Tender Value
Refer Docs
Closing Date
22 Feb 2024, 3:00 pmClosed
Mr.SUSHANT DESHPANDE
thyssenkrupp Uhde India Private Limited Formerly thyssenkrupp Industrial Solutions(India) Private Ltd
Supply of Dual Plate Check Valve for MSB, PFCC, GDS Unit for NREP as per Technical Specifications for Numaligarh Refinery Limited, Assam, INDIA
2024_NRL_792216_1
TK-1ZZZA-MP-RFQ-0130
Limited
Miscellaneous Goods
Supply
210 days
Numaligarh Refinery Limited Assam, India
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
Exempted
5 Jun 2024
25 Jan 2024
23 Feb 2024
25 Jan 2024
22 Feb 2024
7 Feb 2024
25 Jan 2024 - 5 Feb 2024
GROUP -1(Group-Wise Evaluation) SUPPLY OF DUAL PLATE CHECK VALVES (MOC-CS) for NREP PROJECT incuding TPI charges as specified in Material Requisition. (Qty : 58) (Bidder to provide Line item Wise Price Break Up of Complete Group in BoQ2 Sl.No : 1.001 to 1.019 )
GROUP -2 (Group-Wise Evaluation) SUPPLY OF DUAL PLATE CHECK VALVES (MOC-LTCS) for NREP PROJECT incuding TPI charges as specified in Material Requisition. (Qty : 16) (Bidder to provide Line item Wise Price Break Up of Complete Group in BoQ2 Sl.No : 2.001 to 2.006 )
Description of Work / Item(s)
GROUP -1(Group-Wise Evaluation) SUPPLY OF DUAL PLATE CHECK VALVES (MOC-CS) for NREP PROJECT incuding TPI charges as specified in Material Requisition. (Qty : 58) (Bidder to provide Line item Wise Price Break Up of Complete Group in BoQ2 Sl.No : 1.001 to 1.019 )
DUAL PLATE CHK VLV CS INT.COAT, 150,0, API 594, DOUBLE FLGD,B16.5,FF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, BRONZE, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, INTERNALLY LIQUID EPOXY COATED ACC. TO, DOC. NR-0ZZZZ-CV-SPE-0019, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VLV CS INT.COAT, 150,0, API 594, DOUBLE FLGD,B16.5,FF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, BRONZE, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, INTERNALLY LIQUID EPOXY COATED ACC. TO, DOC. NR-0ZZZZ-CV-SPE-0019, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VLV CS INT.COAT, 150,0, API 594, DOUBLE FLGD,B16.5,FF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, BRONZE, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, INTERNALLY LIQUID EPOXY COATED ACC. TO, DOC. NR-0ZZZZ-CV-SPE-0019, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VLV CS INT.COAT, 150,0, API 594, DOUBLE FLGD,B16.5,FF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, BRONZE, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, INTERNALLY LIQUID EPOXY COATED ACC. TO, DOC. NR-0ZZZZ-CV-SPE-0019, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS, 150,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS, 150,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS, 150,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (H2), 150,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS, 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS, 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS, 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VLV CS(NACE+H2), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., SERVICE NACE, CATEGORY 1, A216 Gr.WCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103,NR-0ZZZZ-PI-SPE-0025 AND IN-043, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (H2), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (H2), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (H2), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., A216 Gr.WCB, 5, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (NACE), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., SERVICE NACE, CATEGORY 1, A216 Gr.WCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103,NR-0ZZZZ-PI-SPE-0025 AND IN-043, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (NACE), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., SERVICE NACE, CATEGORY 1, A216 Gr.WCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103,NR-0ZZZZ-PI-SPE-0025 AND IN-043, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (NACE), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., SERVICE NACE, CATEGORY 1, A216 Gr.WCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103,NR-0ZZZZ-PI-SPE-0025 AND IN-043, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE CS (NACE), 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., SERVICE NACE, CATEGORY 1, A216 Gr.WCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103,NR-0ZZZZ-PI-SPE-0025 AND IN-043, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
GROUP -2 (Group-Wise Evaluation) SUPPLY OF DUAL PLATE CHECK VALVES (MOC-LTCS) for NREP PROJECT incuding TPI charges as specified in Material Requisition. (Qty : 16) (Bidder to provide Line item Wise Price Break Up of Complete Group in BoQ2 Sl.No : 2.001 to 2.006 )
DUAL PLATE CHK VALVE LTCS, 150,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A352 Gr.LCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE LTCS, 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A352 Gr.LCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE LTCS, 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A352 Gr.LCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE LTCS, 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A352 Gr.LCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE LTCS NACE, 300,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, ALL WELDS SHALL BE SUBJECTED, TO PWHT., SERVICE NACE, CATEGORY 1, A352 Gr.LCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103,NR-0ZZZZ-PI-SPE-0025 AND IN-043, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
DUAL PLATE CHK VALVE LTCS, 600,0, API 594, DOUBLE FLGD,B16.5,RF, DESIGN DUAL PLATE (TYPE A), DOUBLE FLGD (FIG. C.4,API 594), INSTALLATION HORIZ./VERTICAL, A352 Gr.LCB, 12, SPRING INCONEL X-750, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0005,TK-1ZZZA-PI-SPE-0006,, TK-1ZZZA-PI-SPE-0008,TK-1ZZZA-PI-SPE-0009, AND IN-042, VENDOR TO ENSURE ADEQUATE, NUT SPACE BETWEEN FLANGES
advance valves pvt ltd
Flovel Valves Pvt Ltd
LIBRA ENGINEERING WORKS
NITON VALVE INDUSTRIES PVT LTD
advance valves pvt ltd
Flovel Valves Pvt Ltd
LIBRA ENGINEERING WORKS
NITON VALVE INDUSTRIES PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .