Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.7 L+₹1.1 L (3.12%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹37.3 L+₹2.7 L (7.67%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.2 L+₹4.6 L (13.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹40.4 L+₹5.7 L (16.6%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
17 Apr 2024, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR
PROVN OF SOLAR WATER HEATERS FOR OTHER THAN MD ACCN ( BLDG NO P-12,13,14 ,15) AND AT OTHER LOCATIONS AND PROVN OF GEYSERS WITHIN AOOR OF AGE E/M AT AKHNOOR UNDER GE (SOUTH) AKHNOOR.
2024_MES_647285_1
GES/AKH-66/2023-24
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY a(ii)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹86,000
18 Jun 2024
20 Mar 2024
19 Apr 2024
20 Mar 2024
17 Apr 2024
4 Apr 2024
Amount
Supply, Installation, testing & commissioning Solar cum Electric water heaters of 1000 LPD capacity at 60 degree celcius , thermosyphon circulation suitable for bathing puprose consisting following components to be installed as per manufacuturer's instructions and disign (a) Flat plate collector - 10 Nos of approx (Each for 100 LPD) size 2.0M x 1.0M (b) Stainless steel tank SS-304 grade with puff insulation of thickness not less than 30 mm, (c) Collector Stand (d) Tank stand assembly (e) Hot water pipe from collector assembly to hot water tank and from hot water tank to bath room water point including laging to pipes an making connection for 15mm/20mm bore hot water pipe (Maximium 10RM) (f) Instrumentaion elements like one lamp gauge , strainer, water meter, heating elements and thermostat, flange, rubber gasket, nut, bolt washers, check valve at inlet & outlet etc as directed & Making Necessary electric and water connections (g) The arrangements formounting the colletor panels on the roofing sheeting system or on the ground including necessary PCC work as required (h) Hot water tank , seperate cold water tanks of capacity 1000 Ltrs, 5-layered , cold water pipe line. (j) 01 No MCB DP of caappcity 0-32 Amps with PVC gang box etc (k) Hot water pipe upto and incl 10RM shall deemed to be quoted in the quoted rate and beyond 10RM shall be paid seperately under respective items of BoQ. Notes:- (i) Any kind of addition/alteration, if required, to fit new panel in place of existing structure, the cost of the same is deemed to be included in the quoted rate and no extra payment will be made in this effect. (ii) The cost of MS structure/Steel stagging for Hot water tank will be paid separately. (iii) Testing of Solar water heating system shall be done in presence of manufacturer's rep to the entire satisfaction of GE and Engr-in-Charge and a testing report shall be signed by all concerned. Cost of this aspect shall deem to be included in the quoted rates. MAKE : TATA BP SOLAR or Equivalent makes in RACOLD/INTERSOLAR
Supply, Installation, testing & commissioning Solar cum Electric water heaters of 100 LPD capacity at 60 degree celcius , thermosyphon circulation suitable for bathing puprose consisting following components to be installed as per manufacuturer's instructions and disign (a) Flat plate collector - 01 Nos of approx (Each for 100 LPD) size 2.0M x 1.0M (b) Stainless steel tank SS-304 grade with puff insulation of thickness not less than 30 mm, (c) Collector Stand (d) Tank stand assembly (e) Hot water pipe from collector assembly to hot water tank and from hot water tank to bath room water point including laging to pipes an making connection for 15mm/20mm bore hot water pipe (Maximium 10RM) (f) Instrumentaion elements like one lamp gauge , strainer, water meter, heating elements and thermostat, flange, rubber gasket, nut, bolt washers, check valve at inlet & outlet etc as directed & Making Necessary electric and water connections (g) The arrangements formounting the colletor panels on the roofing sheeting system or on the ground including necessary PCC work as required (h) Hot water tank , seperate cold water tanks of capacity 100 Ltrs, 5-layered, cold water pipe line. (j) 01 No MCB DP of caappcity 0-32 Amps with PVC gang box etc (k) Hot water pipe upto and incl 10RM shall deemed to be quoted in the quoted rate and beyond 10RM shall be paid seperately under respective items of BoQ. Notes:- (i) Any kind of addition/alteration, if required, to fit new panel in place of existing structure, the cost of the same is deemed to be included in the quoted rate and no extra payment will be made in this effect. (ii) The cost of MS structure/Steel stagging for Hot water tank will be paid separately. (iii) Testing of Solar water heating system shall be done in presence of manufacturer's rep to the entire satisfaction of GE and Engr-in-Charge and a testing report shall be signed by all concerned. Cost of this aspect shall deem to be included in the quoted rates. MAKE : TATA BP SOLAR or Equivalent makes in RACOLD/INTERSOLAR
M&L and fabrication of steel staging using Angle iron and flat members of appropriate height in stand for mounting of 100 Ltrs or 1000 Ltrs (as applicable ) PVC water storage rank and making necessary arrangements for fixing of stand in of any surface by making holes having four holes for each leg and PCC/mortar work for grouting and making good disturbed surfaces and apply same finishes as exsiting including two coats of Synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed by Engineer-In-Charge. Note : 1. Payment of this item shall be done after assessing the actual requirement of structural steel member of appropriate size and after working out of feasiblity..... 2. Cost of arrangements of welding machine, filler and other T&P shall be included in the quoted unit rates of the item.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 25mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth and getting out, in any type of soil, for laying pipe line/Cable etc, complete all as specified and as directed by Engineer-In-Charge. Note :-The quoted rate shall be deemed to have included necessary "trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete complete including necessary all tools, tackles etc.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 20mm dia with iron wheel head, both ends screwed for iron pipe, complete all as specified and directed for following bore of pipes.
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 25mm dia with iron wheel head, both ends screwed for iron pipe, complete all as specified and directed for following bore of pipes.
Supply, installation and testing of vertical mounted electric water heater, storage type steel body with copper inner tank and heating element upto 2.0 KW capacity 25 litre, BEE 5 stars rated complete with all accessories such as safety valve, vaccum and pressure release valve and snap action thermostst , thermal cutout , non return devices, 240 volts with plug top, confirming to IS complete all as specificed and as directed
Supply, installation and testing of vertical mounted electric water heater, storage type steel body with copper inner tank and heating element upto 2.0 KW capacity 35 litre, BEE 5 stars rated complete with all accessories such as safety valve, vaccum and pressure release valve and snap action thermostst , thermal cutout , non return devices, 240 volts with plug top, confirming to IS complete all as specificed and as directed
Supply, installation and testing of vertical mounted electric water heater, storage type steel body with copper inner tank and heating element upto 2.0 KW capacity 50 litre, BEE 5 stars rated complete with all accessories such as safety valve, vaccum and pressure release valve and snap action thermostst , thermal cutout , non return devices, 240 volts with plug top, confirming to IS complete all as specificed and as directed
S & F PVC connecting pipe 45 cm long with two no.s brass check nuts and rubber washers suitable for 15 mm dia GI pipe for hot/cold water connection for geysers complete all as specificed and as directed
Supply and fixing Stop valves of size 15 mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Hot water pipe duly insulated with glass wool and aluminium cladding 25 mm bore, complete all as specified and directed.
Bib taps, long body, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Drilling, cutting and tapping GI water mains (in position) the existing pipe of 20MM diacfor branch connections including inserting tee of suitable sizes with all fittings complete all as specified and as directed by Engineer-In-Charge.
S&F Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 20-32 Amps, 240 Volts, complete all as specified and as directed.
S&F MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supply, install, testing and commissioning of Hi wall 2 Ton inverter type split air conditioner units indoor & outdoor with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality complete suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit and with copper condenser with minimum 5 star rating including suitable clamp set, fasterners for fixing of outdoor/indoor unit on wall, and making of holes for insertion of copper tubing, complete all as specified and as directed by Engr-in-charge.
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA with digital display complete all as specified and directed by Engineer-in-Charge. Make:- AE/ELECTRIC FIELD/ANDREW YULE/GODREJ.
Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
M/S A K ENGINEERS & CO.
SHSS ASSOCIATES
M/s Sekinder Paul Sharma
L-7 Primewave Communications
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .