Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC L1 for M/s RANDHIR AND COMPANY | |
| 2 | L2₹48.2 L+₹3.2 L (7.07%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED | |
| 3 | L3₹49.9 L+₹4.9 L (11.0%)Rejected-Finance H NO 13149 STREET NO 3 SHIV COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance L3 FOR REJECTED | |
| 4 | L4₹51.7 L+₹6.7 L (14.9%)Rejected-Finance | L4 | Rejected-Finance L4 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹87,600
Closing Date
22 Jul 2021, 6:00 pmClosed
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO CWE SGNR 96 OF 2020-21 SPECIAL REPAIRS TO BUILDING NO. OP-08 (OFFICERS MARRIED ACCOMMODATION) AT MILITARY STATION ABOHAR (5TH CALL)
2021_MES_428158_5
CA NO. CWE SGNR - 96 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE ABOHAR
CLASS-D
CATEGORY-a(i)
10 documents required · 10 mandatory
₹500
₹87,600
Yes
10 Aug 2021
1 Jul 2021
24 Jul 2021
1 Jul 2021
22 Jul 2021
8 Jul 2021
Amount
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work complete all as specified and directed by Engineer-in-Charge.
Demolition of mud in roofs any thickness incl plastering and leeping complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick tiles or terracing tiles in roofs single layer complete all as specified and directed by Engineer-in-Charge.
M & L for 50mm thick cement concrete type C2 1:3:6 (40mm graded aggregate) as in plinth protection , surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-0 as required (superficial area n. exc 150 sq cm) complete all as specified and directed by Engineer-in-Charge.
M & L 50 mm thick Cement Conrete1:2:4 type B–1 using 20mm graded stone aggregates flooring finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Excavation trenches hard and dence soil n exc 1.50 wide and n exc 1.50 m depth for foundation etc in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading leveling, watering and well ramming in layers n exc 25 mm thick soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material exceeding 200m and n exc 250 m and deposited where directed at a level not exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L Providing cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 12 here-in-before but for 5 mm dia and over up to and including 8 mm dia as in stirrups complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in as in foundations, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Columns, pillars, piers, posts & struts etc. complete all as specified and directed by Engineer-in-Charge. Note : Form work & reinforcement measured separately
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5 metre span complete all as specified and directed by Engineer-in-Charge. Note : Form work & reinforcement measured separately
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. Note : Form work & reinforcement measured separately
M&L for Form work to sides of concrete fdns, footings bases of columns and plinth beams and similar works rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs, such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick (Horizontal & sloping) fair finished surfaces complete all as specified and directed by Engineer-in-Charge. Note- Steel props to be use
M&L for From work to edges of concrete flates treads breaks in floors, window cill concrete railing, opening in convert valley floor and roof exc 10 cm but n.exc 20 cm wide and sides RCC/PCC band in walls complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides of pillars, posts, struts, piers columns & stanchions : rough finished surface of flat concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer-in-Charge.
S & F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 25 here-in-before but for except bricks complete all as specified and directed by Engineer-in-Charge.
M & L for brick work in half brick thick wall using fly ash bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for providing precast cement concrete louvers and jallies 40mm thick type B0 1:2:4(12.5 mm graded aggregate) as in Jafri wall set in cement mortar 1:4 including all mouldings but excluding frame complete all as specified and directed by Engineer-in-Charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices complete all as specified and directed by Engineer-in-Charge.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick CM (1:4) as in backing coat complete all as specified and directed by Engineer-in-Charge.
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 31 here-in-before but for as in skirting over 10 mm rendering in CM (1:4). as in backing coat complete all as specified and directed by Engineer-in-Charge.
M&L Granite 18 - 20mm thick(of any type) works (table rubbed and polished) in step, window cills, cooking platforms and the like in cement mortar (1:4), 20 mm thick including pointing in white cement (1:2) using marble dust with admixture of pigments to match incl 15mm thick screed bed in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as specified and directed by Engineer-in-Charge.
S&F in repair powder coated aluminium sliding window three track with frame & two glass shutters using 4 mm thick glass tinted modi guard and ond shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61mm using aluminium powder coated section aluminium cleat, PVC track, bearing, handle lock rubber beading etc complete fittings as approved. Note :- Size of aluminum section shall be under – (i) Three track top and vertical –jindal main-2010 section No 20621 or equivalent as approved by GE. (ii) Three track bottom-Jindal main-2010 section No 20620 or equivalent as approved by GE. (iii) Shutter vertical section-Jindal main-2010 section 20604 or equivalent as approved by GE. (iv) Shutter top and bottom –Jindal main – 2010 section 20604 or equivalent as approved by GE. (v) Shutter vertical middle (interlock) – Jindal main – 2010 section 20605 or equivalent as approved by GE.
S&F for powder quoted Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder quoted aluminum window and ventilator shutter side hung type without sash, aluminium sections weighing glazing clips, rubber packing anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150 mm long (1 No) hinges type B-21 100 mm long (2 No) suitable handle (1 No) complete all as specified.
S&F aluminum anodised grill diamond shape 100mm x100mm aperture of 6mm dia round bars including necessary joining cleats, clips anodised aluminium snap beading screws complete all as specified as directed by Engineer-in-Charge
M & L Washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per sqm, top layer 15 mm cement plaster 1:1/2:2 (1 cement : ½ coarse sand : 2 stone chipping 10 mm normal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to be expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately).
Forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden batterns, nailed to the under layer including removal of wooden batterns, repair to the edges of panels and finishing the groove complete as per specification and direction of the Engineer-in-Charge
S & F figured glass 3 mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pan complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down shutters and easining of doors and replacement of Iron mangory whichever reqd and refixing in same opening but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge.
Taking down shutters but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge.
S&F "fiberways" brand fiber glass reinforced plastic (FRP) Door frame of three legged of cross section 90x45 mm size single nrebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame moulded with two resistant grade unsatratedpolyster plain and chapped mat d or frame laminate shall be 2mm thick and shall be filled with subbish wooden block in all two three legs . the frame shall be covered with fibre glass from all side. MS stay shall be provided at the bottem to steady the frame complete all as specified and directed by Engineer-in-Charge.
S&F "fiberways" brand 30mm thick glass fiber reinforced plastic (FRP) panelled door shutter of required colour are approver brand and manufacture made with fire resistance grade unsatratedpolyster plain moulded to 3mm thick fiber laminate for foming hollow ralliuded styles with wooden frame and suitable blocks of sessoned wood inside at required place for fixing of fiber-cast monolithitically with 5mm thick FRB laminated for panels and conforming to IS-4858-2000 complete all as specified and directed by Engineer-in-Charge.
S & F PVC butt hinges, medium weight 100 mm size fixed with steel screw complete all as specified and directed by Engineer-in-Charge.
S & F tower bolt 150 mm of PTMT complete all as specified and directed by Engineer-in-Charge.
S & F door handle D type 150 mm of PTMT complete all as specified and directed by Engineer-in-Charge.
S&F Floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
S & F Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S & F in Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
S & F pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 105X60mm complete all as specified and directed by Engineer-in-Charge.
S & F pressed steel door frames size of 125X60mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete 1:3:6 type C-1 for filling of pressed steel frame and hold fast blocks etc complete all as specified and directed by Engineer-in-Charge.
S & F mild steel butt hinges, medium weight 100 mm size fixed with steel screw complete all as specified and directed by Engineer-in-Charge.
S & F aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long complete all as specified and directed by Engineer-in-Charge.
S & F aluminium bow handle stove enamelled black, 150 mm long complete all as specified and directed by Engineer-in-Charge.
S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm complete all as specified and directed by Engineer-in-Charge.
S & F mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified and directed by Engineer-in-Charge.
S & F small fittings such as door stops and like, including all necessary labours articles not exceeding 200 Cucm each of 2nd class hard wood complete all as specified and directed by Engineer-in-Charge.
S&F hasp & staple safety type aluminium anodised with hinges pins incl bolt to hinge plate fixed with screw 125mm complete all as specified and directed by Engineer-in-Charge.
S&F peg set of stainless steel solid body of 125mm to 175 mm having 6 Nos hooks fixed with brass chromium plated screws complete all as specified and directed by Engineer-in-Charge.
S& F in repairs Drapory curtain rod of 25 mm dia decorative type with brass coated ends caps includinf fixing arragements like brackets,stops,rollers etc. complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engineer-in-Charge.
S & F framed work such as grills, cooler stand ,grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S & F exc 12 mm dia & n. exc 20 mm dia of neck mild steel bolts purpose made with hesagonal or square head one and end and screwed to other, or screwed to both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 30 cm long complete all as specified and directed by Engineer-in-Charge.
M&L plates (plain or chequered) channels , square cut or notched (ordinary and counter sunk) forming holes , without any attachment Fe-415 -W (Gde -e -250) quality -B complete all as specified and directed by Engineer-in-Charge.
S&F sink with drainage board made of Stainless Steel 1mm thick kitchen with plug washer and waste including bedding in cement mortar to dwarf wall including fixing contilever brackets connecting union to pipe over all size 915x460 mm bowl of size 410 x 330 x 160 mm fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F 2nd class hard wood plain solid, straight chowkats and frames wrought,frame rebated on the solid,rounded or chamfered,put together with glue pinned at joints,supplied and fix complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for 18/19 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination on both side fixed with screws to timber work complete all as specified and directed by Engineer-in-Charge.
M & L 15mm thick rendering in Cement Mortar 1:6 on the Top of roof surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
S & F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane including hacking out old broken glass (any thickness,size,quality or description) complete all as specified and directed by Engineer-in-Charge.
S & F 100mm extuded,brass handles,fabricated type polished for cabinet shutters complete complete all as specified and directed by Engineer-in-Charge.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flaps (when open 30 mm) complete all as specified and directed by Engineer-in-Charge.
S&F Magnetic cather fixed with nut,screw washer complete including letting in and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for water proofing treatment for RCC sunken slab(not exceeding 45cm depth of sunken) as specified below and complete all as specified and directed by Engineer-in-Charge.- (a) 15mm plaster in cm 1:3 with WPC on raised vertical surface (b) cleaning the surface with wire bruse/coir brush, removing lose material like dust particals, dirt etc. (c) Creating fillet covering of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply frist coat of two component modified polymer coating on the horizontal and vertical surface (e) provision of glass fiber mesh of 2x2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) laying concrete 1:4:8 over the coating as per requirement (h) joining the sanitery pipes with the waterproofing tape having bridging ability of more then 1.5mm (j) filling the gap between the wall opening and sanitery pipe with non shrink cementatious grout (k) Complete the treatment to be carried out by authorised applicatir of waterproofing manufacturer. Make:- Dr. Fixit/ Fosroc/BASF/STP . Note: (i) the treatment shall be carried out as per the manufacturer instruction and as directed by the Eng in Charge. (ii) The plan area of floor shall be considerd for payment. (iii) Cost of WPC @ 3% by wt of cement is included in the unit rate of item.
Providing 100mm cement concrete Type E-2, 1:5:10 (40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel plate rack of size 750mm x 600mm, made out of 1mm thick stainless steel of sheet of 1st quality complete all as specified and directed by Engineer-in-Charge. Make:Anupam international model No KPR-311 or Equivalent make and model approved by GE.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excludin fixing bolts, flushing cistern and flush pipe) with PVC sheet cover & 'P' OR 'S' trap complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC Straight jet spray with 1.0 m tube for water closet wash down(pedestal pattern) complete all as specified and directed by Engineer-in-Charge.
S&F health faucet 2 in 1 with 1.5 mtr tube and hook of same complete all as specified and directed by Engineer-in-Charge. Make: Jaquar ALD CHR-583/Hindware-505233/Parryware or as approved by GE.
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Wall hung vitrous china wash hand basin with full pedestal size 550 x 400 mm screwed shank fly nut flange end including cutting for and pinning of hole including 32 mm dia chromium plated waste coupling and bottle trap complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore bib taps,chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, secrewed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15mm bore stop cock one way fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15mm bore stop valve, cast copper alloy fancy type chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Sink mixer with swinging spout(wall mounted model)Chromium plated brass with connection and nut complete all as specified and directed by Engineer-in-Charge.
S&F brass chromium plated wall mixer with Provision for overhead shower with 140 mm long bend pipe and flange for mixing hot& cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F PVC bathroom cabinet mirror 450 x 350 mm complete all as specified and directed by Engineer-in-Charge.
S&F Rainfall shower round shape multiflow cleaning system complete all as specified and directed by Engineer-in-Charge.
S&F Wall mounted shower arm casted light body Square shape with flange complete all as specified and directed by Engineer-in-Charge.
S&F Towel Bracket chromium plated brass 61cm size complete all as specified and directed by Engineer-in-Charge.
S&F Towel ring round with round flange complete all as specified and directed by Engineer-in-Charge.
S&F Toilet paper holder fix with chromium plated brass screw and wooden/ plastic cleats complete all as specified and directed by Engineer-in-Charge.
S&F Acrylic shelf size 46 cmx13 cm complete all as specified and directed by Engineer-in-Charge.
S&F Corner glass shelf (with bracket) complete all as specified and directed by Engineer-in-Charge.
S & F soap dish fixed as chromium plated complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing 15mm bore and connections complete all as specified and directed by Engineer-in-Charge.
Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required complete all as specified and directed by Engineer-in-Charge. Note : Serviceable galvanised tubes retrieved from respective items shall be laid under these items
S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing 20mm bore and connections complete all as specified and directed by Engineer-in-Charge.
Fixing only tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required complete all as specified and directed by Engineer-in-Charge. Note : Serviceable galvanised tubes retrieved from respective items shall be laid under these items
S & F 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks of 1000 ltrs and removing to store complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks of 500 ltrs and removing to store complete all as specified and directed by Engineer-in-Charge.
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres complete all as specified and directed by Engineer-in-Charge.
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres complete all as specified and directed by Engineer-in-Charge.
M&L Ball valves PTMT 20mm, with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe (Minimum weight 20mm - 210 Grams) complete all as specified and directed by Engineer-in-Charge.
S & F in 15mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC socketed SWR pipe with rubber ring joints 110mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC socketed SWR pipe with rubber ring joints 75mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC socketed SWR pipe with rubber ring joints 110mm dia laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 117 here-in-before but for 75mm bore complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC (SWR) junction single,(single T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) junction single,(single T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) junction double,(double T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S & F Grating doom 125 mm dia with waste hole of PTMT ( Min wt 40 gm ) complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
M & L rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L rendering 15mm thick on fair faces of brick work in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Providing & applying Rising damp proof coating system with single component ready to use damp-proof coating Roff Hydampcomplete all as specified and directed by Engineer-in-Charge. 1.SURFACE PREPARATION:Thoroughly brush and clean all laitance,loose particles such as dirt,grease,mortar droppings,release agents,efflorescence,bird droppings etc. all large voids or hollow portions must be removed and replastered.Non-moving cracks having width upto 5 mm must be filled with polymer based crack filler. 2.APPLICATION: Apply the first coat of Hydamp with paintbrush directly on the prepared surfaces.Allow to dry for a minimum 2-3 hrs.Apply one part of Roff Hydamp and 2 parts of OPC white cement and make the putty,apply putty on the entire surface area.Allow it to dry for atleast 3-4 hours.Apply the final coat of Roff Hydamp on the entire surface.
M&L three coat of white wash on ceiling including necessary preparation complete all as specified and directed by Engineer-in-Charge.
M&L for two coat of white wash on ceiling old surface including necessary preparation complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered and unplastered surfaces of wall by applying two coats of interior grade wall putty( 1mm thick of each coat) and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of oil bound distemper over one coat of cement primer including complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces of wall by complete removing old treatment and applying two coats of interior grade wall putty( 1mm thick of each coat) and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of oil bound distemper over one coat of cement primer including complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered and unplastered surfaces of wall by applying two coats of interior grade wall putty( 1mm thick of each coat) manually and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of weather coat emulsion over one coat of primer manually complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of Old plastered external surfaces of wall by complete removing old treatment and applying two coats of interior grade wall putty( 1mm thick of each coat) manually and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of weather coat emulsion over one coat of primer including complete all as specified and directed by Engineer-in-Charge.
M&L for preperation of old wooden surface and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M & L providing two coats of synthetic enamel paint over new wooden surface including preparation of surface with primer complete all as specified and directed by Engineer-in-Charge.
M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer-in-Charge.
S & F steel work in rectanguler/square trusses incl spel shaped washer etc complete using ERW or incl butt welded tubes confirming to IS 1161-1979 grade ST-240 with one coat of sink chromate primer paint including preparation of surface complete all as specified and directed by Engineer-in-Charge.
S&F 50mm thick PUF panel made of Puf insulation in core having density 40+2 Kg/Cum sandwiched betweeen two numbers of polyster coated galvalume steel sheet.these sheets shall be made out of 0.50mm thick (TCT) High tensile steel having min yield strength of 550 Mpa confirm to AZ 150 of AS-1397 wityh hot dip metalic coating of 55% ZN alloy having total coating mass of minimum 150 gms/sqm inclusive of bothside. the material shall be coated with polyster coating paint system of 20 micron over primer of 5 micron (exposed side) & alkyd back coat of 5 micron over primer coat of 5 microns.the material shall be supplied as per drawing (approved by GE),colour and as per instruction complete all as specified and directed by Engineer-in-Charge.
S&F powder coated GI, E-grid suspended false ceiling grid system 600mmx600mm with main runner 39x29.7x0.8mm, cross tee 39x27.7x0.80mm, and wall angle 22.20 x 22.20 x 0.65mm, ceiling suspended with 4mm dia GI wire hanger fixed with steel dash fastener or frame purlin of the roof with butterfly clips, hold down clips etc. main runner, cross tee, wall angle, of MS galvanised (PPP COS) complete all as specified and directed by Engineer-in-Charge.
S&F, 7mm - 8 mm thick exposed metal frame celing with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmx600mm grid all as per manufacturer's instructions finish, fixed to aluminium/ CGI frame work with hold down clips in false ceiling complete all as specified and directed by Engineer-in-Charge.
M& L for Pre painted gavalume zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverings/cladding to wall,fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mm average thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts complete all as specified and directed by Engineer-in-Charge.
S & F structural steel work rolled mild steel joist, channel,angle,or Tee sections, fixed independently conforming complete all as specified and directed by Engineer-in-Charge.
S&F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt complete all as specified and directed by Engineer-in-Charge.
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M& L PCC 1:2:4 type B1, using 20 mm graded aggregates as in bed blocks ,coping, hold fast blocks etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully any type point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (Except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed by Engineer-in-Charge.
M&L point wiring (CONCEALED) for using 1.5 sqmm nominal cross sectional area copper conductor mutimultistranded ,PVC insulated unsheathed , FRLS cables in and including using PVC conduits not less than 20 mm dia and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multi-multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS and making good all disturbed work to match the existing for One light/fan point controlled by one 5 Amps one way switch and all as specified and brass screws, washers etc. complete all as specified and directed by Engineer-in-Charge.
All as per Item No.153 here in before but for One three pins 5 Amps switch socket outlet point on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 153 here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 153 here in before but for One light point controlled by two 2-way switches of 5 amps complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 153 here in before but for One bell point controlled by one bell push complete all as specified and directed by Engineer-in-Charge.
All as per item No 153 here in before but for 15 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 153 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly using color code as per IS and all as specified with copper lugs/timbles inserted in existing MS boards/boxes complete heavy duty for housing switches, , regulators, bell push etc, and making good all disturbed work to match the existing for One light / fan point controlled by one way piano switch 5 Amp. complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 160 here in before but for One three pins 5 Amps switch socket outlet point on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 160 here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per Item No.160 here in before but for One light point controlled by two 2-way switches of 5 amps complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 160 here in before but for One bell point controlled byh one bell push complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 160 here in before but for 15 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
S & F switch piano one way 5/6 amps 240 volts complete all as specified and directed by Engineer-in-Charge.
S & F Bell push AC, 50 Hz, 230 Volts, 5 amps complete all as specified and directed by Engineer-in-Charge.
S & F Bell ding dong AC, 230 Volts, Single pole complete all as specified and directed by Engineer-in-Charge.
S & F socket 5 in 1, 5 amps flush type complete all as specified and directed by Engineer-in-Charge.
S & F socket 5 in 1, 5/16 amps flush type complete all as specified and directed by Engineer-in-Charge.
S & F switch piano flush type 5 amps but 2 way type complete all as specified and directed by Engineer-in-Charge.
M & L lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including provision of 12 Watt LED lamp complete all as specified and directed by Engineer-in-Charge.
M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete all as specified and directed by Engineer-in-Charge.
S & F Modular Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engineer-in-Charge.
S & F Modular Bell, AC, 230 volts, single pole complete all as specified and directed by Engineer-in-Charge.
S & F modular fan regulator, step type, 120 watts, W-2 module complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring with Television co-axial cable in and including concealed PVC conduit (25 mm dia) and conduit accessories and metal flush box of one module with cover fixed with screw and cap washers for Television ponint and making good all disturbed work to match the existing complete all as specified and directed by Engineer-in-Charge.
M&L for modular type TV socket complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring with Telephone cables in and including concealed PVC conduit (20 mm dia) and conduit accessories and metal flush box of one module with cover fixed with screw and cap washers for Telephone point and making good all disturbed work to match the existing complete all as specified and directed by Engineer-in-Charge.
M&L for modular type Telephone socket complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring comprising single core, 2 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade draw in existing concealed conduit OR appropriate dia. PVC conduits and conduit fittings not less than 25 mm dia complete, including provision of 1 x 10 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete including taking down old UNSV sub main complete all as specified and directed by Engineer-in-Charge. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
All as per Srl item No 181 here in before but for 2 Runs of 6 sqmm nominal cross section and including provision of 1X6 sqmm nominal cross sectional area for earth wire complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 181 here in before but for 2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed by Engineer-in-Charge.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed by Engineer-in-Charge.
M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
S & F LED street light luminaitres 15 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engineer-in-Charge.
M&L for LED building street light luminaire of capacity 20 Watt with pressure die-cast housing with individual LEDs as light source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK 07 complete all as specified and directed by Engineer-in-Charge.
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 12 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 189 here in before but for SPN 8 ways, Double door type complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 189 here in before but for SPN 4 ways, Double door type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified and directed by Engineer-in-Charge.
Dismantling of existing unserviceable MCCB distribution board and S&F in repairs to sheet metal enclosure Distribution panel size 150cm X 100 CM X 15 CM having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, complete fitted with aluminum busbar 200 Amps with color code sleeves and provision 7 compartments for accommodating 4 No meters, stair case circuit, bus bar chamber and space for MCCB. And duly painting and connections in all respects complete all as specified and directed by Engineer-in-Charge.
Supplied and fixed Miniature circuit breaker (MCB), single pole, 240 Volts, of 6-32 amps current rating and 10 KA breaking capacity, B' series type complete all as specified and directed by Engineer-in-Charge.
Supplied and fixed Isolator, Double pole, 240 Volts, of 32 amps current rating complete all as specified and directed by Engineer-in-Charge.
Supplied and fixed Isolator, Double pole, 240 Volts, of 40 amps current rating complete all as specified and directed by Engineer-in-Charge.
Supplied and fixed Isolator, Double pole, 240 Volts, of 63 amps current rating complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all as specified and directed by Engineer-in-Charge. Note : GI wire upto 7.5m including testing consider in this item
Sand filling under flooors or in foundation including and consolidation as as specified and directed at site complete all as specified and directed by Engineer-in-Charge.
M & L brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 50 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes including provision of cable glands to both ends of connection point complete all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed by Engineer-in-Charge.
S & F GI tube light grade galvanised of size 40 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed by Engineer-in-Charge.
S & F BLDC (brushless direct current) Motor Ceiling fan 1200 mm sweep 5 star rating , single phase 240 volts, power consumption 26 Watt to 32 Watt on turbo mode with remote control, 220 CUM/Min. single phase, 50Hz. 240 volts warranty 2 years on product complete and accessories complete all as specified and directed by Engineer-in-Charge. Make: Atomberg Gorilla/Havells Efficiencia Neo/Crompton/ White or equvalent of CG/Luminous/Orient”
Geyser storage type, electric driven of capacity 25 Ltrs 5 star rating, with 8 bar pressure with standing ,rust proof, rust proof fire retardant cable adj thermostat anti corrosion protective device inner tank mild steel with glass lined coating including PVC connections and grouting of bolts with nut of suitable size including cement work for make good the disturbed surface complete all as specified and directed by Engineer-in-Charge. Make:: Bajaj cat No Caldia or equivalent in CG, Havells,
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water complete all as specified and directed by Engineer-in-Charge.
S&F for copper (CP) hot water pipe for Geyser, connection with check nut and washer complete all as specified and directed by Engineer-in-Charge.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCCB TPN/TP 100 Amps 415 Volts of braking capacity 36 KA of 3 pole confirming to (Adjustable Thermal and Magnetic Release Setting with short circuit settings) complete taking down old unserviceable one and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed by Engineer-in-Charge.
All as per Ser Item No 210 here-in-before but for 63 Amps with braking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of switch piano 15 Amps complete all as specified and directed by Engineer-in-Charge. ---------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,18,594.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 42 & 43 (Schedule of Credit) of Tender document
CHILLANA CONSTRUCTION COMPANY
M/s Verma Construction Company
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .