Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC 56 LALKURTI BARA BAZAR MEERUT CANTT UP 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Being L1 accepted | |
| 2 | L2₹21.7 L+₹1.3 L (6.41%)Rejected-Finance 96 4 PHOOL BAGH COLONY MEERUT 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-Finance Rejected due to not being L1 | |
| 3 | L3₹22.9 L+₹2.4 L (12.0%)Rejected-Finance 11 BHAVESH KOTHARI 11 MAIN STREET MHOW INDORE MADHYA PRADESH 453441 | INDORE | MADHYA PRADESH | 453441 | L3 | Rejected-Finance Rejected due to not being L1 | |
| 4 | L4₹23.9 L+₹3.5 L (17.1%)Rejected-Finance C 92 JAIN NAGAR RAILWAY ROAD MEERUT UP | L4 | Rejected-Finance Rejected due to not being L1 | |
| 5 | L5₹24.7 L+₹4.2 L (20.7%)Rejected-Finance 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance Rejected due to not being L1 |
Tender Value
₹38.8 L
EMD Value
₹77,500
Closing Date
15 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt
SPL REPAIR TO 02 NOS MAG BLDG NEAR SHIVAJI LINE OF 6 RAJPUT UNDER AGE B/R-IV OF GE (SOUTH) MEERUT CANTT
2023_MES_615508_1
GE/MRT/S/8086/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
GE (South) Meerut
₹77,500
Yes
23 Nov 2023
24 Aug 2023
18 Sept 2023
25 Aug 2023
15 Sept 2023
8 Sept 2023
Amount
Supply & fix in repairs steel windows or ventilators fixed type, complete all as specified & directed.
S&F Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples, complete all as specified & directed.
Hacking out old broken glass ( any thickness, size, quality or description) from metal/wooden frames fixed with pin, beading or oil putty complete all as specified & directed.
S&F 3 mm thick, plain sheet glass ordinary quality and glazing with oil pane putty in squares not exceeding 0.5 Sq. m in each pane. Complete all as specified & directed.
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as per specified and directed.
M&L for 50mm thick PCC 1:2:4 type B-0 (12.5mm graded aggregate) as in sub base floor etc complete all as specified & directed.
M&L Machine cut kota stone slab flooring 20 to 25mm thick jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20mm thick screed bed in cement mortar 1:6. Complete all as specified & directed.
M&L Machine cut kota stone slab 20mm to 25mm thick as on vertical surface such as skirting/Dados laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over & including 15mm thick rendering in cement mortar 1:6. Complete all as specified & directed.
M&L PCC 1:3:6 type C1 (using 20 mm graded aggregate) as in bed block, copings, kneelers, apex stones, bed plates, water troughs and the like including cutting into bricks of stone wall as reqd for inserting hold fasts complete all as specified & directed.
M&L 75 mm thick PCC 1:3:6 type C1 (20 mm graded stone aggs) as in plinth protection, path including finished surfaces even and smooth without using extra cement complete all as specified & directed.
Dismantling Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets complete all as specified & directed.
Supply and fix false ceiling with 9mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified & directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified & directed.
Material and labour for brick work with fly ash bricks of straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified & directed.
Ditto as above item No 14.00 but herein except fly ash bricks complete all as specified & directed.
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on bricks or concrete surface, finished even and smooth without using extra cement complete all as specified & directed.
M & L for preparation of new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
M & L for preparation of old plastered or unplastered surfaces of wall and applying two coat of white wash complete all as specified and directed.
M&L preparation of New wall plaster surfaces and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed
M&L preparation of old wall surfaces including complete removal of existing treatment and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of new or previously untreated steel & iron surfaces of any description, not otherwise described over 10 cm width or girth and apply two coat of synthetic enamel paint over over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel & iron surfaces of any description, not otherwise described over 10 cm width or girth and apply a coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old wooden surface of any description, not otherwise described over 10 cm width or girth and apply a coat of synthetic enamel paint complete all as specified and directed.
Dismantling of Asbestos cement / Fiber (corrugated,semicorrugated, etc.) sheet any description as in roof covering incl ridge and removing from site complete all as specified & directed.
M&L Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding / ridges, fixed with self tapping screws complete all as specified & directed.
S & F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified & directed.
S&F MS flat iron as in wind ties for roof cutting tops to shape as directed, drilling holes flat iron fillets including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290-0 Gde E-165. Complete all as specified & directed.
Material & labour Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface, laid over and including 15mm thick screed bed of cement mortar (1:6) including dismantling of old unserviceable tiles complete all as specified & directed.
Material & labour for Glazed ceramic tiles in vertical surfaces 350x250mmx7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing work over and laid over and including 10mm thick rendering in Cement mortar 1:4 including dismantling of old unserviceable tiles complete all as specified & directed.
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm PVC sheet reinforced suitable for solid PVC door suppling & fixing in opening, complete all as specified & directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, & joined together with solvent cement, in the frame at site as per specification & drawing.
S&F 250mm size Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as specified and directed.
S&F Stainless steel butt hinges 150 mm in size heavy weight, cold rolled mild steel, fixed with screws or with welding to existing frames, ISI marked, complete all as specified & directed.
S&F barrel tower bolts 200mm of aluminium, anodized extruded section and fixed, 200 mm long, dia of bolt not less than 12 mm, ISI marked, complete all as specified. all as specified and directed.
S&F Bow handle aluminium anodized of size 150 mm, ISI marked, complete all as specified. all as specified and directed.
Taking down chowkhats or frame exceeding 1.5 Sq. m but not exceeding 4 Sq. m each with shutters without taking off shutters from the frame, complete all as specified & directed.
S&F in repair Glass Corner Shelf fitted in wall with screws complete all as specified and directed
Supply & fix 15 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including Taking up or down GI steel tubing, testing complete all as specified & directed.
Supply & fix 20mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including Taking up or down GI steel tubing, testing complete all as specified & directed.
Supply and fix in repair PVC Pipes single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc. 75mm bore as in waste and rain water pipes complete all as specified & directed.
Supply and fix in repair PVC Pipes single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc. 110 mm bore including bend, tee etc or other fittings as requiredas in waste and rain water pipes complete all as specified & directed.
S&F in repair PVC vent Cowl 110 mm complete all as specified and directed.
S&F in repair 15mm bore pillar tap, long shank, swan neck, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts complete all as specified & directed.
S&F in repair 15 mm bore bib tap long body chromium plated, cast copper alloy, with crutch or butterfly handle, flange, screwed down for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repair chromium plated angle stop valve incl flange, any description, suitable for 15 mm bore pipe,complete all as specified & directed.
S&F in repair vitreous china squatting pan Orissa pattern, size 580 x 440mm, white, with integral footrest, including flushing cistern & flush pipe fixed as in repair with ‘P’ or ‘S’ trap, including making good the disturbed surfaces and to match with existing surface. Complete all as specified & directed.
S&F in repair PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including 32mm dia PVC long bend for squat pattern etc , set with concrete and making good to floor. Complete all as specified & directed..
S&F in repair Vitreous China wash basin, white, flat back, size 550 x 400 mm, including fixing acessories like galvanised brackets & rag bolts,32 mm CP waste coupling complete all as specified & directed.
Supply & fix in repairs chromium plated shower roses with swivel joints of 75mm size complete all as specified & directed.
Supply & fix in repairs PVC connections of 450mm long Make suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
Supply and fix in repairs PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed.
S&F in repair CP towel rail brass 20mm dia 600mm long CP finish complete all as specified & directed.
Supply & fixing rotational moulded polyethylene water storage tanks 1000 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings all as specified including 20 mmbore PTMT float valve with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 140gms), including dismantling existing water tanks complete all as specified & directed.
S&F in repair Gun metal globe or gate valves with Iron wheel head screwed both ends for iron pipe 15 mm dia. Complete all as specified & directed.
S&F in repair Gun metal globe or gate valves with Iron wheel head screwed both ends for iron pipe 20 mm dia. Complete all as specified & directed.
Supply & fix in repairs steel C.P. grating 100/125 mm dia waste pipe hole fitted as required at site complete all as specified & directed.
S&F in repair 15 mm bore concealed stop cock, chromium plated, cast copper alloy, screwed down with crutch or butterfly handle screwed both ends, complete all as specified & directed.
S&F in repair fency type CP brass soap dish complete all as specified & directed.
S&F in repair PTMT shelf 450 mm x 124 mm any colour with brass chromium plated screws & PVC rawl plugs (Minimum weight 300 gm) Complete all as specified & directed.
M&L in repair PVC SWR floor trap, with grating including joining to waste pipe fixed in cement concrete type B-1 (1:2:4) 100 mm dia Complete all as specified and directed.
M&L for Roof trusses (framed), trusses purlins, crane gantries, rail and fastneing and heavey bracket framing (beam,tee,angle,channel of flate sections) including distance piece including butt weldeding conforming Fe-410-W (gde-E250 Quality A) complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified & directed.
Returing and filling in layers nexc 25 cm incl watering and well running complete all as specified & directed.
Removal of surplus spoil upto a distance n. exc 50 meter complete all as specified & directed.
M&L Concrete bed to drain pipes 150mm, including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC(1:4:8) Type D-2. Complete all as specified & directed.
M&L Slat-glazed stoneware drain pipes 150 mm dia laid in trenches and jointed including dismantling old SGSW pipes of any size any type complete all as specified & directed.
M&L Cement concrete in foundations, filling and mass-concrete in PCC 1:4:8 Type D-2 (using 40 mm graded stone aggregate). Complete all as specified & directed.
M&L rendring 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even & smooth using extra cement complete all as specified & directed.
M&L PCC(1:3:6) type C1 (using 20mm well graded crushed stone aggregate) as in benching to man hole complete all as specified & directed.
M&L for construction of Septic tanks , exc in ordinary soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame vvent shaft and sludge chambers etc complete for 25 users. Complete all as specified in TD-217 sheet 1/7 to 7/7 and as directed.
M&L for construction of Soakage well of size 1.8M dia & 3.00M depth, excavated in ordinary soil, foundation in PCC1:3:6, wall of Honey combed and solid in M-25 RCC, including intercepting chamber, screen chamber brick work in CM 1:4, RCC cover slab in M-25 RR masonry/ filling with brick bats, in TD - 309 Srl No 1/4 to 4/4. Complete all as specified & directed.
Dismantling Chain link fencing of any type.Complete all as specified & directed.
Dismantling posts and struts (wood, steel or RCC) any section, including taking out embeded portion and making good disturb ground complete all as specified & directed.
S&F Mild steel angle iron post as in fencing posts, cut to length, drilling holes, welding and embedded in concrete complete, including preparation of new or previously untreated steel & iron surfaces of any description, not otherwise described over 10 cm width or girth and apply two coat of synthetic enamel paint over over a coat of red oxide primer complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc. incl provision of binding wire. Complete all as specified & directed.
Supply only chain link MS galvanised fencing, heavy zinc coated (Hot Dip) of 4mm nominal dia of wire and mesh of size 100mm x 100mm conforming to IS: 2721-2003 complete all as specified in clause 10.34 on page 214 & 215 of MES SSR - 2009, Part-I and as directed.
S&F 40x5 mm thick flat iron as in fastening of chain link fencing fixed to nuts and bolts including holes complete all as specified & directed.
S&F mild steel screw, nut & bolts including washers (machine made) with hexagonal or square heads at one end and screwed complete all as specified & directed.
S&F Mild Steel TMT round or square bar 10mm dia & over for straining, in available length, cut to length, bent to shape requqired Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia bars at 75 mm spacing complete all as specified & directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified & directed.
M&L RCC type B1 (1:2:4) (nominal mix) (using 20 mm well graded crushed stone aggregate) in Columns, pillars, piers, posts, post holes and struts etc including necessary formwork Complete all as specified and directed.
Surface excavation not exc 30cm deep but averaging 15cm deep and getting out soft / loose soil complete all as specified & directed.
M & L for broken bricks Hardcore of guage n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface. Complete all as specified & directed.
.M&L PCC (1:4:8) type D-2, 100 mm thick (using 40 mm graded stone agg) as sub base finished even & fair complete all as specified & directed.
M&L PCC (1:2:4) type B-1, 75 mm thick (using 20 mm graded stone agg) as sub base finished even & smooth complete all as specified & directed.
M&L coloured chequred cement concrete tiles 30cm x 30cm x 25mm thick set joined and pointed in neat cement slurry in floors with grey and pigments laid over and including Screed bed 15 mm thick in CM 1:4 for Laying floor finishes (including dismentling of old unserviceable tiles) complete all as specified and directed.
M&L Precast cement concrete block as in Kerb stone with Type B1 1:2:4 (20mm graded aggregate) solid blocks, exc. 10cm in width and setting in cement mortar 1:4. Complete all as specified & directed.
Taking down carefully any type of battens or conduit point wiring with conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existingcomplete all as specified & directed.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 PVC insulated, unsheathed copper conductor cable in and including concealed in stove enamelled steel conduit of 20 mm dia or higher, medium grade complete with and including all stove enamelled conduit accessories / fittings, brass screws, washers etc, for fitting of flame proof switches and accessories through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing and including continuous earth wire of size 1.0 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the following One Tube light/bulb/fancy/bell/street light point controlled by one, one way switch 05 / 06 Amps. :-
S&F in repair switch flame proof rotary type with terminal box in LM6, 16 Amps single pole 250 volt. Complete all as specified & directed.
S&F in repair LED wall mounted flame proof light fitting 30 Watt, 230 V, electronic driver high transculent frosted diffuser complete with all accessories internally prewired complete all as specified & directed.
S&F in repair LED building security light fitting flame proof 1x35 Watt luminaries with die cast aluminium housing comprising epoxy poweder coated enclosed with glass cover in frame with high power LED white lamp of capacity 35 watt including making connections with flexible twisted copper wire of size 23/0.000076 with security light bracket fitting made out of 32 mm dia GI pipe medium grade upto 0.9 Mtr long including all acceessores. Complete all as specified & directed.
S&F in repair flame proof sheet metal enclosure for DB's with IP 66 protection 200 amp rated insulated bus bar, shrouded neutral bar, earth bar, blanking plate, cable ties & circuit identification labels 240 volt SPN 12 way. Complete all as specified & directed.
S&F in repair in repair MCB SP, AC, 240 volts of 06 to 40 Amps, C curve,Optipro 10 kA, complete all as specified & directed.
S&F in repair in repair MCB SPN, AC, 240 volts of 40 Amps,C curve,Optipro, 10 kA, complete all as specified & directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion including dismantling old unserviceable earthing of any size any type complete all as specified & directed.
Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 16 Sqmm 2.0 core armoured, PVC sheathed with aluminium conductor heavy duty including takin down old unserviceable cable of any type of description. Complete all as specified & directed.
Supply / laying and fixing 50mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed.
M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling andhard punning complete all as specified & directed.
Material and labour for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed.
Material & labour for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with copper earth plate electrode 60cmx60cmx3.15mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No. 5 of SSR part I connecting to main test point including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40x40x5mm frame for pit cover complete all as specified and directed.
M&L for air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F aluminium strip 25x3.15mm with saddle and fixing screw etc for roof conductor and dodw conductores above ground level complete all as specified and directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilling and screw incl 03 nos 8mm dia 25mm long hex, head screw. LED wall mounted flame proof light fitting 30 Watt, 230 V, electronic driver high transculent frosted diffuser complete with all accessories internally prewired complete all as specified and directed.
Supply / laying and fixing 80mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed.
Material and labour for Cement concrete 1:2:4, type B2 (using 20mm crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Material and labour for Cement concrete 1:3:6, type C2 (using 20mm crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Supply and fix ACSR conductors (Weasel). Complete all as specified and directed.
Tayal Builders
B.K.construction
Rajneesh Jain
SA construction co.
AEGIS INTERNATIONAL
High Tech Metal India
M/S Praveen Kumar and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .