Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.2 L+₹56,985.66 (1.86%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST TENDERER | |
| 3 | L3₹35.3 L+₹4.7 L (15.4%)Rejected-Finance MAIN ROAD KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU AND KASHMIR | 181221 | L3 | Rejected-Finance OTHER THAN LOWEST TENDERER | |
| 4 | L4₹38.0 L+₹7.5 L (24.4%)Rejected-Finance NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | L4 | Rejected-Finance OTHER THAN LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹74,660
Closing Date
2 Aug 2021, 6:00 pmClosed
CWE
HQ CWE DHAR ROAD
SPECIAL REPAIR TO P 105 AND ROOF TREATMENT OF P 264 AND P 265 AT 15 FAD UNDER GE ARMY DHAR ROAD UDHAMPUR
2021_MES_449845_2
8210/CWE/DR/E8
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE ARMY DHAR ROAD
₹74,660
4 Sept 2021
17 Jul 2021
4 Aug 2021
17 Jul 2021
2 Aug 2021
19 Jul 2021
Amount
Demolition of cement concrete in ground floor, (unreinforced) and paving not exc 15 cm thick (below or above GL) complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc as specified and directed.
M & L 15 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces walls/facias finished even and smooth without using extra cement complete all as specified and directed.
M & L 15 mm thick cement mortar mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L 5mm thick in cement mortar 1:3 on fair faces of concrete surfaces as in ceiling finished even and smooth without using extra cement complete all as specified and directed.
S&F 25 mm aperture wire netting of galvanised steel wire 0.91 mm dia fixed with tinned tacks of wire staples complete all as specified and directed.
extra over rendering or plastering of work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirting, drip moulds nad similar work exc 15 cm but not exc 30cm in widths or girth, including cutting to edges, all mitres and stopped ends etc. complete all as specified and directed.
M & L for hardcore of gauge exc 63mm but not exc 100 mm of broken stone boulders deposited spread and levelled in layers not exc. 15 c, thick watered and rolled/rammed to a true surface complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C2, using 40mm graded stone aggregate as in plinth protection laid in panel of alternative bays not exc 2.00 Sqm with 6mm wide joints and filled with mastic fillings finished even and smooth without extra cement complete all as specified and directed
M & L for 100 mm thick PCC 1:2:4 type B 2, using 40mm graded aggregate as in flooring, including finishing surface even and smooth without using extra cement including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green in alternate bays complete all as specified and directeced
M & L for 100 mm thick PCC 1:2:4 type B 1, using 20mm graded aggregate as in flooring, including finishing surface even and smooth without using extra cement in alternate bays complete all as specified and directec.
M & L for removing all loose scale and corrosion deposits of the exposed corrugated steel including surface preparation, corrugated steel should be cleaned all around including the back of exposed steel bars and removing all the loose concrete around the reinforcement with the clearance as recommended by the manufacture of rust remover, then applying rust remover with brush by complete wetting the rusted material surface by rust remover and leaving for 24 hrs and therafter surface preparation of coated bars and applying 2nd coat of rust remover and leaving the same for specific period as per manufactyures instructions and further again preparing and cleaning the steel surfaces for treatemnt complete all as specified and directed.
M & L for providing and fixing rebar of required length and diameter with Sika Anchor fix @ 3 Fosroc lockflod equivalent in BASF Wherever required in RCC members including power drilling, cleaning of holes then rebar should be inserted in the holes that should be filled with eproxy as mentioned above to ensure the bond as per manufacturer instructions, complete for following diameter of bars as per site requirement complete all as specified and directed (Wherever required necessary welding of rebars shall also be done with main reinforcement with any extra cost) (a) 8mm/10mm/12mm TMT bars
(b) 16mm/20mm/25mm TMT bars
CORROSION RESISTANCE COATING M&L for applying passivator/anti corrosion coating to the preapred surfaces of items No 13 above the material shall be cement base polymer modified coating for corrosion protection and shall be applied as per manufacturer insturctions complete all as specified and directed
Applying material and labour for preparation of old RCC/concrete surface and applying a coat of two components solvent free epoxy bonding agent using brush after cleaning of surface from all dust all as per manufacturer insturctions complete all as specified and directed. Note: The new concrete suface shall be places within the open time as specified by the manufacturer to ensure maximum bonding.
PATCH WORK FOR INSUFFICIENT CONCRETE COVER OR SOFFIT AREA OF CONCRETE Providing and applying ready to use simple component high strength polymer modified cementious repair mortar 25 mm thick and water/powder ratio complete as specified and directed by manufacturer so as to achieve the following parameters. Compressive strength 28 days strength >= 50 N/mm/Sq
Taking down existing roof treatment of water proofing of any discription including plaster and cleaning top surfaces with wire brushes complete all as specified and directed.
M & L for 10mm thick plaster in cement mortar 1:3 finished even and smooth (without using extra cement) mixed with integral water proofing compound @ 3% by weight of cement applied over roof slab. After the plaster is cured the roof will be tested for water tightening by ponding with water for seven days for any seepage/leakage etc if any seepage is observed the rectfication shall be carried out by high pressure gourting under the pressure of 5 Kg/Sqm using cement grout After the surface is repaired the slab is tested for water tightness again before processing further treatement complete all as specified and directed (WPC shall be measured and paid separately)
Self adhesive elastomenc SBS bitumen based water proofing membrane 1.5mm thick with coarse laminated polythene film surface. The upper side and easily removable silicon film on the underside, laid on roofs and sealing all joints and including applying bitumen primer @ 0.30 ltrs/Sqm over clean RCC roof surface complete all as specified and directed Note: The work shall only be executed through authorised approved applicator by the manufacturer of membrane)
Supply only integral water proofing compound complete all as specified and directed
Dismantling of Asbestos cement corrugated sheets as in roof coverings complete all as specified and directed
S & F 6mm thick Asbestos cement corrugated or semi corrugated sheets in roofs fixed with L type of J type hook bolts complete all as specified and directed
Demolition of brick work/stone masonry built in cement mortar including all quions, arches, pillars etc complete all as specified and directed
M & L for brick work with old size sub class 'B' burnt clay bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1 6 complete all as specified and directed
M & L for brick work with old size sub class 'B' burnt clay bricks, (except bricks) straight or curved on plan exc 6m mean radius. built in cement mortar 1:6 complete all as specified and directed
Taking down old chowkats or frame with shutter of any description (without taking off shutter from the frame) area not exceeding 1.5 sqm and removing material from site of work complete all as specified and directed
S & F factory made steel ventilators with top hung shutter including hinges, steel peg stay with glazing pin headed type complete all as specified and directed
S & F factory made steel ventilators with top hung shutter including hinges, steel peg stay buth without, glazing bars complete all as specified and directed
S &F figured glass, 4 mm thick pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed
S & F wire netting of stainless steel wire 1.4mm dia and average 20mm fixed with tinned tacks of stainless steel wire staples complete all as specified and directed
Taking down existing unserviceable rolling shutters complete of any size and type complete all as specified and directed
S & F Steel rolling shutters without ball bearing with thickness of lathes 1.25mm including top cover anchoring rod, hasp and staple and one shop coat of primer and erected in position push, pull or manual type complete all as specified and directed
S & F in repairs steel ball bearing suitable for rolling shutters for smooth functioning of rolling shutter complete all as specified and directed
M & L two coats of cement base paint of camouflage pattern over a coat of primer Ind preparation of old decorated plastered surfaces complete all as specified and directed
M & L two coats of fire resistant paint over a coat of primer Incl preparation of new plastered surfaces on walls complete all as specified and directed
M & L two coats of fire resistant paint over a coat of primer incl preparation of new plastered surfaces on ceiling complete all as specified and directed
M & L two coats of exterior weather coat camouflaging pattern over on coat primer Incl complete removal of existing treatment and preparation of new/old decorated surfaces of bldg of height upto 10 mtr including scafolding work complete all as specified and directed
M &L for applying one coat of fire resisting paint on old plastered/concrete surfaces of wall over 10 cm girth or width incl preparation of surface complete all as specified and directed
M &L for applying one coat of fire resisting paint on old plastered/concrete surfaces of ceiling Incl preparation of surface complete all as specified and directed
M &L for applying two coats of fire resistant paint over a coat of red oxide primer Incl preparation of new steel surface complete all as specified and directed
M &L for one coat of fire resistant paint Ind preparation of old steel surface complete all as specified and directed
Dismantling of structural steel work including doors, gates, purlins and angle/ Tee sections incl chequered plates and mild steel sheet, valley gutter as in framed work etc (excluding framed trusses) complete all as specified and directed
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, cattle traps etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides and hanging also fastening and fixing conforming to grade Fe-410 W (Gde E-250) quality B complete all as specified and directed
S & F 1.25 thick mild steel sheet as in ridges, hips, valley gutter drips and straight flashing (length and girth as fixed) complete all as specified and directed
Dismantling and breaking up old PVC drain pipes of 100/110 mm dia jointed in cement mortar and taking out of trenches and removing materials from site of work complete all as specified and directed
S &F in repairs 110 mm bore PVC (SWR) pipe single socketed in any length fixed to wall with rubber ring joint, ISI marked complete all as specified and directed
S &Fin repairs 110 mm bore (any radius) PVC (SWR) bend, ISI marked complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick buried in ground vertically to a depth not less than 2.25 mm below ground level with top edge of the earth plate not less than 1.5 mm below normal ground level, connected to GI strip 32 x 6 mm continuity conductor including 40 mm bore pipe light grade for protection of strip by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to earth test point upto 7.5 mt away from earth electrode all as shown as per plate No 03 of SSR I including necessary earth work, PCC 1:3:6 type C 1 chamber, RCC cover slab of 50 mm thick 1::2:4 with 8 mm CTD 140 mm C/C with suitable handle,watering pipe 20 mm dia light grade pipe with funnel,. charcoal salt and testing on completion all as specified and directed. Incl Taking Down
M&L for air termination single pointed aluminium rod 12 mm dia and 300 mm long lightening conductor tube 40 mm on buildings with F1 clamps nut bolts complete all as specified and directed.
M&L for earth test point terminal block made out of gun metal or phorphorus bronze size 75 x 75 x 25 mm , drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw grouting on wall with PCC, nut bolts and washers, including making good to disturbed surface complete all as specified and directed.
M&L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down on ductors above ground all as directed and specified
M & L for PCC (1:2:4 ) type B-2 in cement concrete in foundation, filling and mass concrete using 40 mm fraded stone complete all as specified and directed.
S & F GI tubing light grade 40 mm bore fixing in bricks/stone/in trenches/fixing on pole/wall/crossing in drain etc complete all as specified and directed for fixing lightening arrester on roof top.
Taking down old hanging GI strip (damaged by Monkey) from roof wall complete
Dismantling and Taking down old damaged air termination rod fixed on GI Pipe from existing PCC mounting complete
Dismantling and Removing all existing PCC work on existing lightening conductor,GI pipe etc all complete as specified anf=d directed by eng-in-charge.
Taking down UNSV Earthing item any type complete
M/S PAWAN KUMAR ANAND
M/S SANJAY STEEL WORKS
M/s Khajuria Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .