| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹24.2 L+₹1.6 L (6.92%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹24.4 L+₹1.7 L (7.54%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹24.6 L+₹1.9 L (8.45%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | L5₹25.2 L+₹2.5 L (11.0%)Rejected-Finance NARMADA COLONY BARADARI CHOURAHA MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Sept 2021, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
8700/GWL/E8 REPAIR AND MAINT OF LT PANELS, OH LINES, STREET LIGHTS AND CONNECTED WORKS AT MORAR CANTT UNDER GE GWALIOR
2021_MES_470920_1
8700/GWL/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹80,000
Yes
27 Oct 2021
26 Aug 2021
1 Oct 2021
26 Aug 2021
24 Sept 2021
10 Sept 2021
Amount
Excavation in tenches not exceeding 1.5m wide and not exc 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
M&L for sand cushioning in trenches for cable protection including consolidation complete all as directed.
M&L for Sub class 'B' bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified and directed by engr in charge.
Dismantling of cross arms of MS channel or angle iron sections etc complete and setting aside all as specified and directed.
Dismantling of insulators any type any size
Dismantling steel earth wire from existing overhead service feeder etc all as specified and directed.
Dismantling ACSR conductor of any size from existing overhead service feeder etc all as specified and directed.
M&L in repair and fixing of ACSR conductor on existing or new poles all as directed.
M & L for cross arms, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and as directed.
S&F shakle type Insulator (single disc assembly) porcelain vitreous, white brown or green 75 mm height and 100 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 1100 volt grade complete.
S&F Insulator pin type epoxy insulators vitreous, white brown or green including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 1100 volt grade complete.
M&L for loop type insulator, vitreous porcelain white ,brown or green large size over all dimension 90 X 140mm, clearance of the hole 25.5mm for stay assembly complete all as specified and directed.
M&L for stay assembly with 20mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete measured separately) all as directed.
M & L for galvanized steel wire with 4 mm dia as in cradle guard including dismantling old unserviceable cradle guard complete all as specified and as directed.
S&F in repair of panel door alongwith 300mm, ordinary rat tail rod pattern springs including roller and roller plate with necessary welding on the spot all as specified and directed.
Supply, laying, jointing and testing, XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of size 3.5 core 120 Sqmm
All as per item No. 18 but 95 Sqmm 3.5 core.
All as per item No. 18 but 70 Sqmm 3.5 core.
All as per item No. 18 but 50 Sqmm 3.5 core.
All as per item No. 18 but 35 Sqmm 3.5 core.
All as per item No. 18 but 25 Sqmm 3.5 core.
All as per item No. 18 but 16 Sqmm 4 core.
Dismantling the existing worn out jumpers of two pole/four pole structure and replacing with new set of jumpers of ACSR Conductor of size 6/1x2.59 from overhead line to AB switch, edge fuse and transformer incl PVC RYB sleeves aluminium thimbles etc complete.
M&L for vice type connectors consisting of two brass plates, and two steel bolts and nuts for 2 conductors of equal or unequal sizes for non-tension connections including treatment of connector and ACSR conductor with conductor jolly of size 10 to 13 mm.
Spray of agricultural based chemical inside the installation to control the growth of unwanted herb etc incl cleaning of the grass herbs bushes etc from the installation complete.
Felling of trees not exc 30 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance of exc 100 m and clearing site.
Restringing and stretching of existing sagged LT/HT ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connection complete all as directed.
M & L for overhead line spacers/separators made of cpvc 1/2" pipe, 300 mm long fixed with MS shade/clamp at both end of fixing the ACSR conductors complete fixing with insulators as per sample incl taking down old unsv one all as specified and directed.
M & L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 80 mm dia all as specified and directed.
M&L for HT/LT cable route indicator precast made from PCC 1:3:6 of size 600mm x 230mm x 100 including excavation PCC for foundation and painting and writing as "11 kv cable" incl preparation of surfaces both sides all as specified and directed.
Boring of holes under road, pavement, hard standing by trenches technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4 mpa working pressure.
S&F MS rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewissed . N exc 15 cm long of size 20 mm dia all as specified and directed by Engr-in-Charge.
M & L in replacement of MCCBs 400 Amps, 415 volts, 4 pole rupturing capacity 25 KA in existing LT panel including making existing electrical connection as per existing system all as specified and directed.
All as per item No 35 but of capacity 350 Amps.
All as per item No 35 but of capacity 250 Amps.
All as per item No 35 but of capacity 200 Amps.
All as per item No 35 but of capacity 160 Amps, rupturing capacity 25 KA.
M & L for painting of existing LT panel (Inside/outside) of any size with one coat of synthetic enamel paint as per exisitng over two coat of red oxide primer complete including fabrication work reqd (as welding works, making of locking arrangement, replacement of hinges etc, replacment of doors) complete all as specified and directed
Supply only hadraulic crimping tool, range 10 to 300 sqmm all as specified and directed.
M&L for repair, servicing, checking and testing of capacitor bank panel.
S&F aluminium terminal heavy duty-BS-4579 for following sizes :
Taking down existing old US XLPE UG cable of size upto 16/25 Sqmm x 4 Core.
Taking down old unserviceable street light fitting from pole alongwith accessories for repair & discarded all as specified and as directed by Engr-in-Charge.
Supply and fixing XLPE insulated heavy duty Aerial bunched cable aluminium conductor as per IS 7098 PT-2/IEC-60502/IS-14255 with necessary crimping arrangement with existing pole of size 4 x 16 Core with 16 Sqmm messenger wire.
Supply and fixing dead end clamp suitable for hanging AB conductor of size 16 Sqmm.
Supply and fixing suspension clamp, eye hook and pole clamp suitable for hanging AB conductor of size 16 Sqmm.
Supply and fixing insulation piercing conductor suitable for AB Conductor of size 16 Sqmm.
Repair & replacement of driver for LED street light fittings of capacity upto 72 Watt all as specified and directed.
Taking down and replacement PVC line connectors, 230 Volts, 20 Amp capacity including replacement of 1.5 Sqmm single core PVC insulated aluminium wire of length to phase and neutral.
Refixing of repaired street light fitting alongwith repalcement of PVC line connectors, 230 Volts, 20 Amp capacity including replacement of 1.5 Sqmm single core PVC insulated aluminium wire of length to phase and neutral.
M&L for checking of non functional street light and minor repair with fresh connection all as specified and directed.
M&L replacement of burnt 3 phase aluminium bus bar strip in street light junction box as per existing size and capacity all as specified and directed.
M&L for dismantling & replacement of burnt PVC/porceline post insulator by epoxy post insulators all as specified and directed.
Restringing and stretching of existing sagged LT/HT ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connection complete all as directed.
Supply and fixing in repair GI Bracket made of 40mm dia GI Pipe medium grade 1.2 mtr long suitable for streetlight for steel/RCC Pole as per site requirement including suitable nut, bold, washers and clamps complete accessories all as specified and directed including taking down old one.
Supply and fix in repair of US street light timer and supply & fixing in repairs of automatic street light/security light switch using nature switch for automatic switching of street lights base on LUX level of Natural light. The infrared sensor based nature switch alongwith suitable power contactors and MCBs (Input-Output) should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54. The contacor, MCB and copper circuit wiring (min 10 Sqmm) should suitable enough to take 3 phase load of 8 KW, contactor rating 25-32 Amps per phase, MCB (SP) RATING 32 Amps (03 Nos). Note: Contractor are adviced to visit the site to assess the quantom of work required to repair the existing equipments. The Make of defective parts shall be as per existing make.
Supply only driver's suitable for LED Street light fittings of 70/72 Watt all as specified and directed.
All as per item No. 62 but of capacity 60 watt LED lights.
All as per item No. 62 but of capacity 45/48 watt LED lights.
Supply and fixing of 72 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure dia cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP 66 protection and impact resistance of IK 07 with 10 KV Built-in-SPD.
Supply & Fixing junction box of size 230mm x 170mm x 105mm made of polycarbonate with IP 65 degree of protection (EN60529), dust proof, water tight, light weight, acid resistant, corrosion proof inslated & shock proof, fire retardant, self extinguishing, halogen & silica free non-toxic material, UV resistant, with internally ebbedded gasket fitted with required terminals, should have to be type test certificate and veryfied by glow-wire test in accordance with IEC60695-2-11.
M&L in repair for wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed copper conductor FRLS cable upto and including 1100 V grade drawn through PVC rigid conduit medium grade fixed to wall / ceiling / pole etc including one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed copper conductor FRLS cable as earth wire and duly connected to common earth point including necessary clamps all as specified and directed including taking down old unserviceable sub main wiring .
M/s Sagar Construction
M/S STEAD FAST
M/s Shanti Enterprises
M/s Tirupati construction
AUTOMATION AND SWITCHGEAR CONTROL
Om Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .