Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC 39 RIFLE RANGE ROAD KOLKATA 19 | KOLKATA | KOLKATA | WEST BENGAL | 700019 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.1 L+₹5.8 L (25.1%)Rejected-AOC 64 CALLIN STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-AOC 2nd Lowest Bidder | |
| 3 | L3₹29.3 L+₹6.1 L (26.0%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | L4₹31.6 L+₹8.4 L (35.9%)Rejected-Finance 63 PILKHANA ROAD BERHAMPORE MURSHIDABAD 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L4 | Rejected-Finance 4th Lowest Bidder | |
| 5 | L5₹32.5 L+₹9.2 L (39.5%)Rejected-Finance VILL GOPINATHPUR P O NAKOLE P S SHYAMPUR DIST HOWRAH | HOWRAH | HOWRAH | WEST BENGAL | L5 | Rejected-Finance 5th lowest bidder |
Tender Value
Refer Docs
EMD Value
₹73,292
Closing Date
7 Sept 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE-I, WKED, PWD
New Sectt. Building, 1, K.S. Roy Road, C-Block, 4th floor, Kolkata-700 001
Arrangement of Cable tray for dressing of existing cables from cornice to tray and boxing by another metal non perforated cable tray concealing the exposed portion of different Telephone and TV signal cable line by casing capping at Kolkata Raj Bhava
2020_WBPWD_293400_1
WBPWD/EE-WKED/NIQ-03/2020-21
Open Tender
Electrical Work/ Equipment
Item Rate
60 days
Raj Bhavan
Please refer Tender documents.
3 documents required · 3 mandatory
₹73,292
Yes
2 Dec 2020
18 Aug 2020
9 Sept 2020
18 Aug 2020
7 Sept 2020
19 Aug 2020
90 days
Amount
Supply & Fixing of following sizes boxing GI cable tray having two parts i) perforated bottom, perforation not more than 7% with depth 75mm ii) non perforated top overlapping cover depth 25mm and fixing with bottom tray by required sizes steel screwing arrangement, rest on S & F of "L" shaped G.I Angle iron structure 2 nos. per mrt length (32mm x 32mm x 5mm angle length mentioed with the following tray) fixed on wall by two nos. 4 inches/required sizes steel fastener etc. as required and mending good damages to original finish, Incl. weather cote spary painting (wall matching colour)of front depth of boxing & angle support with wall matching color as per direction of EIC.
i) 200x75x2.04mm (14SWG), "L" shaped angle structure length 500mm
ii) 300x75x2.04mm (14SWG) "L" shaped angle structure length 600mm
iii) 150x75x2.04mm(14SWG)"L" shaped angle structure length 400mm
Supply & Fixing of following sizes boxing GI cable tray bend having two parts i) perforated bottom, perforation not more than 7% with depth 75mm ii) non perforated top overlapping cover depth 25mm and fixing with bottom tray by required sizes steel screwing arrangement, rest on S & F of "L" shaped G.I Angle iron structure 1(one no.) for each bend (32mm x 32mm x 5mm angle length mentioed with the following tray) fixed on wall by two nos. 4 inches/required sizes steel fastener etc. as required and mending good damages to original finish,incl. weather cote spary painting(wall matching colour) of front depth of boxing & angle support with wall matching color as per direction of EIC.
i) 200x50x2.04mm (14SWG)"L" shaped angle structure length 500mm
ii) 300x50x2.04mm (14SWG)"L" shaped angle structure length 600mm
iii) 150x75x2.04mm(14SWG)"L" shaped angle structure length 400mm
Supply & Fixing of following sizes boxing GI cable tray reducer having two parts i) perforated bottom, perforation not more than 7% with depth 75mm ii) non perforated top overlapping cover depth 25mm and fixing with bottom tray by required sizes steel screwing arrangement, rest on S & F of "L" shaped G.I Angle iron structure 1no. for each reducer (32mm x 32mm x 5mm angle length mentioed with the following tray) fixed on wall by two nos. 4 inches/required sizes steel fastener etc. as required and mending good damages to original finish, Incl. primer & weather cote spary painting angle support with wall matching color as per direction of EIC.
i) 300x200x75x2.04mm (14SWG)"L" shaped angle structure length 500mm
ii) 200x150x75x2.04mm (14SWG)"L" shaped angle structure length 600mm
Supply and Laying of PVC/XLPE insulate Armoured Alluminium Cable in Existing Tray.
a) 4 core 70 sq mm
b) 4 core 50 sq mm
d)4 core 25 sq mm
Supply and Laying of PVC/XLPE insulate Armoured Alluminium Cable through existing tray as to GS
a) 4 core 70 sq mm
b) 4 core 50 sq mm
c)4 core 25 sq mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry and Finishing cable ends bysoldering with cable sockets and insulated tapes etc., includingsupplying sockets, soldering materials, tapes etc. and makingconnection to switch, BDB and BBC etc. of XLPE/PVC armoured cables as below :
a) 4 core 70 sq mm
b) 4 core 50 sq mm
c)4 core 25 sq mm
Straight through Jointing of cable of different size by compound kit including S&F ferrul, tapes and jointing materials (approved make)
i) 4 core 16-25 sqmm cable
ii) 4 core 70 sqmm cable
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25 mm size PVC rigid conduit 'FR' or (Precision make) incl. necy. fittings as required
a) 3x1.5 Sq mm
b) 2x6 + 1x4 Sqmm (for SPN DB)
Distn. wiring with 1.1KV grade single core stranded copper conductor PVC insulated and unsheathed copper wire (approved make as to EIC) in 40mmx20mm/20x20mm PVC casing and capping or 19/25mm dia 3 mm thick PVC regid pipe complete with all accessories etc. embedded in wall (for VTPN to TPN DB, TPN DB to SPN DB, TPN DB to A.C point and for separate 15A plug point/Computer point and running meter for seperate plug point, coridoor light etc.)
a) 3x1.5 Sq mm
b) 2x2.5 + 1x1.5 Sqmm (for Power plug & Computer points.)
c) 2x6 + 1x4 Sqmm (for SPN DB)
d) 4x10 + 2x4 Sqmm (for TPN DB)
Supply & Laying of multi core following sizes PVC insulated copper U/A 1.1 kv grade flexible cable as ph, N & earth partly through fixed cable tray and partly through fixed u-PVC rigid pipe making holes etc as necessary mending good damages and painting for connection from TPN DB to AC, Gyser and computer board.
i) 3 core 4sq mm (for AC & Gyser)
ii) 3 core 2.5sq mm (for computer and other power plug board)
S&F of required size solderless Cu socket of following Cu wires.
i) 6sq mm
ii) 4sq mm
iii) 10sq mm
iv) 2.5 sq mm
S&F 8 way Vertical TPN PBDB with 3 phase in coming & TP/SP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43 protection) (L&T/Siemens/ABB) double door comprising of neutral link incl. & provision for earthing attachment concealed in wall after cutting the brick wall and mending good the damages to original finish incl. interconnection with suitable size of copper wires and earthing attachment. Incoming-415V, 36KA, 125A,4pole MCCB ,----1no Outgoing- 415V, 10KA, 63A T.P MCB C curve, ----7 nos 230V,10KA, 40A S.P MCB C curve,----3nos.
Supplying and fixing 415 V, 16-32A per way, TPN MCBDB with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (make-L&T/Siemens/ABB) as to GS.
a)6way, 63A FP isolator, & 18 nos. SPMCB
Supplying and fixing 250 V, 6-10A per way, SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (make-L&T/Siemens / ABB) as to GS
a) (2+10) way, 40A DP Isolator 1 no, 10 nos. SPMCB
Distn. wiring in 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (approved make) in suitable size PVC casing- capping (precision make) complete with all accessories on surface in wall to light/fan/call bell points with modular type switch (make approved by EIC, ) fixed on metal flush box (modular type switch board) 8 or 9/12 module moduler white surrounds on wall incl. necy. connections and making earthing attachment flushed in wall incl. mending good damages to original finish
a)Avg. run 10mtr
Supplying and fixing following dia. u-PVC Rigid conduit (make approved by EIC) including necessary fittings(shaddles, steel screw (2") bend etc as required for laying outer wall
Supply & Fixing of Testing Joints by 25 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Earthing with 50 mm dia(TATA medium) GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for earth strip and u-PVC pipe installation, per storey of building per vertical run
Labour Charges for uplifting and relaying the different sizes old cables into newly installed tray throughout the cornice of main building as per direction of EIC
Dismantling of old damaged cables, PVC covers and Earth continuty Wire/Strip and submitting the same at Section Store(within 1KM) as per direction of EIC after checking the cables and mending good the damages.
Part B: Telephone and Broadband Line. Supply & fixing of 5 pair 0.5mm PIJF cable Finolex/Delton through 3/4'' PVC rigid conduit Precession medium gauge pipe incl.all accessories
Supply & fixing of 10 pair 0.5mm PIJF cable Finolex/Delton through 3/4'' PVC rigid conduit Precession medium gauge pipe incl.all accessories
Supply & fixing of 20 pair 0.5mm PIJF cable Finolex/Delton through 3/4'' PVC rigid conduit Precession medium gauge pipe incl.all accessories
Supply & fixing of 10 pair special type metal AD box with terminal strips, termination of cable pair including all accessories.
Supply & fixing of 20 pair special type metal AD box with terminal strips, termination of cable pair including all accessories.
Supply & fixing of 50 pair special type metal AD box with terminal strips, termination of cable pair including all accessories.
Supply & fixing of 100 pair special type metal AD box with terminal strips, termination of cable pair including all accessories.
800 pair house pillar ICI paint one coat primer and two coat Firoza Blue inside and outside painting changing of terminal strips, jumpering, dressing termination of cable pair etc.
Old Cable jointing perpose(4 Joint) Joint Kit(TSF) papers sleeve, jelly PVC tape, Salimar tape, jute, kerosin oil etc.
Old Telephone cable 200 pair, 100 pair, 50 pair, 20 pair, 10 pair uplift and place on the rake.
Part C: TV Signal Cable Line. Supplying and Fixing of 4 way Optical Receiver Node with making suitable arrangement including necessary connection and testing as required as per direction. (Make: DBC/Optic Vison/Alcom)
Supply and installation of CATV Signal Amplefier with making suitable arrangement including necessary connection and testing as required as per direction (Make: DBC/Optic Vison/Alcom)
Supplying and Laying of RJ-6 Coaxial TV signal cable on wall through existing Cable tray/pipe/Casing to different suites and offices using existing scaffolding as per direction. (Copper)(Make: Finolex/DBC/JVP/)
Supplying and Fixing of Coaxial Splitter including necessary connection and testing as required (Make: DBC/Solid/MG/Optivision)
Supplying and Fixing of Coaxial Cable Connector (Approved make)
Supplying and Fixing of Jointer (Approved make)
MONDAL ELECTRIC CO.
STANDARD BUILDERS
MITRA ELECTRONICS
Netaji Engineers CO-Operative Society Ltd.
S. A. ENTERPRISE
ALPHA ELECTRICALS
Electromech Engineers Co-Operative Society Ltd.
stage.html
html • 0.06 MB
technical_546001.pdf
PDF • 0.04 MB
techsummary_546001.pdf
PDF • 0.04 MB
finance_546001.pdf
PDF • 0.04 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_546001.pdf
PDF • 0.07 MB
Prov.NIQ-03-2020-21.pdf
PDF • 0.27 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .