Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | ₹14.5 L Quoted ₹15.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹17.0 LRejected-AOC | ₹17.0 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | ANNA RAJAN ENTERPRISES | VRK INFRASTRUCTURE |
|---|---|---|---|---|---|
| 1.00 | Testing of Conductivity in Raw Water, Strong Acid Cation, Strong Base Anion, Weak Base Anion, Mixed Bed and DM Water Storage Tank Samples at DM Plant-I and II. | 365 | Opn | 2,40,900 ₹2.8 L | 2,63,165 ₹3.1 L |
| 2.00 | Testing of pH in Anion and Mixed Bed Samples at DM Plant-I & II. | 365 | Opn | 2,40,900 ₹2.8 L | 2,63,165 ₹3.1 L |
| 3.00 | Testing of Silica in Anion and Mixed Bed samples at DM Plant-I & II | 365 | Opn | 2,40,900 ₹2.8 L | 2,63,165 ₹3.1 L |
| 4.00 | Pressure gauge and Flow meter reading taken in Contact Tank, Sand Filter, Activated Carbon Filter, Filter water and DM Water and recorded in Treatment ragister at DM Plant-I & II | 365 | Opn | 1,75,200 ₹2.1 L | 1,90,895 ₹2.3 L |
| 5.00 | Testing of Hardness, FMA in Strong Acid Cation samples, P-Value in Anion samples at DM Plant-I and DM Plant-II | 365 | Opn | 1,97,100 ₹2.3 L | 2,15,350 ₹2.5 L |
| 6.00 | Recirculation of Neutralizing pit and testing of pH at DM Plant-I and DM Plant-II | 365 | Opn | 1,75,200 ₹2.1 L | 1,90,895 ₹2.3 L |
| 7.00 | Testing Conductivity ,Total Hardness, Alkalinity, Silica etc in Raw Water Samples, Collected from DM Plant I & II, Auxiliary Cooling water of Units I, II and III daily. Reagent preparation for various testes and testing of various parameters of Sea Water weekly. | 365 | Opn | 2,84,700 ₹3.4 L | 3,10,615 ₹3.7 L |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
25 Dec 2025, 2:00 pmClosed
CE/TTPS
O/o CE/TTPS
TTPS Operation Circle Chemical Division Testing and analysis works of DM Plant I and II on round the clock basis for the period from 01.04.2026 to 31.03.2027
2025_EB_630914_1
CE/SE/O/TTPS/Spec.No.31/26-27
Open Tender
Miscellaneous Works
365 days
TTPS
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹12,000
Yes
23 Mar 2026
11 Dec 2025
26 Dec 2025
11 Dec 2025
25 Dec 2025
11 Dec 2025
Testing of Conductivity in Raw Water, Strong Acid Cation, Strong Base Anion, Weak Base Anion, Mixed Bed and DM Water Storage Tank Samples at DM Plant-I and II.
Testing of pH in Anion and Mixed Bed Samples at DM Plant-I & II.
Testing of Silica in Anion and Mixed Bed samples at DM Plant-I & II
Pressure gauge and Flow meter reading taken in Contact Tank, Sand Filter, Activated Carbon Filter, Filter water and DM Water and recorded in Treatment ragister at DM Plant-I & II
Testing of Hardness, FMA in Strong Acid Cation samples, P-Value in Anion samples at DM Plant-I and DM Plant-II
Recirculation of Neutralizing pit and testing of pH at DM Plant-I and DM Plant-II
Testing Conductivity ,Total Hardness, Alkalinity, Silica etc in Raw Water Samples, Collected from DM Plant I & II, Auxiliary Cooling water of Units I, II and III daily. Reagent preparation for various testes and testing of various parameters of Sea Water weekly.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
BOQ_754481.xls
BOQ • 0.28 MB