| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹2.8 Cr+₹6.8 L (2.48%)Rejected-Finance | ₹2.8 Cr+₹6.8 L (2.48%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹2.8 Cr+₹9.1 L (3.31%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹2.8 Cr+₹9.1 L (3.31%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹2.9 Cr+₹17.6 L (6.42%)Rejected-Finance | ₹2.9 Cr+₹17.6 L (6.42%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹3.0 Cr+₹23.2 L (8.44%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹3.0 Cr+₹23.2 L (8.44%) | L5 | Rejected-Finance Not lowest |
Tender Value
₹3.1 Cr
EMD Value
₹3.8 L
Closing Date
19 Mar 2024, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
ADDITIONAL/ALTERATION TO NOVAL MANUFACTURING AND TECHNOLOGY GROUP (NMTG) BUILDING NO 93 OF DMRL, HYDERABAD (SPECIAL WORK)
2024_MES_640826_1
84007
Open Tender
Civil Works
Item Rate
365 days
DMRL KANCHANBAGH HYDERABAD
Class A
Category a i
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER RND KANCHANBAGH HYDERABAD
₹3.8 L
Yes
17 May 2024
6 Feb 2024
26 Mar 2024
6 Feb 2024
19 Mar 2024
5 Mar 2024
Amount
S&F venetian blinds (vertical type) of 100mm wide straps with all fittings (to be matched with existing patterns) & taking down old venetian blinds complete all as specified and as directed.
Providing and fixng stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc incluidng welding , grinding buffing, polishing and making curvature ( where ever required) and fitting the same with necessary stainless steel nuts and bolts complete incluidng fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size on the top of floor or the side of waist slab with suitable arrangement including distmantling old staircase railings complete all as specified and directed.
Dismantling roof including ridges, hips, valleys and gutters etc and stacking the materials within 50 metres lead of GS Sheets complete all as specified and directed.
Dismantling roof including ridges, hips, valleys and gutters etc and stacking the materials within 50 metres lead of asbestos cement sheets complete all as specified and directed.
Providing and fixing 0.56mm aluminium color coated profile with centre to centre pitch of 175mm , depth of 46mm, top crest width of 41mm, bottom valley width of 80mm overall profile width of 1144, cover width 1050mm at all heights, levels and locations colour finish aluminium alloy roofing sheets of alloy IS designation 31500, temper H x8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with hex cap headed self drilling/tapping stainless steel screws MS 50mm long with 3mm EPDM seal washer etc all inclusive of labour, scaffolding, T&P and sundries etc complete all as specified and directed.
Providing and fixing of precoated / mill finish aluminium ridges plain ( 500 -600mm) pre- coated colour or mill finish aluminium roofing accessories in 0.71mm thickness , alloy 31500 (IS designation) (Aluminium alloy (AA) 3004 (ISO designation) for colour coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15- 18 microns using self drilling/ tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete all as specified and directed.
Taking down existing roof treatment of any position with bituminous felt including plaster / loose concrete and removing rubbish to a distance exceeding 100 mtr and not exc 250 mtrs and roughening the surface of old concrete by picking, scraping, cleaning and washing down with water to remove all dust etc complete all as specified and directed.
Rendering 12mm thick on concrete / brick surface in CM 1:4 ( 1 cement : 4 fine sand) duly mixed with water proofing compound @ 3% by weight of cement and finished complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately.
Providing and carry out water proofing treatment to sound, moisture free concrete surface system includes proper surface preparation to remove loose dust, dirt, loose mortar ,curing compound etc carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100 plasticised expansive ground admixture supplies in 225 gm pouch,treatment of construction joints using polymer modified mortar prepare by using Nitobond SBR latects, application of polymer modified batta at floor, wall junction, filling of annular space around rain water outlet using conbextra GP2 non shrink cementoinous grouts. Andulated surface and pot hole shall be treated with epoxy mortar or putty to obtained sound/ levelled surface. Application of primer Nito proof WB primer on sound mortar slab surface. Followed by application of coat of Nito proof 600 PF liquid applied single component pitch free polyurithane coating supplied in 25 kg drum coverage @ 2.30 Kg/ m2 to achieve 1.5mm thickness in two coats complete incluidng all tools and tackles as per manufacturers specifcation. Coating shall be having crack bridging of 2mm, elongation ( ASTMD 124 ) greater than 600 percentage, tensile strength ( ASTM D412) , 2.5 N/MM2 , recovery from elongation ( ASTM D412) , 95 percentage, 85 percentage of solid content, tear resistance ( ASTM D624) , 15 KN/M, shore A hardness ( ASTM D2240) , 60, water vapour transimission not more than 1 gm / M2 ,water permeability ( DIN -1048) - NIL, services tempreature - 40'c to 70 dgree 'c , flash point greater than 70'C HSE guidelines :- It is recommanded to provide adequate general and local exhust ventilations, providing protection to Eye, face, Hand and other skin by wearing appropriate gloves, google, face child, respiratory protection etc. directed in SDS of the product.
Supply only integral water proofing compound complete all as specified and directed.
Renewing glass pane with putty, glazing clips and nails wherever necessary at bldg height of 10mtr incluidng racking out the old putty incluindg float glass panes of nominal thickness 5mm ( weight not less than 12.5 kg/ Sqm) complete all as specified and directed.
Renewal of old putty of glass pane (length) any thickness and height of bldg complete all as specified and directed.
Providing and fixing 4mm thick glass panes(weight not less than 10 Kg/sqm) with putty and glazing clips in steel doors/ windows, clerestory windows complete all as specified and directed.
Providing and fixing on wall face 110mm diameter unplasticised Rigid PVC rain water pipes conforming to IS : 13592 type 'A' incluidng jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion single socketed pipes complete all as specified and directed.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type 'A' incluidng jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion bend 87.5° 110mm complete all as specified and directed.
Demolishing brick work in cement mortar manually / by mechanical means includng stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead complete all as specified and directed.
Demolishing cement concrete manually / by mechanical means including disposal of materials within 50 metres lead complete all as specified and directed for the following :-
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix )
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix )
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 complete all as specified and directed.
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:6 complete all as specified and directed.
Providing Half brick masonry with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in super structure above plinth level upto floor V level in cement mortar 1:4 complete all as specified and directed.
Excavation work in ordinary soil by mechanical means ( hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottom lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soils as directed within a lead of 50 mtr complete all as specified and directed.
Providing and laying 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size derived from natural sources) in position cement concrete excluding the cost of centering and shuttering. All work upto plinth level complete all as specified and directed.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolanna / Ordinary Portlamd / portland slag cement admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete , to improve durability and workability without impairing strength including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engr-in- Charge for the following graded or concrete all works above plinth level upto floor V level complete all as specified and directed. (i) Concrete of M-25 grade with minimum cement content of 330 Kg/ Cum for beam, lintel
Centering and shuttering including strutting, propping etc and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers complete all as specified and directed.
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level :- (i) Thermo - Mechanically Treated bars of grade Fe- 500D or more
Steel reinforcement for RCC work ready to use "cut and bend" rebars of approved make from factory / workshop to construction site including placing in position and binding all complete above plinth level . (i) Thermo / Mechanically Treated bars of grade Fe- 500D or more
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster includng disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed.
15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete all as specified and directed.
15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete all as specified and directed.
6mm thick cement plaster 1:3 ( 1 cement : 3 fine sand) on ceiling surface finished with a floating coat of neat cement and thick coat of lime wash on top of ceiling when dry for bearing of RCC slabs and beams complete all as specified and directed.
Repairs to plaster of thickness 12mm to 20mm in CM 1:4 in patches of area 2.5 Sqm and under incluidng cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground complete all as specified and directed.
Distempring Two or more coats on new work with Ist quality acrylic distemper (ready mixed), having VOC ( Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture of required shade and colour complete as per manufacturer's specification complete all as specified and directed.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface complete all as specified and directed.
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete all as specified and directed.
Finishing wall New work ( Two or more coats applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm with 100 % premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives complete all as specified and directed.
Finishing walls with Acrylic smooth exterior paint on old work ( two or more coats applied @ 1.67 ltr/ 10 Sqm on existing cement paint surfaces over and including priming coat of exterior primer applied @ 0.90 kg/ 10 Sqm of required shade complete all as specified and directed.
White washing on new work ( three or more coats) with lime to give an even shade complete all as specified and directed.
White washing on old wall / ceiling surface ( one or more coats) with lime to give an even shade complete all as specified and directed.
Removing white, colour wash and existing treatment by scrapping and sand papering and preparing the surface smooth incluidng necessary repairs to scratches etc complete all as specified and directed.
Removing dry or oil bound distemper, water prooofing cement paint and the like by scrapping , sand papering and preparing the surface smooth including necessary repairs to scratches etc complete all as specified and directed.
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window cills, facias and similar locations of required size, approved shade , colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joint treated with white cement mixed with mateching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to edges to give high gloss finish etc at all levels complete all as specified and directed using :- (i) Granite stone slab colour black, chery / ruby Red , area of slab upto 0.50 Sqm
Providing edge moulding to 18mm thick granite stone counters, Vanities etc, incluidng machine polishing to edge to give high gloss finish etc complete as per design approved complete all as specified and directed
Reinforced cement concrete work in suspended floors, roofs slab supported on walls having slope up to 15° above plinth level up to floor five level, execulding cost of centering, shuttering finishing and reinforcement with 1 : 1 1/2 : 3 (Sand zone-III) derived from natural sources using 20mm nominal size stone aggregate complete all as specified and directed.
Centering and shuttering for suspended floors, roofs, slabs, landings, balconies and access platform including strutting, propping etc and removal of form complete all as specified and directed.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling CP brass/ stainless steel screws, all complete as per architectural drawings and the directions of engr -in- Charge. (Glazing, paneling and dash fasteners to be paid for separately) for fixed portion powder coated aluminium ( minimum thickness of powder coating 50 micron)
All as per item No 45 but for shutters of doors, windows & ventilators powder coated aluminium ( minimum thickness of powder coating 50 micron) including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required incluindg the cost of EPDM rubber/ neoprene gasket required ( Fittings shall be paid for separately)
Providing and fixing powder coated aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing window frame with CP barss / stainless steel screws @ 200mm centre to centre incluidng cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. Note :- Only weight of grill to be measured for payment.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings complete all as specified and directed. (i) With float glass panes of 5mm thickness (weight not less than 12.50 Kg/ Sqm)
S&F 12mm thick prelaminated particle board with decorative lamination on both sides conforming to IS 12823 Grade-I Type-II fixed in aluminium door, partition complete all as specified and directed.
Providing and fixing aluminium powder coated minimum thickness 50 micron round shape handle of outer dia 100mm with SS screws etc complete all as specified and directed.
Providing and fixing aluminiuim extruded section body tubular type universal hydraulic door closer ( having brand logo with IS 3564, embosed on the body, door weight upto 36 to 80 kg and door width from 701 to 1000mm) with double speed adjustment with necessary accessories and screws etc complete all as specified and directed.
Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality) for aluminium doors including necessary cutting and making good etc complete all as specified and directed.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level for :-
(i) PCC 1:4:8 ( 1 cement : 4 manufacutred sand derived from Recycled concrete aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size recycled aggregate (RA)
(ii) PCC 1:2:4 ( 1 cement : 2 manufacutred sand derived from Recycled concrete aggregate (RCA) upto 25 % : 4 graded stone aggregate 20 mm nominal size recycled concrete aggregate (RCA) upto 25 %)
M&L 2mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified and directed.
Providing and laying Double charge vitrified tiles polished finish size 600 x 600mm in floor in different size (thickness to be specified by the manufacturer ) with water absorption less than 0.08 % and conforming to IS : 15622 of approved brand & manufacturer, in all colours and shade , laid on and including 20mm thick cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/Sqm incluidng grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed.
Providing and laying vitrified tiles size 600 x 600 mm (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours & shade , in skirting, riser of steps , over and including 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg / Sqm including grouting the joint with white cement & matching pigments etc complete all as specified and directed.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer) of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engr -in- charge , in skirting, risers of steps and dados, over and including 12mm thick bed of cement mortar 1:3 (1 cement ; 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed.
Providing and laying rectified Glazed ceramic floor tiles of size 300 x 300 mm or more ( thickness to be specified by the manufacturer) of !st quality conforming to IS : 15622 of approved make in colours and shade except white, ivory, Grey, fume Red Brown, laid on and including 20mm thick cement mortar 1:4 ( 1 cement : 4 Coarse sand) , jointing with grey cement slurry @ 3.3 Kg/ Sqm incluidng pointing the joints with white cement and matching pigments etc complete all as specified and directed.
Dismantling tiles work in floors and roof laid in cement mortar including stacking materials within 50 metres lead for thickness of tiles 8mm to 25mm complete all as specified and directed.
Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5 m in all kinds of soil complete all as specified and directed.
Supplying and laying hard stone not exc 63mm gauge , deposited, spread and levelling in layers not exc. 15 cm thick, watered and rammed to true surface with broken stone or boulder complete all as specified and directed.
Cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 graded stone aggregate 40mm nominal size ) in pavements, laid to required slope and camber in panels as required incluidng consolidation finishng and tamping complete all as specified and directed.
Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete all as specified and directed.
Dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable materials and stacking of serviceable materials within 50 metres lead complete all as specified and directed.
Providing and fixing 12.5mm thick tapered edge Glass reinforced Gypsum board conforming to IS : 2095 (Part 3) : 1996 false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from MS sheets and galvanised with zinc coating of 120gms/ sqm (both side inclusive ) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x,0.50 mm of required length with nut & bolts of required size and other end of angle hanger fixed with intermediate GI channels 45 x 15 x 0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermediate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre with 25mm long dry wall screws @ 230mm interval including fixing of gypsum board of 12.5mm thick with white paper layer on face side of size 600 x 600 mm complete all as specified and directed.
Steel work in built up tubular hot finished welded type tubes ( round, square or rectangular hollow tubes etc) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer incluidng welding and bolted with special shaped washers etc complete all as specified and directed.
Providing and fixing steel work in gratings, frames, guard bars, ladders, railing, brackets, purlings, gates and similar works welded in built up sections / framed work, incluidng cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel as required complete all as specified and directed.
Random rubble masonary with hard stone in cement mortar 1:6 in superstructure above plinth level and upto floor five level , incluidng leveling up with cement concrete 1:6:12 (01 cement : 06 course sand : 12 graded stone aggregate 20mm nominal size at window sills, ceiling level and the like complete all as specified and directed.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc and stacking within 50 metres lead of area 3 sqm and below complete all as specified and directed.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc and stacking within 50 metres lead of area beyond 3 sqm complete all as specified and directed.
Taking out doors, windows and clerestory window shutters ( steel or wood) including stacking within 50 metres lead of area 3 Sqm and below complete all as specified and directed.
Supplying and fixing rolling shutters 80 x 1.25mm MS laths with 1.25mm thick top cover of approved make, made of required size, MS laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangement for inside and outside locking with push and pull operation complete includng the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS : 4454 Part -I and MS top cover of required thickness for rolling shutters complete all as specified and directed.
Providing and fixing factory made PVC door frame of size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corner and joined with 2 Nos of 150mm long bracket of 15 x 15mm MS square , the vertical door frame profiles to be reinforced with 19 x 19 mm MS square tube of 19 gauge, EDPM rubber gasket weather seal to be provided through out the frame. the door frame to be fixed to the wall using MS screws of 65/100 mm size complete as per manufacturers specification and direction of engr -in- charge
Providing and fixing factory made panel 30mm thick plan PVC door shutters consisting of frame made out of MS tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15 x 15mm for top & bottom tails. MS frames shall have a coat of steel primrs of approved make and manufacture. MS frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle of both side forming styles and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel, 10mm (5mm x 2) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, panelling of 5mm thick both side PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with 7mm (5mm + 2mm) thick x 15mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' channel using PVC solvent adhesive etc complete all as specified and directed.
Providing wood work second class teak work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) complete all as specified and directed..
Providing and fixing ISI marked 35mm thick including ISI marked stainless steel butt hinges with necessary screws flush door shutters conforming to IS : 2202 (Part -I) decorative type, core of block board construction with frame of Ist class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and directed.
Providing and fixing in position collapsible steel shutters with vertical channels 20 x 10 x 2mm and braced with flat iron diagonals 20 x 5mm size, with top and bottom rail of T- iron 40 x 40 x6mm, with 40mm dia steel pulleys, complete with bolts , nuts, locking arrangement, stoppers, handles including applying a priming coat of approved steel primer complete all as specified and directed.
Providing and fixing ISI marked MS pressed butt hinges 100 x 58 x 1.90mm bright finished with necessary screws etc complete all as specified and directed.
Providing and fixing aluminium tower bolts 150 x 10mm, ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc complete all as specified and directed.
Providing and fixing aluminium handles 125mm , ISI marked , anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc complete all as specified and directed.
Providing and fixing aluminium sliding door bolts 300 x 16mm , ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nut and screws etc complete all as specified and directed.
Providing and fixing aluminium Twin rubber stopper hanging floor door stopper, ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws complete all as specified and directed.
Providing and fixing 18mm thick both sides pre laminated cement bonded wood particle board as per IS : 15786 : 2008 of approved brand and shade with suitable full threaded steel screws etc in partitions, boxes, shelves, racks and cupboard , kitchen cabinet under kitchen counter etc all complete all as specified and directed.
Providing and fixing IInd class teak wood 50 x 20mm wooden moulded beading to door and windows frames, support to shelves with iron screws, plug and priming coat on unexposed surface etc complete all as specified and directed.
Providing MS continuous (piano) hinges of flap overall width 35mm, ISI marked IS : 3818 finish with nickel chromium plating grading-I as per IS: 1068 and fixing with necessary screws etc complete all as specified and directed.
Painting two or more coat on new wood work with synthetic enamel paint of approved brand and manufacture to give an even shade complete all as specified and directed.
Painting on new steel surface ( two or more coats ) incluidng a coat of approved steel primer ( red oxide primer) with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade complete all as speciifed and directed.
Painting with aluminium paint of approved brand and manufacture to give an even shade on new steel surface with two or more coats over a coat of primer complete all as specified and directed.
Dismantling wooden boardings in lining of walls and partitions thickness above 10mm upto 25mm , excluding supporting members but including stacking within 50 metres lead complete all as specified and directed.
Providing and fixing 18mm thick pre - laminateed ( one side decorative and other side balancing lamination) flat pressed 3 layers or graded particle board ( medium density) Grade I, Type II, IS : 12823 marked with necessary fixing arrangement and screws including drilling necessary holes for rawl plugs etc complete all as specified and directed.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates , bolts, nuts , cutting rivets, welding etc including dismembering and stacking within 50 metres lead complete all as specified and directed.
Dismantling steel work in trusses, rafters, purlins etc for every additional span of one metre or part thereof beyond 5 metres complete all as specified and directed.
Disconnecting damaged over head / terrace PVC water storage tank of any size from water supply line and removing from the terrace incluidng shifting at ground level complete all as specified and directed.
Providing and placing on terrace ( at all floor levels) polyethylene water storage tank, 1000 ltr capacity IS: 12701 marked , with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed.
Providing and placing on terrace ( at all floor levels) polyethylene water storage tank, 500 ltr capacity IS: 12701 marked , with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed.
Providing and fixng PTMT ball cock of approved quality , colour and make complete with Epoxy coated aluminium rod with LP / HP HD platic ball for :- (i) 20mm nominal bore 120mm long , weighing not less than 198 gms
(ii) 25 mm nominal bore , 152mm long , weighing not less than 440 gms
Providing and fixing gun metal gate valve 20mm nominal bore with CI wheel of approved quality ( screwed end) complete all as specified and directed.
Dismantling 15 to 40mm dia GI pipe internal work exposed on wall including stacking of dismantled pipes ( within 50 metres lead) complete all as specified and directed.
Providing and fixing GI pipes 15mm dia nominal bore complete with GI fittings and clamps i/c making good the walls etc concealed pipe including painting with anti corrosive bitumastic paint cutting chases and making good the wall complete all as specified and directed.
Providing and fixing 20mm dia nominal bore GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc complete all as specified and directed.
Providing and fixing water closet squatting pan ( Indian type WC pan) with 100mm sand cast iron P or S trap, 10 litre low level white PVC flushing cistern including flush pipe, with manually controlled device ( handle lever) conforming to IS : 7231, with all fittings and fixtures complete includng cutting and making good the walls and floors wherever required complete all as specified and directed for :- (i) white vitreous china orissa pattern WC, pan of size 580 x 440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet ( European type WC pan) with seat and lid , 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device ( handle lever), conforming to IS : 7231, with all fittings and fixtures complete , including cutting and making good the walls and floors wherever required complete all as specified and directed for :- (i) WC pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back single half stall urinal of size 580 x 380 x 350mm with 5 litre white PVC automatic flushing cistern, with fittings, standard size CP brass flush pipe , spreaders with unions and clamps ( all in CP brass) with waste fittings as per IS : 2556, CI trap with outlet gratings and other couplings in CP brass includng painting to fittings and cutting and making good the walls and floors wherever required complete all as specified and directed.
Providing and fixing white vitreous china flat back wash basin size 550 x 400mm with single 15mm CP brass pillar tap, wash basin with CI brackets, 32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required complete all as specified and directed.
Providing and fixing white vitreous china laboratory sink 600 x 450 x 200mm with CI brackets, CP brass chain with rubber plug, 40mm CP brass waste and 40mm CP{ brass trap with necessary cP brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required complete all as specified and directed.
Providing and fixing PVC low level flushing cistern 10 litre capacity white with manually controlled device ( handle lever ) conforming to IS : 7231, with all fittings and fixtures complete all as specified and directed.
Providing and fixing uplasticised PVC connection 15mm nominal bore x 30 cm length pipe with PTMT nuts, collar and bush of approved and colour complete all as specified and directed.
Providing and fixing uplasticised PVC connection 15mm nominal bore x 45 cm length pipe with PTMT nuts, collar and bush of approved and colour complete all as specified and directed.
Providing and fixing CP brass long nose bib cock 15mm nominal bore of approved quality conforming to IS standards and weighing not less 810 gms complete all as specified and directed.
Providing and fixing CP brass angle valves 15mm nominal bore for basin, mixer and geyser, urinal etc points of approved quality conforming to IS 8931 complete all as specified and directed.
Providing and fixing 8mm dia CP/ SS jet with flexible tube upto 1 metre long with SS trianguolar plate to Eureopean type WC of quality and make as approved complete all as specified and directed.
Providing and fixing 15mm nominal bore pillar taps cast copper alloy with capstan head of approved quality and design complete all as specified and directed.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead complete all as specified and directed.
Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete all as specified and directed.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangements of approved quality and colour 600mm long complete all as specified and directed.
Providing and fixing PTMT circular type 125mm nominal dia with 25mm waste hole grating of approved quality and colour complete all as specified and directed.
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materails with snap fittings of approved quality and colour , weighing not less than 105 gms complete all as specified and directed.
Providing and fixing PVC waste pipe flexible pipe 32mm / 40mm dia for sink or wash basin and urinal incluindg PVC waste fittings complete all as specified and directed.
Providing and fixing 100mm inlet and 100mm outlet sand cast iron S&S as IS-3989 trap of self cleansing design with screwed down or hinged grating with or without vent arm complete incluindg cost of cutting and making good the walls and floors complete all as specified and directed.
Dismantling CI or asbestos rain water pipe with fittigns and clamps including stacking the materials within 50 metres lead complete all as specified and directed for :- (i) 75 to 80mm dia pipe
(ii) 100 mm dia pipe
Providing and fixing 100mm dia sand cast iron S&S pipe as per IS : 1729 soil waste and vent pipes complete all as specified and directed.
Providing and fixing 75mm dia sand cast iron S&S pipe as per IS : 1729 soil waste and vent pipes complete all as specified and directed.
Dismantling old CI pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at the site lead upto 50 metre complete all as specified and directed for :- (i) 75mm diameter of CI pipe
(ii) 100 mm diameter of CI pipe
Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts 75mm dia sand cast iron S&S as per IS 1729 complete all as specified and directred.
Providing and fixing 75 x 75 x75mm sand cast iron S&S as per IS -1729 single equal plain invert branch of required degree complete all as specified and directed.
Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts 100mm dia sand cast iron S&S as per IS 1729 complete all as specified and directed.
Providing and fixing 100 x 100 x100mm sand cast iron S&S as per IS -1729 single equal plain invert branch of required degree complete all as specified and directed.
Providing and fixing 10mm thick Acid resistant tiles in flooring on a bed of 12mm thick mortar 1:4 ( 1 acid proof cement : 4 coarse sand) and joints filling with acid resisting cement as per IS:4457 complete all as specified and directed.
Providing and fixing 100mm dia sand cast iron S&S as per IS- 1729 cowls complete all as specified and directed.
Excavating post holes upto 0.10 cum, incluidng getting out the excavated soil, then returning the soil as deported in layers not exceeding 20cm in depth, including consolidating and deposited layer by ramming watering etc disposing of surplus excavated soil as directed with in a lead of 50m and lift upto 1.5m in all kind of soil complete all as specified and directed.
M&L plain cement concrete type C-2, 1:2:4 (40mm graded aggregate ) as in foundations, filling and mass concrete complete all as specified and directed.
Providing and fixing MS tube hand rail or approved size by welding etc to steel ladder, railing, balconey railing, staircase railing and similar works including applying priming coat of approved steel primer including taking out old complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size / shape , made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern finishing and sweeping extra sand complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 ( 1 cement , 3 coarse sand) including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5mm) includng making drainage opening wherever required including demolition of existing kerb stone complete all as specified and directed.
Disposal of building rubbish / malba/ similar unserviceable, dismantled or waste materials by mechanical means, incluidng loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer -in- charge beyond 50m initial lead for all leads including all lifts involved complete all as specified and directed.
M&L for RCC NP3 150 mm dia pipes laid on 150 mm thick bed, Types of bedding is 150 mm thick PCC Cradle PCC 1:4:8, depth 0.70 m to 1.65 m with excavation in any type of soil, including manholes/drop manholes of standard size made of brick masonry/RCC/Precast RCC with SFRC ventilating cover and frame includes all items and activities to execute and make sewer line functional complete all as specified and directed.
Providing and laying cement concrete 1:2:4 (1 cement:2 coarse sand zone-III) derived from natural sources: 6 graded stone aggregate 20mm nominal size derived from natural sources) including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete all as specified and directed.
Returning filling in trenches incl spreading,levelling , watering& well ramming in layers n.exc 25cm thick in soils complete all as specified and directed.
Taking down carefully old unserviceable aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
Taking down old unserviceable DBs including MCCBs/MCBs complete and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
Taking down old unserviceable sub main wiring of any type and size and making good the distrubed surfaces to match with existing surfaces complete all as specified and directed.
M&L Point wiring complete with 1.5 sqmm single core, PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 Volts grade conforming to IS 694 drawn through and including non metallic rigid PVC conduit 25mm dia medium grade and conduit accessories such as bends, tees, junction boxes etc concealed in walls duly chiselling/grooving as required except in beams, roof and including single core, PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 Volts grade conforming to IS 694 as earth continuity wire including modular switches 6A, modular GI flush boxes, modular cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators etc all as specified and directed for following:-
One light point controlled by one, one way modular switch 6 Amps
(b) One ceiling fan point /Exh fan point controlled by one, one way modular switch 6 Amps and regulator
(c) One bell point controlled by one modular bell push 6 Amps
M & L for Sub main wiring/ circuit wiring with 2 X 1.5 sq. mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawn through and including suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including One run of 1 x 1.5 sq mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed for 6 Amp socket outlet point on independent board complete all as specified and directed. Note:- Three runs of wiring and one run of PVC conduit shall be measured and paid as one unit length.
M & L for Sub main wiring/ circuit wiring with 2 X 2.5 sq. mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawn through and including suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including One run of 1 x 2.5 sq mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed for 16 Amp socket outlet point on independent board complete all as specified and directed. Note:- Three runs of wiring and one run of PVC conduit shall be measured and paid as one unit length.
S&F switch socket board comprising of 4 Nos modular switches 6 Amps and 5 pin 6 Amps modular socket outlet and one switch board recessed in wall complete with GI modular box, modular plate and cover including internal electric connection with copper cable complete all as specified and directed
Supply and fix LED light fitting 20 Watt, 6500K, 2000 Lumens surface/ceiling mounted batten fitting with polycarbonate body enviormental friendly with better asthetic finish for soft light duly wired upto terminal block complete all as specified and directed
S&F LED security light fittng 35/36 W , IP -66 protection 5700K colour temp ,made up of die cast aluminium housing with high power LED as lighting source and lens embeded PC lens having complete fixing with GI bracket made out of 40mm bore GI light grade 1.5 metre length bend to shape and fixed to pole /wall with necessary MS clamp and accessories and connecting electrically complete all as specifeid and directed.
Supply and fix Recess mounted full panel LED luminaire 36 watt fitting 2' x 2' with White powder coated housing & frame in CRCA sheet, High efficiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI>80, Colour temperature-5700K, IP20, 50000 burning hours as per L70 Criteria, Ambient temperature-0 to 50°C, Driver Efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM-3KV, Multistage isolated Constant current-Constant voltage operated driver with range 150-270V AC and Safety extra low voltage safe level<60V DC as per IEC Standard and connecting electrically complete all as specified and directed.
S&F High Bay light fittings 150 watts robust type, PDC housing suitable for ceiling suspended type of luminous efficacy not less than 150 lm/W complete color temp 5000K including fixing to the ceiling with necessary fastner /hook for hanging the lights and connecting with three core 2.5sqmm round copper cable from ceiling rose to the connector of the fitting complete all as specified and directed .
Dismantling of ceiling fan and painting the same with two or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, incl cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, re-installing the same as required complete all as specified and directed.
Supply and fix MCB SP 6-32 A, 230 V,10 KA, C curve type complete all as specified and directed.
Supply and fix MCB SP&N 40 A, 230 V,10 KA, C curve type complete all as specified and directed.
Supply and fix MCB TP&N 63 A, 415 V,10 KA, C curve type complete all as specified and directed.
S&F MCB Distribution board SP&N 2way 230V of sheet steel enclosure, IP 43 protection, double door fixed in recess flush with wall including MCB DP 32 Amps, 240 V "C" curve 10 KA complete all as specified and directed.
S&F Vertical type MCB Distribution board TPN 4 way (4 + 12) 415 V, 50Hz with sheet steel enclosure dust protected, epoxy powder coated, IP 43 protection, double door fixed in recess flush with wall including of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required complete all as specified and directed.
S&F MCB Distribution board SP&N 12 way, 230 V, epoxy powder coated with sheet steel enclosure, IP-43 protection, double door fixed flush to wall and suitable for universal mounting with 200 A copper bus bar, neutral bar, standard DIN rail, earth bar and top and bottom removable gland plates with Knockouts complete all as specified and directed.
S&F MCB Distribution board SP&N 08 way, 230 V, epoxy powder coated with sheet steel enclosure, IP-43 protection fixed double door flush to wall and suitable for universal mounting with 200 A copper bus bar, neutral bar, standard DIN rail, earth bar and top and bottom removable gland plates with Knockouts complete all as specified and directed.
S&F MCB Distribution board SP&N 6 way, 230 V, epoxy powder coated with sheet steel enclosure, IP-43 protection fixed, double door flush to wall and suitable for universal mounting with 200 A copper bus bar, neutral bar, standard DIN rail, earth bar and top and bottom removable gland plates with Knockouts complete all as specified and directed.
M&L for sub main wiring with 2 run of 1.5 sq mm single core copper conductor cable PVC insulated, sheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases/ grooves and making good the distrubed surfaces to match with existing surfaces including 1 run of 1.5 Sq mm single core copper conductor cable, PVC insulated, sheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed for high bay lights. Note:- 3 runs of 1.5 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit
All as per item No 160 above but submain wiring with 2 run of 4 sqmm and 1 run of 4 sqmm as earthwire complete all as specified and directed. Note:- 3 runs of 4 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit
All as per item No 160 above but submain wiring with 2 run of 6 sqmm and 1 run of 6 sqmm as earthwire complete all as specified and directed. Note:- 3 runs of 6 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit
All as per item No 160 above but submain wiring with 4 run of 6 sqmm and 2 run of 6 sqmm as earthwire complete all as specified and directed. Note:- 6 runs of 6 Sq.mm and 1 run of PVC conduits will be measured and paid as one unit
All as per item No 160 above but submain wiring with 4 run of 10 sqmm and 2 run of 10 sqmm as earthwire complete all as specified and directed. Note:- 6 runs of 10 Sq.mm and 1 run of PVC conduits will be measured and paid as one unit
All as per item No 160 above but submain wiring with 4 run of 16 sqmm and 2 run of 16 sqmm as earthwire complete all as specified and directed. Note:- 6 runs of 16 Sq.mm and 1 run of PVC conduits will be measured and paid as one unit
M & L for Earthing complete with galvanised iron earth plate electrode 600mm x 600 mm x 6 mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with the top edge of the plate not less than 1.5 mtr from ground level connected to and including GI Strip 25x5 mm of length up to 7.5 mtrs or testing point by means of GI bolts, nuts and washers etc and connected to earthing test point all as shown in DSR and testing on completion including excavation /earth work in any type of starta, PCC (1:3:6) type C1 earthing chamder, pre cast slab 50 mm thick in cement concrete (1 : 2 : 4 ) type B1 , cast iron frame, funnel with wire mesh, GI watering pipe of 20 mm bore medium grade and 40mm dia GI pipe light grade as protection to GI strip complete all as specified and directed.
M&L for GI strip 25 x 5 mm drawn through in and including GI pipe 40 mm dia light grade including connection with GI nut bolts, washers etc. laid in trenches, walls etc. complete all as specified and directed.
S&F sheet metal MCCB enclosure suitable for and including MCCB 100 Amps 4 Pole,16 KA, 415 volts, 50 Hz by providing electrical connections and fixed in recess flush to wall complete all as specified and directed.
S&F Motor with remote control suitable for existing Rolling shutter with automatic level stopping switch button, single phase and providing of power chain crank in absence of power with lifting capacity of motor suitable for 01 Metric Ton including electric connections by providing control wire and providing base frame and bracket for necessary fixing arrangement as required at site complete all as specified and directed.
S&F Air circulator wall mounting fan 600mm sweep, 230 Volts single phase oscillating ,oscillation up to 90º and metal body powder coated with all fixing arrangments to fix on wall, including provision of copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan including marking MES Number on fan motor complete all as specified and directed.
S&F Air circulator wall mounting fan 450mm sweep, 230 Volts single phase oscillating ,oscillation up to 90º and metal body powder coated with all fixing arrangments to fix on wall, including provision of copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan including marking MES Number on fan motor complete all as specified and directed.
S&F heavy duty exhaust fan 300mm sweep ,900RPM with aluminium louvers and shutters suitable for 240V single phase AC supply with all fixing arrangments to fix on wall, including provision of 3-way porcelain connector, copper bunched flexible three core 1.5sq.mm PVC insulated cable from connection point to fan complete all as specified and directed.
S&F suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 Amp modular switch, connections etc. complete all as specified and directed.
S&F suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 Amp modular socket outlet and 15/16 Amp modular switch, connections etc. as required complete all as specified and directed.
S&F Ceiling rose, 3 terminal, 5amps, 230V, AC Supply , ISI marked complete all as specified and directed.
S&F Call bell musical type 230V, AC Supply , ISI marked complete all as specified and directed.
S & Fix Single pole and neutral enclosure with two pin and earth plug and socket including MCB SP 20 A, 10 KA, C curve type complete all as specified and directed
Supply and fix ELCB 63Amps, 300mA, TP&N, 415 V, 50 Hz complete all as specified and directed
Making connection of GI, distribution branch with GI main of 50 mm dia by providing and fixing tee , including cutting and threading the pipe complete all as specified and directed.
Providing and fixing in replacment of GI pipes complete with GI fittings including trenching and refilling etc for 50 mm dia complete all as specified and directed.
Providing and fixing in replacment of GI pipes complete with GI fittings including trenching and refilling etc for 40 mm dia complete all as specified and directed.
Providing and fixing in replacment of GI pipes complete with GI fittings including trenching and refilling etc for 25mm dia complete all as specified and directed.
Providing and fixing in replacment of GI pipes complete with GI fittings including trenching and refilling etc for 15mm dia complete all as specified and directed.
Providing and fixing in replacment of gun metal gate valve CI wheel of approved quality of size 50mm dia bore screwed end complete all as specified and directed.
Providing and fixing in replacment of gun metal gate valve CI wheel of approved quality of size 25mm dia bore screwed end complete all as specified and directed.
M&L for Providing and fixing in replacment ball valve (brass ) of approved quality, High or low pressure , with plastic floats complete of 15 mm nominal bore complete all as specified and directed.
Excavation in trenches, not exceeding 1.5mm wide and not exceeding 1.5m in depth for laying of pipe line and getting out in any type of soil complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, install, testing and commissioning step down transformer 315 KVA, 11000/433 V (at no load) AC, Outdoor type, 4 wire, 3 phase, 50 Hz, core type copper wound, oil immersed, naturally cooled, Oil natural, air natural (ONAN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol. DYN-11 (Vector Group) with neutral brought out on secondary side (LV) and having tapping at +5% to -10% @ 2.5% HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree Centigrade in oil and 55 degree Centigrade in HV/LV coil winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree Centigrade. The transformer shall be of EEL-2 conforming to IS-1180 - 2014 Amendment No 1,2,3&4 after 29 Mar 2022 or with latest amendments and overload capacity of transformer as per IS - 2026 with latest amendments including suitable PCC plinth & foundation for mounting the transformer as per manufacturer recommendation and shall comprise of the following :-
(a) One cable box on HT side (Primary side) consisting of 3 Nos porcelain bushing with copper rods, complete with nuts and washers with two Nos cable glands suitable for reception/ taking out of XLPE insulated heavy duty armoured cables including gland, joint and jointing materials complete
(b) One cable box on LT side (Secondary side) consisting of 4 Nos porcelain bushing with copper rods, complete with nuts and washers with two Nos cable glands suitable for reception/ taking out of PVC/XLPE insulated heavy duty armoured LTcables including gland, joint and jointing materials complete. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One No 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree Centigrade with metal guard having maximum perimeter reading temparature indicator with resisting device for transformer. (h) Two earthing terminals on tank cover to facilitate fixing of 32X6 mm galvanized iron earth strip for earthing of neutral and body. (j) Rating plate and terminal marking plate. (k) Oil level guage. (l) Oil drain filler valve. (m) Lifting lugs. (n) Oil filling hole with cap/plug with connecting plate complete.
(o) Air release valve plug. (p) Four plain solid cast steel detachable rollers. (q) Extra bushing for neutral, outside the LT cable box for providing independent earthing for neutral. (r) First filling of new and unused transformer oil IS-335/93 (fourth revision) marked filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (s) One danger notice board having conventional danger sign of skull with bones in painted in red colour. Note: (i)Certification of dielectric strength shall be submitted by the contractor after filling the oil.
Supply, install, testing and commissioning of indoor type HT 11 KV, Vacuum Circuit Breaker INCOMER CUM OUTGOING panel with copper bus bar drawout type, horizontal isolation type VCB of capacity 630 Amps rated current, 3 Phase, 50 Hz as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with 2.0 mm thick CRCA sheet and shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25KA/1 Sec : (i) Mechanical Life- 30,000 Hours (ii) Rated current - 10,000 Hours (iii) Rated short circuit Current- 100 Nos All the components/ accessories such as PT/CT/Relays / Meters etc. shall be as per VCB manufacturers specified make only to be provided. (i) Rated voltage level / PF withstand voltage/ Impulse level: 12 KV/ 28 KV / 75 kvp (ii) Contineous current rating: minimum 630 Amp (iii) Short circuit withstand current: minimum 25 KA for 3 Sec. IAC AFLR LSC-2B PM classification as per IEC62271-200 (iv) One No. minimum 630 Amps horizontal draw out type Vacuum Circuit Breaker in 12 kv metal clad floor mounting panel complete wth following:-
(a) Manually & Motor operated ( 230 V, AC, 50 Hz ) spring charged type, manually and electrically open ( electrical - 110 VDC) operating type, incorporating mechanical as well as electrical ON/OFF indication " OFF" push button, test/ service position limit switches, with minimum 6 NO + 6NC breaker auxilary contacts in service position. (b) Current transformer Cast resin type 11 KV, 200 - 100 / 55A, Core1: class 1, 15 VA for 3 phase, core2: 5P10, 15VA burden and conforming to IS: 2705 with latest amendments. (c) pOTENTIAL TRANSFORMER CAST RESIN TYPE 11 kv/ 110v/ 50VA/ CI 1.0, CI 3P and HT Fuse at the primary end and 04 pole MCB at the secondary end of the PT ( Conforming IS: 3156 specifications). (A) Protection arrangements for the breaker shall comprise of the following: i) E/F, O/C, S/C, TCS with MODBUS protocol- Numerical type of OEM specifications. ii) Relay should have mimic display. iii) Complete with Master Trip / Anti pumping relay.
Supply laying and testing HT cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) earthed grade with stranded aluminium conductor 11000 volts grade of size 95 sqmm 3 core conforming to IS-7098 part-II complete all as specified and directed. Note:- Excavation, earthwork, sand cushioning, cable covers, pipe for cable protection to be measured and paid seperately.
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 200 Amps complete all as specified and directed.
Supplying and making indoor cable end jointing with heat shrinkable jointing kit complete with all accessories including lugs, suitable for 95 sqmm of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
Supplying and making outdoor cable end jointing with heat shrinkable jointing kit complete with all accessories including lugs, suitable for 95 sqmm of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS-7098 part-I complete all as specified and directed of following sizes :- Note: Excavation, earthwork, sand cushioning, cable covers, pipe for cable protection to be measured and paid seperately.
400 sq mm 3½core
300 sq mm 3½ core
240 sq mm 3½ core
70 sq mm 3½ core
50 sq mm 3½core
35 sq mm 3½ core
25 sq mm 3½ core
16 sq mm 4 core
(a) ACB 4 pole ,800 Amps rating manual draw out type having short curcuit breaking capacity of 50KA at 415 volts,(Ics =100% Icu), confirming to IS/IEC 60947-2&3, microprocessor base ET trip systems with thermal memory, with fully rated neutral with inbuilt protections, equipped with overload, short circuit, instantaneous and earth fault. Protection, vertical termination, 01 No electrical fault indicator contacts 01 No. 01 No auxilary contact block (OF) with 02 Nos contacts with safety shutters onhasas and door sealing frame complete with all accessories as specified and directed-01No. (b) MCCB 4 pole 415V,400 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 36 KA adjustable overload min 70-100%-02 Nos. (c) MCCB 4 pole 415V,320 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 36 KA adjustable overload min 70-100% -01 No
(d) MCCB 4 pole 415V,200 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 25 KA adjustable overload min 70-100%-01 No. (e) Panel mounted type digital multifunctional energy meter A,V,,KW,PF,CT operated, LT 3 phase, 4 wire including CT ratio 400/5-01 Nos. (f) LED indiating lamps set RYB-01 Set. (g) On load change over switch 4 pole 500 Amps open execution type-01 No Note :- (i) The design of panel should be as per switch gear type test certificate report of OEM should be submitted, panel should also be tested for internal as per IEC 61641. (ii) Contracor shall submit the technical specifications, constructional drawing, make and model of switch gear, accessories for approval of GE before manufacturing of panel.
Note :- (ii) Contracor shall submit the technical specifications, constructional drawing, make and model of switch gear, accessories for approval of GE before manufacturing of panel. (a) MCCB 4 pole 415V,400 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 36 KA adjustable overload min 70-100% - 01 No (b) MCCB 4 pole 415V,320 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 36 KA adjustable overload min 70-100% -01 No (c) MCCB 4 pole 415V,250 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 25 KA adjustable overload min 70-100%-02 Nos (d) Panel mounted type digital multifunctional energy meter A,V,,KW,PF,CT operated, LT 3 phase, 4 wire including CT ratio 400/5-01 Nos (e) LED indiating lamps set RYB-01 Set
(a) MCCB 4 pole 415V,320 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 36 KA adjustable overload min 70-100% -01 No (b) MCCB 4 pole 415V,250 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 25 KA adjustable overload min 70-100%-01 No (c) MCCB 4 pole 415V,100 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 16 KA adjustable overload min 70-100% -02 Nos (d) MCCB 4 pole 415V,63 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 16 KA adjustable overload min 70-100% -02 Nos (e) MCCB 4 pole 415V,40 Amps,50 Hz fixed type 16 KA - 02 Nos (f) Panel mounted type digital multifunctional energy meter A,V,,KW,PF,CT operated, LT 3 phase, 4 wire including CT ratio 400/5-01 Nos (g) LED indiating lamps set RYB-01 Set
(a) MCCB 4 pole 415V,400 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 36 KA adjustable overload min 70-100% -01 No (b) MCCB 4 pole 415V,100 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 16 KA adjustable overload min 70-100% -02 Nos (c) MCCB 4 pole 415V,63 Amps,50 Hz thermal magnetic release and Ics=100%Icu with rupturing capacity 16 KA adjustable overload min 70-100% -04 Nos (d) MCCB 4 pole 415V,40 Amps,50 Hz fixed type 16 KA - 07 Nos (e) Panel mounted type digital multifunctional energy meter A,V,,KW,PF,CT operated, LT 3 phase, 4 wire including CT ratio 400/5-01 Nos (f) LED indiating lamps set RYB-01 Set
Supply, install, testing and commissioning Servo Voltage Stabilizer 315 KVA capacity for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 360 V to 465 V with output voltage stabilized at 415± 1% with accuracy and speed of correction 8 Volts with accuracy per second with following specifications:- Capacity :- 315 KVA-3 Phase Input working range :- 360-465 V Input tripping range :- 340-485 V Output voltage :- 415 V± 1% Protections:- Low and high voltage cut off, over load cut off, short circuit protection. Stabilizer with super enamelled copper and with first filling of oil duly testedand shall provide indicators for input on, output on and output cut off including LCD metering and stabilizer shall conforming to relevant IS standards.
M & L for sand filLing in cable trenches as cushioning of cables upto 23cm and punned down to 18cm complete all as specified and directed. Note :- Punned thickness of the sand will be measured and paid
Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 1 with flat, size 300mm x 180mm x 40mm complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Supply and fiximg GI tubing light garde 100 mm bore in trenches/road/plinth, fixing alongwith pole/wall for protection of cable complete all as specified and directed.
Supply and fixing GI tubing light garde 80 mm bore in trenches/road/plinth, fixing alongwith pole/wall for protection of cable complete all as specified and directed.
Supply and fixing GI tubing light garde 50 mm bore in trenches/road/plinth, fixing alongwith pole/wall for protection of cable complete all as specified and directed.
M&L for fixing of cable route indicator of size 2'x.5' duly embedded HT cable over it, laying/fixing on every 50 mtr span over the route of HT cable vertically for clear indication of cable route by providing necessary PCC foundation /copping complete all as specified and directed
Supply installing, testing and commissioning of 2 TR capacity Split type air conditioner unit (Inverter type) BEE five star rated complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor unit with powder coated MS stand/PCC base and fixing of indoor unit on wall, providing and making interconnection, including refrigerant piping with nitrile rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 mtrs, power cabling (max 3.0 mtrs from isolator/enclosure) to units, first charging non CFC/non HCFC refrigerant gas including cord less remote, PVC drain pipe of 25mm dia for connecting drain lines from indoor unit to maximum of 3.0 mtrs to nearest drain points complete all as specified and as directed.
Supply installing, testing and commissioning of 1.5 TR capacity Split type air conditioner unit (Inverter type) BEE five star rated complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor unit with powder coated MS stand/PCC base and fixing of indoor unit on wall, providing and making interconnection, including refrigerant piping with nitrile rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 mtrs, power cabling (max 3.0 mtrs from isolator/enclosure) to units, first charging non CFC/non HCFC refrigerant gas including cord less remote, PVC drain pipe of 25mm dia for connecting drain lines from indoor unit to maximum of 3.0 mtrs to nearest drain points complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5KVA complete all as specified and directed.
INDGUARD ENGINEERS
M/S GDR CONSTRUCTIONS
M/s Amit Associates
Shree Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .