Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAccepted-AOC | ₹5.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.6 CrRejected-Finance | ₹5.6 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹5.8 CrRejected-Finance | ₹5.8 Cr | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | M/S BABA TRADERS L2 | M/s AJAY KUMAR SAHI L3 | M/S DEEPENDRA PAL THEKEDAR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavaton work in excavation. Dry Earthwork in foundation building work including lead up to 30M and lift upto 1.5M and its disposal. As directed by Engineer-in charge. All kinds of soil | 1,402.99 | CUM | 70 ₹98,209.30 | 70 ₹98,209.30 | 70 ₹98,209.30 |
| 2.00 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 70.00 Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distance of 50m out side the periphery of area cleared. under floor Local Sand. | 41.65 | CUM | 1,200 ₹49,980 | 1,550 ₹64,557.50 | 1,500 ₹62,475 |
| 3.00 | Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering.
Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P.
(b) mechanical mixing + Labour cost. (M15) (1:2:4) | 54.73 | CUM | 7,000 ₹3.8 L | 8,000 ₹4.4 L | 7,000 ₹3.8 L |
| 4.00 | Cement concrete with stone grit in RCC work excluding all cost of material but inclusive of labour and T&P and also excluding centering, shuttering and reinforcement.
(b) mechanical mixing and Extra for mechanical vibration with 1% water charges.
Total Concrete work for structure. (M25) (1:1:2) | 656.63 | CUM | 9,100 ₹59.8 L | 9,250 ₹60.7 L | 8,500 ₹55.8 L |
| 5.00 | Thermo-Mechanically Treated bars work such as in reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. | 523 | QUINTELS | 6,700 ₹35.0 L | 6,400 ₹33.5 L | 6,000 ₹31.4 L |
| 6.00 | Backfilling the footings, Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty.
Upto 10 km extra lead. | 861.02 | CUM | 275 ₹2.4 L | 250 ₹2.2 L | 300 ₹2.6 L |
| 7.00Centering and shuttering including strutting, propping etc. and removal of form for | ||||||
| 7.01 | Foundations, footings, bases of columns, etc. for mass concrete | 547.34 | SQM | 250 ₹1.4 L | 240 ₹1.3 L | 250 ₹1.4 L |
| 7.02 | Suspended floors, roofs, landings, balconies and access platform. | 1,604.59 | SQM | 600 ₹9.6 L | 490 ₹7.9 L | 525 ₹8.4 L |
| 7.03 | Lintels, beams, plinth beams, girders, brassumers and cantilevers | 1,031.55 | SQM | 475 ₹4.9 L | 410 ₹4.2 L | 500 ₹5.2 L |
Tender Value
₹6.7 Cr
EMD Value
₹13.4 L
Closing Date
5 Mar 2026, 3:00 pmClosed
S.E, Irrigation Construction Circle, Basti
S.E, Irrigation Construction Circle, Basti
Construction work of Office Building of Chief Engineer Level-1(East) and Chief Enginner (Gandak) Located in Saryu Nahar Colony District Gorakhpur.
2026_UPIDC_1119556_1
10/S.E/2025-26
Open Tender
Civil Works - Buildings
365 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹9,884
₹13.4 L
23 Mar 2026
23 Feb 2026
5 Mar 2026
23 Feb 2026
5 Mar 2026
24 Feb 2026
Excavaton work in excavation. Dry Earthwork in foundation building work including lead up to 30M and lift upto 1.5M and its disposal. As directed by Engineer-in charge. All kinds of soil
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 70.00 Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distance of 50m out side the periphery of area cleared. under floor Local Sand.
Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering. Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P. (b) mechanical mixing + Labour cost. (M15) (1:2:4)
Cement concrete with stone grit in RCC work excluding all cost of material but inclusive of labour and T&P and also excluding centering, shuttering and reinforcement. (b) mechanical mixing and Extra for mechanical vibration with 1% water charges. Total Concrete work for structure. (M25) (1:1:2)
Thermo-Mechanically Treated bars work such as in reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.
Backfilling the footings, Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty. Upto 10 km extra lead.
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, brassumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls (Under 20cm wide)
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 sand (zone- III) derieved from natural source : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Brick work in 1:4 cement mortar upto 3M lift and 60M lead of materials including scaffolding.
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. AT PORTICO ONLY
12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall.
15 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On rough surface of wall.
Floor Finishing or Preparation at Ground Floor
Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty. Upto 15km extra lead. (soil filling from N.G.L to F.F.L)
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 70.00Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distance of 50m out side the periphery of area cleared. under floor Local Sand.
Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering. Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P. (b) mechanical mixing + Labour cost. (M15) (1:2:4)
Providing and injecting chemical emulsion for preconstructional antitemite treatment and creating a chemical barrier under and around the column pits/wall trench/basement excavation top surface of plinth filling/junction of wall and floor along the external perimeter/building expansion joints, surrounding of pipes and conduits etc. complete/plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981) aldrine emulsifiable concrete or any other approved material such as hephachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonry & foundation 5 litres per sq.m. (2) back fill in immediate contact with foundation 7.5 litre per sq.m (3) treatment of top surface of plinth filling 5 liters per sq.m (4) treatment of soil along external parameter of building 7.50.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.(1 M WIDE)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
White washing with lime on undercoated wall surface two coats, to give an even shade including thoroughly brooming the surface, to remove all dirt, dust, mortar drops and other foreign matter.
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. (exterior+interior)
Doors & Windows Parts
Providing and fixing aluminium tower bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(200x10)
Providing and fixing aluminium tower bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(100x10)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(250x16)
Providing and fixing aluminium handles, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(100 mm)
Providing and fixing aluminium hanging floor door stopper, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(single)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid separately). (Sal Wood)
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing and fixing M.S. Grill of required pattern in frame of windows etc. with MS flats, square or round bars etc. including priming coat with approaved steel primer all complete. Fixed to openings/wooden frames with rawl plugs screws etc. Window grill complete.
PVC door inside Toilet
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in-Charge.
5 mm thick solid foam PVC panel of required size with moulded/ extruded beading of appropriate design shape and size as per manufacturer’s specifications ( to secure the panel insert tight in place within the style and rails of shutter) matching the colour and shade of shutter frame. Non decorative type.
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire dia 0.5mm and average width of aperture 1.4mm in both directions for doors, windows and clerestory windows with necessary screws: 35mm thick shutters
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35mm thick door panel
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire dia of 0.63mm all complete. With second class teak wood beading 62x19 mm.
Providing and fixing panelled or panelled and glazed shutters for door, windows and clerestory window , fixing butt hinges of required size with necessary screw, excluding panelling which will be paid for separately, all complete as per direction of engineer-in-charge. 30mm thick window panel
Providing and fixing ISI marked alumunium butt hinges anodised (anodic coating not less than Grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screw etc. complete.
100X63X3.2 (Doors)
75X45X3.2 (Windows)
Providing and fixing Chromium Plated brass casement window fastener with necessary screws etc. complete. 200mm wighting not less than 240 gms
(A) Applying ready mix primer including cost of material. b) Wood surface (Rates inclusive of repairing surface, preparing of surface by thoroughly cleaning oil, grease, dirt and other foreign material and scour with wire brush etc.
(A) Painting 1st coat over priming coat (but excluding cost of priming coat) on steel and other metal surface including cleaning the surface of all dirt, dust and other foreign matter, sand papering and stopping including cost of materials labour Tools and Plants etc. as required for proper completion of work. Paint shall be used as per standard I.S. specification. (B) Same as in Item No. 2 (A) above but on new wood surface.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).(Stair's Railings)
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Stone tile work for wall lining up to 10m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. Granite stone of any colour and shade.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.(1.2mX2.1m)
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks. (Partition wall inside wash room)
P/F European type white glazed earthen wire W.C. pan (Indian make) of approved quality ISI marked Bakelite seat cover & lid with C.P. brass hinges and rubber buffers.
P/F 100mm size ‘P’ or ‘S’ trap for water closed squatting pan including jointing the trap with the pan and pipe in cement mortar 1:1 (1 Cement: 1 Fine sand)
P/F 10 lit. acrylic/PVC flushing cistern with C.I. or M.S. bracket complete with fitting such as Symphonic arrangement, 15mm normal size brass valve with polythene float, C.P. brass handle, unions & coupling for connections with inlet, outlet and overflow pipes, 40mm dia P.V.C. flush band, including cutting holes in wall and making good the same and connecting the flush band the same and connecting the flush band with cistern and closest.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing Salem Skinless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board
510x1040 mm bowl depth 200 mm
P/F C.P. brass angle valve for cistern, wash basin Geyser etc. 15mm nominal hole size including cost of all materials, labour T&P etc.
P/F 15mm nominal hole size C.P. brass pillar cocks.
P/F white vitreous china flat back urinal size 580X380X350 mm with 5 lit, P.V.C. flushing cistern, flush pipe, C.I. trap and grating complete in all respect.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
P/F 600X400mm leveled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestors sheet ground fixed to wooden cleats with C.P. brass screws and washers.
P/F C.P. Brass toilet paper holders including cost of all materials, labours T&P etc.
P/F in position 100mm dia C.I. Nahani trap with hinged perforated cover complete with gasket and chaulked joints, including making necessary chases and hole in floor and walls and repairing the same to the original conditional completed.
Providing laying & fixing in position salt glazes S.W. full round pipe, I.S. 651 (Grade-A) with 1:2 cm with spun yarn or gasket laid underground over 15cm CC 1:4:8 and encased in proper gradient including excavation of trenches upto 2m depth. (BOTH CE1 + CE2)
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.100 mm inlet and 100 mm outlet
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
25mm nominal dia Pipes
50mm nominal dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Fixing 15mm PVC connection, heavy quality with brass Union including supply of all materials, labour T&P etc. required for proper completion of the work.
30 cm length
20 mm nominal bore
P/F copper alloy bib cock IS: 781-1977 complete with all materials
Making khurras 45×45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (BOTH CE1+CE2)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (BOTH CE1+CE2)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler(BOTH CE1+CE2)
Shoe plain (BOTH CE1+CE2)
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (BOTH CE1+CE2).
P/F square mouthed S.W. gully trap I.S. 651 (Grade-A) complete with C.I. grating brick masonry chamber and water fight C.I. cover frame 30X30cm size (inside) the weight of cover to be not less than 4.53 kg. and frame be not less than 2.72 kg. as per standard design including excavation etc. complete. (BOTH CE1+CE2)
P/F in position C.I. man hole cover and frames, IS:7267 embedded in R.C. cover and slab all exposed edges rounded and finished 1:3 cm etc. complete. (a) Fixing man hole cover light duty with frame 38kgs.
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m. (BOTH CE1+CE2) Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m. Pipes, cables etc. not exceeding 80 mm dia (TENTATIVE)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Dry Earthwork in foundation building work including lead up to 30M and lift upto 1.5M and its disposal. As directed by Engineer-in charge. All kinds of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and revelling the sub grade and disposal of surplus earth with lead upto 50 metres.
Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering. Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P. (b) mechanical mixing + Labour cost. (M15) (1:2:4)
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & atten over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking payer blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of payer blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineering Charge. 80mm thick Cement concrete payer block of M-30 grade with approved colour; design & pattern.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Wiring point for light fan with 1.5sq. mm P.V.C. insulated and P.V.C. sheathed T.R.S. single core cable with 1.5sq. mm. P.V.C. Insulated T.R.S. Single core cable earth continuity on teak wood Batten and surface type switch etc, complete in all respect.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep
Extra for fixing the louvers/shutters complete with frame for an exhaust fan of all sizes.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. AC
Supplying and fixing PVC batten/angle holder including connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA, TP MCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A MCB
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A RCCB
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Joining shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.
3-1/2 X 25 sq.mm
3-1/2 X 120 sq.mm
3-1/2 X 240 sq.mm
4 X 16 sq.mm (28mm)
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR Civil 2023 Item no. 10.18.)
Supplying and laying of aluminum conductor PVC sheathed cable 1100 Volts grouting with MS clamps of suitable size as directed in all respect. All mounting shall be properly connected with earth conductor by clamps but excluding cost of cable tray. (MV CABLE)
120 sq mm 3-1/2 core
240 sq mm 3-1/2 core
25 sq mm 3-1/2 core
16 sq mm 4 core
100 Amp. MCCB - 2 Nos.(CATA+CATB)
63 Amp. MCCB - 3 Nos.(CATA+CATB)
100 Amp. MCCB - 3 Nos.(CATA+CATB)
Supplying and fixing factory wire H.P.F. box type florescent tube light fitting suitable for 1X40 watt florescent tube complete, including tube etc. on surface complete in all respect of Philips/Bajaj/ G.E.C./Crompton make.
Supplying and fixing of 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing of brass batten/angle holder including connection etc. as per required
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of granular sub-base by providing closed graded material confirming to specification, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all lads and lifts, spreading in a uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory powered roller to achieve the desired density, complete as per specifications and direction of engineer-in- charge. With material confirming to grade (size range 75 mm to 0.075 mm) having CBR value - 30
Cement concrete with stone grit in RCC work excluding all cost of material but inclusive of labour and T&P and also excluding centering, shuttering and reinforcement. (b) mechanical mixing and Extra for mechanical vibration with 1% water charges. (200mm thick Concrete laying as rigid pavement) (M25) (1:1:2)
Providing and lying non pressure NP-4 class (heavy duty) RCC pipes including collers/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. 450 mm dia RCC pipes
Providing and lying non pressure NP-4 class (heavy duty) RCC pipes including collers/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. 600 mm dia RCC pipes
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supply & fixing of 7.0 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thick) having 3mm thickness with single arm bracket (1 Mr length) on RCC foundation including the cost of Each foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. @ 12M.
Supply & fixing of 7.0 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thick) having 3mm thickness with Double arm bracket (1 Mr length) on RCC foundation including the cost of Each foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Each and above Protection complete in all respect. CAT AAA
Supply and buying of 600mm x 600 mm x 6mm G.I. plate, vertically for earthing with its top at least 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8 to 108 WC G.I.wire in 15mm dia GI. pipe upto switch board (from apron to switch board the cost of G.I. pipe each and G.I. wire will be extra).30cm.square C.I. frame with hinged cover, masonary housing, alternate layers(of charcoal/coke and salt at least 150mm thick all-round etc. complete in all respects.
Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top. On surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size
size 10 sq mm x 2 core
size 16 sq mm x 4 core
Supply and fixing of brass nickel plated compression gland for pvc insulated & armoured served sheaththed underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable
size 10 sq mm x 2 core
size 16 sq mm x 4 core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for PVC insulated & armoured cable insulating with tape and making connection. Complete in all respect as per direction of engineer –in-charge. for cable
size 10 sq mm
size 16 sq mm
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) Trusses etc., Including cutting hoisting, fixing in position And applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.( All steel work for car parking+ solar)
Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty. Upto 10 km extra lead. (Total Landfill Volume calculated from drawing=4310CUM Deducting the Excavation for foundation from CE1 (245.85 CUM), CE2(223.51 CUM), Drainage, Sewarage, Boundary Wall & Car Parking =4310-245.85-223.51-245.3-270-361.6-36-20.74
Brick edging 7cm wide 11.4cm deep to plinth protection with bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement: 4 fine sand)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approves steel primer all complete (base +top plate + stiffener + purlin ) (Solar & car parking)
Structural steel work rebetted, bolted or welded in built up section, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (anchor bolt) for parking shed
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (All bends & tees shall be of factory built-in of same make as that of tray) 100 mm width X 50 mm depth X 1.6 mm thickness
P/F 3 phase 25KW GTI (DC TO AC converter )
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
P/F SOLAR panel 590 watt each
P/F Earthing kit (3 mtr copper binded rod, 1 mtr lightening arrestor and 15 kg chemical wire )
P/F Earthing wire from arrestor to ground (16mm )
P/F DC WIRE 10 mm
P/F DC DB (MCB+distribution box+FUSE 1000V 40KW) 3 phase
P/F AC DB (MCB+distribution box+FUSE 1000V 40KW) 3 phase
P/F NET Mitre
P/F Mc4 connector
P/F Anchor Bolt
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Providing and fixing ABC Stored Pressure type Fire Extinguisher bearing ISI Mark for Fighting ABC Class of Fire. The Extinguisher will be Manufactured Strictly as per BIS: 15683:2006 bearing ISI. mark. EN3 615 Approved Powder. ABC 87% MAP. Valve with below mentioned additional facilities a) In built NRV on valve to cross check internal pressure. b) Operating temperature marking on valve. c) Automatic safety release valve. d) Non Returnable Valve
Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 WAY
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia
32 mm dia
50 mm dia
100 mm dia
150 mm dia
200 mm dia
Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2.
Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45°C temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for
150 mm dia
100 mm dia
80MM dia
Providing and fixing and testing of Cast Iron Body Foot Valve for suction lines for each pumping sets all complete as specified and of sizes as under. 200mm
BUTTERFLY VALVE (manual) with CI body SS disk nitrile sheet and O-ring & PN16- pressure rated as specified.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
NON RETURN VALVE with dual plate of CI body SS plates vulcnized NBR seal flanged end and PN 16 pressure rating as specified.
100 mm dia
150 mm dia
Supplying, fixing, testing & commissioning of double flanged Sluice Valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
Y-STRAINER of Ductile CI body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation As specified
80 mm dia
100 mm dia
150 mm dia
Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts.
Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.
Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required.
Providing & fixing cast iron Air Release Valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement.
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : 2850 lpm at 88 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : Diesel Driven Pump. 2850 lpm at 88 m Head
Supplying, installation, testing and commissioning of electric driven pressurization pump suitable for automatic operation and consisting of following, complete in all respects, as required : Jockey Pump 180 lpm at 88 m Head
Electrical Pannel for Fire Pumps :Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurization pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Electrical Pannel for Fire Pumps :
Supplying and laying of aluminum conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-In-charge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 70 sq mm x 3-1/2core
Supply and fixing of brass nickel plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable size 70 sq mm x 3-1/2core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
size 35 sq mm
size 70 sq mm
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (All bends & tees shall be of factory built-in of same make as that of tray)
150 mm width X 50 mm depth X 1.6 mm thickness
Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm,coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board, cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified.
Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required.
Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade ) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing & fixing Flow Switch in following sizes M.S. pipe including connection etc as required.(150mm)
Providing, fixing, testing & commissioning of installation Control Valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :(100mm)
Providing & fixing cast iron Air Release Valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement.
Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :(Single headed Gunmetal)
Supplying and fixing single headed external Hydrant Valve with 1 No. 63 mm dia instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : (Single headed Gunmetal)
Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :(Gun Metal)
Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Providing & Fixing of 1.6 mm thick M.S / Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making Recessed type mansoary box (by civil contractor). 1200x900 mm (Indoor Cabinet) Only Frame
Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
UNDER GROUND SUMP (U.G.TANK)
Shade for pump room(considering the 1/3rd cost of construction for parking shade)
Supplying, installation, testing and commissioning of IP based CCTV sytem for bulking security comprising of PTZ/ fixed camera, cabling, recording, display system and hardware software support- for indoors only (rate applicable on total plinth area) (Note:- This area is including terrace for both CE1 & CE2 Buildings)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.49 MB
Lot_1.pdf
Tender Documents • 4.65 MB
BOQ_2081836.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid