SUPPLY DELHI CANTT 10
SUPPLY DELHI CANTT 10
REPAIR MAINTENANCE WORK OF SWIMMING POOLS UNDER GE U WATER SUPPLY DELHI CANTT 10
2024_MES_647637_1
GE/WS/IFA-167/Token-76 OF 2023-24
Open Tender
Civil Works
Item Rate
330 days
SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
SUPPLY DELHI CANTT 10
₹60,000
Yes
3 Sept 2024
22 Mar 2024
15 Apr 2024
22 Mar 2024
12 Apr 2024
5 Apr 2024
Amount
Cleaning of TOI Swimming Pool of size 25 m x 13.5 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.
Cleaning of NOM Swimming Pool of size 25 m x 13.5 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.
Cleaning of RRRC Swimming Pool of size 25 m x 13.5 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.
Cleaning of DID Swimming Pool of size 50 m x 21 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.
Cleaning of Harbux Stadium Swimming Pool of size 50 m x 21 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.
Cleaning of Harbux Stadium Deep Diving Pool of size 16 m x 16 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.
Cleaning of Harbux Stadium Baby Pool of size 6 m x 4 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.
(Note for item Ser No 1 to 7 : Quoted rates shall be included for providing manpower and cleaning material,safety gears and ladders etc required at site for filling up the swimming pools with water.)
Cleaning of TOI Swimming Pool of size 25 m x 13.5 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.
Cleaning of NOM Swimming Pool of size 25 m x 13.5 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.
Cleaning of RRRC Swimming Pool of size 25 m x 13.5 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.
Cleaning of DID Swimming Pool of size 50 m x 21 after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.
Cleaning of Harbux Stadium Swimming Pool of size 50 m x 21 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.
Cleaning of Harbux Stadium Deep Diving Pool of size 16 m x 16 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.
Cleaning of Harbux Stadium Baby Pool of size 6 m x 4 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.
(Note for item Ser No 9 to 16 : Quoted rates shall be included for providing manpower and required cleaning material,safety gears and ladders etc required at site for drain out the swimming pools de-watering on completion of Operation and Maintenance of swimming pools)
Supply and fixing in replacement Butterfly valves including with jointing materials, rubber gaskets, old worn out nut-bolts, washers etc complete all as specified and as directed. For the following sizes:- (Note :- Old unserviceable material butter fly obtained after demolition shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm dia
150 mm dia
200 mm dia
Supply , fixing, jointing and testing in replacement of Cast Iron Non-Return Valve without bypass arrangement, swing type, confirming to IS-5312, flanged ends pressure rating PN 1.0 including taking out old unsv NRV from the existing place of following sizes:- (Note :- Old unserviceable material NRV shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm dia
150 mm dia
200 mm dia
Supply, fixing, jointing and testing in replacement of Cast Iron Sluice Valve of sizes as under ISI Marked , flanged ends drilled pressure rating PN-1.6 PD Short body, confirming to IS 14846-2000 having stainless steel spindle with cast iron operation wheel at top including taking out unsv Sluice Valve complete all as specified and as directed for the following sizes:- (Note :- Old unserviceable material sluice valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm dia
150 mm dia
200 mm dia
(Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Genuine PV's & MTC of sluice vavle be produced by contractor alongwith RAR for payment.)
Taking down/out including opening of Pumping set of capacity of 7.5 HP to 25 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of tyre coupling & renewal of wornout bearing with & including suitable size SS nuts, bolts and washers etc and other repairs of minor nature and applying two coats of synthetic enamel paint of existing colour or as directed over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed
Taking down/out including opening of Pumping set of capacity above 25 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of tyre coupling & renewal of wornout bearing with & including suitable size SS nuts, bolts and washers etc and other repairs of minor nature and applying two coats of synthetic enamel paint of existing colour or as directed over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory working of pump set complete all as specified and as directed
Taking down/out including opening of Compressor upto 7.5HP at site, carrying out the servicing, greasing, topping up compressor oil of the suitable grade, cleaning of Air filter, replacement of filter element, replacement of suitable size and suitable make bearings, fan belts of same type including suitable size SS nuts, bolts and washers etc and other repairs of minor nature and applying two coats of synthetic enamel paint of existing colour or as directed over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory working of pump set complete all as specified and as directed. (Note for ser item No 20 to 22:- Old U/s material parts obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Material and labour for preparation of steel surfaces and applying painting on steel and iron surfaces on the pool operating equipments, filteration plants with two coat of synthetic enamel paint over a coat of red oxide primer as per existing colour scheme or pattern after preparation of old painted surface of any description over 10 cm in width or girth complete all as specified and directed. (NOTE:- Old paint from the steel structures will be scrapped off completely and the surface will be smoothen with water Emery paper.)
Material and Labour for fabrication in replacement of rusted base frame with MS Channel (MC-25/50/75/100/125) for foundation of centrifugal pump sets including one coat of red oxide primer and two applying two coat of black syenthetic enamel paint and inclduing taking out of old base frame and grouting new frame in the existing grouted bolts and nuts, complete all as specified and as directed. (Note:- (i) The contractor will make sure that the frame fixed is leveled and both pump and motor are fully alligned to work smoothly. (ii) Old U/s material frame work obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing including testing & commissioning of LED tube light fitting integral type suitable for 1 x 18 watts, 220 volts, connector block etc with all accessories internallly prewired and including connecting with twin core flexible copper cable of suitable size including taking down/out old fitting at site complete all as specified and as directed. (Note:- Old U/s material light fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line including MS Flanges and Flange joints complete with jointing materials complete all as specified and directed by Engr-in-Charge for following sizes:- (Note:- Old U/s material MS pipe obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply & fixing including testing & commissioning of CI foot valve of rating PN 1.0 flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve and removed to MES Store yard under contractor's own arangment complete all as specified and directed by Engr-in-Charge for following sizes:- (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old unserviceable material CI foot valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
150 mm bore
200 mm bore
Supply and charging(filling in) in replacement of old worn out/uncleaned/choked filter media in filtration cum recycle plant sutiable for swimming pool approx 5900 kg/filtration plant to maintain filter flow rate 111 M3/Hr as recommended by manufactuere and swimming pool norms including supplying & filling of following Filter media details complete all as specified and directed:- (Note:- (i) Old unserviceable pebbles, quartz sand, pressure gauge, Air release valve & pole etc shall be removed from site to MES store yard under contractor's own arrangement. (ii) Old pebble sand materials shall be taken on charge in 'CUM' and fittings of Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Quartz Media Depth – 915 MM
Quartz Pebbles of 1" – 3/4" size Not less then 100 mm thick layer
Quartz Pebbles of 3/4" to 1/2" size Not less then 100 mm thick layer
Quartz Pebbles of 1/2" to 1/4" size Not less then 100 mm thick layer
Quartz Pebbles of 1/4" to 1/10" size Not less then 100 mm thick layer
Quartz sand of assorted sizes Not less than 900mm thick layer
Making Back wash arrangement functional/repair – Back wash arrangement shall be made through the running water hence arrangement shall be made to facilitate the back washing system.
Replacement of Pressure gauges and flow meters from all Filtration plants – 02 Nos of suitable rating
Repair and replacement of Air release pipe and valve from all filteration plants .
Supply, Installation testing and commissioning of Factory made LT panel board indoor type, dust & Vermin proof fabricated out of 2.00 mm thick CRCA sheet fixed with Angle iron frame of size 1700mmx1600mmx550mm duly powder coated complete using lugs,and glands of cable connection and having epoxy coated copper bus bar 04 wire system of 250 Amp capacity for (Mains & Neutral) mounted on epoxy insulators, prewired with suitable size of PVC insulated multi strand copper conductor cable having independent enclosure for incoming and outgoing electrical connection and cable gland at bottom for incoming and outgoing and locking arrangement on front side and taking down existing LT panel and shifted to MES storeyard under contractor's own arrangement including providing danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint fittings and fixtures as mentioned below:-
Note: -(i) Panel shall be fixed on base made out of PCC (1:3:6) type C2 using 40mm graded aggregate of crushed stone, size of the base shall be as per manufacturer instructions. Cost of the base shall deemed to be included in the unit rate of this item. (ii) Panel drawing shall be approved by Accepting Officer. (iii) The rate quoted deemed included all wiring & connection and testing installation & comissioning work (iv) Make of accessories will be as per CA scpefication & list of make & manufacturer's.
MCCB 250 Amp, Four pole, 415 Volts, 50 HZ 36 KA -01 No.(as incoming)
Digital volt meter (0-500V) - 01 No
Digital Amp Meter (0-250A) - 01 No
Indicating light RED 220 V AC - 01 Set (Set of Three)
Indicating light Yellow 220 V AC - 01 Set (Set of Three)
Indicating light Green 220 V AC - 01 Set (Set of Three)
Protection MCB 6 Amp SP - 03 Nos
CT 250/5 Amp-03 Nos
MCB 63 Amp 10 KA TP C curve - 06 Nos
Power contactor 40 Amp TP (main & Delta) - 10 Nos
Power contactor 32 Amp TP (star) - 05 Nos
BI metal over load relay 20-33 Amp - 05 Nos
Star Delta timer MICRON Series - 05 Nos
Aux.Blocks - 15 Nos
Push button start/stop 220 volt - 10 Nos
Indiacting light On/Off/Trip 220 Volt - 15 Nos
Control MCB SP 6 Amp to 10 KA - 5 Nos
Single Phase prevntor - 5 Nos
Danger plate - 1 No
Copper Bus bar chamber 250 Amp 4 strips - 05 Nos
Enclosure of suitable size - 1 No
M&L cleaning of balancing tank from the bottam and side walls scrubbing with brush for removing fungus and washing with water after removing all the sediments collected at the bottam of balancing tank complete all as spacified and directed
Material and labour testing & commissioning of motor after providing re-winding material copper winding of electric motor of filltration plant,suction sweeper motor, 3 to 25 HP Motor at swimming pools including replacement of ball bearing and dismantling and refixing, connection, testing etc complete all as specified and directed by Engr-in Charge. (Note:- (i) Old unserviceable re-winding copper shall be removed to MES store yard by contractor's own arrangement and it shall be taken on charge in 'KG' (KG) shall be taken into account and attach with RAR/F Bill) (ii) Testing & commissioning of motor shall be carried out from approved work shop with RAR. (iii) A BOO will be ordered for preparation of inventory and approved & concured by GE.
M&L applying two coat of apply synthetic enamel paint with one coat of spray painting of approved colour to LT pannel, pumps and motors of any size complete including MS/CI pipe line and valves etc complete including prepration of old painted surface complete all as specified and directed.
Testing of Swimming pool in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 3328 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for swimming pools purposes. (ii) Collection of water from different sources of water ie. swimming pools in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification Note :- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source swimming pool.
M&L Framed work such as in grills, grating, angle Iron, MS strip, MS Sheet upto 3 mm, etc with ends of bars, shoulder or revetted or forged into spike frame,guard bars barred iron door,railing frame or similar work and locking arrangement including cutting, drilling , welding and painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed by Engineer-in-charge. (Note:- Old U/s material iron scrap obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
M&L for sign board made out of 2mm thick in Radium Paint sheet steel of size 120x90 Cms painted both side with over a coat of red oxide primer and writing both side Swimming pool with pool name given by Engr-in-charge, GE (U) water supply Delhi cantt-10" with white paint over approved painted back ground and embedded in PCC 1:3:6 type C2 of 30cmx30cm x 30 cm at 2 mtr height above ground level complete with stainless steel pipe of SS-304 grade of 40 mm including taking down old unsv sign board complete all as specified and directed by Engr-in-charge. (Note:- Old U/s iron scrap obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
S & F of 1000 ltrs PVC under ground tank tripple layer in and including complete all fittings etc including taking down old unsv complete all as specified and directed. (Note:- Old PVC tank shall be removed to MES store yard at his own arrangement and taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and fix in replacement of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI light bolt nuts, check nuts and washers of including providing earth wire protection pipe GI light grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore GI pipe medium grade with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0 using MS TMT 8mm dia @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed.
(Note:- (i) Test report of each earthing shall be produced by contractor during payment.. (ii) GI strip 32x6mm upto 7.5RM from earth test point shall be deemed included in quotted unit rate. (iii) Old unserviceable brick/brick bats shall be taken on charge in 'CUM' & iron scrap in 'KG' shall be taken into account and attach with RAR/F Bill). (iv) Old unserviceable material shall be removed upto MES store yard by contractor at his own arrangement.
Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 2 mm thick CRCA sheet, factory made (CPRI approved manufacturer) powder coated painted as approved colour, copper bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 350 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB, complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going LT cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc for suitable to in and including accomodate the following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete:-
200Amp 36 KA 4 Pole 1 No - Incoming MCCB's
63A 25 KA 3 Pole 2 No - Outgoing MCCB's
63 Amps 3 Phase Auto Phase Sequence Corrector - 1 No
Thermal Over load relay 1 No - outgoing
ST 100 Timer 2 Nos - outgoing
ML2 FASD (Heavy duty 35 HP relay range 13-21 A) - 02 Nos for outgoing
(Note :- (i) Contractor shall be take approval of Accepting Officer for panel drawing before fabrication work. (ii) Old unserviceable panel shall be shifted to MES storeyard under contractor's own arrangement and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.) (iii) Test report of panel shall be submitted by contractor alongwith Tax Invoice & e-way bill for payment of RAR.
M & L for earthing in replacement GI plate 60×60cm ×3.15mm thick electrode and 32x6mm galvanised strip as earthing lead thick buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level, connected to copper strip of size 25x4mm as earth lead by means of bolts, nuts and washers madeout of copper or tinned brass and protection GI pipe of 40mm dia all as specified and testing complete including earthwork, PCC chamber, RCC chamber cover with handle GI watering pipe 20mm dia, GI funnel with wire mesh, magnesium sulphate, salt, charcoal, lugs etc and method of earthing shall be as per plate No :3 of SSR part -I complete all as specified and as directed. (Note :- (i) Contractor shall be take approval of Accepting Officer for panel drawing before fabrication work. (ii) Old unserviceable panel shall be shifted to MES storeyard under contractor's own arrangement and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.) (iii) Test report of panel shall be submitted by contractor alongwith Tax Invoice & e-way bill for payment of RAR.
S&F in replacement LED Flood light fitting 100 watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting etc complete fixed bracket & suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from flood light to fittings connector complete all as specified and directed
S&F in replacement LED Flood light fitting 150 watt energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site
S&F in replacement LED Flood light fitting 120 watt energy saving environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site.
S&F in replacement Energy saving flood light 30 Watt environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site. (Note:- (i) Old U/s fittings material shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill) (ii) Old unserviceable fittings shall be removed to MES storeyard under his own arrangement.
Supply and fixing in replacement FRLS PVC insulated industrial grade copper conductor wire of following size, 1100 volts complete all as specified and as directed. (Note:- Old U/s copper conductor material obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
4.00 sqmm, single core
16.00 sqmm, single core
25.00 sqmm, single core
Supply, installation and testing flanged ends strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site by the Engr-in-Charge. (Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old unserviceable stainer shall be shifted to MES storeyard under contractor's own arrangement and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
150 mm bore
200 mm bore
Supply and Fixing in replacement wooden base brush as per existing old sample suitable for suction sweeper assembly with nylon hair brush with bristles of length 7 cm and 1mm dia each complete all as specified and directed. (Note:- Old U/s wooden material shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and Fixing in replacement FPBC nylon flexible hose pipe 40mm outer dia size heavy duty capacity suitable for suction sweeper complete all as specified and directed. (Note:- Old U/s FPBC nylon hose pipe material obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
Microsys Controls India
B.R. Enterprises
Anandeshwar Enterprises
KUSHAL ENTERPRISES
Surjit and Sons
BHUMICA CONSTRUCTION
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .