipe, 15 mm dia C.P. oncealed divertoe, with wall operating knob complete in all respects.Model florentine series Jaquar / Equivalent make
Providing and Installation,testing and commissioning of 15 mm dia C.P. Ablution health faucet with 1.0 m long SS extension pipe with wall hook and operating knob complete in all respects.Model 573 Jaquar / Equivalent make
Subhead II - Internal Drainage (Rainwater, Soil, Waste & vent Pipes & Fittings)Providing and fixing uPVC Soil, Waste pipes & Vent Pipe (IS: 13592 Class B) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good where required.(for Soil, Waste & vent pipe inside the building) 110mm OD
Providing and fixing uPVC RWP pipes as per IS 4985, 6kg/cm2 including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good where required.(for Drain & rain water pipe inside the building) 160 mm dia
110 mm dia.
Providing, fixing and testing uPVC pipes, confirming to IS 4985, Class -6kg/cm2 50 mm OD
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm OD
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm OD
Providing and fixing pVC SWR Nahni trap lS 14735 for drain - 100 mm diameter with jali of thc following nominal dronreter of self cleaRAng design with C.l scread down or hinged grating including the cost of cutting and making good the walls. etc. 110x 75mm trap size
P-Trap 110 x 110mm size
Providing and fixing centrifugal cast iron LAB waste waste pipe (IS: 3989) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with dripseal/lead joints including cutting chase or holes in walls and floors and making good where required.(for pipe inside the building) 75 mm dia
Providing & fixing in position CI P", S" trap of self cleaning design of following sizes for the embedded areas. Making proper connection with refined pig lead joints, cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required.100 mm inlet and 75 mm outlet
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :100mm dia pipe
75mm dia pipe
up to 50mm dia pipe
Subhead III - Internal Water Supply & Gas Piping WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC-SDR-11 plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.(Cold Water Supply Internal & External Piping Works) 15mm dia nominal bore equivalent to 12.44 ID
20mm dia nominal bore equivalent to 18.44 ID
25mm dia nominal bore equivalent to 23.42 ID
32mm dia nominal bore equivalent to 28.54 ID
40mm dia nominal bore equivalent to 33.78 ID
50mm dia nominal bore equivalent to 44.20 ID
80mm dia
100 mm dia
PE - AL - PE COMPOSITE PRESSURE PIPES HOT WATER SUPPLY WORKS INTERNAL & EXTERNAL WORKS Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-ALPE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80 0C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. including Concealed work, including cutting chases and making good the wall etc.1216 (16 mm OD) pipe
1620 (20 mm OD) pipe
2025 (25 mm OD) pipe
2532 (32 mm OD) pipe
3240 (40 mm OD) pipe
Providing and fixing 9 mm thick elestrometic nirial foam type insulation over pipes in wall chase and filling the wall chase as per manufacture's specifications for hot water insulation. (Superloan/tharmaflex/Accoflex make) for 15mm dia pipe
1620 (20 mm OD) pipe
2025 (25 mm OD) pipe
2532 (32 mm OD) pipe
3240 (40 mm OD) pipe
Providing and Fixing, overlep on the exposed hot water pipe insulation covering protection of the insulation by overlep of PVC Pipe ISI marked brand as per IS 4985 6 kg/sq. cm complete with PVC Fittings conforms to IS: 14735-99 & fittings dimensions as per DIN 19531 & DIN 19534, Rubber ring conforms to IS:5382 & clamps, hinges, nut bolts including (External Exposed Hot water pipe protection of following nominal outside diameter waste/soil pipes complete as per specifications, 40 mm dia for 20mm & 25mm hot water piping system)
50 mm dia for 32mm hot water piping system)
75 mm dia for 32mm hot water piping system)
Supply, installation, testing & commissioning of gunmetal, male or female threaded isolation control valve (Wheel Valve), confirming to IS 778, PN 1.0, with necessary specials, union, nipples etc., to complete the job. ( Zoloto/ Audco/ R.B.) 15 mm dia.
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80mm dia
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15mm dia
20mm dia
25mm dia
Providing and fixing gun metal non- return valve of approved quality (screwed end) VerticaL 25 mm nominal bore
32mm dia
40mm dia
50mm dia
80mm dia
Supplying, fitting & fixing Auto air valve (Gunmetal body with inside PP float Spring type auto operation type) as per of PN-6 class of approved IS code including fittings etc. complete. ( Zoloto/ Audco/ R.B./ Spirex) 15mm dia
20 mm dia
25 mm dia
GAS PIPING Providing and Fixing 14 guage Copper Gas piping on all marked points as marked on tabls/drawing 3/8 mm dia
25 mm dia
LPG GAS PIPING Providing and Fixing G.I.-seamless pipe Class-C guage Gas piping on all marked points as marked on tabls/drawing 15 mm dia
20 mm dia
25 mm dia
32mm dia
40 mm dia
50 mm dia
Providing & Installing of LP gas supply system, Manifold as specified and detailed on drawings comprising of ISI OR IS approved as per the standard. 40mm dia.
Providing & Installing of LP gas supply system, Manifold as specified and detailed on drawings comprising of ISI OR IS approved as per the standard. 50mm dia.
Providing & Installing of Stainless steel braided pig tail including necessary fittingsto BS. 669-1 (1989)15mm dia. braided pigtail for gas cylinders
Providing & Installing of Stainless steel braided pig tail including necessary fittingsto BS. 669-1 (1989)15mm braided pigtail for gas serviceoutlets
Providing and Fixing of LPG-Gas Isolation Valve with ISI /IS mark as approved by standard. 15mm.
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Gas leak detection system with normally open type emergency shut off valve, leak detectors, push button switch and control panel In 15mm dia. pipe with push button switch
In 50mm dia. pipe with push button switch
Providing and fixing of approved Gas leak detectors at low level
Providing and fixing of approved Gas leak detectors at high level
Providing and fixing of approved Gas Regulation valve 15 mm dia. Second stage regulation valve
Providing and fixing of approved Gas Regulation valve 40 mm dia. Second stage regulation valve
Providing and fixing of approved Gas Regulation valve50 mm dia. First stage regulation valve
Equipment and accessories 28 kg. gas cylinders with fixing devices
Providing and Fixing of Table Valve with copper flexible pipe of ISI mark
Providing and Fixing of Pressure Guage of ISI brand
Providing and Fixing of valves in Main line - 25mm dia
Providing & fixing PN 6 butterfly valve including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. 100 mm dia
80 mm dia
50 mm dia
Providing, fixing, jointing and testing in HDPE PE-80- drip irrigation, piping work including in exposed works and under ground complete with all plugs, clamps including transition fittings between HDPE to CPVC pipe including jointing the pipe and fittings Teflon tape on threaded ends including clamping as required by engineer in charge and manufactures specification for proper completion of work. ( For IRRIGATION DRIP Piping Works) 25mm dia
20mm dia
15mm dia
Supply, installation, testing & commissioning of gunmetal, male or female threaded isolation control valve (Wheel Valve), confirming to IS 778, PN 6, with necessary specials, union, nipples etc., to complete the job. ( Zoloto/ Audco/ R.B.) 15mm dia
20 mm dia
25 mm dia
Subhead V - External Sewer & Rain water Drainage Providing laying (to level or slopes) and jointing reinforced concrete Light duty non pressure pipes l.S. class NP2 of the fofiowing internal diameter. with coilais and butt ends prepared for collar joints including testing of joints complete.(B) 150mm (uoto 10 ton)
lProviding laying (to level or slopes) and jointing reinforced concrete Light duty non pressure pipes l.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm (uoto 10 ton)
Providing laying (to level or slopes) anc iointing: reinforced' concrete Light. duty nor pressure pipes l.S. class NP2 of the following jnternai -.diarneter: . with coliars rnd butt ends prepared for Collar joints ncluding testing of joints cornplete.(D) 300mm (uoto 10 ton)
Providing laying (to level or slopes) anc iointing: reinforced' concrete Light. duty nor pressure pipes l.S. class NP2 of the following jnternai -.diarneter: . with coliars rnd butt ends prepared for Collar joints ncluding testing of joints cornplete.(D) 450mm (uoto 10 ton)
Constructing Manhole with R.CC. top slab in 1:2:4 mix (l-cement :2-coarse sand : 4-grad-ed stone aggregate 20mml nominal size) foundation concrete 1:3:61 mix (1-cement : 3- coarse sand :6- bats 40 + 50mm size) inside ptasteri 15mm thick with Cement Mortar 1:5 (.1- Cement : S-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone regate 20mm nominal size) finished smooth complete including curing andl festing (i) lnside size 900mm x 1200mml and 1.5M. deep including C.l. cover with frame size' S60mm''diameler' tolal,,weig-ht of cover and frame to be not less thanl 128 kgs. (Wt, of Covei 64 Kg. and Wt.,of frame 64 Kg.(A) With 230mm thick wails of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:S (l- Cement: S-Coarse sand) (1) A type depth 0.90 Metre for 150mm diameter sewer.
Constructing Manhole with R.CC. top slab in 1:2:4 mix (l-cement :2-coarse sand : 4-grad-ed stone aggregate 20mml nominal size) foundation concrete 1:3:61 mix (1-cement : 3- coarse sand :6- bats 40 + 50mm size) inside ptasteri 15mm thick with Cement Mortar 1:5 (.1- Cement : S-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone regate 20mm nominal size) finished smooth complete including curing andl festing (i) lnside size 900mm x 1200mml and 1.5M. deep including C.l. cover with frame size' S60mm''diameler' tolal,,weig-ht of cover and frame to be not less thanl 128 kgs. (Wt, of Covei 64 Kg. and Wt.,of frame 64 Kg.(A) With 230mm thick wails of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:S (l- Cement: S-Coarse sand) (2) B type depth 1.50 Metre for 150mm diameter sewer.
Constructing Manhole with R.CC. top slab in 1:2:4 mix (l-cement :2-coarse sand : 4-grad-ed stone aggregate 20mml nominal size) foundation concrete 1:3:61 mix (1-cement : 3- coarse sand :6- bats 40 + 50mm size) inside ptasteri 15mm thick with Cement Mortar 1:5 (.1- Cement : S-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone regate 20mm nominal size) finished smooth complete including curing andl festing (i) lnside size 900mm x 1200mml and 1.5M. deep including C.l. cover with frame size' S60mm''diameler' tolal,,weig-ht of cover and frame to be not less than 128 kgs. (Wt, of Covei 64 Kg. and Wt.,of frame 64 Kg.(A) With 230mm thick wails of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:S (l- Cement: S-Coarse sand) (3) C type depth 2.25 Metre for 150mm diameter sewer.
(A) With 230mm thick wails of brick msonry using brick having crushing strength not less than 35Kg. i Sq.cm. in Cement Mortar 1:5 (1- Cement: 5- Coarse sand) (4) D type depth 3.1S Metre for 150mm diameter sewer.
(l) Extra rate for constructing B-8, masonry. for every additional depth of 0.1M. or Parl thereof over item No.24.27 (l) for deprtl-r frurrr 0.9M to t.SM.
(ll) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. GR Part thereof over item No.Za.27l (l) for depth from 1.S0M. to 2.25M
(lll) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No. 24.27 (lli) for deptn from i.2s,f,l to s.tS[I.
Providing and fixing cast iron steps of size 500mm x 150mm x 22.5mm and painting with two coats of Anti-corrosive paint etc. comolete.
Providing and erecting at the site of worl steel vehtilating column of 150m interna diameter and 12.20 Metre High from G.L. to bottom of top grill including C.l. grill and base plate bolts and nuts etc. and :xcavation in foundation of size 120cm. x 120vcm. x 165cm. and filling the pit with irst layer of cement concrete 1:3:6 mix (1 :ement :3-coarse sand :6-9raded stone rggregate 20mm norninal size) of 12Ocm.X 120cm. x 90cm. and remaining pit with B.B.C. 1:3:6 mix (1-cement :3-coarse sand:6-8 brick bats 40+50mm size) and roviding fillet in Cement concrete 1:2:4mix (1-cement :2- coarse sand :4-graded tone aggregate 20mm. nominal size) at G.L.and 3 coats of silver paint etc.complete up to 10 ton
ConstructingbrickmasonrychamberforundergroundC.I.Inspectionchamberandbendswithbriockshavingcroshingstrengthnotlessthan35Kg.Cm2inC.M.1:5C.I.coverwithframe(Lightduty)455mmx610mmintenaldimensionstotalweightofcoverwithframetobenotlessthan38Kg.(Wt.ofcover23Kg.)andWt.offrame15Kg.)(R.C.C.topslabewith1:2:4mix(1-cement:2-coarsesand:4-gradedstoneaggregate20mmsize)foundationconcrete1:5:10insideplaster15mmthickwithcementmortar1:3finishedsmoothwithafloatingcoatofneatcementonwallsandbedconcreteetc.complete.(ii)Insidedimensions500mmx700mmand450mmdeepforpipe line with one or two inlets. (upto 10 ton)
Constructing brick masonry chamber for underground C.l. lnspection chamber and bends with briocks having croshing strength not less than 35K9. CmZ in C.M. 1:5 C.l. cover with frame (Light duty) 455mm x 61Omm intenal dimensions total weight of cover with frame to be not less than 38i(9. (Wt. of cover 23 Kg.) and Wt.of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster] 1Smm thick with cement mortar 1:31 finished smooth with a floating coat ofl neat cement on walls and bed concretel otc. complete.(iii) lnside dimensionsl 600mm x mm and 450mm deep for pipel lines with three or more inlets. (upto 101 ton
Providing and fixing S.W. gully trap with C.f. grating brick masonry chamber and water tight C.l. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps.(B) 150mm x 100mm size p or R tvpe
Providing and fixing ball cock, of approved. quality as directed,(A) Copper Metal (ii) 50mm dia.
l(B) Providing sock pit of 5.00 Cu.M. lVolume including excavating and filling lbrickbats with dry masonry work at top for 45cm. height including covering the top with stone including providing vatas in C.M. 1:3 with finishing curing etc. complete as directed. (upto 10 ton)
Providing and fixing of MS IS specified puddle sleeve of water tank the size of the sleeve is 50mm to 250mm dia, sleeve is incusing puddle, with flanze and nut and bolt jointing, all sleeve souring water proof GP-2 grouting is necessary.
Providing and fixing of FRP or MS with epoxy medium duty duty grating cover for water drain channel of the size is around 450mm wide with frame and cover , including all supports and necessary fixing work etc. com. ( HP Strong Drain, Thermodrain or Eq. Make )
Providing and fixing of FRP or MS with epoxy heavy duty duty grating cover for water drain channel of the size is around 450mm wide with frame and cover , including all supports and necessary fixing work etc. com. ( HP Strong Drain, Thermodrain or Eq. Make )
Providing and fixing of FRP medium duty duty 600mm dia cover for waste water drain chamber & MAnholes covers with including FRP medium duty farme for the same , including all supports and necessary fixing work etc. com. ( HP Strong Drain, Thermodrain or Eq. Make )
Providing and fixing of FRP heavy duty duty 600mm dia cover for waste water drain chamber & MAnholes covers with including FRP heavy duty farme for the same , including all supports and necessary fixing work etc. com. ( HP Strong Drain, Thermodrain or Eq. Make )
Providing and laying Cement concrett 1:5:10 (1-Cement : S-Fine sand :10 Graded stone aggregate 40mm nomina size) bedding for stoneware pipes o following internal diameters witl necessary formwork and curing complete.all under ground drain line. (166mm Ave bed thicknessl
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 0.45m. wide and 3.00 mtr in depth,including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m., disposed earth to be levelled and neatlydressed. All kind of soil
Sub Head -WATER SUPPLY, EQUIPMENTS:- Supplying and installation of the centralized Hot water Solar System, of the indirect heating system, including , all intercollecting, piiping, va;ves, safety released valve, internal all controls, cabeling work, electrical back of the ystem, inclufing hot watre circulating system pump, base frame of the system, all system MS/SS storage vasssel of the main storage system, insulation the system including internal piping,loading unloading up to the terrace level in the scope of the work, the sytem is required for prassureize appplication, also all necessary civil support etc complete job. ( SOLAHEART, BANCHMARK, AO -SMITH, TATA BP MAKE) SOLAR HOT WTARE SYSTEM SYSTEM CAPACITY :- 500 LTR.
Pressure Pumps :- Supplying, installing, testing and commissioning of SS vertical multistage hydropneumtic centrifugal pump. Nos. pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. The installation shall be complete with all necessary ancillaries & accessories including base plate complete as required. Cost shall be inclusive of MCC panel and wiring/cabling from pump to panel PLC drive operation, auto operation,dry run protection, interconnection piping, including booster tank etc comp. ( Groundfos/ITT lowara Make) Terrace Level.Domestic Hydro Pump Flow rate : 5m3/hr each pump flow Nos. (1 Working + 1 Standby)Head : 35 Mts Booster Tank:- 150ltr. Capacity
Supplying, installing, testing and commissioning of SS storage type water cooler, including 25ltr/hr. R.O. plant, with all necessary filters, booster pumps, controls, cabeling works, the storage capacity of the cooler is min. 80 ltr,. The ccoller water inlet , overflow is required auto operation type, shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. ( Water Cooler :- 80 Ltr. Cap. Bluestar, Power H2o, Voltas Make)The cost shall be inclusive of providing salt for the testing and operation of system before handover to the owner.
Sub Head VIII- Decentralised Waste Water Treatment System DEWAT (STP) (MBBR/SIBFsystem) for Sewage Treatment, It includes civil works of Septic Tank, Anaerobic Baffled Reactor, Anaerobic Baffled Filter and Plant gravel Filter with capacity of 200 KLD.It shall be designed for minimum 2-3 years of desludging period. BOD and COD should be maintained as per Central Pollution control standards. It includes all civil cost for construction of treatment system and terturay UV treatments, internal all sewage pump, dewatering pumps and the all types of piping with electrical and mechnical valve and components to be supplied. Outlet should be maintained to directly use for Irrigation purpose and For Flushing after filtration. The system shall consist of 4 compartments Preliminary Treatment - settler, Secondary Treatment - ABR + AF, Tertiary Treatment- PGF, Collection Tank ( Contractor shall submit design and technical submittal for approval, prior to execution)( In the scope of work the inlet collection sump and the product water storage tank is not included in the scope of civil job, it should be in the part of cicivl works)
Providing, fixing, testing & commissioning of vertical MSEP/ FRP filter with adequate dirt holding capacity, complete with initial charge filter media. Including concrete foundation with cement plaster complete as required. The filter shall also be provided with set of internals for soft water inlet and bottom collecting system. Complete with frontal piping (heavy) and butterfly valves designed on 1.50 m / sec velocity.Activated Carbon Filter Filtration Rate 14000L/Sqm/Hr Working pressure 3 Kg/Sq.cm Capacity : 6 LPS Note : Treated Water used should be as per CPC parameters for flushing EWC and Urinals. Cost shall includes all interconnecting piping
ETP Plant for Treating Lab Waste with capacity of 50 cum/day ( 6 to 8 hr.Operation)
Supply, installation, testing & commissioning of centralized R.O. plant of primary & secondary treatment with on line U.V. filtration along with built in booster pumps all interconnection piping, supports and valve and other electrical requirement ,along with inbuilt controls with necessary accessories, safety valve, air valve, drain arrangement, all instrumentation, base frame, necessary electrification, etc. complete for Kitchen Cooking & Drinking Water supply. (Ion Exchange, Paintair, Power H2o Make)The Bidder Should taken care Distilled water Inlet quality Parameter as recommended, In IS/ WHO/ Guide line for the Process Design.End Water parameter:- ( As per IS Recommendations )TDS:- <500mg.ltr/ Total hardness CaCO3 :- < 50 ppm./ PH: 6.5 – 8.0Chlorides:250mg.ltr/ Calcium:75mg.ltr/ Manganese : 0.1mg.ltr/ Sulphate: 200mg.ltr/Nitrate: 45mg.ltr/ Fluoride: 1.0mg/ltr/ Alkalinity:200mg.ltr/ Turbidity: 5NTU/Colour:5 hazen unit/ Odor: Unobjectionable.The Scope is also included:- Raw Water to lifting pimp, R.OPLant - to R.O.product water Tank.,(All Piping, COntrol & Valves etc. For Product water Capacity : 500 /hr capcity..( Location At U.G. Tank above Plant Room Lvl.) (The scope of cover is not included Raw water Tank and treated water tank is not included.)
Supply, installation, testing & commissioning of Oil and grase seprator unit ready made unit, of ACO german made or equ. As approved by authority, The work is included of the all interconnection piping, bypass arrangment of valves, controls etc. complete. ( Capacity of Oil Seprator- Grease 5 ltr/sec cap. , The each Model should be connected one commercial sink and additional dish washer area of 1ltr/sec cap.)
Providing & fixing in position 25 mm dia lawn hydrants consisting of 25 mm dia Ball valve, GI nipple and threaded hose receiver complete as required.
Constructing brick masonry chamber for underground C.l. lnspection chamber and bends with briocks having croshing strength not less than 35K9. CmZ in C.M. 1:5 C.l. cover with frame (Light duty) 455mm x 61Omm intenal dimensions total weight of cover with frame to be not less than 38i(9. (Wt. of cover 23 Kg.) and Wt.of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster] 1Smm thick with cement mortar 1:31 finished smooth with a floating coat ofl neat cement on walls and bed concretel otc. complete.(iii) lnside dimensionsl 600mm x mm and 450mm deep for pipel lines with three or more inlets. (upto 101 ton ( For Hydrant Valve Chambers)
Providing and constructing of Grease Trap 1800 x 1200 x 1200 mm size ( Internal ) overall size with inlet & outlet connection with 1st class brick 230mm thick in cement mortar 1:4 ( 1cement : 4 coarse sand ) inside 12 mm thick plaster with cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound and finished with a floating coat of neat cement inside surface and 15 mm thick rough plaster 1:3 ( 1Cement : 3 sand ) outside foundation concrete 1:4:8 ( 1 cement : 4 coarse sand 8 graded stone aggregate of 40 mm nominal size) 115mm thick brick baffle wall with 150 x 150 mm opening at 200mm above invert level, 3mm thick S.S., perforated tray of size 600x300mm size with two 8mm dia S.S. rod of 800mm long , and 8mm thick M.S. plate cover ( 750x 450mm) fixed on 40x40x6 mm size angle iron frame, epoxy coated with lifting arrangement fixed to both including necessary excavation back filling, disposal of surplus earth, providing and fixing of polypropylene coated manhole steps complete as per standard design.
Providing, fixing , testing and commissioning water meter with direct reading dial in KL with all necessary fitting such as threaded pieces, unions pressure gauge, isolation cock, flanges piece for future removal, flanges / unions complete with all necessary testing charges and obtaining test certificates from municipal authorities, on following size pipe lines (1 no. strainer shall be provided at inlet & outlet and cost shall be inclusive for the same). The meter shall comply to ISO 4064 standard, feasible for class B or Class A installation. 80 mm dia (CI)
Supplying, installing, testing and commissioning of SS vertical multistage hydropneumtic centrifugal pump. Nos. pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. The installation shall be complete with all necessary ancillaries & accessories including base plate complete as required. Cost shall be inclusive of MCC panel and wiring/cabling from pump to panel VFD drive operation, auto operation, dry run protection, interconnection piping, including booster tank etc. comp.Domestic Hydro Pump Flow rate : 10m3/hr each pump flow Nos. (2 Working + 1 Standby)Head :45 Mts( Required for Treated Water Transfer Pump)
Flushing Hydro Pump Flow rate :8m3/hr each pump flow Nos. (2 Working + 1 Standby)Head :45 MtsRequired for : Flushing Water Transfer Pump
Flow rate : 50 LPM Nos. (1 Working + 1 Standby)Head : 40 MtsRequired for : Flushing Water Transfer Pump from DEWAT tank to Pump room
Do - as - Above but for Flow rate : 2 LPS Head : 10 Mts Solid Handling : 50 MM Location : External Area Purpose : External Sewage & Strom drain MOC : CI Impeller & Shaft ( 1W + 1S)
Do - as - Above but for Flow rate : 3 LPS Head : 10 Mts Solid Handling : 50-100 MM Location : External Purpose : External Swer & Storm water MOC : CI Impeller & Shaft ( 1W + 1S)
WATER TREATMENT PLANT Supplying, installing, testing and commissioning of SS vertical centrifugal pump. Nos. pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. The installation shall be complete with all necessary ancillaries & accessories including base plate complete as required. (1Working + 1Standby)Flow rate : 6 LPS Nos.Head : 30 MtsRequired for : Raw water treatment
Providing, fixing, testing & commissioning of vertical MSEP filter with adequate dirt holding capacity. Fabricated from MS sheet as per manufacturer's specifications complete with initial charge filter media including painting inside with two coats of non toxic epoxy and with one coat of zinc chromate two coats of synthetic enamel paint outside. Including concrete foundation with cement plaster complete as required. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping (heavy) and butterfly valves designed on 1.50 m / sec velocity. Filter for Domestic Water services.Filteration Rate 20000L/Sqm/Hr Filteration Rate 20000L/Sqm/Hr Working pressure 3 Kg/Sq.cmCapacity : 6 LPS
Activated Carbon FilterFilteration Rate 14000L/Sqm/HrWorking pressure 3 Kg/Sq.cmCapacity : 6 LPS
Providing, fixing, testing & commissioning of MSRL water softening plant (suitable for 3 Kg/Sqcm working pressure) complete with initial charge with T-40 NA Resin, multiport valve with built in ejector for controlling all operations), regeneration system and HDPE tank, pressure gauge at inlet, outlet and back wash (Nos. with isolation cock), valves, fittings and water hardness testing kit & associated works. Softener shall be suitable for the following duty: Raw water hardness 5000 Mg/LTreated water harness 100 Mg/LRegeneration Period 10 Hrs.Capacity : 10m3/hr flow
Supplying, installing, testing and commissioning of dosing system (for domestic water treatment plant) consisting of one HDPE tank of 100 litres capacity with a positive displacement diaphragm dosing pump having variable flowrate of 0-6 lph. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall be speed & stroke control Asia LMI / equivalent make. The cost shall be inclusive of providing salt for the testing and operation of system before handover to the owner. The Water Treatment plant cost shall inclusive of all interconnection and piping from Raw water tank to Treated water tank, inclusive of valves and accessories
Fire Fighting (Internal Riser External) FIRE EXTINGUISHERS AND EXIT SIGNS Supplying and fixing following optical signs having its own independent power source etc. complete (supply from batteries) “Fire Exits” ( Size 365 x 119 x 84 mm or nearest )
Fire exit signs of standard size photo luminous type.(glowing in dark type)
Providing and fixing portable fire extinguishers of approved make ISI marked of following Capacity at the places shown on Drawing & mentioned in CFO letter Dry chemical powder of 6 kg capacity as per IS-15683
Dry chemical powder of 9 kg capacity as per IS-15683
ABC water type fire extinguisher of 9ltr/. capacity as per IS:15683
Mechanical Foam type fire extinguisher of 50 ltr. capacity as per IS: IS:15683
Water-Co2 type fire extinguisher of 9 Lit.capacity as per IS:15683
Co2 type fire extingyisher of 4.5 kg. Capacity as per IS:15683
Fire buckets of 9 lit. capacity 3 Nos.)in each set including stand with paint etc. complete
INTERNAL HYDRANT SYSTEM :Supplying, installation testing and commissioning of the following GI C’ class Pipe for overhead pipes with flanges welded and with heavyclamps,hangers,brackets or pipe supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc.Complete to make the system operative as required by LPA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fastners. The work includes excavation in all types of soilsand back filling and condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primerfor over heads pipes and for underground pipe shall [It includes providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS:10221 for corrosion protection of pipes that will be laid under the ground Corrosion.] Note : The piping installation has to be put to hydraulic test to1.5 times 150mm
Providing and fixing hydrant stand posts of 80 mm dia. With flanges and accessories and supply, fixing single headed 63 mm dia G.M. Hydrant Valve in the courtyard IS:5290 Including 2 coats of approved enamel paint (red) over a coat of primer, complete with 2.1/2” ‘Morris’ pattern instaneous couplings including 80mm dia. Pipe of 2 mtr. length etc. complete.
Providing & fixing 2 Nos.65mm dia RRL hose pipe as per IS 636 TAC/ LPA approved of 15 m standard length each with hose cabinet of suitable size approved pattern and size including gun metal male and female Coupling duely bound with copper wire with gun metal nozzle etc. complete installed on MS angle frame which is partially burried in ground in PCC
Supplying and fixing specially designed gunmetal orifice plates on hydrant outlets of landing valves including distant pieces of suitable size for adjustment of delivery pressure of 3.5 kg/ sq.cm as required by LPA complete with necessary companion flanges,nuts, bolts, gaskets etc. complete.
Supply and installation, testing and commissioning of Isolation valves ( heavy ) tested to ISI marked ,PN1.6 tested to 500 psi hydraulic pressure with necessary , companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open and shut position as per fire practice etc. complete. 150 mm dia
100 mm dia
Supply and installation, testing and commissioning of Isolation valves ( heavy ) tested to ISI marked ,PN 1.6 500 psi hydraulic pressure with necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open and shut position to be installed underground with suitable size brick work/RCC valve chamber and MS plate cover as per fire practice etc. complete. 100 mm dia
Gate valve ISI Marked and approved make 200 mm size
150 mm size
80 mm size
50 mm size
NRV ISI Marked and approved make 200 mm size
150 mm size
50 mm size
Supply, installation testing and commissioning pressure switch assembly with following components components Approved pressure switches with required cable
Ball Valve 50 mm dia
Ball Valve 15 mm dia
15 mm dia pipe
50 mm dia pipe
Pressure gauge with ball valve
Charges for liasoning with CFO and getting all approvals and permissions & NOC 's required for fire fighting at various stages & after completion of the project. (All official and receipted payments would be submitted and Reimbursed)
EXTERNAL HYDRANT SYSTEM :Supplying, installation testing and commissioning of the following GI C’ class Pipe for overhead pipes with flanges welded and with heavyclamps,hangers,brackets or pipe supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc.Complete to make the system operative as required by LPA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fastners. The work includes excavation in all types of soilsand back filling and condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primerfor over heads pipes and for underground pipe shall [It includes providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS:10221 for corrosion protection of pipes that will be laid under the ground Corrosion.] Note : The piping installation has to be put to hydraulic test to1.5 times 150mm
Providing and fixing hydrant stand posts of 80 mm dia. With flanges and accessories and supply, fixing single headed 63 mm dia G.M. Hydrant Valve in the courtyard IS:5290 Including 2 coats of approved enamel paint (red) over a coat of primer, complete with 2.1/2” ‘Morris’ pattern instaneous couplings including 80mm dia. Pipe of 2 mtr. length etc. complete.
Providing & fixing 2 Nos.65mm dia RRL hose pipe as per IS 636 TAC/ LPA approved of 15 m standard length each with hose cabinet of suitable size approved pattern and size including gun metal male and female Coupling duely bound with copper wire with gun metal nozzle etc. complete installed on MS angle frame which is partially burried in ground in PCC
Supplying and fixing specially designed gunmetal orifice plates on hydrant outlets of landing valves including distant pieces of suitable size for adjustment of delivery pressure of 3.5 kg/ sq.cm as required by LPA complete with necessary companion flanges,nuts, bolts, gaskets etc. complete.
Supply and installation, testing and commissioning of Isolation valves ( heavy ) tested to ISI marked ,PN1.6 tested to 500 psi hydraulic pressure with necessary , companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open and shut position as per fire practice etc. complete. 150 mm dia
100 mm dia
Supply and installation, testing and commissioning of Isolation valves ( heavy ) tested to ISI marked ,PN 1.6 500 psi hydraulic pressure with necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open and shut position to be installed underground with suitable size brick work/RCC valve chamber and MS plate cover as per fire practice etc. complete. 100 mm dia
MAIN FIRE PUMP ROOM ,TANK AND ACCESSORIES Supplying & installing completely testing & commissioning main fire pump (electrical driven) for hydrant main & sprinkler main with cast iron casing & bronze or phosphor bronze internal parts, make as approved by TAC/CFO for fire duty, complete with coupling guard necessary RCC foundation, capable of discharging 2280 lt/min against 70 meter head metre head against all losses complete electrically operated TEFC 3-ph, 440-V, 50 Hz, 1500 RPM motor of ‘B’ class winding, make as approved by TAC with automatic star/ Delta starter complete with 1 – phasing preventor & No volt release as per LPA requirements foundation bolts, suitable cable entry gland box for -AL cable (70 sq.mm) pressure gauges & wired for automatic start of the water pump on drop of pressure in the wet riser/ hydrant and sprinkler system. The motor starter and pump should confirm to LPA / BSES & and IE Regulations. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Motor to be of continuous rating etc. complete.
Supplying & installing completely testing & commissioning main fire pump (diesel driven)with cast iron casing & bronze or phosphor bronze internal parts, make as approved by TAC/CFO for fire duty, complete with coupling guard, exhaust piping (@40 mtr. length, MS C class ) with necessary fittings, supports, clamps, insulation , etc.. complete RCC foundation, capable of discharging 2280 lt/min against 70 meter head metre head against all losses complete with suitable diesel engine ,auto start facility with battery,nessesary wiring, fuel tank ,exhaust system, foundation gauges & wired for automatic start of the water pump on drop of pressure in the wet riser/ hydrant and sprinkler system. The motor starter and pump should confirm to LPA / BSES & and IE Regulations. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Motor to be of continuous rating etc. complete.
Supplying & installing 1100-V grade PVC insulated & sheathed armoured aluminium cable, IS certified, 3.5 core x 95 sq.mm AYFY size cable for electric motor in Rate should include for necessary hardware for fixing, crimping including Dowels, copper lugs, supply of brass cable glands, all material and labour etc. complete.(Star Delta for Main hydrant Pump)
Supplying & installing PVC insulated & sheathed armoured copper cable for Jockey pump, IS certified, 3C x 4 sq.mm YWY size cable for electric motor in Rate should include for necessary hardware for fixing, crimping including Dowels, copper lugs, supply of brass cable glands, all material and labour etc. Complete. (Star Delta for Jockey Pump)
Providing and fixing Power wiring with 2 core x 1.5 sq.mm. PVC armoured copper cable for wiring pressure switches, etc. Including all required material and labour etc. Complete. Note : All cable sizing are tentative. It shall be designed according to actual motor rating & got approved for consultant / Client before procurement.
Providing, fixing, testing and commissioning of precharged air vessel (size 450 mm dia & 2000 mm height) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valve.
Supplying, installing, testing and commissioning of jockey pump with discharge 180 lpm against head 70 mtr. pump on slab as per site conditions and instructions of site engineer-in-charge including proper fixing, drop pipe of necessary length with strainer, sluice valve, non return valve, pressure gauge, pressure switch etc. complete including all necessary valves and fittings up to main header on discharge Line. The electrical motor for the pump should comply as per Specification In Sr,no.1 of this section.
Supplying and fixing 4 way Fire Brigade service inlet of size 150 mm dia. with 4 No. 63mm (2.1/2") size GM male outlets ( bronze male coupling) including metallic cover of mild steel and glass front, indicator plates,150mm BFV and schematic mimic diagrams on metallic plate for easy operation as directed by Architect etc. complete to UGR
Supplying, installation testing and commissioning of the following GI C’ class Pipe for overhead pipes with flanges welded and with heavyclamps,hangers,brackets or pipe supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc.Complete to make the system operative as required by LPA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fastners.The work includes excavation in all types of soils and back filling and condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primerfor over heads pipes and for underground pipe shall [It includes providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS:10221 for corrosion protection of pipes that will be laid under the ground Corrosion.] Note : The piping installation has to be put to hydraulic test to1.5 times200mm. Complete200mm(Suction and discharge header)
150mm(Aboveground)
Providing, installing testing & commissioning following components in pump room Strainer of approved make 200 mm size (For MAIN hydrant and sprinkler pump suction)
Size : 150 mm
80 mm size(for jockey pump suction)
Gate valve ISI Marked and approved make 200 mm size
150 mm size
80 mm size
50 mm size
NRV ISI Marked and approved make 200 mm size
150 mm size
50 mm size
Supply, installation testing and commissioning pressure switch assembly with following components components Approved pressure switches with required cable
Ball Valve 50 mm dia
Ball Valve 15 mm dia
15 mm dia pipe
50 mm dia pipe
Pressure gauge with ball valve
FIRE SPRINKLER SYSTEM :Supplying, installation testing and commissioning of the following GI C’ class Pipe for overhead pipes with flanges welded and with heavyclamps,hangers,brackets or pipe supports (all with screwed/welded joints)as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc.Complete to make the system operative as required by LPA / TAC authorities the pipes will have to be laid and fixed in trenches on walls,ceilings, into brick walls or RCC with lead anchor fastners. The work includes excavation in all types of soilsand back filling and condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primerfor over heads pipes and for underground pipe shall [It includes providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS:10221 for corrosion protection of pipes that will be laid under the ground Corrosion.] Note : The piping installation has to be put to hydraulic test to1.5 times of the working pressure.25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Providing and fixing 15 mm gunmetal sprinkler head with quartz bulb and set to operate at specified temperature pendent/ upright/ side wall as per instruction and fixing with loctite.Pendent Type 68 C
Side Wall Type 68 C
Upright Type 68 C
Rossete Plate
Providing & fixing 25mm dia gunmetal inspecting & testing assembly with ball valve(3 nos.), gunmetal sight glass, by pass valve & connected to drain line.
Providing and fixing brass ball valve full bore type with plastic coated lever approved quality, tested to 20 Kg.cm.sq.50 mm dia
Providing and fixing cast iron wafer type Butterfly valve of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications.100 mm nominal bore
Providing and fixing electricaly operated flow indicating switches model System Sensor in sprinkler branch line on each floor with necessary junction box installed in accessible place (Wiring from switches to panel and stair case pressurisation not included)100 mm dia
Providing and fixing dial type pressure gauge with isolation cock and copper pipe on main header Dial diameter 100 mm celebration 0-15 / sq. cm.
Providing and fixing 25 mm dia single acting air release valve with screwed inlet.
Providing and fixing cast iron dual plate wafer type non return valves.100 mm dia
Providing and laying 2 x 2.5 sq mm copper conductor PVC sheathed armoured cable for connecting fire alarm Panel to flow switch.
Supply ,Installation Testing Commisioning of Wet Chemical System for Kitchen system with nessary Nozzles,Piping and Wet Chemical storage WITH Detection system in hood Considering considering 20 Points of Detection and 15 Points of supprsion nozzles.
(Central Court Yard_Lawn Sprinjler System) SITC of Gear Drive Pop up Sprinkler 8-12 meter Radius Rotor with Check Valve of Hunter/Rain Bird / Toro make.
(Central Court Yard_Lawn Sprinjler System) SITC of Gear Drive Pop up Sprinkler 4-8 meter Radius Rotor with Check Valve of Hunter/Rain Bird / Toro make.
SITC of Spray Pop Up Sprinkler 3 to 5 Meter Radius of Hunter/Rain Bird / Toro make
SITC of Swing Joing 3/4" of Hunter/Rain Bird / Toro make
SITC of Swing Joint 1/2" of Hunter/Rain Bird / Toro make
SITC of PP Clamp Saddle 3/4" PN 16 of Astore/Cepex make
SITC of PP Clamp Saddle 1/2" PN 16 of Astore/Cepex make
SITC of Double Acting Air Release Valve 1" of ARI/AZUD/R.B. OR EQ. make
Point Wiring Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. with medium class Rigid PVC pipe and accessories
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. with medium class 25 MM DIA Rigid PVC pipe and accessories
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed. with medium class 25 MM DIA Rigid PVC pipe and accessories
Do as above but for Secondary light point controlled by same two way switch
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [III] For 16A Plug with 2-4 sq.mm Cu. Wire
Point wiring for Exhaust Fan with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
Shiftting for existing switch board, plug, data, telephone point etc. to different location.
Removing of Exixsting Light fixture,Fan, Speaker, Smoke detector, etc..
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (c) 32 mm
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (d) 40 mm
RACEWAYS & JUNCTION BOX Providing and fixing 1.5 mm thick steel sheet factory fabricated pre galvanized raceway with internal partition of the following sizes including providing removable 3 mm thick GI cover, knock out holes and fixing accessories earthing with 8 SWG copper earth wire complete as required including floor supports, bends, access boxes, tap off boxes and cross over as per specification and site requirement. The floor junction box height adjustable from 60 to 70 mm with GI Powder coated trap and frame fitted with 2+3 mm Trap + GI load plate in line with EN 50085 suitable for 1.5 KN loading class complete with GI metal duct entries on all four sides and necessary recess for accomodating floor finsihing material. SITC of Under floor pregalvanized junction box with knock outs suitable for 60x25mm and 90x35mm three PVC duct entries in all the four sides. The box is suitable for 70mmscreed height with a powder coated trap and frame (2+3mm) suitable for Marble flooring with 10mm recess. Dimensions:357x357x70mm
SITC of Under floor pregalvanized junction box with knock outs suitable for 60x25mm and 90x35mm two PVC duct entries in all the four sides. The box is suitable for 70mm screed height with a powder coated trap and frame (2+3mm) suitable for Marble flooring with 10mm recess. Dimensions:260x260x70mm
SITC of Under floor pregalvanized junction box with knock outs suitable for 60x25mm / 90x35mm single PVC duct entry in all the four sides. The box is suitable for 70mm screed height with a powder coated trap and frame (2+3mm) suitable for Marble flooring with 20mm recess. Dimensions:185x185x70mm
SITC of 90 mm x 35 mm high impact UPVC material (hammer test according to DIN EN 60068-2-75) in compliance with the relevant standard to EN 50085-2-2 floor Trunking as per specification of OBO Better man make with all fixing accessories.
SITC of Vertical connection box made of galvanised sheet steel for feeding the cables from the Distribution Box through the under floor ducts suitable for 3 nos of 90mmX35mmUPVC ducts as per specification & drawing of OBO Bettermann make cat. no. VAB 60259035 with all fixing accessories
SITC of Wall trunking with cover made of Lead free polyvinylchloride ( ROHS complied ) with a standard length of 2 metre, size 110mm height x 60mm depth suitable for fixing switches and sockets.The trunking shall be non flame propogating and shall comply with DIN EN 50085 -2-1. The trunking shall have all accessories like partition, Internal corner cover, External corner cover , T intersection cover, Flat Angle cover , cover clip etc for cable management. The trunking shall be supplied with cover retainers at regular intervals. The gird plates need to be fixed on the cut covers and wiring accessories and face plates need to be fixed / clipped on to the same without the back box...of OBO bettermann or Legrand make
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete.
MAINS : ( not for Point wiring ) Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. Supplying and Laying of 4 nos. of 16 sq mm Cu. FRLS flexible wires with 2 nos 6 sqmm Cu. FRLS flexible wires to be drawn in 2 nos. of 50 mm dia Pipe
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size Supplying and Laying of 4 nos. of 6 sq mm Cu. FRLS flexible wires with 2 nos 2.5 sqmm Cu. FRLS flexible wires to be drawn in 2 nos. of 40 mm dia Pipe
Supply, Erecting, testing and commissioning of only TPN D.B. PPI type with space for FPMCB as incoming and space for DPELMCB and 8 SPMCB as outgoing per phase (i.e. 12 way per phase D.B.) of Hensel Make KV9448M
Distribution Board-SPN Supply, Erecting, testing and commissioning of SPN D.B. PPI type with space for DPELMCB as incoming and 8 SPMCB as outgoing per phase (i.e. 12 way D.B.) of Hensel Make KV9112M
MCB Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark 6 to 32 A SP MCB
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 25 to 32A / 100 mA DP ELMCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 6 to 32A FP MCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 63 A FP MCB
SITC of 100 Amp. FP MCCB ( 16 KA ) with both side Spreader Link
SITC of IP65 Polycarbonate enclosure for FP MCB
SITC of 40Amp FP Isolator with Enclosure
SITC of 63Amp FP Isolator with Enclosure
SITC of 16A x 250 Volt single phase Power socket outlet point having IP rating of IP:65 at convenient location with MCB.for outdoor duty.
SITC Of 32A x 250 Volt single phase Power socket outlet point having IP rating of IP:65 at convenient location with MCB.for outdoor duty.
SITC Of 32A x 415 Volt three phase Power socket outlet point having IP rating of IP:65 at convenient location with MCB.for outdoor duty.
SITC Of 63A x 415 Volt three phase Power socket outlet point having IP rating of IP:65 at convenient location with MCB.for outdoor duty.
Cable Tray Supply and fixing GI ladder type cable trays, with radial bends, T Junctions, supports of the following sizes as per specification with a all required Hardware. Of OBO Betterman make 400 mm Wide ( 100 mm x 100 mm x 2 mm thick ) Runners 25 x 100 x 25 x 2 mm Rungs 20 x 40 x 20 x 2 mm 250 mm C/C
Supply and fixing of perforated type pregalvanized GI cable trays of the following sizes Of OBO Betterman make 300 mm Wide ( 100 mm x 100 mm x 1 mm thick )
Supplying , fabricating and installation of various sizes MS race way / junction boxes/clamps/hangers for Cable Tray, Light Fixture made out of specified size sheet/Angle/Flat/rod/ channel etc as per design with all necessary accessories like bend, junction boxes, coupler, Anchor fastener, Bolt Nuts, etc.. & work from MS structure for other work with anchor fastener of Hilti make and necessary hardware with necessary welding has to be done to complete the job from ISA / ISMC / PLATE. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved and recommended by consultant. Complete in all respect to be installed at any height with all necessary arrangements. Contractor has to complete the work up to satisfaction of Consultant
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 150 sq.mm x 3.5c Al. XLPE Arm. Cable
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 95 sq.mm x 3.5c Al. XLPE Arm. Cable
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 25 sq.mm x 4 c Al. XLPE Arm. Cable
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 16 sq.mm x 4 c Al. XLPE Arm. Cable
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 10 sq.mm x 4 c Al. XLPE Arm. Cable
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 6 sq.mm x 3 c Al. XLPE Arm. Cable
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 6 sq.mm x 4 c Cu. XLPE Arm. Cable
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 6 sq.mm x 3 c Cu. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with earthing. 150 sq.mm x 3.5 c Al. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with earthing. 95 sq.mm x 3.5c Al. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with earthing. 25 sq.mm x 4 c Al. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with earthing. 16 sq.mm x 4 c Al. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with earthing. 10 sq.mm x 4 c Al. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with earthing. 6 sq.mm x 4 c Cu. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with earthing. 6 sq.mm x 3 c Cu. XLPE Arm. Cable
Light Fixtures & Fans Supply, Installation, Testing & Commissioning of Light Fixtures with all necessary Lamps, Ballast etc.. Complete in all Respect Contractor has to supply the fitting as per architect / Consultants final approval. ( all the lamps should be of intermediate color only) Supplying, erecting, connecting, testing and commissioning of following type Street Light Fixture with all necessary Hardware, Internal Wiring with Lamp, Ballast etc. all required accessories Complete in all respect. 1 x 28 W type light fixture with 28W lamp of Philips make TWG 207 / 1 x TL5 28W Adreno V2
SITC of Recessed LED downlight with 15W LED, luminous flux of luminaire minimum1000lm, CRI >80, 230V, direct light emission, Concrete housing with ceiling trim, in die-cast aluminium, white, satin diffuser, passive cooling, electronic control gear,Protection class I, IP20 / IP44ø make of Regent Lupo or XAL Meno round
SITC of LED type light fixture Indoor architectural light Fixture with all necessary Hardware, Internal Wiring with Lamp, Ballast etc... with all required accessories Complete in all respect, with minimum Lumen output of 100 Lumens / watt as per specification & drawing and as specified and approved by Consultant. Refer Special Conditions and Item Specification.
ITC of existing Light fixture and Fan
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having 3blades with aluminium blades with , canopy & 30 cms. down rod erected with 24/ 0.2, 3 core flexible wire with earthing.(Make shall be approved by Engineer in charge))
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
Exhaust Fans : Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers & square frame.
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM
PVC & HDPE Conduits Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed 25 mm dia pipe
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed 40mm dia pipe
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction CAT - 6
Supply and laying of PowerCat 6A U/FTP CM 4 Pair Cable, LSZH Sheath - Violet of specified make to be done in prelaid PVC pipe of 25 mm dia / raceway of specified make, but without the cost of raceway or pipe ( the wire is to be drawn from HUB \ Switch of respective area to outlet point ) with the cost of the crimping with material of make Legrand / Molex/ Systimax / Panduit / Siemon
Miscellaneous Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. For 4.5 Kg Capacity
Providing the A0 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
Providing the A1 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
Providing the A2 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
Providing the A3 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
Floor / Loft Mounted Dry Scrubber for Kitchen Exhaust Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor / Loft mounted cabinet type Scrubber unit with DIDW Backward curved Centrifugal fan as per specification with drive & drive package of following capacities Necessary starter shall be in scope of HVAC Contract. 11800 CFM / 65 mm TSP For Kitchen
GI Sheet Metal work Supply, fabrication, installation, balancing and commissioning of factory fabricated ducts as per “SMACNA” Standards specifications - Supply, Fabrication, installation and testing of Ractangular sheet metal ducts in accordance with the approved shop drawings and as required by the specifications 20 Gauge
22 Gauge
24 Gauge
Powder coated Extruded Aluminium Diffuser with out aluminium volume control dampers.
Powder coated Extruded Aluminium Diffuser with aluminium volume control dampers.
Powder coated Extruded Aluminium Linear Grilles of required air flow angles with out aluminium volume control dampers.
Powder coated Extruded Aluminium Linear Grilles of required air flow angles with black coloured aluminium volume control dampers
Supplying and erecting volume control damper made from 18 G G.I. sheet with adjustable arrangement for controlling the volume of air.
Insulation work Supply & Installation of Acoustic Insulation of ducts with XPE Open Cell Acoustic Insulation Material. 15 mm THK
DUCT THERMAL INSULATION Supply & Installation of Thermal Insulation of Ractangular ducts (within the building) with chemically cross linked closed cell Polyethylene foam insulation material with factory laminated Aluminium foil & as per detail specifications 9 mm THK (Supply Air Duct in Return Air Path)
Excavation of Foundation in Soft Murrum, Soil or Sand from 0.0 mtr. to 1.50 mtr depth including lifting laying in 90 mtr. Lead area as directed by EIC.
Carrying out super special chemical treatment for anti termite treatment as directed by EIC.
Rolling and consolidation of subgrade with roller of 8 to 12 tonnes capacity to required slope including removing of undualtion as directed by EIC.
Providing, of WBM sub base consisting of machine crashed B.T. stone metal of 63mm to 40mm grade stone aggregate of compacted thickness 150mm including using 20% stone screening Grit and stone dust as filler with power/road roller of as per specification consolidate the sub base to proper camber with vibratory road roller as per specification complete in all respect to required slope as directed by the Engineer-in -charge.
Spreading the stone aggregate for rolling and WBM including filling the interstices to require camber and Gradient excluding spreading of bindage (ii) 43mm to 63mm Size aggregate HB as directed by EIC.
Providing, Laying , spreading and compacting graded stone aggregates to Wet Mix Macadam 75mm compacted thick as per MORTH specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tippers to site, laying in uniform layers in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as directed by EIC.
Cleaning and brushing the Existing surface incl. removing of excess binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes to receive bitumious treatment complete in all respects as per specification as directed by EIC.
Providing and laying of hot bitumen coat on WMM surface including cleaning the road surface and spraying primer a the rate of 1kg/1sqm . Binder shall be confirming to the specifications complete in all respect to the entire satisfaction of Engineer-in-charge. Bitumen Grade VG - 30 pack as directed by EIC.
Providing and laying of hot bitumen coat on WMM surface including cleaning the road surface and spraying primer a the rate of 0.5kg/1sqm . Binder shall be confirming to the specifications complete in all respect to the entire satisfaction of Engineer-in-charge. Bitumen Grade VG - 30 pack as directed by EIC.
Providing and laying of B.M (Bitumen macadam )thickness 50mm with aggregate size 20mm wellgraded to 6mm , bitumen content 4.5 to 5 %by weight with hot bitumen tact coat of 7kg/10 m2 & rolling the same and compacting the surface while the mix is hot and in appropriate tempreature and maintaining the required slope, Bitumen Grade VG - 30 as directed by EIC.
Providing and laying cement concrete 1:3:6(1 cement : 3 coarse sand : 6 hand broken stone aggregates 20 mm. nominal size) and curing complete including cost of form work in foundation and plinth as directed by EIC.
Providing and laying Cement concrete work 1:2:4 ( 1 Cement :2 Coarse sand : 4 graded stone aggregates 20 mm nominal size ) and curing complete excluding cost of form work and reinforcement for reinforced cement concrete works in ( A ) foundation , footing , base of column Horizontal and vertical fins and mass concrete as directed by EIC.
Providing and Laying Chain link Fencing of Vertical M.S Pipe 50 mm dia and 3mts Height and at 3 mts interval erected in cement concrete foundation of 450x 450x 450mm with Chain Link Fence made of 10 gauge galvanized wire and size will be 50mmx 50mm. with Horizontal tie of M.S. Pipe of 35mm Dia at Top,Centre and bottom for the fencing throughout the periphery. Including one open able gate 900mm wide and 2100mm in ht.incl.of two coats of oil paint on M.S Structure as directed by EIC. Approved Makes : Surfex International, Bajaj Sports, Syncotts International.
Providing and laying Synthetic - ITF Approved - material to be used should be from 8 layer full cushion synthetic surface which consists of 1 layer of Resurfacer 5 layers of dense rubber cushion and 2 layers of colour with line marking according to the international standards as directed by EIC. Approved Makes : Surfex International, Bajaj Sports, Syncotts International.
Providing and fixing jackets and net post with premium net. The net is 1 m wide and 9.50 to 10 metres long (with 25 to 50 cm on each side of the side bands), made of 10 cm square black mesh. At its top a horizontal band, 7 cm wide, made of two-fold white canvas, is sewn along its full length. Each extreme end of the band has a hole, through which passes a cord, fastening the band to the posts for keeping its top taut. Within the band, a flexible cable fastens the net to the posts and keeps its top taut. At the bottom of the net there is another horizontal band, 5cm wide, similar to the top band, through which is threaded a rope. This rope fastens the net to the posts and keeps its lower part taut as directed by EIC. Approved Makes : Surfex International, Bajaj Sports, Syncotts International.
Supplying of graded stone aggregate of following sizes (1) Graded stone aggregate 25mm to 90mm size for soiling work of plinth and road or any were as per detial given by consultant and as directed by EIC.
Filling in plinth with sand under floors, including watering, ramming, consolidating etc. complete. (more than 10 ton) as directed by EIC.
Providing and laying cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 hand broken stone aggregates 40mm nominal size) and curing complete excluding the cost of form work in foundation and plinth as directed by EIC.
vatsal construction co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid