Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC H NO G162 SECTOR 10 FARIDABAD 121006 | FARIDABAD | FARIDABAD | HARYANA | 121006 | ₹1.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.7 L+₹3,727.01 (2.20%)Rejected-AOC 2 11 DHAJU FARIDABAD HARYANA 121004 | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹1.7 L+₹3,727.01 (2.20%) | L2 | Rejected-AOC L2 |
Tender Value
₹1.7 L
EMD Value
₹3,380
Closing Date
16 Jan 2026, 5:00 pmClosed
Sandeep Dahiya
Horticulture Faridabad
HEW 142 Providing and fixing of MS angle and barbed wire fencing in HSVP of Nursery Sector 17 Faridabad.
2026_HBC_496008_1
2026D66487CF 9104 49AF BD28 296BBC484D60264HSV
Open Tender
Civil Works
Works
30 days
Faridabad (MC)
as per dnit
2 documents required · 2 mandatory
₹250
Yes
₹3,380
Yes
30 Jan 2026
9 Jan 2026
19 Jan 2026
9 Jan 2026
16 Jan 2026
9 Jan 2026
9 Jan 2026 - 11 Jan 2026
[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
[6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.
[6.8.2]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 2. 40mm thick
[7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand)
analysis rate for Prov. and fixing of 600mm Dia Centrina wire and Nos. horizontal wire complete in all respect at site of work.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
BOQ_574509.xls
BOQ • 0.33 MB
EMF366Z148064.pdf
Additional Documents • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .