Chief Engineer,RRCAT.
office of CE,CSD building, RRCAT.
Balance work of Extension of Users building in Technical area of RRCAT,Indore
2022_RRCAT_716946_1
RRCAT/CSD/3069/W-4168
Open Tender
Civil Works
Works
240 days
RRCAT
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.7 L
28 Nov 2022
11 Oct 2022
11 Nov 2022
11 Oct 2022
7 Nov 2022
11 Oct 2022
Amount
Extra over item no.1 for each additional depth of 1.5m or part thereof.
Earthwork excavation in foundations in soft rock by mechanical means (hydraulic Excavator)/manual means upto a depth not exceeding 1.5m including shoring and dewatering, if necessary and disposing of surplus excavated materials within a distance of 50 metre.
Extra over item no.3 for each additional depth of 1.5m or part thereof.
Excavation in foundations in hard rock by mechanical means (hydraulic Excavator)/manual means by Blasting upto a depth not exceeding 1.5m including dewatering, if necessary and stacking or disposing within a distance of 50 metre .
Earthwork excavation over areas in all soils except soft and hard rock by mechanical means (hydraulic Excavator)/manual means and disposing off & levelling the soil within a distance of 50 metre.
Demolishing plain cement concrete works by chiselling at all levels including scaffolding, disposal of materials within 50 metres lead etc. complete.
Demolishing Reinforced cement concrete works by chiselling at all levels including scaffolding, cutting of reinforcement bars by gas cutting, straightening & stacking of steel bars and disposal of unserviceable materials within 50 metres lead etc. complete.
Dismantling the existing structural steel work at all levels in M.S. channels, plates, angles, flats, R.S. joists, bolts etc. including scaffolding, cutting of structural steel members by gas cutting, removing the nuts, bolts etc. complete and shifting the dismantled material by mechanical transport to departmental stores.
Demolishing brick work in cement mortar at all levels including scaffolding, stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead etc. complete.
Taking out DOORS, WINDOWS AND CLEARSTORY WINDOWS, shutters (steel or wood) including stacking within 50 metres lead etc. complete and as per drawings, specifications & as directed by the Engineer-in-charge.
Of area 3 m² & below
Of area beyond 3 m²
Lead charges, by mechanical transport to anywhere in RRCAT CAMPUS, including loading, unloading, stacking/levelling etc. complete.
For soil
for debris up to 3.0 km
Cement concrete 1:3:6 using graded stone aggregate 40 mm max. size including consolidating, finishing, curing etc. complete excluding formwork as per specifications.
Construction of Granular sub base by providing coarse graded material as per specified grading, spreading in uniform layers on the prepared surface, mixing at optimum moisture content and compacting with vibratory roller/mechanical earth rammer to achieve the desired density complete.
For grading - I material (with 75mm and down size aggregates)
For grading - II material (with 53mm and down size aggregates)
REINFORCED CEMENT CONRETE of M-25 grade using graded stone aggregate of 20mm max. size including machine mixing, weigh batching mechanical vibration, consolidation, finishing, curing and cost of labour, machinery, and materials etc. complete specifications but excluding shuttering, formwork and steel reinforcement.
In foundations, footings, plinth beams, base of columns, flooring.
In columns, mullions, pillars, posts, struts
In beams, slabs, lintels, Staircase, bed blocks, chajjas, canopies, shelves, walls and window cills.
In facia, fins
Providing, centering and shuttering using timber planks/steel plates including strutting and propping etc. upto first floor (not exceeding 4 mtr. height) and removal of the same for in situ reinforced concrete and in plain concrete work
Foundations, footings, base of columns plinth beams, flooring, machine foundations, bed blocks, window cills, copings and mass concrete
Columns, pillars, posts, struts, mullions etc.
Sides and soffits of beams, beam haunchings lintels, cantilever, girders, bressumers, soffits of suspended floors, roofs, balconies, chajjas etc.
Facias, drop walls, pardis, vertical and horizontal fins individually or forming box louvers and bands, staircase etc.
Providing and fixing reinforcement for reinforced cement concrete using TMT bars of SAIL / RINL/TATA make at all levels including supplying, cutting, bending, fixing, tying in position with 1.6mm dia soft drawn annealed binding wire etc. complete including cost of binding wire.
Note: 1.The steel reinforcement bars shall be brought by the contractor at terms & conditions specified.TMT bars manufactured in the brand name of SAIL/RINL/TATA shall only be permitted subject to furnishing of challans, valid test report issued by the manufacturer, pertaining to elongation,yield strength,Bend rebend test etc.
Note : 2. Random testing of sample collected at site shall be arranged by the contractor at their own cost.One sample comprisin of three specimens shall be collected for every 25MT of bars brought at site .The representive of department shall associate with the engineer of contractore at each satge right from sampling of testing .All charges ,transport taxes etc shall be borne by the contractor.
Note : 3. the contractor shall be solely respossible all the time for watch & ward of bars/binding wires etc at their own cost.
Note : 4. 1.60mm dia . Soft drawn annealed BINDING WIRE required for the work will have to be procured by the contractore at their own cost and will not be measured for payment .
Note : 5. Other condtion as stipulated in general condition, special conditions, additional conditions and specification shall also be applicable and no claim whatsoever on account of enforcing these provisions shall be entertained .
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using ISMBs, Joists, channels, angles, flats, Tees etc. at all levels including welding, painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
Providing, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using Structural steel M.S. plain & chequered plates at all levels including welding, painting with a primary coat of approved steel primer and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. (The welding weights shall not be measured for payments but cost of same shall be included in the rate.)
1. Structural steel conforming to IS: 2062
2. The contractor shall supply copy of Documentary evidence of purchase of steel, test certificates from these firms and also testing from third party, if required to be arranged at no extra cost.
3. Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rate.
4. All holes will be made by drilling only. Gas cutting of holes will not be permitted.
5. Electrodes manufactured by M/s. Advani Oerlikon, ESAB India, Oxygen and D&H SECHERON only shall be used.
Brick work in cement mortar 1:6 using table moulded chimney bricks having a compressive strength not less than 40kg/cm² in foundation, plinth upto FFL and compound wall pillars including curing, raking out joints above ground level, simultaneous pointing below G.L. etc. complete as per specifications,
Brick work in cement mortar 1:6 using table moulded chimney bricks having a compressive strength not less than 40kg/cm² in superstructure at all levels including double scaffolding, raking out joints, curing etc. complete as per specifications,
Cement concrete flooring 50 mm thick consisting of 38 mm thick cement concrete 1:1½:3 with 10mm size aggregate as under layer, and 12mm thick wearing surface with METALLIC FLOOR HARDNER cement being mixed with metallic floor hardener of approved quality and make in proportion of 4:1 (4 cement : 1 Metallic floor hardener) by weight and cement hardener compound mixed with 6mm down graded stone aggregate in the ratio of 1:2 by volume including, ramming, finishing, to required levels or slope, providing, dividing strips, curing etc. complete generally as recommended by the manufactures etc. complete.
With aluminum dividing strips of size 25mm x 3mm
Cement plaster 20mm thick in skirting and risers to steps with cement mortar 1:3 finished with a coat of neat cement including rounding of junctions with floor where necessary curing etc. complete.
Kota stone Treads and Risers using machine cut double machine polished kotah stone slabs laid over 20 mm thick mortar bedding, close jointed and pointed with matching cement slurry finished to levels, slope or plumb as required and cured etc. complete.
For Treads, 25 to 30mm thick approx. over lime mortar 1:2 bedding, with all exposed edges machine cut and surfaces hand polished after laying.
Kota stone flooring/skirting, using 25mm to 30mm thick hand cut single machine polished kotah stone slabs laid over 20 mm thick mortar, close jointed and pointed with matching cement slurry finished to levels, slope or plumb as required and cured etc. complete.
In flooring with lime mortar 1:2 bedding and with machine polishing after laying.
In skirting with 20 to 25mm thick stone slabs over cement mortar 1:3 backing, with exposed edge machine cut and surfaces hand polished after laying.
Providing and fixing in position anodized (min of grade AC10) / powder coated (min 50 microns) aluminum three track sliding windows, ventilators with mosquito net etc., using aluminum alloys extruded section as per approved make confirming to IS: 733 and IS: 1285. The outer frame shall be of extruded aluminum verticle and horizontal rectangular sections of minimum size 92.00 x 36.00 x 0.90 mm thick, Bottom track sections of minimum size 92.00 x 31.00 x 1.50 mm thick, top & side members 92.00 x 31.00 x 1.50 mm thick and aluminum sections for frame of window sliding panels for top, bottom, verticle & interlocking members of minimum size 40.00 x 18.00 x 1.55 mm thick, including providing and fixing concealed type heavy duty (metal - body, hook & bracket) locking arrangement of approved shade and make, heavy duty roller (smoother carbon steel bearing type), PVC liner, aluminum angle cleats, S.S bearings, C.P. brass screws / stainless steel screws, mastic filling, nuts, washers, Rawl plugs, aluminum packing strips used for anchoring system as per the requirements, transportation, cost of all labours, scaffolding if necessary, machinery, tests, chipping of walls, beams, columns, rectification of plaster, painting if required etc. and as directed by EIC. Including scaffolding if necessary, chipping of walls, beams, columns, rectification of plaster, painting if required.
Including providing and fixing float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm) in two panels of window with edges champhered (wherever required) with PVC/Neoprene Gasket Lining etc. complete and mosquito net jali in one panel of window as directed by EIC.
With anodized aluminum section (min of grade AC10) of approved shade
Providing and fixing in position anodized (min of grade AC10) / powder coated (min 50 microns) aluminum doors with extruded and integrated aluminum sections as per approved make confirming to IS: 733 and IS: 1285 aluminum beading, PVC lining, CP brass / stainless steel screws, mastic filling, nuts, washers etc. complete including scaffolding if necessary, chipping of walls, beams, columns, rectification of plaster, painting if required. Vertical and middle horizontal section of door shall be min 80 mm x 44 mm and of thickness minimum 2 mm. Top and bottom horizontal section of door shall be min 120 mm x 44 mm and of thickness minimum 2 mm Snap beading shall be minimum 0.41 mm thick. Cleat angles shall be minimum 25 x 25 mm and thickness 2 mm.
Including providing and fixing in position 5mm thick glass or opaque using 12mm thick laminated particle board.
Specifications of glass:- clear sheet glass/float glass of approved make and of 5mm thickness fixed to aluminum partitions with edges champhered (wherever required) with PVC/Neoprene Gasket Lining etc. complete.
Specifications of laminated board:- 12 mm thick both side laminated particle board of approved exterior grade - 1, Type II confirming to IS 12823 bonded with Phenol Formaldehyde Resin (Novapan/ECO board or any other approved equivalent) in doors using necessary approved standard aluminum beadings including wastages, if any, fixing to existing framework with C.P. brass / stainless steel screws as required and other incidental charges etc. complete.
Anodized aluminum (min of grade AC-10) doors, fully glazed with 5 mm thick glass or opaque using 12mm thick laminated particle board and the vertical members are internally braced with 12mm dia MS long bolt, SS handle on both sides as approved, floor spring/door closer of Godrej make, concealed tower bolts, locking arrangements using SS aldrop 16mm dia and 300mm long etc complete.
Providing and fixing in position Aluminum partitions, doors, windows, ventilators, louvers, fixed glazing, sliding windows, north light glazing, aluminum rough ground etc. with extruded and anodized (10 microns) to natural aluminum colour, aluminum sections, anodized aluminum beadings, anodised aluminum sheets manufactured to relevant IS codes and using minimum 2mm thick (or as specified) heavy sections INDAL/JINDAL/MAN or approved equivalent make including cost of pivots, approved door and window handles, EPDM gasket, PVC/Neoprene Gasket lining, stainless steel screws, mastic filling, weather strips, tower bolts, nuts, washers etc. as required complete as per drawing, specifications and as directed by Engineer-in-Charge.
Providing & laying in position 28 guage stainless steel mosquito proof jalli with aluminium frame work including fixing to the existing frame work, cost of all materials, washers, nuts, screws, tools & tackles etc. complete as per specifications and as directed by Engineer-in-Charge. Note : Aluminium sections will be measured and paid for separately under relevant item.
Providing, fabricating, supplying and erecting factory made single/double leaf metal flush door insulated with polyurethane foam (density of PUF shall be 40kg/m³) of “Sen harvic/ABAQS/STAR METAL” make consisting of 1.5 mm galvanised pressed steel frame of size 105mm x 57mm with suitable stiffeners and 1mm prime quality galvanised pressed steel shutter, 35mm thick shutter with necessary stiffeners for hardware, with applying a coat of two pack epoxy primer and two coats of polyurethane paint above etc. complete including providing & fixing vision panel using 4mm plain glass, aluminum/CPMS fittings, fixtures heavy duty Stainless steel hinges, Godrej make door closure and locking arrangements with screw and check for correctness of recesses and stiffening plates for all fittings & fixtures including the cost of grouting the hollow portion of door frame with cement concrete 1:2:4 etc. complete. Note: Fittings & fixtures shall be as indicated in tender drawing.
Providing and fixing in position Gear Type operated by mechanically winding handle, steel rolling shutters as per IS-6248 of approved make, made from M.S. laths (80mmx1.20mm) size including all necessary fixtures, fittings, 1.20mm thick top hood, brackets, guide channels, ceiling strips, locking arrangements, shutter suspension shaft with 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and , ceiling strips, locking arrangements, and painting with two coats of synthetic enamel paint over a coat of approved steel primer including fixing the guides in masonry/concrete etc. with necessary coach screws/anchor fasteners, nuts, bolts, etc. complete.
Cement plastering at all levels for internal walls ceilings with cement mortar 1:4 over brick walls or concrete surfaces, including hacking of concrete surfaces, double scaffolding, curing etc. complete.
12 mm thick
20 mm thick
Sand faced plaster 20mm thick in 2 coats over exterior masonry and concrete surfaces at all heights with base coat in cement mortar 1:4, 12mm thick and finishing coat in cement mortar 1:3, 8mm thick final rendering, double scaffolding wherever necessary, hacking of concrete surfaces, curing etc. complete and addition of waterproofing compound @ 2% of weight of cement for the base coat etc. complete.
Cement plastering to external surfaces of walls at all heights, 20mm thick, with cement mortar 1:4 over brick walls or concrete surfaces, including finishing smooth hacking the concrete surfaces, double scaffolding wherever necessary, curing etc. complete.
Waterproof cement plaster in cement mortar 1:3, with waterproofing compound @ 2% by weight of cement including double scaffolding, curing, hacking of concrete surfaces etc. complete.
12mm thick
20mm thick
Providing and fixing in position 24 G G.I. Chicken wire mesh of size 15mm x 15 mm fixed at the junction of beam and wall, junction of column and wall including cutting to required size, tying the mesh to bars/nuts which are properly welded to the metallic inserts or tying with 16 G annealed binding wire, removing all undulations, tight fixing and including cost of all materials and labours etc. complete.
Providing cement based waterproofing treatment to New Terraces, chajjas cleaning the concrete surfaces, giving injections to top slab as required with cement and approved waterproofing compound solution to fill up all inherent holes, voids honey-combs etc. in the concrete slab, setting brick bat coba in waterproof mortar 1:3 with necessary gradient for easy flow of water and continue the treatment along the inner faces of parapet or other adjoining wall up to a height of 300mm in the shape of vatas, with waterproof plaster 1:3 finished smooth with trovel in geru with false markings of 300mm squares including the cost of providing & fixing the chicken wire mesh before finishing the surface etc. complete. (The treatment shall be tested by ponding water for a period of 10 days).
1. If due to location of rain water pipes the thickness of treatment exceeds 110mm, for easy flow of water, provision is to be made of extra brick relevant item in this chapter.
2. The waterproofing treatment is to be GUARANTEED for bone dry condition for a period of 10 years.
3. An amount @ 10% of the value of the item shall be withheld by the department for a period of 10 years from the date of completion.
4.The measurement for payment shall be the entire area of terrace/chajja covered by the treatment measured between brick/concrete parapets without plaster and the area of vatas calculated by taking the length of vatas and the height above the finished level of the terrace/chajja.
Terraces - average thickness 110mm with cement geru finish
Painting plastered surfaces with two/three coats of Acrylic emulsion paint of approved shade and make over one coat of approved cement primer including preparing the surfaces, filling with full wall putty, scaffolding and cleaning etc. complete
Two finishing coats over a coat of primer
Painting New exterior walls with two coats of Waterproof cement paint of approved shade including preparing the surfaces, filling with putty wherever required, scaffolding and cleaning etc. complete.
Using SNOWCRYL XT/ APEX ULTIMA
Providing pre-construction anti-termite treatment (with chloropyrifos 1% concentration) generally as per IS 6313 (Part-II)-1981 guaranteed for ten years complete. The treatment shall comprise of following stages :-
a). Treatment around foundation, footing & columns :- Soil poisoning from the depth of 500mm below ground level around RCC/Brick foundations, columns, plinth beams, walls, etc. with chloropyrifos (1% concentration) @ 7.50 litres per sq.m. of vertical surface including rodding the earth at 150mm centre to centre close to the column/ beams/walls surfaces, spraying the chemicals so as to soak the soil right to the bottom complete including tamping back the soil into place after this operation.
b). Treatment around internal/external walls or plinth beams :- Soil poisoning from the ground level upto the level of filled up earth surface around junction of internal/external wall and floor with chloropyrifos (1% concentration) @ 7.50 litres/m². of vertical surface so as to establish continuity of the vertical chemical barrier on inner wall surfaces from ground level including making a small channel of size 30mm x 30mm, rodding the channel at 150mm centre to centre to pour the chemical, spraying the chemicals so as to soak the soil right to the bottom complete including tamping back the soil into place after this operation.
c). Treatment of soil below sub grade of floor :- Soil poisoning of the top surface of the filled earth within plinth wall with chloropyrifos @ 5.00 litres/m². of the surface including making hole 50 to 75 mm deep at 150mm centre to centre both ways.
d). Treatment of soil along external perimeter of building :- Soil poisoning along external perimeter of the building including making holes with iron rods, 300mm deep @ 150mm intervals filling these holes with chloropyrifos @ 7.50 litres/m². of the perimeter walls. In the event of filling being more than 300mm, the external perimeter treatment shall extend to the full depth of filling upto the ground level so as to ensure continuity of the chemical barrier.
Note: The amount @ 10% of security deposit deducted from the item shall be withheld by the department for a period of 10 years from the date of completion (as per service guarantee).
Providing, laying or fixing approved quality PVC RAIN WATER PIPES & FITTINGS of make Supreme/Astral Pipes/Finolex pipes conforming to IS : 13592, with necessary clamps or concealed in walls including jointing with approved solvent ,clamping, and scafolding etc. complete. as per specification and direction by Engineer In charge.
110mm dia PVC pipes
Providing and fixing laminated closed cell Polyethylene foam joint filler 20mm thick (CAPCELL-HD-100 or other approved equivalent make) for expansion joint or other places including cutting, positioning, supporting, scaffolding and filling with approved sealing compound etc., complete.
Providing and fixing in position EXPANSION JOINT COVERING USING 1mm thick G.I. sheet bent to proper shape and profile and secured in position with necessary screws, plugs etc. complete.
Providing & fixing in position 50mm thick heavy density THERMOCOLE (density not less than 18kg/m³) in ceilings for under deck insulation at all heights, tying thermocole to ceiling with 10 G G.I. wire including cutting to required size, sticking with bitumen & sealing the joints with approved bitumastic compound etc. complete including cost of all materials and labours involved for complete work etc. as per specification.
Providing & fixing in true horizontal level M/F suspended false ceiling (FR-120 min) system manufactured by M/s Saint-Gobain Gyproc India using Gypsteel Ultra perimeter channels (27mm web and 20 & 30mm flange) fixed to wall with rawl plug and screws, at 610mm centres along the perimeter of ceiling, intermediate channels(45mm web and 15mm each flange) from the soffit at 900mm centre with ceiling angle (25x10mm,0.55mm thick) fixed to soffit @ 1220mm c/c with GI cleat and steel expansion fasteners to form a grid of 900mm x 1220mm. Ceiling section (51.5mm web and 26mm each flange)fixed to intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457.5mm centres. Single layers of 15mm tapered edge Gyproc Fireline fixed to ceiling section with screws at 230mm centres,
Square and tapered edges of the boards to be jointed and finished flush look including filling and finishing with jointing compound, paper fiber tape and two coats of drywall top coat etc. complete.
False ceiling/masking suspended by anchor rods fixed with anchor fasteners and 15mm tapered edge Single layers Gyproc Fireline board panel on one side.
Providing & fixing best quality Laboratory Sinks of size mentioned below, comprising of :
a. Best quality white glazed vitreous chinaware sinks of size mentioned below of approved nake with integral overflow weir at end, supported on a pair of white enamel painted C.I. brackets, conforming to IS : 771 part - 2.
b. One number suitable C.P. brass waste heavy quality with rubber plug and C.P. chain. Including C.P. brass union.
c. One number suitable C.P. brass heavy quality bottle trap with extension piece and wall flange etc. complete of dripless of approved equivalent.
Vitreous china Laboratory Sink of size 600mm X 450mm x 200mm
Providing and fixing heavy quality C.P. brass screw down 15mm n.b. SWAN NECK TAP of Jaguar(FLR-5347N)/Plumber (AZT-1102) or approved make confirming to IS:8931 on G.I. pipe line
Providing, laying, jointing, fixing, testing and painting as per colour code of BARC heavy quality (Class C) M.S. Galvanised pipes as per IS:1239 of Prakash Surya or Jindal make including fittings like elbows, collars, tees, unions, couplings, reducers, enlargers, bends and all other fittings required for the completion except screwed flanges conforming to IS:1239 and also as per the code of practice of water supply in buildings of IS: 2065 including laying under the floor, chasing in walls, roof slabs and making good the same to the orifinal conditions, testing the pipes & fittings for 10kg/sqcm pressure for a minimum period of two hours duration with clean & potable water, including cutting to waste of pipes, threading, cost of all jointing materials like hemp yarn, white or red lead, painting with two coats of anti-corrosive bitumastic paint for under portion & oil paint for exposed portion over a coat of primer, clamps, wooden gutties, screws, cement, sand etc. complete
Providing and fixing in position heavy pattern screw down gun metal GATE VALVEs of Sant/Leader make conforming to IS:778 with hand wheels at top including testing for 10 kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc. as per specifications and as directed by Engineer-in-charge.
Providing and fixing C.I. Floor trap of self cleansing design with 75mm outlet having a minimum water seal of 50mm with stainless steel grating on top including necessary 1:2:4 cement concrete for embedding the trap etc. confirming to IS:3989 and as per specifications all complete.
Providing, laying or fixing in position under floors or against walls centrifugally cast (spun) Iron or sand cast Iron socket and spigot soil, waste, ventilation pipes and fittings including cost of all fittings like bends, offsets, tees, tapers, collars, connectors, plugs, shoes etc. conforming to IS: 3989 and IS: 1729 respectively, including cost of jointing with tarred spun (jute) yarn and molten pig lead, caulking the joints, including testing, painting with two coats of approved paint over a coat of primer etc. complete as per drawing, specifications and as directed by Engineer-in-charge.
75mm n.b. pipes (with 0.90 kg of lead per joint)
Providing and fixing wrinkle free sun control polyester film (Garware etc.) to the glasses of windows/ aluminum wall spans in approved reflective shades including cleaning of windows/glasses properly, cutting of film properly, fixing of approved of approved adhesive on window glasses & polyester film and fixing of film including all labours, materials, adhesive and any other material required for fixing the polyester film to the glasses etc. complete.
Non Slippery Ceramic tile flooring/dado using 6mm thick matt finished ceramic tiles of sizes as mentioned below, 1st quality (SPARTEK/ NITCO/BELL/KAJARIA/ EURO/SOMANI) over 20mm thick cement mortar 1:3 bedding, close jointed and pointed with matching cement slurry using white cement pigment mixed with, finished to levels slope or plumb as required including 20mm thick cement mortar 1:3 bedding, making good the surface before bedding, cutting of tiles, curing, acid washing etc. complete.
For flooring using tiles of size 300x300mm, 450x450mm
For Dado/Skirting using tiles of size 300x450mm
Providing and fixing Welded wire mesh (25 x 25 x 3mm) of best quality and approved make to existing frame, including cutting, making holes, etc. fixed in proper line and level etc. complete.
Supplying, lowering, laying, RCC spun pipes (Class NP2) of IS : 458 with necessary collars, laid to correct grade and levels at all depths including cutting to length, jointing with hemp yarn and C.M. 1:1, caulking the joints and finishing, curing, testing etc. complete.
Labour charges only for fabricating structural steel work including plates at all levels including transporting to site of work from Deptt. Stores, cutting to required size, fabricating including welding as required, erecting in position cost of electrodes, gas, necessary scaffolding, painting with a coat of approved steel primer etc. complete.
Providing and fixing in position clear sheet glass/float glass of approved make and of following thickness fixed to aluminum windows, doors, partitions, ventilators etc. with edges champhered (wherever required) with PVC/Neoprene Gasket Lining etc. complete. Note: Only the clear opening of Glass shall be measured for payment. Aluminum snap beading shall be measured and paid under relevant item.
With float glass panes of 4.0 mm thickness (weight not less than 10.00 kg/sqm)
B.K. ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .