Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | ₹20.9 L Quoted ₹22.2 L | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹23.1 LRejected-Finance | ₹23.1 L | L2 | Rejected-Finance Being Other than Lowest Bidder |
| 3 | L3₹23.5 LRejected-Finance | ₹23.5 L | L3 | Rejected-Finance Being Other than Lowest Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in Cat b (i) |
| Sl No | Description | Qty | Unit | m/s varsha traders L2 | M/S STEAD FAST L3 | M/s YOGESH ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully existing unserviceable point wiring of any description & in any position with and including pvc/steel conduit including all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. | 438 | Per Point | 5 ₹2,190 | 10 ₹4,380 | 10 ₹4,380 |
| 2.00 | Material and labour for point wiring for one light point /fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade FRLS cable in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed FRLS cable as in earth wire connected to common earth dolly complete all as specified and directed. | 60 | Per Point | 260 ₹15,600 | 350 ₹21,000 | 510 ₹30,600 |
| 3.00 | Material and labour for point wiring for one 5 pin socket outlet 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade FRLS in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed FRLS cable as in earth wire connected to common earth dolly complete all as specified and directed. | 50 | Per Point | 300 ₹15,000 | 450 ₹22,500 | 515 ₹25,750 |
| 4.00 | Description all as per item No 03 here-in-before but point wiring for one 5 pin socket outlet, 5/6 Amps on same board with other switch complete all as specified and directed. | 20 | Per Point | 120 ₹2,400 | 150 ₹3,000 | 150 ₹3,000 |
| 5.00 | Description all as per item No 03 here-in-before but point wiring for one 6 pin socket outlet, 15/5 Amps (independent board) complete all as specified and directed. | 25 | Per Point | 260 ₹6,500 | 450 ₹11,250 | 498 ₹12,450 |
| 6.00 | Material and labour for point wiring for one light point/fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade FRLS in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed FRLS cable as in earth wire connected to common earth dolly including taking out unserviceable wiring complete all as specified and directed. | 100 | Per Point | 260 ₹26,000 | 320 ₹32,000 | 490 ₹49,000 |
| 7.00 | Description all as per item no 06 above but point wiring two way switch complete all as specified and directed. | 10 | Per Point | 300 ₹3,000 | 400 ₹4,000 | 525 ₹5,250 |
| 8.00 | Material and labour for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly including taking out old u/s wiring from conduit complete all as specified and directed. | 20 | Per Point | 300 ₹6,000 | 400 ₹8,000 | 500 ₹10,000 |
| 9.00 | Description all as per item no 08 here-in-before but point wiring for one 6 pin socket outlet, 15/5 Amps(Independent) complete all as specified and directed. | 13 | Per Point | 260 ₹3,380 | 400 ₹5,200 | 510 ₹6,630 |
| 10.00 | Material and labour for point wiring for one light point /fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade FRLS in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed FRLS cable as in earth wire connected to common earth dolly complete all as specified and directed.
Note :The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers. | 150 | Per Point | 260 ₹39,000 | 420 ₹63,000 | 495 ₹74,250 |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Dec 2025, 6:00 pmClosed
GE(AF) ADM AREA
GE (AF) ADM AREA GWALIOR -474020
REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND OTHER ASSOCIATED MISC WORKS IN OUTSIDE POCKET AREA, OTM AREA AND CHETAK COMPLEX AREA UNDER GE ADM AT AF STN GWALIOR
2025_MES_737805_1
8537/E8
Open Tender
Civil Works
330 days
GE (AF) ADM AREA GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) ADM AREA
₹80,000
Yes
26 Dec 2025
30 Oct 2025
8 Dec 2025
30 Oct 2025
1 Dec 2025
17 Nov 2025
Amount
Taking down carefully existing unserviceable point wiring of any description & in any position with and including pvc/steel conduit including all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring for one light point /fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade FRLS cable in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed FRLS cable as in earth wire connected to common earth dolly complete all as specified and directed.
Material and labour for point wiring for one 5 pin socket outlet 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade FRLS in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed FRLS cable as in earth wire connected to common earth dolly complete all as specified and directed.
Description all as per item No 03 here-in-before but point wiring for one 5 pin socket outlet, 5/6 Amps on same board with other switch complete all as specified and directed.
Description all as per item No 03 here-in-before but point wiring for one 6 pin socket outlet, 15/5 Amps (independent board) complete all as specified and directed.
Material and labour for point wiring for one light point/fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade FRLS in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed FRLS cable as in earth wire connected to common earth dolly including taking out unserviceable wiring complete all as specified and directed.
Description all as per item no 06 above but point wiring two way switch complete all as specified and directed.
Material and labour for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly including taking out old u/s wiring from conduit complete all as specified and directed.
Description all as per item no 08 here-in-before but point wiring for one 6 pin socket outlet, 15/5 Amps(Independent) complete all as specified and directed.
Description all as per item no 10 above but point wiring for two way switch complete all as specified and directed.
Material and labour for point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board. controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
Description all as per item No 12 above but point wiring for one 5 pin socket outlet, on same board complete all as specified and directed.
Description all as per item No 12 above but point wiring for one six pin socket outlet, 15/5 Amps (independent board) complete all as specified and directed. Note :- For Item No 02 to 14 - Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A. Note :- For Item ser No 02,06,07,10 & 11- (a) For Lights points 01 circuit shall have maximum 08 light points.(b) For 05 Amps sockets same board maximum 02 sockets in one circuit with light point. Note :- For Item ser No 03 , 04 ,05 ,08 ,09 ,12,13 & 14 - (a) For Socket outlet Independent 6 Amps (01 circuit with maximum 4 points). (b) For Socket outlet 16 Amps(01 circuit of 01 point only). General Note for all item of contract against BOQ :- (a) Being Maint work the quantum of work will be in piecemeal manner with no extra cost to the contractor.(b) The material shall be procured after get the same approved and will be kept in custody of department in advance.
M & L for switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified and directed.
M & L for switch flush type single pole two way 5 Amps, 240 volts, white ivory finish complete all as specified and directed.
M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specified and directed.
S&F switch socket combination multi purpose, 5 Pin 6 amps, flush type complete all as specified and directed.
S&F switch socket combination multi purpose, 6 Pin 6/16 amps, flush type complete all as specified and directed.
S&F for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified and directed.
S&F for lamp holder insulated body with back plate for batten fitting complete all as specified and directed.
Supplying & fixing in repair switch bell push, flush type, 5 Amps, single pole, one way , 230 volts AC circuit white ivory finish complete all as specified and directed.
Supply and fixing in repair bell Ding Dong ,AC 230 V.single pole complete all as specified and directed.
Supply and Fixing in repair step type electronic fan regulator single phase ,230 volt, 100/120 watt . (Size of PT switch ) complete all as specified and directed.
S&F in repair switch socket combination multi purpose, 5 Pin 6 amps, flush type complete all as specified and directed.
S&F in repair switch socket combination multi purpose, 6 Pin 6/16 amps, flush type complete all as specified and directed.
S&F in repair switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified and directed.
Supply and fixing in repair surface mounted type LUMILINE PLUS NEO light fitting complete 1x 20 watt (4 ft), 6500K , onsite servce 2 year, Average life 50000 hrs LED lightning fixture with extruded aluminium housing integrated electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable suitable size. etc complete all as specified and directed. Make :- Havells cat part No LUMILINEPLUSNEOBS20WLED830SPCSSINDS or Wipro cat part No Wipro Garnet 20w Aluminium Led Batten or Jaquar BIT-WHT- LGLZU1X022XC.
Supply and fixing in repair surface mounted type LUMILINE PLUS NEO light fitting complete 1x 10 watt (4 ft), 6500K Average lifr 50000 hrs LED lightning fixture with extruded aluminium housing integrated electronic driver complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper pvc sheathed conductor cable suitable size. etc complete all as specified and directed. Make :- Havells cat part No LUMILINEPLUSNEOBS10WLED865SPCSSINDS or Wipro cat part No/model No Garnet D531027 or Philips Model No - 919515813927_1 / Jaquar BTI-WHT-LGLZ01X020XC .
S&F in repair LED bulk head fitting 10 watt energy saving new generation IP 65 luminatre with opel diffuser complete with lamp complete all as specified and directed. Make - Crompton Cat part No BLKD-XELLO-10W-CDL or HEXAFT10WLED857SSYMBOPC of Havells or WP1160 wipro garnet 10 watt of Wipro
Supply and fixing in repair Street light fittings LED 35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (25 mm GI pipe light grade ),clamp,nut-bolt and washers complete all as specified and directed.
Supply and fixing in repair of sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires including taking out existing MCB/MCCBs complete all as specified and directed. Note:- Existing MCB/MCCBs in serviceable condition shall be taken out carefully for reuse in the work.
All as per item No 32 above but DB’s 12 way complete all as specified and directed.
Supply and fixing in repair DB Double door TPN 4 way 415 volts complete , fixed properly on MS strips and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified and directed.
S&F MCB single pole 6 to 30 Amps, 'B' Curve ,240 Volts complete all as specified and directed.
S&F MCB Single pole and neutral 40 Amps, 240 Volts 'B' curve complete all as specified and directed.
Supply and fix Four pole MCB TPN 100 Amps, 10 KA, 240 Volts complete all as specified and directed.
Supplying & fixing MCCB, 3 pole, 125 Amps, 50Hz, 415 Volts with rupturing capacity 35/36 KA with thermal magnetic release and adjustable overload setting having type DPX 125 conforming to IEC-609472 & IS-139473 to be fixed in distribution board, complete all as specified & directed.
M&L in repair for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts grade in existing steel / PVC conduit, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per item No 40 as above but using copper conductor cable 4 Sqmm and 4 Sqmm cable for earth wire complete all as specified and directed.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor FRLS cable of size 6 Sqmm of voltage rating upto and including 1100 Volts grade in and including conceled PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FRLS of size 6 Sqmm as earth continuity conductor all as specified and directed including taking down old submain wiring along with any type of conduit complete all as specified and directed. NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per item No 42 as above but with copper conductor cable of size 4 Sqmm with 4 Sqmm earth wire and PVC conduit 20mm dia med grade complete all as specified and directed.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor FRLS cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including surface PVC conduit med grade of dia not less than 25mm with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FRLS of size 10.0 Sqmm as earth continuity conductor complete all as specified and directed. NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per item No 44 but 6 Sqmm cable and 6 sqmm earth wire and 20mm pvc conduit complete all as specified and directed.
All as per item No 44 but 4 Sqmm cable and 4 sqmm earth wire and 20mm pvc conduit complete all as specified and directed.
M&L in repair for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers complete all as specified and directed.
S&F in repair 35W/36W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal Fixture size 600x600 mm complete with LED tube with driver and all accessories complete all as specified and directed.
S & F in repair of LED Tube light 18/20 watt crystal glass double side including all connection complete all as specified and directed.
Fixing only switch socket combination 5 pin, 5 Amp, flush type , AC 230 Volts complete all as specified and directed. Note- Existing serviceable switch socket combination and batten fitting retrieved after taking down of point wiring shall be used under item no 01 of BOQ.
Fixing only switch socket combination 6 pin, 15 Amp ( 3 pin 5 Amp & 3 pin 15 Amp), flush type , AC 230 Volts complete all as specified and directed. Note for items no 50,51 & 52 - Existing serviceable switch socket combination and batten fitting retrieved after taking down of point wiring shall be used under item no 01 of BOQ.
Fixing only any type batten fittings complete all as specified and directed. Note for items no 50,51 & 52 - Existing serviceable switch socket combination and batten fitting retrieved after taking down of point wiring shall be used under item no 01 of BOQ.
Fixing only and connecting & testing serviceable MCB (SP/ SPN/ TPN/ Four pole ) upto 63 Amps complete all as specified and directed. Note:- Existing serviceable MCB retrived after taking down of MCB DBs shall be used.
S&F in repair lamp holder angular type insulated body with back plate for battern fitting completed all as specified and directed.
S&F picture light, 1.2 watt, 3000 kelvin temp, energy efficient, 420 lumen, wall mount, rectangular shape, warm light, flush mount, material in matal complete all as speicified and directed
m/s varsha traders (BID ID -3481205)
M/S STEAD FAST (BID ID -3481711)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tender8537.pdf
Tender Documents • 0.96 MB
BOQ_826140.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid