Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.8 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹90.0 L+₹14.9 L (19.9%)Rejected-Finance | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹91.2 L+₹16.1 L (21.5%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹96.7 L+₹21.6 L (28.7%)Rejected-Finance | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹1.3 Cr+₹53.2 L (70.9%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹99.5 L
EMD Value
₹1.7 L
Closing Date
4 Sept 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR MAINTENANCE OF FIRE FIGHTING SYSTEM AND CONNECTED WORKS AT RS AREA BLDGS UNDER GE NW NAVY NAGAR COLABA MUMBAI
2024_MES_662680_1
8204/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar
As per tender documents
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹1.7 L
Yes
CWE (NW) Mumbai
16 Nov 2024
28 Jun 2024
6 Sept 2024
28 Jun 2024
4 Sept 2024
18 Jul 2024
28 Jun 2024 - 11 Jul 2024
11 Jul 2024
Amount
Repair/Routine maintenance including carrying out daily check of fire alarm/fire fighting system complete with electronic control panel inthe following buildings including personnel to attend the fire alarm system faults, testing, checking and replacement of unserviceable minor components ie nuts, bolts, washers etc other than mentioned in schedule here-in after and fire alarm system consisting the following :- (a) Indicator (b) Electronic fire control panel (c) Manual call point (d) Smoke detector (e) Heat detector (f) Electronic fire control panel (g) Main/Zone (h) Battery of fire panel DC supply (J) All wiring and cable connections Details of bldgs are as under :- (a) R1, R2, R3, R4, R5, R6, R7, R8, R9, R10,R12,R13,R14, R15, R16, R17, R18, R19, R20, R21, R23, R24, , R26 , R27, , R28, R29, R30, R31, R32, R33, R34 & R35, Mithun bldg (G+14/ floors) ie 15 stories (b) R -11, R-22, R-25, R-36, R-37, R-38, R-39 bldgs (G + 6 /7 stories) (c) NCS School (d) WNC (O) Mess Note :- 1. Contractor shall also to provide adequate skilled manpower for testing of fire fighting system of buildings as per schedule to be issued by the user section. The cost of testing shall be deemed to be included in the item rate. 2. Minor Items like fuses, loop cards, detectors circuits are required at site to make functional are included in the item rate. 3. Contractor technician and helper should daily report to JE E/M regarding maintenance of work at site.
Supply , installation, testing & commissioning in repairs of micro processor based 2 wire fault tolerant loop, required loop networkable type 2 loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be capable to give location of all fire/fault conditions of addressable units via the address. The panel shall have rectifier, Loop cards, LCD unit to indicate Fire/Fault Signal with address. The panel shall have a built in power supply and battery charger along with maintenance free SMF Lead acid batteries as per manufacturers design with battery charger complete as required and as per specifications duly approved by EN 54 complete including making connections all as specified and directed by Engineer-in-charge. Make : Morley-IAS by Honeywell model Name/Number DXc2/714-001-225 or Bosch model NO FPA-1000-V2/Schneider cat No FFSULH1002 Model No ESM, ULTIMA or techno-commercial equivalent of make given in Appx B.
Supply & fixind in repair rubber hose pipe 30 mtr, 20mm dia plain 2 ply rayon braided high pressure complete all as specified and directed.
Supply and fixing in repairs 20 mm dia Stainless steel Shut off nozzle conforming to IS 903 complete all as specified and directed.
Supply & fixing in repair canvas fire hose 63 mm bore 15 m long confirming to IS 636-1988 having male/female SS coupling both end complete all as specified and directed.
Supply & fixing in repair Stainless steel Nozzle conforming to IS 903: 1993, 63 mm x 15 mm bore suitable for 63 mm dia canvas pipe complete all as specified and directed.
Supply & fixing in repair hose Reel drum suitable for 30 mtrs X 20 mm dia rubber hose pipe complete all as specified and directed.
Supply & fixing in repair Maintenance free battery duly charged 12V, 7.2 AH complete all as specified and directed .
Supply,replacement, Installation,Testing & Commissioning in repairs of Addressable Type Manual Call Point voltage - 12 VDC, 24 VDC IP rating- 24 D complete all as specified and directed.
Supply, Installation, Testing and Commissioning in repairs of Addressable electronic sounder cum strobe 115 db, 3 tonnes suitable for indoor and limited outdoor application, red ABS housing complete all as specified and directed.
Supply & fixing in repair detectors complying with addressable type multisensor detector with heat and smoke combination with fixed temperature of 59°C and dual LED combination for 360 degree visibility complete all as specified and directed. Note :- Loop cards, circuits as required to make functional is deemed to be included in the item rate and no extra cost will be paid to the contractor.
Material & labour for repairing of existing unserviceable electronic sounder cum strobe, manual call point, smoke detectors including loop cards e.t.c including opening , soldering of circuits, cleaning, replacement of glass, testing and painting complete all as specified and directed by Engineer-in-Charge.
Supply, laying, joining and testing in repairs of PVC insulated PVC sheathed Copper Conductor cable 1100 Volt, 4 Core 1.5 sq mm including fixing on wall making necessary connection, with busbar/MCCB/DB's & testing complete all as specified and directed.
Supply, laying, joining and testing in repair PVC insulated PVC sheathed armoured copper conductor cable 1100 Volts of size 2 Core x 1.5 Sqmm including fixing on wall making necessary connection, with busbar/MCCB/DB's & testing complete all as specified and directed.
Supply and fixiing in repairs cast iron hydrant valve (ISI Marked) wheel complete all as specified and directed.
Supply and fixing in repairs hydrant gun metal female coupling 63 mm dia all as specified and directed
Supply and fixing in repair 15 mm bore brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings such as elbow, reducer, nipple etc.
Supply and fixing in repair 20 mm bore brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 20 mm bore including necessary GI fittings such as elbow, reducer, nipple etc.
Supply and fixing in repair of gun-metal, gate valve in existing line in position with iron wheel head class I, made out of brass, screwed both ends for GI pipe with union, ISI marked complete all as directed of the following :-
25 mm bore
40 mm bore
50 mm bore
Material and labour for factory fabricated Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs MS ERW pipe 100 mm dia heavy grade, ISI marked, IS 1239 for suction and delivery for pump and for rising main including necessary fitting including welding, painting with red oxide primer & two coat of synthetic enamel paint and providing necessary PCC support, all as specfied and directed by Engineer-in-charge
Supply and fixing in repairs MS ERW pipe 150 mm dia heavy grade, ISI marked, IS 1239 for suction and delivery for pump and for rising main including necessary fitting including welding, painting with red oxide primer & two coat of synthetic enamel paint and providing necessary PCC support, all as specfied and directed by Engineer-in-charge
Supply and fixing in repairs MS ERW pipe 80 mm dia heavy grade, ISI marked, IS 1239 for suction and delivery for pump and for rising main including necessary fitting including welding, painting with red oxide primer & two coat of synthetic enamel paint and providing necessary PCC support, all as specfied and directed by Engineer-in-charge
Supply and fixing in repair non return valve (ISI Marked) for fire brigade inlet all as specified and directed by Engineer-in-Charge
Supply & fixing in repair gun metal Two way fire brigade inlet conection with adaptor of size 80 mm dia X 63 mm dia complete all as specified and directed.
Supply, installation, testing and commissioning of 4- way fire brigade inlet connection, conforming to IS 5290: 1993 with four 63 mm NB inbuilt gunmetal non-return valves, four 63 mm NB instanteneous couplings arranged on 100 mm NB pipe manifold and connected to fire hydrant ring main and fire hydrant wet riser pipe including taking down old and u/s complete all as specified and directed by the engineer-in-charge.
Supply & fixing in repair gun metal twin outlet hydrant valve (ISI Marked) 100 mm having 63 mm outlet with lock pin wheel complete all as specified and directed.
Supply & fixing in repair gun metal single outlet hydrant valve (ISI Marked) 100 mm having 63 mm outlet with lock pin wheel complete all as specified and directed.
Supply and fixing in repair stainless steel hose drum adopter connection (shank reducer) 63 mm dia all as specified and directed
Supply and fixing in repair stainless steel lock pin for 63 mm dia coupling all as specified and directed by Engineer-in-Charge
Supply and fixing in repair PVC female blank cap of hydrant (with chain) all as specified and directed by Engineer-in-Charge
Supply & fixing in repair sluice valve (ISI Marked) 150 mm size both ends flayed with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked, PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply & fixing in repair sluice valve (ISI Marked) 100 mm size both ends flayed with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply & fixing in repair sluice valve (ISI Marked) 80 mm size both ends flayed with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked, PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply and fixing in repair cast iron Foot valve ball type10/15Kg/sqcm of ISI marked in position at location including M&L for making flanged joints and repair and making good to existing PCC surface of following sizes :-
100 mm dia
150 mm dia
Material & labour for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, of size Fe 410-W(GdeE- 250) quality B or all as specified and directed by Engineer-in-Charge.
Taking down/Removing in old plasters, broken bricks, PCC , MS Chanel, MS Plate & debris inside the valve chamber in repair/maintenance of existing brick masonry valve chamber of size 1.2 x 1.2 x 1.2m (internal dimension) (above GL 0.30 mtr) , 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover over complete chamber on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified. Note :- Rates for removing of old plasters, broken stones/bricks, PCC of any type, earth work, M S Chanel, MS Plate e.t.c are deemed to be inclueded in the quoted rated.
Supply and fixing in repair DOL/Star delta starter suitable for 5 HP to 10 HP pump set current relay range 7.5-16 Amp ,3 phase 430 V ,50Hz complete all as specified and directed.
Material & labour for Disconnecting motor from pump of capacity 5 Hp to 20 HP of any Make, model and removing Bearing using bearing puller gear and fixing new bearings at DE /NDE including necessary greasing, check for proper shaft alignments such that no vibration produced during opertion of following capacity Motors, complete all as specified and directed.
Material & labour for Disconnecting motor from pump of capacity 75 Hp to 120 HP of any Make, model and removing Bearing using bearing puller gear and fixing new bearings at DE /NDE including necessary greasing, check for proper shaft alignments such that no vibration produced during opertion of following capacity Motors.
Material and laobur for disconnecting LT cables of various sizes from electric motor of 5HP to 10 HP capacity and decoupling from the pumping sets. Removing and taking down carefully and transporting to authorised workshop for rewinding. Strip opening and dismanting complete rotor and stator assembly. Cutting and taking out old burnt copper winding from the stator assembly and cleaning the slots of stator with carbon tetra chloride solution. Material and labour for rewinding, complete stator assembly with and including super enamelled copper winding, wire of suitable gauge matching with existing. Applying the minimum two coats of insulation varnish and keeping the stator assembly in heating chamber to improve for insulation value. Assembling the motor, transporting to site of work, coupled with the pumping set, alignments properly, connecting the LT cables and commissioning complete all as specified and directed by Engineer-in-Charge
Material and laobur for disconnecting LT cables of various sizes from electric motor of 75 HP to 120 HP capacity and decoupling from the pumping sets. Removing and taking down carefully and transporting to authorised workshop for rewinding. Strip opening and dismanting complete rotor and stator assembly. Cutting and taking out old burnt copper winding from the stator assembly and cleaning the slots of stator with carbon tetra chloride solution. Material and labour for rewinding, complete stator assembly with and including super enamelled copper winding, wire of suitable gauge matching with existing. Applying the minimum two coats of insulation varnish and keeping the stator assembly in heating chamber to improve for insulation value. Assembling the motor, transporting to site of work, coupled with the pumping set, alignments properly, connecting the LT cables and commissioning complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repair Air release valve (ISI Marked) with hand operated ball valve of 25 mm dia with all related fittings whatever is required complete all as specified and directed
Supply and fixing in repair 150 mm bore hand operated butterfly valve (ISI Marked) made of ductile iron of pressure not less than 15 Kg / Sqcm with complete set complete all as specified and directed
Supply and fixing in repair 100 mm bore hand operated butterfly valve made of ductile iron of pressure not less than 15 Kg / Sqcm with complete all as specified and directed
Material and labour to carry out the servicing of the Diesel Engine pump set 90 HP with repair and replacement of worn out/defective spare parts including preventive maintenance and servicing to radiator and connected assemblies:- (a) Oil filter (b) Fuel filter (c) Air filter (d) Coolant (e) Engine Oil as per capacity of engine
Supply and fixing in repairs 32 Amp, 415 Volt, 50 Hz, AC MCB triple pole and earth enclosures with a three pin and earth plug with socket complete with one triple pole complete all as specified and directed
Material & labour cleaning of existing valve chamber and removing of unwanted material such as plastics material, soil/debries/muds etc and depositing where complete all as specified and directed
Material & labour for two coats synthetic enamel painting of hydrant stand post, fire brigade inlet, fire hose box cabinet, fire main rising etc, including preparation of disturbed surface such as bricks works & cement work on existing MS plate and MS channel of valve chamber and repair / maintenance of hinges/opening/ hold fasts etc all as specified and directed.
Supply & fixing in repair pressure gauge 150mm dia range 0-10Kg /Sqcm Oil filled type as per sample. Note: quoted rated should including for providing of adopter /Ferrule/check nut etc required for fixing pressure guage and necessary alterations to MS or CI pipe for taping if required.
Supply and fixing in repair of cast iron Non return valve confirming to IS 5312-1 (2004) including nut, bolts, washer, flanges, gaskets, wleding works etc of the following sizes :-
150 mm dia
100 mm dia
80 mm dia
Supplying, installing ,testing and commissioning of MS air cushion tank, conforming to IS 4736:1968 on top of each riser fabricated from 6 mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8 mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25 mm NB valve, pressure gauge with gun metal stop cock including taking down old and u/s air cushion tank complete all as specified and directed by the engineer-in-charge.
Supply and fixing in repair of steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done at any installation or buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall including concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge of following sizes :-
15 mm bore
20 mm bore
25 mm bore
Supply & fixing in repair PVC water storage Tank 5000 ltr capacity 2 layers , ISI marked, hosting and fixing in position at any location removing existing tank disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection including replacement of tank nipples and GI fittings as required at site complete all as specified and directed. Note : Rate deemed to be included demolition of existing foundation and reconstruction of same.
Supply and fixing in repair MS fittings bend/ tee/ flange/ elbow/ blind flange/ slip on flange of size 80/100/150/200 mm, ISI marked, IS 1239 for suction and delivery for pump and for rising main including necessary fitting including welding, painting with red oxide primer & two coat of synthetic enamel paint and providing necessary PCC support, all as specified and directed by Engineer-in-charge
Supply and laying in repair of spigot and socket ductile iron water tubing, class K-9, 150 mm bore cement mortar lining on inner surface and one coat of bituminous paint over exposed surface, ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carrying out testing against leakage before returning and filling in trenches etc complete all as specified and directed by Engr-in-Charge.
Supply and laying in repair of spigot and socket ductile iron water tubing, class K-9, 100 mm bore cement mortar lining on inner surface and one coat of bituminous paint over exposed surface, ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carrying out testing against leakage before returning and filling in trenches etc complete all as specified and directed by Engr-in-Charge.
Material and labour for Cast Iron/ Ductile Iron specials conforming to IS - 1538, spigot /socket or flanged fitting such as bends, tees, collars, flanged/ socket /spigot, Tappers and tail pieces etc suitable for 100/150 mm bore pipes including lead joints complete all as specified and directed by Engr-in-Charge.
Excavating in trenches not exceeding 1.5 metre wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in soft/loose of soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material exc 250m but n.exc 500m and depositing where directed complete all as specified and directed by Engr-in-Charge.
Demolition of Exisiting cement concrete supporting block of pumps and motor exceeding 15 cm thickness above ground level complete all as specified and directed by Engr-in-Charge.
Material and labour for cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete for providing support for Base frame with MS bolts placed in concrete finishing even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. Note: Location and size of bolts should match as per the previous concrete supporting blocks.
Supply and fixing in repair rubber vibration pads heavy duty for base frame as per sample suitable for the following capacity of pumpsets complete all as specified and directed by Engr-in-Charge. :-
50 HP to 75 HP
05 HP to 15 HP
Supply and fixing in repair soft starter 3 phase,415 volt with comprehensive motor protection, programmable over load protection built in RTD and thermistor input with constant current adoptive acceleration and deceleration for smooth start and stop operation of motor of following capacity :-
Suppy and fixing in repair bitumen pachment on damaged road not exceeding 15 cm depth and make well ramming complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 60× 60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected using galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by light grade 40 mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 40 mm bore for watering and including funnel, wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:2:4 type C2 (incl excavation and earth work disposal of surplus soil to a distance not exceeding 50 Mtr) made a suitable size test point and testing after completion all as specified and shown on plate No 3 connected to earthing test point. Note:- All kind of earth work all included in the quoted rate.
Supply and laying in replacement of PVC insulated unarmoured copper power cable of sizes given below including HDPE pipe of suitable size fixing on walls with saddles complete all as specified and directed by Engr-in-Charge.
Single core 35 Sq mm cable.
Single core 25 Sq mm cable.
Single core 16 Sq mm cable.
Supply and fix in repairs hydrant stainless steel female coupling 63 mm dia all as specified and directed
Hardik Engineers (BID ID -3066867)
ASHOK ENTERPRISES (BID ID -3071544)
Shetty Construction Co (BID ID -3071855)
Shree Ayyappa Engineering (BID ID -3071891)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .