| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-Finance | L1 | Accepted-Finance ACCEPTED BEING L1 BIDDER | |
| 2 | L2₹42.4 L+₹46,821 (1.12%)Rejected-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L2 | Rejected-Finance REJECTED BEING L2 BIDDER | |
| 3 | L3₹43.7 L+₹1.8 L (4.37%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING L3 BIDDER | |
| 4 | L4₹45.5 L+₹3.6 L (8.66%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING L4 BIDDER | |
| 5 | L5₹48.6 L+₹6.6 L (15.8%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING L5 BIDDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
27 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHILLONG
GE SHILLONG PIN 793 002
ADDITION/ALTERATION TO BUILDING NO A-215 AND A-217 (OR MARRIED ACCN) OF 58 GTC HAPPY VALLEY UNDER GE SHILLONG
2022_MES_518287_2
GE/SHL/TOKEN-08/2022
Open Tender
Civil Works
Item Rate
240 days
GE SHILLONG
please refer tender documents
9 documents required · 9 mandatory
₹500
GE SHILLONG
₹94,000
Yes
24 Jun 2022
14 May 2022
28 May 2022
14 May 2022
27 May 2022
14 May 2022
60 days
Amount
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling,including dismantling wall and ceilling boards of any description including cover fillets complete all as specified and directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section of unframed work complete all as specified and as directed.
M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sec are exc 6 sq cm n exc 13 sq cm complete all as specified and as directed.
M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sec are exc 3 Sq cm and n exc 6 sq cm complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F 500 litres capacity rotational moulded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling complete all as specified and as directed. Make : Sintex, Polycon, waterwell.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
M&L for Rendering, 15 mm thick plaster in CM ( 1:4), in two layers, top 5 mm thick with approved Water proofing compound @ 3% by the weight of cement or as per manufacturers instructions over a layer of 10 mm thick base coat including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. (Note:WPC shall be measured and paid separately)
M&L for 10mm thick plaster in CM (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed.
M & L for rendering 05 mm thick plaster in CM 1:3 on ceiling surfaces of cement concrete and finished the surface even and smooth without using extra cement complete all as specified & directed .
Supply only integral water proofing compound.
M&L for complete removal of existing treatment from external surfaces of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and as directed.
M&L for preparation of new plaster external surfaces of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and as directed.
M&L for complete removal of existing treatment and applying 1mm thick of wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of wall primer complete all as specified and as directed.
M & L for preparation of new plastered/concrete surfaces of walls, providing one coat of wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of wall primer complete all as specified and as directed.
M&L for preparation of old plastered surfaces of ceiling and providing 1mm thick wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of primer complete all as specified and as directed.
M & L for preparation of new plastered/concrete surfaces of ceiling, providing one coat of wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of primer complete all as specified and as directed..
M&L for Preparation old decorated plastered surfaces of walls and applying Two coats of white wash all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceiling including cornices, plasters etc and applying two coats of white wash complete all as specified and directed
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 100mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in path/ hardstanding incl finishing even & smooth without using extra cement complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection/path incl finishing even & smooth with using extra cement, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) as in surface channels and drains complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles of size 450 x 350 x 7mm thick in vertical wall etc set and jointed in neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in CM (1:4) complete all as specified and as directed.
M&L for Non-skid ceramic coloured tiles 7 to 8 mm thick , (square/rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for Non-skid ceramic coloured tiles 7 to 8 mm thick , (square/rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors, dado , skirting and riser etc, set and jointed in cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing course in CM (1:4) complete all as specified and directed
Demolition of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or platform etc all as specified and as directed.
M & for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps cooking platforms, and other similar situation complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for RCC types B1 1:2:4 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm (ii) Screed bed or bedding layer of CM (1:4) in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed.
Taking down GI tubing 15mm dia and connections including removable to store complete all as specified and as directed.
Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and as directed.
Refixing only 15mm bore GI tube of medium grade including necessary fittings such as GI bends, tee, union etc to walls and ceilings or laying in floors complete all as specified and directed.
Taking down GI tubing 20mm dia and connections including removable to store complete all as specified and directed.
Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and as directed.
Refixing only 20 mm bore GI tube of medium grade including necessary fittings such as GI bends, tee, union etc to walls and ceilings or laying in floors complete all as specified and directed.
M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar (1:3) complete all as specified and directed.
S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. .
S & F in repair 15 mm bore CP fancy type bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 15 mm bore Gun metal gate valves with iron wheelhead, screwed both ends for iron pipe complete all as specified and directed.
S & F in repair 20 mm bore Gun metal gate valves with iron wheelhead, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail 600mm long between the flanges and 20mm dia complete all as specified and directed.
S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S & F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as directed by Engineer-in-Charge as in repairs
S&F in repair for Grating doom 150 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed.
S&F in repairs Vitreous China wash down water down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete aal as specified and directed.
S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mmcomplete all as specified and directed by Engineer in Charge.(Make : Bluestar,Nirali or equivalent.)
S&F in repair ABS Body Health Faucet with Rubbit cleaning system, 1.25m long fles tube in chrome finish & wall hook, fixed in position all as specified and directed. Make: Hindware Cat No. F 160027 euivalent series in Kohler/Roca.
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl 75mm dia complete all as specified and as directed.
S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified.
S&F in repairs PVC (SWR) bend with access door of 75mm bore complete all as specified.
S & F in repair 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed
S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed.
S & F in repair 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specofied and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed.
Taking down shutter of any description n.exc 1 Sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but not exc 2.00 sqm each complete all as specified and directed.
S&F MS flat iron such as small articles for hold fast and similar work all as specified and as directed by Engineer-In-Charge.
M&L PCC (1:3:6) type C1 (20mm graded Aggregate) for fixing hold fast complete all as specified and as directed.
Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Supply and fixing to chowkhats 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers shutters as specified in SSR Part I, Section 8, clause 8.24 (a )complete all as specified and directed.
S&F 35mm thick 2nd class HW Glazed and skeleton windows, ventilators open rebated and prepared to receive glass, gauze, etc. are provided with stiles and rails with sash bar complete all as specified in SSR Part I section 8 clause 8.24 (b) all specified and as directed.
Supply and fixing 35mm thick 2nd class HW Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tub as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Supply and fixing 100mm size butt hinges cold rolled medium weight, ISI marked complete all as specified and directed.
Supply and fixing 75mm size butt hinges cold rolled medium weight ISI marked complete all as specified and directed.
Supply and fixing 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolt all as specified and as directed .
S&F 150mm long extruded aluminium handle fabricated type anodised all as specified and as directed .
S&F 125mm long extruded aluminium handle fabricated type anodised all as specified and as directed .
Supply and fixing 250mm long MS sliding door bolt, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed.
S & F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S & F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all a specified complete all as specified and directed.
Supply and fixing in repairs 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed.
Supply and fixing in repair 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
Supply and fixing in repair 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples comlete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed.
S&F Sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F one side frosted glass 3 mm thick, glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed.
Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, completeall as specified and directed.
S & F in repair 18/19mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and as directed.
S & F 40mm width of flaps when open Continuous (piano) hinges,mild steel, bright finish or electro galvanised complete all as specified and directed.
S & F Magnatic catcher and connected plate to shutters and frame complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed
Material & Labour for concealed Point wiring with two single core 1.5 sqmm (nominal area), FRLSH, ISI marked PVC Insulated unsheathed multistranded copper cable, 1100 volts grade including PVC Conduit of suitable size with all fittings and accessories including PVC rectangular board of suitable size, and FRLSH, ISI marked PVC insulated unsheathed single core multistranded copper cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one way switch including cutting chases not exc 10cm girth and making good disturbed surfaces complete all as specified and directed complete all as specified and directed by Engineer in Charge.
All as per Item No. 2 here-in-before but for one multi pin socket outlet, 5 Amps on independent board, complete all as specified and directed.
All as per Item No. 2 here-in-before but for one multi pin socket outlet, 5 Amps on same board, complete all as specified and directed.
All as per Item No. 2 here-in-before but for one call bell point controlled by one push button switch, complete all as specified and directed.
All as per Item No. 2 here-in-before but for One light point controlled by two 2-way switches,complete all as specified and directed.
All as per Item No. 2 here-in-before but with FRLSH, ISI marked PVC insulated and unsheathed two single core multistranded copper cable of size 4.0 sqmm for one power point ,3 pin 15 Amps on independent board including FRLSH, ISI marked PVC insulated unsheathed single core multi-stranded copper cable of size 4.00 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed.
Supply and fix switch piano type two way 240 volts, 6Amps all as specified and directedcat part No: 1066 of Anchor cona gold series or equivalent in SSK/Havellscomplete all as specified and directed.
S&F Switch socket combination 2 in 1 5A/16A, 3 pin flush type universal complete all as specified and directed. complete all as specified and directed.
S&F socket outlet 2 in 1,3 pin 5 A flush type complete all as specified and directed.
M&L ceiling rose, 3 terminals PVC/polycarbonate, isolated body complete all as specified and directed.
S&F Bell push 6A, flush type single pole one way 230 volts complete all as specified and as directed.
Supply and fixing call bell electric ding dong, AC, 230 V, Single pole ISI marked all as specified and directed. Make- Havells/anchor/ Legrand.
Supply and fixing LED batten fitting 18/20 Watt, 6500 K lumen output not less than 100 lumen/watt fixed to wall with 2 nos PVC block of suitable size and including taking down old unserviceable light fittings complete all as specified and directed.
Supply and fixing LED batten fitting 9/10 Watt, 6500 K lumen output not less than 100 lumen/watt 2 feet fixed to wall with 2 nos PVC block of suitable size and including taking down old unserviceable light fittings complete all as specified and directed.
S&F lamp holder, insulated body, with back plate for batten fitting incl taking down old unsv one complete all as specified and directed.. Make- Havells/anchor/Legrand.
Supply & fixing 7 watt LED lamp B22 type incl taking down old one complete all as specified & directed by Engr-in-Cjarge. Make : Phillips/Bajaj/Havells
Material and labour for concealed sub main wiring with two single core 6.0 sqmm FRLSH, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLSH , ISI marked, PVC insulated multistranded copper conductor cable of size 6.0 sqmm green colour as earth lead including PVC conduit of suitable size including cutting chases not exc 10cm girth and making good disturbed surfaces complete all as specified and directed, including taking down unservicable one complete all as specified and directed. (Note: Two run of 6.0 sqmm cable , one run of earth wire of 6.0 sqmm and one run of PVC conduit shall be measured as one length).
Supply and fix MCB Distribution board , 240 volts Single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection including taking down old unserviceable one complete all as specified and as directed
Supply and fix RCBO 30 mA 32 Amps, double pole including taking down old one complete all as specified and directed by Engineer in Charge.
Supply and fix MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series and including taking down old one. complete all as specified and as directed
Supply and fix MCCB Distribution board , 415 volts vertical triple pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection including taking down old unserviceable one complete all as specified and directed
Supply and fixing MCCB four Pole ,415 Volts, 63 Amps, 16 kA, fixed thermal and magnetic setting including taking down old one complete all as specified and directed
Supply and fixing in repair to single phase temper proof digital electronic meters with polycarbonate cover 230 Volts LCD Display 10-60 Amps, accuracy class-I 50 Hz conforming to IS 13779, IP-54 with parameters to show data, time, current reading, load,PF, voltage and KWH Make :- L&T/ Legrand/Schneider including taking down old unserviceable meters to MES store and including connection and complete all as specified and as directed .
Supplying, fixing and testing of exhaust fan 230 volts , 250mm sweep, copper winding made of sturdy engineering plastic complete with louvers shutter including cutting of hole on wall and making good disturbed surface of wall and outer wooden box for fan fix on wall complete all as specified and directed by Engr-in-Charge. Make: Orient/Havells/Bajaj/Crompton
Supplying, fixing and testing of exhaust fan 230 volts , 150mm sweep, copper winding made of steel complete with louvers shutter including cutting of hole on wall and making good disturbed surface of wall and outer wooden box for fan fix on wall complete all as specified and directed by Engr-in-Charge. Make Orient/Havells/Bajaj/Crompton
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket of suitable size ansd clamps for fixing connection with three core cable 1.5 sqmm complete all as specified and as directed by Engineer in Charge. Make:- Bajaj /Havells / Phillips
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. complete all as specified and directed.
S K Construction
M/S Nakul Chandra Samal
S K DEY
Ms Amrik Singh Bahra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .