| 1 | L1₹1.2 CrAccepted-AOC FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.2 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.2 Cr+₹2.7 L (2.20%)Rejected-Finance | ₹1.2 Cr+₹2.7 L (2.20%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹1.2 Cr+₹2.9 L (2.42%)Rejected-Finance B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | ₹1.2 Cr+₹2.9 L (2.42%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹1.2 Cr+₹3.7 L (3.09%)Rejected-Finance | ₹1.2 Cr+₹3.7 L (3.09%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹1.3 Cr+₹5.6 L (4.66%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹1.3 Cr+₹5.6 L (4.66%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
1 Feb 2023, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI RAO TULA RAM MARG DELHI CANTT 10
ADDN/ALTN TO OR MD ACCN BLDG NO. P-41 (16 QTRS) AMD P-42 ( 15 QTRS) AT ARMY HOSP (R AND R), DELHI CANTT-10
2022_MES_565330_1
CWE/ND-32/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
DELHI CANTT
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE E/M R AND R HOSPITAL
₹2.2 L
Yes
31 Mar 2023
25 Nov 2022
3 Feb 2023
25 Nov 2022
1 Feb 2023
18 Jan 2023
Amount
Taking down PVC chowkhats or frames not exceeding 1.5 sqm each (without taking off shutters from the frame) including making good disturbed surface in cement mortar 1:4 complete all as specified and directed.
Taking down chowkhats or frames exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frame) including making good disturbed surface in cement mortar 1:4 complete all as specified and directed.
Taking down chowkhats or frames not exceeding 1.5 sqm each (without taking off shutters from the frame) for steel windows only including making good disturbed surface in cement mortar 1:4 complete all as specified and directed.
S&F Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as directed.
S&F 30 mm thick Glass Fiber Reinforced Plastic (FRP) paneled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as directed.
S&F 125x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, and backside hollow filling of frame in PCC 1:3:6 Type C-1(using 20mm graded stone aggregate) including shop coat of priming etc,complete all as specified and directed.
S&F 105x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, and backside hollow filling of frame in PCC 1:3:6 Type C-1(using 20mm graded stone aggregate) including shop coat of priming etc. complete all as specified and directed.
S&F 35mm thick flush shutters, solid core construction, with black board core and plywood face panels, commercial type on both side complete all as specified and directed.
S&F factory made 35 mm thick II class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); complete all as specified and directed.
S&F powder coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots, hook and eye and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete all as specified and directed. NOTE : 1. Weight of aluminium section for window shutters will only be measured for payment purpose. 2. Cost of the hook and eye/hinges/pivots/epdm rubber/neoprene gasket, aluminium snap beading is included in this quoted rate for this item.
S&F Powder coated aluminium grill (minimum thickness of powder coating 50 micron) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved powder coated aluminium standard section around the opening, all as per requirement complete all as specified and directed.
S&F 250mm size alum alloy anodised sliding door bolt with hasp staple ( bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed.
S&F 125mm size aluminium handles, cast type anodised complete all as specified and directed.
M&L for cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) in lintels up to 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work, complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl. cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded or pointed in cement mortar complete all as specified and directed.
Demolition of reinforced cement concrete of any description and any position not otherwise specifically provided for and removing to a distance n.exc 500m etc., complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth of brick wall complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections complete all as specified and directed.
Supplying and laying of CPVC pipes 16 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Taking down G I tubing 20 mm bore and removal to contractor's store yard complete all as specified and directed..
Supplying and laying of CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Demolition of brick work stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
M&L for brick work with sub- class 'B' old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub- class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for 15 mm thick ready mix plaster on internal surfaces of concrete or brick walls complete all as specified and directed.
M&L for complete removal of old treatment on surfaces of walls through electrically operated grinder using sand paper for preparation of old decorated plastered surfaces of wall and applying two coats of distemper oil emulsion over & including a coat of wall care putty to achieve uniform, even & smooth surface including one coat of primer complete all as specified and as directed.
M&L for complete removal of old treatment on surfaces of ceiling through electrically operated grinder using sand paper for preparation of old decorated plastered surfaces of ceiling and applying two coats of distemper oil emulsion over & including one coat of primer complete all as specified and directed.
M&L for complete removal of Old decorated external surfaces of wall through electrically operated grinder using sand paper and applying wall care putty to achieve uniform, even and smooth surfaces and applying two coats of 100% anti fungal acrylic emulsion exterior grade weather proof over and including a coat of exterior primer complete all as specified and as directed.
M&L for removing vegetation/plants girth n. exc 15 cm on wall roof sunshade and junctions of over head tanks pipes etc. of the building up to G+3 filled the hole floor height up rooting to any depth and filling the hole by nominal mix concrete (1:2:4) type B0 with and including water proofing compound @3% by weight of cement and match the treated surface with proper safety arrangements to existing finished surfaces complete all as specified and directed.
Dismantling brick tiles or terracing tiles single layer on roofs complete all as specified and directed.
Demolition of Mud/ Mud phuska in roofs any thickness, including plastering and leeping if any and cleaning the roof surfaces with wire brushes and removal of Mud/ Mud phuska to a distance exceeding 250M and n, exc 500M complete all as specified and directed.
M&L cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregates) as in roof kerb, mud stops and padding complete all as specified and directed.
M&L for priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & directed:- (a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free of the moment till the primer is impregnated and the solvent oil in primer is evaporated (b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 85/25 confirming to IS-73 (Grade S-35). (c) Laying minimum 3mm thick APP polymeric water proofing membrane of weight not less than 3.0 kg/sqm, black finish reinforced with non woven polyester matt(not less than 150gm/Sqm), with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface. (d) Applying one coat of hot straight run bitumen grade 30/40 (Grade S-35) conforming to IS-73 @ 1.20 kg/Sqm. Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for cutting chase 20mm x 20 mm and termination of APP membrane . The membrane should be pressed into the chase and pointed immediately with a bitumen putty or similar approved bituminous sealant. The termination shall be done ideally minimum 200 mm above finished roof level complete all as specified and directed. Note:- Cost of APP membrane shall be measured & paid saperately under relevant item.
S&F pre- cast PCC tiles machine pressed of size 25cm x 25cm x 20mm thick over and including 20 mm thick screed bed in cement mortar 1:4, cement slurry @3 kg per sqm and joint, pointed grouted in cement mortar (1:2) using marble dust with admixture of pigment with and including WPC @ 200 ml per bag of cement complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and paving n. exc 15cm thickness ( below or above ground level) and removing to a distance n, exc 500m. complete all as specified and directed.
Cleaning of RCC surfaces to remove dust, loose particles, etc. with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges etc. complete all as specified and directed.
S&F 100mm stainless steel butt hinges and fixed complete all as specified and directed.
M&L for Water proofing sealing around perimeters & wall to floor junction with special tape made of thermoplastic elastomer reinforced with polyester woven fabric for waterproof sealing around perimeters and joints in wet tiled areas specially designed for wet room complete all as specified and directed.
M&L for sealing of pipe penetration of toilets core cutting & sunken slab treatment in comprising of following stages :- Supply and apply solvent free, moisture insensitive epoxy resin based patch repair putty Sikagrade - 694F (I) yield : 0.6 litre/kg, suitable for submerged condition having compressive strength of 40N/ mm² (1 day) according to IS 9162 - 1979 on pipe penetration surface. The putty shall be applied to a groove thickness of min 20 mm in pipe penetration joints to concrete. Preparation of surface of sunken portion and M & L for glass fiber reinforced acrylic modified cementitious coating system as Top coat : Sika Top Seal - 107 @ 1.5 Kg/ m² over reinforcement, Sika Fab - 1 over based coat : Sika Top Seal - 107 @ 1.5 KG per/m² etc all as specified and directed. System should have compressive strength : 20 N/ mm² , bond strength : 2.0N/mm² complete all as specified. Make : SIKA/ FOSROC/ STP with same nature of chemical treatment as prescribed above.
M&L for protection screed 1:2:4 in 50mm thickness laid on the horizontal surface admixed with integral waterproofing compound Plastocrete Plus of SIKA confirming to IS 2645 at the rate of 0.10 kg per bag of cement or conplast WL Xtra (FOSROC)/Shaliplast IW (STP) complete all as specified and directed.
M&L for protection plaster (12-15 mm thick) in cement mortar 1:3 on vertical surfaces admixed with appropriate integral waterproofing compound Admixture : Plastocrete Plus of SIKA @ 0.10 kg per bag of cement/ conplast WL xtra (FOSROC)/Shaliplast IW (STP) complete all as specified and directed.. Notes for srl item No. 42.00 to 45.00:- (i) Entire work shall be carried out through manufacturer or his authorised representative. (ii) The contractor shall furnish a 10 years guarantee for effectiveness of waterproofing treatment and the period shall be reckoned from the next day of actual date of completion of work. (iii) An amount of 2.5 % of total quoted amount against these items shall be retained, out of the final bill amount as security deposit, against guarantee of 10 years for water proofing effectiveness and the same shall be released only after the expiry of guarantee period. The contractor may also furnish fixed deposit receipt/ BGB in lieu of the security deposit to be retained as security.
S & F in repair 3-in-1 wall mixer with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs & wall flanges made of Cast copper alloy, chromium plated fancy type, complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) as in sub base concrete complete all as specified and directed.
S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
M&L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubbing down concrete surfaces with wire brushes cleaning with water allow to dry and applying a layer of Zink rich epoxy primer as in antirust on all exposed reinforcement followed by a layer of binding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited and applying two layers of guniting over & including steel welded mesh 2mm dia of wire and aperture 75mm total thickness of guniting not exc 40mm (avg thickness) in cement mortar 1:2 using OPC 53 Grade cement mixed with polycreate mixture @2% by weight of cement or as per manufacturers instructions and finally applying cement plaster over guniting surface of required thickness to give even uniform and smooth finishes confirming to proper geometrics in cement mortar 1:3 to match the existing surfaces as in sides soffits of the slabs chajja fins facia parapets lintels columns and beams etc complete including necessary scaffolding shuttering chasing to brick work or RCC members at any height up to 6 storied building including removal of all small trees/shrubs etc complete all as specified and directed.
S&F in repair 15mm bore cast copper alloy CP fancy type long body bib cock and fixing to GI pipe complete all as specified and directed.
S&F in repair fancy type chromium plated with cap 15 mm bore stop/angle valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair 15 mm wash basin mixer, with out pop up waste system, long body, made of cast copper alloy, chromium plated fancy type suitable for 15mm bore pipe complete all as specified and directed.
S&F in repair Chromium plated shower rose 125mm size with swivel joints any size including fixing with 15mm pipe including CP brass shower arm 200 mm long complete all as specified and directed.
S&F in repair Tubular towel rail, brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repair fancy type stainless steel soap dish fixed to plugs with chromium plated brass screws etc complete all as specified and directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe including 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed
M&L for rendering 15mm thick in cement mortar 1:4 on concrete surface or fair faces of brick walls , finished even and smooth using extra cement as in manholes complete all as specified and directed.
S&F 140 mm floor door stoppers of aluminium alloy body and tongue, anodised with hard drawn steel springs, fixed in doors complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks, triple layer, 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling of old water tank and connection. including necessary fittings (Tank nipple, sockets, union, nipple, etc ) as required complete all as specified and directed.
S&F in repairs PTMT ball valve high pressure with polyethylene float ball and fly nut complete screwed for iron pipe and fixed 20 mm bore, complete all as specified and directed.
S&F in repair 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed..
S&F PVC 110mm bore (SWR) bends, elbow provided with access door including taking down complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (single T) equal or unequal provided with access door including taking down complete all as specified and directed.
Dismantling cast iron work of any description and position complete all as specified and directed.
S&F Cast iron soil waste and vent pipe 100mm bore ( sand cast pipe) of in any length with or without ears, with cement joints fixed to walls complete all as specified and directed.
S&F Cast iron soil waste and vent pipe 75mm bore ( sand cast pipe) of in any length with or without ears, with cement joints fixed to walls complete all as specified and directed.
S&F cast iron bends spigot 100mm bore of pipe(any radius) diminishing, pieces or tapers( large bore measured) with oval access door complete all as specified and directed.
S&F cast iron bends, spigot 75mm bore of pipe(any radius) diminishing, pieces or tapers( large bore measured) with oval access door complete all as specified and directed.
S&F 100mm bore cast iron junction single, (single T) equal or unequal provided with access door including taking down complete all as specified and directed.
S&F for cast iron floor trap suitable of 75 mm dia outlet with grating including with jointing to waste pipe in run lead complete all as specified and directed.
M&L for stack clamps for 100mm bore of pipe made out of 50mm x 5mm thick flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends for stays to wall or roof complete all as specified and directed.
S&F 100mm cast iron of length up to 600mm branch pieces, Tee pieces, single (equal or unequal), ordinary or inverted ( spigot) or socket type) or with parallel branches complete all as specified and directed.
M&L for cast iron socket (double collar) 100 mm bore complete all as specified and directed.
S&F in repair CP grating square 125mm size of SS with or without hole for waste pipe fixed on traps complete all as specified and directed.
S&F in repair 20mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed..
S&F in 18mm thick WPC board having density more than 600Kg/Cum, one side prelaminated and other side balancing laminate colour to make wall mount kitchen cabinet shutter/drawer front shutters complete all as specified and directed.
S&F in continuous (Piano) hinges, mild steel, bright finish or electro galvanised of 30mm width of flaps (when open) complete all as specified and directed.
S&F 75 mm size stainless steel handle, fixed with nut screw and washer bright finished all as directed complete all as specified and directed.
S&F 100 mm long Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
M & L for vitrified tile 8-10 mm thick (Square/ rectangular) light shade area of each tile not exceeding 0.36 Sqm, in floor/skirting etc & jointed in neat cement slurry @ 3 Kg per sqm and pointed in coloured cement to match including screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L for non skid glazed ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floor/skirting etc & jointed in neat cement slurry @ 3 Kg per sqm and pointed in coloured cement to match including screed bed or bedding layer 15mm thick in cement mortar 1:6 complete all as specified and directed.
S&F non skid ceramic coloured tiles (400 X 400 mm) 7 to 8 mm thick (square/rectangular) in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match and laid over & including 15 mm thick screed bed or bedding layer of CM (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450 x 300 X 7mm thick set and jointed in neat cement slurry @ 3kg per sqm and pointed in white or coloured cement to match including 10 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing coat complete all as specified and directed .
M&L 18- 20 mm thick granite of jet black colour any type work (table rubbed and polished ) in steps with single piece, jambs, pillars, window cills, cooking platforms laid over & including cement screed bed or bedding layer 15mm thick in CM 1:6 for laying floor finishes including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for moulding or rounding cutting and smooth finishing on edges of Granite tiles etc complete all as specified and directed.
S&F in repair white colour, 1st quality vitreous china wash down water closet pan (Pedestal pattern) fancy type including PVC white seat cover, complete all as specified and directed.
S&F in repair PVC valve less, syphonic action type (10 Ltr) flushing cistern low level white with inlet ball valve, float and handle including bracket and 32mm PVC flush pipe including all joints and making good to the floor complete all as specified and directed.
Supply & Fix in repair 600mm long heavy duty for "Hot and Cold" PVC connection 15mm size with PTMT nuts complete all as specified and directed.
Supply & Fix in repair, 1st quality vitreous china wash basin, size 550 x 400 mm including brackets, 32mm bore CP coupling and PVC waste pipe complete all as specified and directed.
S&F in repair two way angle cock chromium plated cast copper alloy for fixing with flushing cistern/jet spray/health faucet etc for 15mm bore pipe complete all as specified and as directed.
S&F in repair sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washer and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915X460 mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair PVC waste pipe 32 mm dia complete all as specified and directed.
S&F in repair brass CP towel ring (min 150mm dia) complete all as specified and directed.
Dismantling boarding any description fixed in any position with rails complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry @ 3kg per sqm mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:6 size of Kota stone as decided complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25 mm thick in riser of steps with single piece, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry @3kg per sqm mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick rendering in CM 1:4 as a backing coat on walls for fixing of tiles size of Kota stone complete all as specified and directed.
M&L for Grinding and mirror polishing the existing kota stone flooring and wall complete including wax polishing complete all as specified and directed. Note : Standard size machine shall be used for grinding floor and hand grinding machine shall be used for vertical surfaces i.e. dado, skirting etc
S&F factory made precast heavy duty drain/ manhole covers including MS frame and including reinforcement as per IS 12592 : 2002 with specified thickness complete all as specified and director.
Demolition of cement concrete (Unreinforced) in ground floor and paving n. exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 75 mm thick cement concrete 1:4:8 type D2 ( 40mm graded stone aggregate) as in sub base concrete complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 ( Using 20mm graded stone aggregate ) as in flooring finished even and smooth surface complete all as specified and directed.
M&L for coloured chequered cement concrete ultra finished tiles 300x300x25mm size with epoxy coating ultra finished, over & including screed bed 20mm thick in cement mortar 1:4, set and jointed in neat cement slurry @ 3kg per sqm &, pointed with grey cement & pigment complete all as specified and directed.
M&L for RCC (Nominal Mix) 1:2:4 (20mm graded aggregate) as in slab, retaining walls, culvert etc. complete all as specified and directed.
S&F for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips Fe- 410-W (Gde E- 250). completed all as specified and directed
M&L for use & waste of formwork to soffits of suspended slabs for flat fair finished surfaces complete all as specified and directed.
M&L preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint completed all as specified and directed.
M&L applying one coat of synthetic enameled paint over 10 cm width or girth including preparation of old steel surfaces complete all as specified and directed.
M&L applying two coats of synthetic enameled paint over and including a coat of wooden primer on new wooden surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified and directed.
M&L for Excavation in trenches, n. exc 1.5m wide and n. exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, piers holes etc n.exc 10 sqm on plan and n. exc 1.5m in depth and getting out soft/ loose soil complete all as specified and directed.
M&L for Demolition and breaking up drain pipes ( salt glazed ware AC or reinforced concrete) of 150mm internal dia of pipe complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150 mm bore pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C2 ( using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes of 150mm bore after they are laid and tested; complete all as specified and directed.
M&L for 150mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm as in soft/ loose soil complete all as specified and directed.
Removing excavated/debris material exc 250 m but n. exc 500 m out side MoD premises, complete all as specified and directed.
S&F in repair 20-25 mm bore Harrison rails, stainless steel, with fixing brackets, stops, rollers, ends cap etc. complete all as specified and directed.
M&L for stack clamps for 75mm bore of pipe made out of 50mmx5mm thick flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends for stays to wall or roof complete all as specified and directed.
S&F 75mm Cast iron branch pieces, Tee, Single (equal or unequal), ordinary or inverted (spigot) or socket type) of length up to 600mm or with parallel branches complete all as specified and directed.
M&L for cast iron socket (double collar) 75 mm bore complete all as specified and directed.
M&L 2nd class hardwood plain fillets of sectional area exec 13 Sqcm but n exec 25 sqcm , rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed.
M&L two coats of oil emulsion distemper over and including a coat of primer and a coat of wall care putty to achieve uniform, even and smooth newly plastered surfaces of wall including preparation complete all as specified and directed.
M&L for applying wall care putty (exterior grade) to achieve uniform, even and smooth newly plastered surfaces of wall and then applying two coats of 100% anti-fungal acrylic emulsion exterior graded weather proof paint over & including a coat of exterior primer including preparation complete all as specified and directed.
S&F Sheet glass ordinary quality 4mm thick in Squares/ rectangular exc 0.5 Sqm in each pane complete all as specified & directed
S&F Sheet glass ordinary quality 4mm thick in Squares/ rectangular n.exc 0.5 Sqm in each pane complete all as specified & directed
S&F 100 mm size powder coated Aluminium, barrel tower bolts of extruded section complete all as specified & directed
S&F 100mm size powder coated aluminium handles, cast type complete all as specified and directed.
S&F in repair 15mm bore cast copper alloy CP fancy type short body bib cock and fixing to GI pipe complete all as specified and directed
M&L for 12 mm thick ready mix plaster on external surfaces of concrete or brick walls complete all as specified and directed.
Taking down old unserviceable point wiring with and including existing conduit type (light, fan, socket or power point) and any type switches, ceiling rose, pendent holder, regulator and socket and removing the material from site with chasing and cutting surface of wall/ ceiling etc complete all as specified and directed.
Taking down existing sub main wiring aluminium/copper 4/6/10 sqmm including existing conduit pipe complete all as specified and directed.
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper wire including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper wire connected to common earth and earth dolly and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, modular GI metal flush box suitable size for modular switches/sockets/fan regulators with suitable size of base plate & cover plate, etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :-
One light point controlled by one switch
One ceiling/exhaust fan point controlled by one switch
One socket outlet 5 Amps controlled by one switch on same board
One socket outlet 5 amps controlled by one switch on independent board
One bell point controlled by one bell push switch
One light point controlled by two Nos of two way switches
All as per srl item No. 134.00 here-in-before but with 2.5 Sqmm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp socket outlet on independent board
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper wire ISI marked, drawn into and including rigid PVC conduit of suitable size and including all PVC conduit accessories concealed in wall by cutting of chases in wall if required with and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire from main DB/Panel to sub DB complete all as directed. Note : The two run of 4 Sqmm wire, one run of 4 Sqmm wire for earth and PVC conduit pipe will be measured as one unit.
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper wire ISI marked, drawn into and including rigid PVC conduit of suitable size and including all PVC conduit accessories concealed in wall by cutting of chases in wall if required with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper wire ISI marked as earth wire from main DB/Panel to sub DB complete all as directed. Note : The two run of 6 Sqmm wire, one run of 6 Sqmm wire for earth and PVC conduit pipe will be measured as one unit.
Supply and fix modular Switch , single module ,single pole, one way, 5/6 Amps complete all as specified and directed.
S&F modular Switch , single module , 5/6 amps two way, SP, 230 volts AC complete all as specified and directed.
S&F modular Switch , single module , 15/16 amps one way, SP, 230 volts AC complete all as specified and directed.
S&F modular socket , two module ,5/6 amps 2 & 3 pin combined 230 volts AC complete all as specified and directed.
S&F modular socket , two module , 6/16 amps 2/3 pin combined, 230 volts AC complete all as specified and directed.
S&F modular Bell push switch, single module ,single pole, one way, 5/6 Amps complete all as specified and directed.
S&F modular electronic fan regulator, two module, step type, socket size and making all necessary connections complete all as specified and directed.
Supply and fix Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps with and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed.
Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc, complete all as specified and directed.
S&F in replacement LED tube light fitting 20 watt (CW) , 4 feet long in extruded aluminium batten with high efficient LEDs available in milky diffuser, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F in replacement tube light fitting 10 watt (CW), 2 feet long in extruded aluminium batten with high efficient LEDs available in clear & milky diffuser and, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
Supply and fix in replacement Building security light with high efficient high power LED street light 40 watt, PF>0.95 and Voltage rated 220V to 240V with lens and pressure die cast aluminium housing and enclosed with toughened glass IP-66 including service bracket 1.2 mtr long by using 32 mm bore GI pipe and fixing accessories ( Clips, Fasteners, Nut, Bolts etc) etc complete all as specified and directed.
Taking down carefully ceiling fan of any size, sealing cable end, dismantling blades & removing fan and blades to store complete all as specified and directed.
M&L for painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filter one coat after cleaning complete all as specified and directed.
Hanging only with fixing accessories ceiling fan and connecting with new 3 core flexible copper cable from ceiling rose to fan complete all as specified and directed.
Supply and fix in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections complete all as specified and directed. Note:- Labour for dismantling and extra cutting in walls if required for fixing of DB included in the quoted rates.
Supply and fix in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCBs and isolators etc and making all necessary connections complete all as specified and directed. Note:- Labour for dismantling and extra cutting in walls if required for fixing of DB included in the quoted rates.
M&L in replacement MCB 6 to 32 Amp, B Curve type, 10kA, single pole complete all as specified and directed.
Supply and fixing in replacement MCB, SPN type of 40 to 63 amps capacity, 240V, 10 KA with all connections complete all as specified and directed.
Taking down carefully exhaust fan any size, sealing cable and depositing to store complete all as specified and directed.
M&L for painting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filter one coat after cleaning complete all as specified and directed.
Fixing only exhaust fan and connecting up including provision of new cable from ceiling rose to fan & fixing arrangement complete all as specified and directed.
Supply and fix in replacement 9 W LED Bulb luminaire complete all as specified and directed.
Supply & Fix in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply & fix in replacement Bell Buzzer, Ding Dong single phase AC Supply 230 volts complete all as specified and directed.
Taking down carefully storage water heater of any capacity & refixing including all fixing arrangement & accessories complete all as specified and directed.
Shiv Shankar Nirman Co.
BEHAL TRADERS
R.K ENGINEERS & CONTRACTORS
imran construction company
M/s KUMAR BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .