Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.8 CrAdmitted-Finance HN 2K 74 KANKE 2K 74 BARIATU HOUSING COLONY BARIATU RANCHI 834009 JHARKHAND VILLAGE TOWN RANCHI CITY RANCHI RANCHI JHARKHAND 834009 INDIA | RANCHI | JHARKHAND | 834009 | L1 | Admitted-Finance | ||
| 2 | L2₹13.1 Cr+₹34.8 L (2.72%)Admitted-Finance P 21 OLD BALLYGUNGE ROAD KOLKATA 700019 | KOLKATA | KOLKATA | WEST BENGAL | 700019 | L2 | Admitted-Finance | ||
| 3 | L3₹14.1 Cr+₹1.3 Cr (10.5%)Admitted-Finance AMRUTHA VARSHINI 325 3RD A CROSS SECTOR A YELAHANKA NEWTOWN BENGALURU 560064 | BENGALURU | BENGALURU | KARNATAKA | 560064 | L3 | Admitted-Finance | ||
| 4 | L4₹16.4 Cr+₹3.6 Cr (28.4%)Admitted-Finance | L4 | Admitted-Finance |
Tender Value
₹12.4 Cr
Closing Date
31 Jan 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GGM/SNT
Plot 1 Sector 29 Gurgaon Haryana
Design, Supply, Installation and commissioning of all the In-door and Outdoor Signaling and Telecommunication works, and other allied works at Delhi Kishanganj of Delhi Division in Northern Railway
2022_RITES_100531_1
RITES/CO/RI/SnT/PMC/NR/Delhi Kishang/2021-22
Open Tender
Miscellaneous Works
Percentage
365 days
Gurgaon
As per Tender Document
3 documents required · 3 mandatory
₹18,000
Yes
RITES Ltd
Exempted
6 Apr 2022
4 Jan 2022
1 Feb 2022
4 Jan 2022
31 Jan 2022
4 Jan 2022
4 Jan 2022 - 24 Jan 2022
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1 | INDOOR SUPPLY | - | - | - | - | - |
| 2 | Supply of Electronic Interlocking (Hot Standby) with dual VDU of 55" (OR more size as per requirement and instruction of site Engineer) with Signalling functions as per RDSO Specification No. RDSO/SPN/192/2019 Ver.2.0 and to suit the signalling plan and to suit the signalling plan of stations.Scope of supply against this item includes all the indoor equipments necessary for successful functioning of Central EI system, mainly consisting of but not limited to followings conforming to attached Technical specifications .
1. Microprocessor equipment.
2. I/O cards with card cage and motherboard.
3. Power supply cards.
4. All types of connectors and couplers as required.
5. Industrial grade Dual VDU of 55"(OR more size as per requirement and instruction of site Engineer) .
6. Industrial grade PC & monitor of 55"(OR more size as per requirement and instruction of site Engineer)
7. maintenance VDU of 55" console (OR more size as per requirement and instruction of site Engineer) with Laser printer at panel building.
8. All types of relays required for interfacing. | - | - | - | - | - |
| 3 | 9. ECRs suitable for LED signal lamps.
10. DC-DC convertors (input voltage 110 V DC and output voltage as required)
11. All types of indoor wires as required.
12. All types of indoor terminals and fuses as required except
terminals for main CTR. | - | - | - | - | - |
| 4 | 13. Racks for mounting EI equipments and interfacing relays.
14. Termination rack for indoor cables.
15. Fixtures, mounting arrangements, Ladders for wire run and other accessories as required.
16. Softwares used for designing, configuration, maintenance, data logging and fault diagnosis of EI system.
17. Protective devices like lightning protectors for DC and AC supplies, isolator/convertor for serial communication etc.
18. Documents and manuals as per RDSO/SPN/192/2019 Ver.2.0 in three sets.
19. Ring Earthing and EMI shielding of EI room.
20. Any other item contractor feels neccessary as per their sysyem.
21.Completion plan of stations.
22. Class 'A' type surge protection device protection at each SSI room/goomty, mounting arrangements and accessories necessary to make the EI system functional.
23. Work place for EI is also provided by the contactor | - | - | - | - | - |
| 6 | Delhi Kishan Ganj | 1 | System | 2,77,03,142 | ₹2,77,03,142 | 1% |
| 7 | Spares of O&M | - | - | - | - | - |
| 8 | Supply of all spares to the extent of 10% of that supplied against EI item subject to minimum of one, for the cards/modules,connectors /couplers, fuses & relays. used in the EI system. Item-wise details of spares to be supplied with unit rates should be listed out by the tenderer along with offer. | 1 | Lot | 9,69,609.97 | ₹9,69,609.97 | 1% |
| 9 | Delhi Kishan Ganj | - | - | - | - | - |
| 10 | Supply of Laptop based work station for data inputs & configuration, simulation and functional testing, diagnostics, trouble shooting and commissioning of EI system, complete with necessary softwares preloaded as per specifications mentioned in TS. | 1 | No. | 1,28,316.98 | ₹1,28,316.98 | 1% |
| 11 | Tool kits and Measuring Instruments for Technicians /Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer of EI. * Above items includes suitable cabinet for storing tools to ensure longer life. | 1 | Set | 1,23,929.56 | ₹1,23,929.56 | 1% |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
Tender.pdf
Tender Documents • 6.31 MB
BOQ_109495.xls
BOQ • 1.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .