Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.6 L+₹47,255 (1.88%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹25.9 L+₹79,210 (3.15%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹27.0 L+₹1.9 L (7.40%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹27.0 L+₹1.9 L (7.44%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
6 Oct 2022, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
PROVN OF MT SHED FOR VEH AND SPL REPAIR OF E/M SERVICES TO BLDG NO P-45 (ADM BLOCK) AT POONCH UNDER GE 881 EWS
2022_MES_550759_1
GE/PNH-47/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹63,000
Yes
17 Dec 2022
8 Sept 2022
13 Oct 2022
8 Sept 2022
6 Oct 2022
23 Sept 2022
Amount
B/R PORTION:- Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in any type of soil, complete all as specified and directed.
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in pole holes and stay assembly etc complete all as specified and directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified and directed.
M&L for hard core of broken stone/boulders of gauge exc 63mm but not exc 100 mm, deposited spreed and leveled in layers n exc 15cm thick watered and rammed to a true surface, complete all as specified and directed.
M&L for Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
M&L for 100 mm thick plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring, complete all as specified and directed.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for two coats of synthetic enamel painting on new steel surfaces over 10cms width or girth over a coat of red oxide primer etc complete all as specified and directed.
M&L for Forming 12mm thick expansion joint and filled with performed bituminous filler and top 30mm primed & sealed with sealing compound grade 'B' for 100 mm thick cement concrete slab complete all as specified and directed.
M&L for Forming construction joints 30 mm deep x 10 mm wide filled with sealing compound grade 'A' complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate), as in kerb or mud stops,rounded or chamfered angles and edges, complete all as specified and directed.
Excavation over area not exceeding 1.5m deep and and getting out in any type of soil, complete all as specified and directed.
M&L for Plain cement concrete 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
M&L for walling of random rubble stone/boulder masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed.
M&L for Raised pointing to random rubble masonary, or polygonal rubble, uncoarsed or brought upto courses in cement mortar 1:4, complete all as specified and directed.
M&L for cement concrete (1:2:4) using 20mm graded stone aggregate as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for providing precast cement concrete 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) as in bond stone, bed plate, strings coarse etc and set in CM (1:6), complete all as specified and directed.
M&L for Boulder filling dry hand packed tightly (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in Hard/dense soil complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified and directed.
M&L for reinforced concrete pipes 300 mm bore, class NP3, laid and jointed complete with collars complete all as specified and directed.
M&L for Concrete bed to drain pipes including packing under and haunching against the sides of pipes for RCC pipe after they are laid in PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs any type / capacity and making good disturbed surface to match with the existing surface, complete all as specified and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following:-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 31 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 5 pin, 6 Amp flush type universal), complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 6 & 16 Amp flush type universal, complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 6 Amp flush type, complete all as specified and directed.
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified and directed.
S&F in repair electric bell buzzer 230 volts AC supply complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
Supply and fixing in repair inverter LED batten of capacity 1x 20W, 220V, with square profile and polycarbonate channel, lithium ion battery with charging time 8 hrs to 10 hrs and back up time up to 4 hours and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make Havells cat part No. LHEXACP7FN1W020 or equivalent cat part as per make specified in PS
Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F sheet metal enclosure for DBs, TPN double door (IP43), 6 ways suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN, 40 to 63 amps, capacity 10 KA, 'C' series complete all as specified and directed.
S&F in repair MCB single pole 6 to 32 amps, capacity 10 KA, 'C' series complete all as specified and directed.
S&F in repair MCB isolators , 4 pole,415 volts, 80 amps, capacity 10 KA, 'C' series complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F in repair submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable, 1100 volts grade of size 2.5 Sqmm (nominal area) each and one single core 2.5 Sqmm cable as earth continuity conductor to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover complete all as specified and as directed. Note : Three runs of 2.5 Sqmm cable and one run of PVC conduit shall be measured as on unit
Supply and fix in repair LED emergency chargeable bulb having back up of capacity 9 watt, 6500K, output lumen 900, suitable for base B-22 complete all as specified and directed. Make Havells cat part No. LHLDEGEDML8O009 or equivalent cat part as per make specified in PS
S&F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V 20Amp complete all as specified and directed.
Taking down ceiling fan, and servicing of the same incl oiling, greasing, painting etc and including hanging of the same at existing position complete all as specified and directed.
M&L for rewinding of ceiling fan with the super quality copper wire of suitable gauge including testing complete all as specified and directed.
S&F in repair submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable, 1100 volts grade of size 4 Sqmm (nominal area) each and one single core 4 Sqmm cable as earth continuity conductor to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover complete all as specified and as directed. Note : Three runs of 4 Sqmm cable and one run of PVC conduit shall be measured as on unit
Modh Hafiz Khan
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
narayan construction
M/S BHATT TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .