Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAdmitted-Fee/PreQual/Technical/Finance STATION ROAD KHALARI PO PS KHALARI DIST RANCHI 829205 | KHALARI | RANCHI | JHARKHAND | 829205 | ₹2.9 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹2.9 L+₹2,613.97 (0.90%)Admitted-Fee/PreQual/Technical/Finance | ₹2.9 L+₹2,613.97 (0.90%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹3.8 L+₹93,901.71 (32.3%)Admitted-Fee/PreQual/Technical/Finance AT P O RAHAM P S TANDWA PIN 825321 | RAHAM | CHATRA | JHARKHAND | 825321 | ₹3.8 L+₹93,901.71 (32.3%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹4.2 L+₹1.3 L (45.7%)Admitted-Fee/PreQual/Technical/Finance 51 RAHAM RAHAM TANDWA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | ₹4.2 L+₹1.3 L (45.7%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹4.4 L+₹1.4 L (49.7%)Admitted-Fee/PreQual/Technical/Finance | ₹4.4 L+₹1.4 L (49.7%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | M/S BABA & CO L4 | M/S HOPE ENTERPRISES L2 | M/s KASHYAP ENTERPRISE L3 | M/s DILIP ELECTRICAL WORKS L1 | M/S ELECTRO COOL L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling Group A as required For damaged wiring in SISF camp. | 60 | Point | 506.85 ₹30,411 | 271.53 ₹16,291.8 Lowest | 460.35 ₹27,621 | 315 ₹18,900 | 520.8 ₹31,248 |
| 2.00 | Wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required. Group A for extension of as required for Area quality building rooms and sisf camps. | 45 | Point | 879.63 ₹39,583.35 | 362.05 ₹16,292.25 Lowest | 798.93 ₹35,951.85 | 550 ₹24,750 | 903.84 ₹40,672.8 |
| 3.00 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required for changing of damaged boards in sisf camp. | 30 | Nos | 316.1 ₹9,483 | 543.07 ₹16,292.1 | 287.1 ₹8,613 | 203 ₹6,090 Lowest | 324.8 ₹9,744 |
| 4.00 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A plano type .as required for extension of point wiring | 15 | Nos | 440.36 ₹6,605.4 | 1,086.14 ₹16,292.1 | 399.96 ₹5,999.4 | 275 ₹4,125 Lowest | 452.48 ₹6,787.2 |
| 5.00 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit | 210 | Mtr. | 210.37 ₹44,177.7 | 77.58 ₹16,291.8 Lowest | 191.07 ₹40,124.7 | 140 ₹29,400 | 216.16 ₹45,393.6 |
| 6.00 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire. | 60 | Mtr. | 307.38 ₹18,442.8 | 271.53 ₹16,291.8 | 279.18 ₹16,750.8 | 195 ₹11,700 Lowest | 315.84 ₹18,950.4 |
| 7.00 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC Insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth | 30 | Mtr. | 407.66 ₹12,229.8 | 543.07 ₹16,292.1 | 370.26 ₹11,107.8 | 254 ₹7,620 Lowest | 418.88 ₹12,566.4 |
| 8.00 | Providing and fixing 125 A rating and breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. | 1 | Each | 7,828.38 ₹7,828.38 | 16,292.08 ₹16,292.08 | 7,110.18 ₹7,110.18 | 5,171 ₹5,171 Lowest | 8,043.84 ₹8,043.84 |
| 9.00 | Providing and fixing 250 A rating and breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.for solar power isolation, Dg power isolation. | 1 | Each | 16,730.41 ₹16,730.41 | 16,292.08 ₹16,292.08 | 15,195.51 ₹15,195.51 | 12,500 ₹12,500 Lowest | 17,190.88 ₹17,190.88 |
| 10.00 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V,TPN MOBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer)as required. (Note:Vertical type MOB TPDB is normally used where 3 phase outlets are required)4 way(4+12), Double door | 1 | Nos | 7,132.96 ₹7,132.96 | 16,292.08 ₹16,292.08 | 6,478.56 ₹6,478.56 | 4,600 ₹4,600 Lowest | 7,329.28 ₹7,329.28 |
Tender Value
₹4.6 L
EMD Value
₹5,730
Closing Date
7 Aug 2026, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area Bachra, 829201.
Repairing and extension of point wiring of SISF camp chamatu, SISF camp saradhu,Sisf camp Amarwadih with flood light fixing and Area quality office building for installing bomb calorie meter at chamatu under Magadh-OCP M-S Area
2026_CCL_362362_1
GM(MS)/SO(EnM)/e-NIT/26-27/24
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Office of the Project Officer Magadh OCP, M-S Area
Please Refer NIT
3 documents required · 3 mandatory
₹5,730
8 Aug 2026
27 Jul 2026
8 Aug 2026
28 Jul 2026
7 Aug 2026
28 Jul 2026
28 Jul 2026 - 4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling Group A as required For damaged wiring in SISF camp. | 60 | Point | 3,880 | ₹2,32,800 |
| 2 | Wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required. Group A for extension of as required for Area quality building rooms and sisf camps. | 45 | Point | 3,880 | ₹1,74,600 |
| 3 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required for changing of damaged boards in sisf camp. | 30 | Nos | 3,880 | ₹1,16,400 |
| 4 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A plano type .as required for extension of point wiring | 15 | Nos | 3,880 | ₹58,200 |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit | 210 | Mtr. | 3,880 | ₹8,14,800 |
| 6 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire. | 60 | Mtr. | 3,880 | ₹2,32,800 |
| 7 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC Insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth | 30 | Mtr. | 3,880 | ₹1,16,400 |
| 8 | Providing and fixing 125 A rating and breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. | 1 | Each | 3,880 | ₹3,880 |
| 9 | Providing and fixing 250 A rating and breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.for solar power isolation, Dg power isolation. | 1 | Each | 3,880 | ₹3,880 |
| 10 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V,TPN MOBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer)as required. (Note:Vertical type MOB TPDB is normally used where 3 phase outlets are required)4 way(4+12), Double door | 1 | Nos | 3,880 | ₹3,880 |
stage.html
html • 0.02 MB
finance_375261.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_375261.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .