Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.7 Cr+₹3.0 L (1.83%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹1.7 Cr+₹3.0 L (1.83%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹1.7 Cr+₹3.9 L (2.35%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹1.7 Cr+₹3.9 L (2.35%) | L3 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | kailu construction co L1 | Sant Construction Co. L2 | JCC ENGINEERS PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundations, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed. | 75.6 | Cum | 150 ₹11,340 | 200 ₹15,120 | 125 ₹9,450 Lowest |
| 2.00 | Excavation Over area not exc 1.5 m deep in hard and dense soil and getting out complete all as specified & as directed. | 132.8 | Cum | 170 ₹22,576 | 150 ₹19,920 | 125 ₹16,600 Lowest |
| 3.00 | Excavation Over area exc 1.5 m deep & n. exc. 3 m deep in any type of soil and getting out complete all as specified & as directed. | 5.6 | Cum | 200 ₹1,120 Lowest | 300 ₹1,680 | 200 ₹1,120 Lowest |
| 4.00 | Returning, filling in including watering and well ramming in layers nexc 25cm thick complete all as specified and directed . | 143.8 | Cum | 50 ₹7,190 Lowest | 80 ₹11,504 | 50 ₹7,190 Lowest |
| 5.00 | Removal of excavated soil to a distance not exc 50 metre depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed . | 70.2 | Cum | 50 ₹3,510 Lowest | 80 ₹5,616 | 70 ₹4,914 |
| 6.00 | M&L PCC 1:4:8,nominal mix, type D-2, using 40mm graded crushed stone aggregate as in earthing pit and like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed. | 10 | Cum | 5,500 ₹55,000 Lowest | 6,000 ₹60,000 | 6,500 ₹65,000 |
| 7.00 | M&L RCC M-25 (design mix concrete using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under-reamed piles and mass concrete complete all as specified.and as directed. | 75 | Cum | 6,000 ₹4,50,000 Lowest | 6,200 ₹4,65,000 | 7,000 ₹5,25,000 |
| 8.00 | M&L for form work to sides of pillers posts, struts, piers, columns and stanchions in square or ractangular, complete all as specified and directed. | 210 | Sqm | 370 ₹77,700 | 300 ₹63,000 Lowest | 300 ₹63,000 Lowest |
| 9.00 | M&L For TMT bars (Fe 500) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. | 820 | Kg | 85 ₹69,700 Lowest | 95 ₹77,900 | 85 ₹69,700 Lowest |
| 10.00 | M&L For TMT bars (Fe 500) 6 to 8 mm dia, cut to length, bent to shape required,incl cranking, bending spirallyfor hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. | 897 | Kg | 85 ₹76,245 Lowest | 95 ₹85,215 | 85 ₹76,245 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
4 Oct 2025, 6:00 pmClosed
CWE PATHANKOT
HQ CWE PATHANKOT
PROVN OF STANDBY 5 MVA POWER TRANSFORMER AT JANGLOT UNDER GE BASOLI
2025_MES_716074_2
CWE/P-38/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE BASOLI
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE BASOLI
₹2.2 L
Yes
19 Feb 2026
13 Sept 2025
6 Oct 2025
13 Sept 2025
4 Oct 2025
20 Sept 2025
Amount
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundations, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Excavation Over area not exc 1.5 m deep in hard and dense soil and getting out complete all as specified & as directed.
Excavation Over area exc 1.5 m deep & n. exc. 3 m deep in any type of soil and getting out complete all as specified & as directed.
Returning, filling in including watering and well ramming in layers nexc 25cm thick complete all as specified and directed .
Removal of excavated soil to a distance not exc 50 metre depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed .
M&L PCC 1:4:8,nominal mix, type D-2, using 40mm graded crushed stone aggregate as in earthing pit and like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
M&L RCC M-25 (design mix concrete using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under-reamed piles and mass concrete complete all as specified.and as directed.
M&L for form work to sides of pillers posts, struts, piers, columns and stanchions in square or ractangular, complete all as specified and directed.
M&L For TMT bars (Fe 500) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L For TMT bars (Fe 500) 6 to 8 mm dia, cut to length, bent to shape required,incl cranking, bending spirallyfor hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
M&L For mild steel rag or Lewis bolts, screwed one end , with hexagonal or square nuts with washers, the other end enlarged and jagged or lewised , exc 30 cm long dia of bolt 20mm to 25mm, complete all as specified and as directed.
M&L for PCC 1:3:6, (M-10) nominal mix, type C-2, using 40mm graded crushed stone aggregate as in earthing pit and like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks built in CM 1:4 straight or curved on plan exc 6m mean radius, complete all as specified and directed.
M&L for providing, cement concrete 1:2:4 type B-1 (using 20mm graded aggregate ), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick or concrete surface walls, in cement mortar 1:4, rendering is to be finished even and fair without using extra cement, complete all as specified and directed.
M&L framed work such as grills,gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, framework for roof chajjas including welding works if so required and similar work conforming to Fe.290.Gde-E-165 , complete all as specified and directed.
M&L Mild steel plates (plain or chequered) channel, square cut or notched (ordinary and counter sunk) forming holes (Fe 410W) Gde 250 Quality-A, without any attachment complete all as specified and as directed.
M&L for painting two coats of synthetic enamel paint incl preparation to steel surfaces n exc 10 cm width or girth,complete all as specified and directed .
M&L for preparation of new steel surfaces having width/girth exceeding 10 cm and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed
Supply and laying in trenches, through pipes or under culvert of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 volts (earthed grade) incl copper strip tapping IS 7098 Part 2-1985 grade with stranded aluminum conductor of size 300 Sqmm x 3 core laid in duct/through pipe complete all as specified and as directed.
M&L for Cable end jointing kit for 11 KV (earthed grade) cable for outdoor type termination heat shrinkable type joint complete with all jointing material and accessories suitable for 3 core XLPE HT armoured aluminum conductor cable of size 300 sq mm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE HT armoured aluminum conductor cable of size 300 sqmm complete all as specified and directed.
Supply ,installation ,Testing and commissioning platform mounting outdoor type, Step down power transformer of 66/11 KV, capacity 5 MVA ONAN, 3 Phase, 50 HZ copper wound, two winding, core type transformer as per IS-2026 star star vector group & IEC :76 YNyn0, On load Tap changer on HV side (+) 5% to (-) 15% in step of 1.25%, Outdoor type, vector group YNyn0, tapping terminal arrangement ,initial filling of transformer oil as per IS - 335 mounted on PCC platform as per manufacturer’s instructions and drawing complete with making connection from 66 KV HT bushing on 66 KV side and cable end box on 11 KV side including under mentioned parameters and accessories complete all as specified & directed.
(a) Rating HV/LV : 66/11 KV (b) Cooling : ONAN (c) Type of transformer : Two winding (d) No load losses at rated voltage & frequency shall be 6.5 KW (IS ToL) (e) Load losses at rated current & 75 deg C 34 KW (IS ToL) (f) Temp rise shall be 45/55 deg C for oil/winding respectivily over and above ambient temp of 50 deg C. (g) Services : Outdoor type (h) Impedence HV/LV : 7.15 % (IS Tol) (j) Vector group : YNyn0 (k) Winding : copper (l) Magnetic core : Prime grade of M4 or better (m) Insulation level - H.V power frequency (KV rms) : 28 KV -HV ,impulse withstand voltage (KV peak ) : 75 KVp. (n) Tap Changer : On load tap changer on HV side +5% to -15% on load tap links in steps of 1.25 % (16 steps) (o) HT termination : Bushings (p) LT termination: Cable box with all accessories i.e first filling of filtered dehydrated oil and confirming to IS & standard accessories required.
(B) Accessories: (i) Buchholz Relay with alarm and trip contact and shut off valve-02 Nos. (ii) Oil Temperature indicatior 150mm dia with alarm and trip contact. (iii) Winding Temperature Indicator with alarm and trip contact. (iv) Marshalling box 200 TB (MK) (v) Magnetic Oil level Gauge (vi) Pressure release valve (PRV) with trip contacts (vii)Conservator with oil filling hole with cap and drain plug and with built in diaphram to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking (ix) Thermometer pockets with thermometer (x) Silica gel breather (xi) Air Release plug (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized Aluminum Rating and diagram plate (xvi) On Load Tap Changer (OLTC) with remote operation. (xvii) Top filter valve. (xviii) Bottom drain cum filter valve (xx) RTCC Panel (xxi) AVR Panel. (xxii) 72.5 KV Neutral CT of ratio (150-75/1) -01 No.(xxiii) 12 KV Neutral CT of ratio (900-450/5) -01 No . (xxiv) Oil surge relay-01 no. (xxv) Explosion vent with diaphram- 01No (xxvi) Radiator- one set. (xxvii) PCC plateform of suitable size with steps as per manufacturers drawing and recommendations.
(xxviii) Oil soakage pit with drainage system as per manufacturer instructions. Note: (i) The erection of transformer shall be under the supervision of manufacturer's auth rep & certificate .In this regard, drawing shall be submitted by contractor duly signed by auth rep of manufacturer & Engineer-in-Charge before errection. (ii) RTCC and AVR Panel shall be suitable for automatic voltage regulation with master follower scheme with tap position indicator as per tap indication in the OLTC mechanism. RTCC should also be provided with control gear in respect of fan ON/OFF indication, auto & manual control switch, AC supply on and tap changer in progress indication lamp, tap struck indication and alarm. (iii) The core shall be constructed from high grade, non ageing, prime grade CRGO with M4 grade or better, silicon steel laminations and shall be of bottle ness design. The core material shall be purchased directly from manufacturer (Pasco /Nippon/Novex/AK steel’s) or from their accredited marketing organization.
(iv) Manufacturer shall have in house automated core cutting facility to ascertain that there is no mixing of second grade core (v) The core and core assembly should be dried through a high efficient vacuum drying autoclave for heating and drying . (vi) Manufacturer shall have in house NABL accredited lab to ascertain the authenticity of test results. BIS approved CPRI, type test report as per IS-2026 of power transformer should be of similar or higher rating to be submitted by the contractor at the time of make approval.
Supply, installation, testing and commissioning of Circuit breaker SF-6 out door type 66 KV nominal voltage 3 Phase, 50 HZ as per IEC-62271-100 complete with all accessories and of the following technical specifications complete all as specified and as directed. (a) Highest system voltage between phase: 72.5 KV. (b) Rated normal current : 1650 Amps. (c) Rated power frequency withstand voltage : 160 KV. (d) Rated lightning impulse withstand voltage: 350 Kvp. (e) Short circuit breaking current : 31.5 KA (f) Short circuit making current : 80 Kap. (g) Rated duration of short circuit:3 seconds (h) Minimum creep age distnace to ground ; 1820mm. (j) Type of mechanism enclosed in housing Motor operated spring-spring. (k) Rated operating sequence : 0-0.3 Sec-CO-3 MIN-CO. (l) Rated closing/tripping voltage : 110 VDC (m) Current of closing/tripping coil: 6 A max at 110 VDC. (n) Rated current for terminal connections: 630 Amps.
Supply ,installation,testing and commissioning of Heavy duty metal oxide lightning arresters 60 KV 10 KA station medium duty (SM) (old line discharge class -III) as per IEC 60099-4 of 2014 & IS: 15086 (part -4) of 2017 with Qrs=1.6C & wth =7kJ/kV gapless type surge Arrester comprising of Metal Oxide Elements housed in FRP CAGE 'DESIGN B' duly moulded with silicone Polymer to be used on a Nominal system voltage of 66 kV and Maximum System Voltage of 72 kV with an MCOV of 51 kVrms with insulating Base & surge Monitor along with connecting lead of 35 sqmm Cu Cable of 2 meter length with Terminal connector suitable to Single ACSR conductor complete all as specified and directed.
Supply ,installation, testing and commissioning of 72.5 KV Isolator for nominal voltage 66 KV system 50 Hz 3 phase system of capacity 1250 Amp continuous current, short time current 31.5 KA for 3 Seconds complete with the following specifications all as specified and as directed. Insulation levels (a) Impulse with stand voltage: (i) Phase to earth : 325 kVp (ii) Isolating distance : 325 kVp (b) Power frequency with stand voltage: (i) Phase to earth : 140 kV(rms) (ii) Isolating distance : 160 kV (rms) (c) Minimum creep age distance of support and rotating insulator : 1820mm (d) Minimum clearance in air: (a) Phase to phase centre distance : 2000mm (b) Between live part and earth : 630mm
(c) Between live part when switch is open : 950mm (i) On the same pole : 950mm (ii) Between adjacent pole : 1300mm (e) Current density:- (i) Moving blades : 2 Amps/Sqmm (ii) Terminal pads : 17 Amp/Sqmm (iii) Contacts : 1.60 Amps/Sqmm (iv) Terminal connector : 1.25 Amp/Sqmm Design & Construction (a) No insulator per pole : 03 (b) Nos of breaks per pole : 02 (c) Type of closing/Opening mechanism : Horizontal (d) Contacts (i) Material & grade : Hard drawn electrolytic copper (ii) Cross Section Area in Sqmm : 960 Sqmm (e) Moving blades (i) Material & grade : Hard drawn electrolytic copper (ii) Cross Section Area in Sqmm : 706 Sqmm
(f) Contacts support (i) Material & size of channel/block ; AL LM-6 casting (g) Turn & twist mechanism (i) Material & size of clamps : MS 20 x 20mm (ii) Material & size of spring duty ; Dia 2.6 SS encased (h) Type of Interlock : Mechanical & Electrical (j) Down pipe size & class : 50 NB Med - HPG (k) Type of joint : Swivel (l) Solid core type insulator (i) Height : 770mm (ii) PCD : 127mm (iii) Impulse flash over voltage : 400 kVp (m) Terminal connector (i)Alloy composition : AL LM-6 (ii) Area of minimum cross section : 1000 Sqmm (iii) Temperature rise : As per IS-9921 (n) Operating mechanism : Mortar drive & Manual
All as per Srl item No 28 above but with line & earth switch, pressure relieving type isolator and in addition fitted with mechanically interlocked manually operated earthing blades having an auxiliary switch with 4 NO and 4 NC contacts for earthing side etc alongwith interlocking feature all as per technical detail, complete all as specified and directed.
Supply, installation ,testing and commissioning of 72.5 KV Single Phase, Dead tank type outdoor CT (current transformer) CT ratio 150/75/1-1-1 A for metering & protection, including junction box complete, oil cooled, insulation level -140 KV/325 KVp short time current rating -50KA/1 Seconds, 3 core of above setting, 50 VA/0.2 class accuracy with oil as per IEC-60044-1 & IS-2705 suitable for 66 KV complete all as specified and as directed with following accessories:- (a) Differential protection current Ratio : 150-75/1 (b) Over current & earth protection current ratio : 150-75/1 (c) Metering current ratio :150-75/1 (d) Accuracy : Class 0.2
M&L for structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminum paint over one coat of red oxide / zinc chrome primer including preparation of surfaces, complete all as specified & directed.
M&Lfor stretching of over head bus bar at receiving station for 66 KV comprising of 2 feeder bay inclusive of (Panther ACSR) Conductor and PG clamps etc complete with 66 KV string insulator 120 KN (as per site requirement) and 7/8 K SWG GI Shield wire, and busbar insulators , clamps and connections. all as specified . Note : The rate for PG clamps, string insulator tee off clamps etc shall deemed to be included in unit rate quoted by the contractor, However rates for ACSR conductor(Panther ), GI Shield wire shall be measured and paid under respective item.
S&F of 66 KV post Insulator 120 KN Complete Set all as specified and directed.
S&F for ACSR conductor (Penther) including supply & fixing of copper binding wire or aluminium tapes (weight not to be added in the weight of conductor) complete all as specified and directed.
S&F of 8 K SWG/4mm GI Shield wire complete all as specified and directed.
M&Lfor MS flat 50 x 6 mm for connecting earthing electrode to fencing equipments, earthing mesh in the yard etc complete all as specified and directed. Note :- (i) MS flat will be buried 60cm below ground level (ii) Cost of earth work, (excavation, removal and returning filling in etc) wherever required is deemed to be included in the quoted rate of the item.
M&L for Earthing complete with copper earth plate electrode 600x600x 3.15 mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.25 Mtr below normal ground level connected to the copper strip 20x3 mm size by means of bolts ,nuts,check nuts and washers of brass and 20x3 mm copper strip protected by provision of GI medium grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle, earth work in any type of soil ,charcoal dust and salt, light grade GI watering pipe 20 mm bore with funnel and wire and copper strip upto main earthing of pole/equipment complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed . Note:- (i) Up to 7.5 Mtr length of pipe of 40 mm dia and copper strip shall be deemed to be included in unit rate quoted by the tenderer. (ii) Resistance of earthing should be less than 1 Ohms failing which the contractor will do the earthing again to achieve the desired result i.e. less than 1 ohms (iii) In case soil is not suitable same is to be replaced with good quality clay soil to achieve the desired result of less than 1 ohms (iv) Quoted rate shall be deemed to be inclusive for the above aspects’.
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6mm by means of nuts bolts, washers, check nuts of GI steel all as shown in electric plate no 3 of SSR -2009 Part I, all as specified and indicated complete and including charcoal dust, salt etc and GI protection pipe medium grade 40mm and GI watering pipe 20mm light grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit, earth work in any type of soil and connected all as specified and as directed. Note :- (i) Up to 7.5 Mtr length of pipe of 40 mm dia and copper strip shall be deemed to be included in unit rate quoted by the tenderer ‘(ii) Resistance of earthing should be less than 1 Ohms failing which the contractor will do the earthing again to achieve the desired result i.e. less than 1 ohms (iii) In case soil is not suitable same is to be replaced with good quality clay soil to achieve the desired result of less than 1 ohms (iv) Quoted rate shall be deemed to be inclusive for the above aspects’.
M&L for earthing strip 50 x 5 mm copper strip with suitable extension pieces to the structure including screws complete all as specified and directed.
S&F for Copper strip 32 x 6 mm complete with saddles/insulators made out of porcelain or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints all as required at site complete all as specified and directed.
M&L for Pea gravel 20 to 40 mm graded of granite, Trap or basalt stone hand packing (any thickness ) in sub station all as per latest engineering practice and directed.
M&L for PVC insulated and PVC Round Sheathed, Multicore Annealed Bare solid or stranded Copper Conductor (flexible) for control cable in ducts from 66 KV Yard to Panel Room 2.5 sqmm 2 core cable complete all as specified and directed.
M&L for PVC insulated and PVC Round Sheathed, Multicore Annealed Bare solid or stranded Copper Conductor (flexible) for control cable in ducts from 66 KV Yard to Panel Room 2.5 sqmm 4 core cable complete all as specified and directed.
M&L for PVC insulated and PVC Round Sheathed, Multicore Annealed Bare solid or stranded Copper Conductor (flexible) for control cable in ducts from 66 KV Yard to Panel Room 2.5 sqmm 8 core cable complete all as specified and directed.
M&L for PVC insulated and PVC Round Sheathed, Multicore Annealed Bare solid or stranded Copper Conductor (flexible) for control cable in ducts from 66 KV Yard to Panel Room 2.5 sqmm 12 core cable complete all as specified and directed.
M&L for shifting of existing LAs (set of three), Potential transformer (set of three) , Current transformer (set of three) of 66 kV and allied accessories as directed by Engr-n-chagre complete with junction boxes, control cables to proposed steel sturcture without damaging the equipment and testing after commissioning the equipments complete all as specified and directed. Note: (a) All T & P required for shifting of above mentioned equipments shall be included in quoted rates. (b) In case of any damage to any equipment during shifting, shall be replaced by the contractor with new ones without any extra cost to Govt/ department.
Supply, install, testing and commissioning 66 KV Control and relay panel for the operating system of grid for complete operation working of 66 KV CT,PT SF-6 outdoor and protection of thermometer including relays DHT MBCH,VAA II VAJH 13 ,VAX 31-2 Nos Numerical relay SPAJI40 with annunciator 16 ways KVAR ,power factor meter, frequency meter ,ammeter voltmeter KWH meter having master follower scheme ,black out scheme complete with following accessories:- Control and relay panel for the operating system of 66 KV grid transformer for complete operational working of 66 KV CT, PT, SF-6 outdoor and protection of thermometer including relay DHT MBCH VAA II, VAJH 13 VAX 31-2 IDMT relay non directional type with annunciator 16 ways KVAR power factor meter, KWH meter having master follower scheme complete with following accessories:- The panel shall be simplex type & consisting of seperate cubicals (for each side complete with side cover) made out of sheet steel of thickness not less than 10 SWG to the base frame, door frame and front portion. For Transformer (a)15 points solid state alarm annuciator suitable for 110 V DC-01 No (b) Hooter 110 V DC-01 No make system and device (c) Ammeter 0-75-150A Size 144 mm x 144 mm - 01 No
(d) Voltmeter (0-75) KV, size 144 mm x 144 -01 No Make : Meco/AE (e) Power factor meter (0.5 lag 1-0.5 lead) 1A, 110 V, 3 Phase, 3 wire 2 elements size 144 x 144 mm - 01 No (f) frequency meter (45-50-55) Hz 110 V AC, size144 mm x 144 - 01 No (g) KVAR meter 3 phase 3 wire, 2 elements size 144 mm x 144 - 01 No (h) Energy meter 3 phase, 3 wire, 2 elements 110 V flush mounting - 01 No (j) Semaphone indicator 48 mm dia, 110 V DC - 03 Nos (k) Semaphone indicator 63 mm dia, 110 V DC - 01 No (l) Brakar control switch with loss motion device - 01 No (m) Numerical Transformer differential relay RET 521 suitable for 1A Aux supply 110 V DC (n) Over current cum E/F relay numerical tpe REX521 relay with 3 No O/C elements with setting (50%-200%) of 1A, 1 No E/F elements setting range (10%-40%) of 1A - 01 No (o) Aux relay type RXSF suitable for 110 V case size 1/4 N - 01 No
Sant Construction Co. (BID ID -3437154)
JCC ENGINEERS PRIVATE LIMITED (BID ID -3430782)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .