| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.9 CrAdmitted-Finance | ₹65.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹67.9 CrAdmitted-Finance | ₹67.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹75.3 CrAdmitted-Finance L 29 BARAMUNDA HOUSING BOARD COLONY BHUBANESWAR PIN 751003 | BHUBANESWAR | KHORDHA | ODISHA | 751003 | ₹75.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹79.1 CrAdmitted-Finance PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARAHILLS HYDERABAD HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | ₹79.1 Cr | L4 | Admitted-Finance |
| 5 | L5₹84.1 CrAdmitted-Finance | ₹84.1 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DNC Infrastructure Private Limited L1 | SRICO PROJECTS PVT LTD L4 | DILLIP CONSTRUCTIONS PVT LTD L3 | M/s. PLCOMM INFRA LLP L6 | M/s. PSK Engineering Construction & Co L5 | unique infra engineers pvt ltd L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared with supply of all labour, T&P , machinery POL, taking all safety measures etc all complete as per the direction of Engineer-in-charge ( Excluding GST) | 17,981.1 | sqm | 10 ₹1.8 L | 13 ₹2.3 L | 10 ₹1.8 L | 10 ₹1.8 L | 9 ₹1.6 L | 8.88 ₹1.6 L |
| 2.00 | Water proofing to concrete elements in contact with soil by applying 2 coats of bitumen paint, Such as Sides of Plinth Beam/Tie beams etc with supply of all materials, labour, T&P , machinery POL, taking all safety measures etc all complete as per the direction of Engineer-in-charge ( Excluding GST) | 5,749.12 | sqm | 100 ₹5.7 L | 130 ₹7.5 L | 200 ₹11.5 L | 150 ₹8.6 L | 135 ₹7.8 L | 110.07 ₹6.3 L |
| 3.00 | Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, with supply of all materials, labour, T&P , machinery etc all complete as per the direction of Engineer-in-charge ( Excluding GST) | 9,530.6 | cum | 356 ₹33.9 L | 208 ₹19.8 L | 300 ₹28.6 L | 450 ₹42.9 L | 350 ₹33.4 L | 369.95 ₹35.3 L |
| 4.00 | Providing pre-constructional Anti-Termite treatment Including supplying chemical emulsion Chlorpyrifos emulsifiable concentrate 20% by diluting and spraying it with supply of all materials, labour, T&P , machinery etc all complete as per the direction of Engineer-in-charge ( Excluding GST) | 5,427.45 | sqm | 160 ₹8.7 L | 177 ₹9.6 L | 160 ₹8.7 L | 232 ₹12.6 L | 180 ₹9.8 L | 182.72 ₹9.9 L |
| 5.00 | Filling the area with saline sand or dredge spoil collecting from port quarry within a lead of 5.00KM as per required level in layer wise ,each layer not exceed 0.3mtr, filling with head loads if required the filling surface properly watering,compacting with supply of all labour,T&P,transportation,royalities , hire and running charges of machinery etc all complete as per the direction of Engineer-in-charge ( 10% shall be deducted from the measured quantity towards voids ) ( Excluding GST) | 53,487.65 | cum | 246 ₹1.3 Cr | 512 ₹2.7 Cr | 450 ₹2.4 Cr | 450 ₹2.4 Cr | 350 ₹1.9 Cr | 255.74 ₹1.4 Cr |
| 6.00Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-35 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 750 mm dia piles with supply of all labour,T&P,transportation,royalities , hire and running charges of machinery etc all complete as per the direction of Engineer-in-charge ( Excluding GST) | |||||||||
| 6.01 | 750 mm dia piles | 13,275 | Rm | 3,422 ₹4.5 Cr | 6,146 ₹8.2 Cr | 4,500 ₹6.0 Cr | 7,300 ₹9.7 Cr | 7,000 ₹9.3 Cr | 3,552.69 ₹4.7 Cr |
| 6.02 | 500 mm dia piles | 675 | Rm | 1,963 ₹13.3 L | 3,558 ₹24.0 L | 4,000 ₹27 L | 4,500 ₹30.4 L | 4,150 ₹28.0 L | 2,241.53 ₹15.1 L |
| 7.00 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test with supply of all labour,T&P,transportation,royalities , hire and running charges of machinery etc all complete as per the direction of Engineer-in-charge Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.
Group of two or more piles upto 50 tonne Safe capacity.
Initial test (Test Load 2.5 times the Safe capacity)( Excluding GST) | 12 | no | 56,925 ₹6.8 L | 58,805 ₹7.1 L | 1,00,000 ₹12 L | 82,000 ₹9.8 L | 80,000 ₹9.6 L | 65,008.35 ₹7.8 L |
| 8.00 | P.C.C(1:2:4) of using 20 mm. & down C.B.G chips of approved quality in foundation & plinth including mixing hosting, laying to proper level & slope consolidating, curing, watering charges etc. complete including cost & supply of all materials, labour, T&P, taxes, etc. complete but excluding cost of GST as directed by Engineer-in-charge | 652.43 | cum | 7,000 ₹45.7 L | 6,078 ₹39.7 L | 5,000 ₹32.6 L | 8,000 ₹52.2 L | 7,200 ₹47.0 L | 7,254.34 ₹47.3 L |
Tender Value
₹61.7 Cr
EMD Value
₹71.7 L
Closing Date
16 Dec 2023, 6:00 pmClosed
EE,R and B,PPA
Office of the Roads and Building Division Engineering Department, Paradip Port Authority, Ground Floor, Administrative Building, Ph-06722-222357 , Mob-9437120010
CONSTRUCTION OF 350 QTRS. FOR PORT EMPLOYEES AND ALSO TO FACILITATE AND RESERVE LAND FOR THE FUTURE EXPANSION OF THE PORT IN NUABAZAR AREA-1ST PHASE (91 QTRS)
2023_MoS_775897_1
CE/RandB/ACCTS-72/19( Pt-III) /349
Open Tender
Civil Works
540 days
Paradip
Please refer Tender documents.
3 documents required · 3 mandatory
₹25,000
Yes
As per eTCN and TD
₹71.7 L
Yes
Office of the CE,PPA
2 Feb 2024
12 Oct 2023
18 Dec 2023
12 Oct 2023
16 Dec 2023
12 Oct 2023
12 Oct 2023 - 25 Oct 2023
31 Oct 2023
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared with supply of all labour, T&P , machinery POL, taking all safety measures etc all complete as per the direction of Engineer-in-charge ( Excluding GST)
Water proofing to concrete elements in contact with soil by applying 2 coats of bitumen paint, Such as Sides of Plinth Beam/Tie beams etc with supply of all materials, labour, T&P , machinery POL, taking all safety measures etc all complete as per the direction of Engineer-in-charge ( Excluding GST)
Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, with supply of all materials, labour, T&P , machinery etc all complete as per the direction of Engineer-in-charge ( Excluding GST)
Providing pre-constructional Anti-Termite treatment Including supplying chemical emulsion Chlorpyrifos emulsifiable concentrate 20% by diluting and spraying it with supply of all materials, labour, T&P , machinery etc all complete as per the direction of Engineer-in-charge ( Excluding GST)
Filling the area with saline sand or dredge spoil collecting from port quarry within a lead of 5.00KM as per required level in layer wise ,each layer not exceed 0.3mtr, filling with head loads if required the filling surface properly watering,compacting with supply of all labour,T&P,transportation,royalities , hire and running charges of machinery etc all complete as per the direction of Engineer-in-charge ( 10% shall be deducted from the measured quantity towards voids ) ( Excluding GST)
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-35 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 750 mm dia piles with supply of all labour,T&P,transportation,royalities , hire and running charges of machinery etc all complete as per the direction of Engineer-in-charge ( Excluding GST)
750 mm dia piles
500 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test with supply of all labour,T&P,transportation,royalities , hire and running charges of machinery etc all complete as per the direction of Engineer-in-charge Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity. Initial test (Test Load 2.5 times the Safe capacity)( Excluding GST)
P.C.C(1:2:4) of using 20 mm. & down C.B.G chips of approved quality in foundation & plinth including mixing hosting, laying to proper level & slope consolidating, curing, watering charges etc. complete including cost & supply of all materials, labour, T&P, taxes, etc. complete but excluding cost of GST as directed by Engineer-in-charge
Providing Plain Cement Concrete M15 using 10mm to 40mm well graded machine crushed granite chips from approved quarry including cost and conveyance of all materials to site, centering, shuttering, machine mixing, laying concrete, vibrating, finishing smooth to required levels, curing, all other incidental and operational charges, labour charges,etc., complete for RCC box drains, rotary drain and collection chamber at rotary island as per MORTH specification sections 1500,1600&1700 with supply of all labour,T&P,transportation,royalities , hire and running charges of machinery etc all complete as per the direction of Engineer-in-charge ( Excluding GST)
Providing Reinforced Cement Concrete M20 grade Design Mix With Minimum Cement Content of 347 Kg using 20mm size well graded machine crushed granite chips from approved quarry including cost and conveyance of all materials (Viz) cement, sand, stone aggregate, water etc., to site, centering, shuttering, machine mixing, laying concrete, vibrating, finishing smooth to required levels, curing, all other incidntal and operational charges, labour charges, , etc., complete for finished item of work for Side Walls per MORTH specification 1500,1700&2100 (Box Type)with cost and supply of all materials, labour, T&P, taxes, tollage, royalties,etc. all complete but Excluding GST as directed by Engineer-in-charge.
C.C. M 35 for R.C.C. works using 20mm and 10 mm size C.B.G. chips for all floors, foundation & plinth etc. of approved quality, mixing with a concrete mixture as per approved design mix, hoisting, laying, compacting with40 to 60 needle vibrator, curing with cost and supply of all materials, labour, T&P, taxes, tollage, royalties,etc. all complete but Excluding GST as directed by Engineer-in-charge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
C.C. M 40 for R.C.C. works using 20mm and 10 mm size C.B.G. chips for all floors, foundation & plinth etc. of approved quality, mixing with a concrete mixture as per approved design mix, hoisting, laying, compacting with40 to 60 needle vibrator, curing with cost and supply of all materials, labour, T&P, taxes, tollage, royalties,etc. all complete but Excluding GST as directed by Engineer-in-charge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Shoring and shuttering for foundation trenches, pits etc. with supply of 38 mm thick non sal planks for poling boards and 10 mm thick non sal planks for walling and 125 mm dia non sal bullah for struting including putting close the wooden planks sheets for protection of excaveted earth pit with supply of all labour materials T&P, taxes, tollage, royalities etc all complete but excluding cost of GST as directed by EIC .
Supply Tor/TMT steel manufactured by SAIL/TISCON/VIGAC Steel of Fe- 550D confirming to IS-1786 including cutting, straightening, bending, binding & placing the grills in position for RCC works binding the grills with binding wire of 18 to 20 gauge including supply of steel, labour, materials, transportation charges, T&P, taxes, etc. all complete but excluding GST as per the direction of Engineer-in-charge. (NB: No payment shall be made for extra weight than theoretical co-efficient).
Providing rigid smooth leak proof centering & shuttering made of steel/ply, plank of approved quality for R.C.C. structures and deshuttering and removing the same after due period with supply of all materials, labour, T&P, taxes, royalties, tollage, etc. all complete but excluding GST as directed by Engineer-in-charge.
RCC Foundation and footing base of Columns mass concrete & Precast Slab etc
Beam, column, girder
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
RCC wall & fins
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Roof slab, landing, projection Chajja upto 4.30 mtr.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
RCC Stairs excluding landing but including railings
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Providing and laying autoclaved aerated cement blocks masonry with 100mm thick AAC blocks in super structure above plinth level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar with suipply of all materials ,labour, T&P etc all complete as per the direction of Engineer-in -charge . (The payment of RCC band and reinforcement shall be made for seperately) ( Excluding GST)
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Providing and laying autoclaved aerated cement blocks masonry with 200mm thick AAC blocks in super structure above plinth level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar with suipply of all materials ,labour, T&P etc all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).( Excluding GST)
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) with supply of all materials ,labour ,T&P etc al complete as per the direction ogf Engineer-in-charge ( Excluding GST)
Providing and laying water proofing treatment in trench etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry with supply of all materials ,labour ,T&P etc al complete as per the direction ogf Engineer-in-charge ( Excluding GST)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.( Excluding GST)
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete with supply of all materials ,labour ,T&P etc al complete as per the direction ogf Engineer-in-charge ( Excluding GST)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube with supply of all materials ,labour ,T&P etc al complete as per the direction ogf Engineer-in-charge ( Excluding GST)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer with supply of all materials ,labour ,T&P etc al complete as per the direction ogf Engineer-in-charge ( Excluding GST)
providing fitting and fixing the fabricted MS structures after cutting, bending, making holes, jointing ,welding as per requirement and Hoisting fabricated structurals, placing in position as per the drawings or as directed with supply of labour and material,machinery, cost of fuel, electrode, gas, consumables hire and running charges of all kind of equipments etc all complete as per direction of Engineer-in-charge.
Supplying, fitting, fixing Second class teak wood frame choukaths for doors, windows, ventilators, coaltaring two coats to wall side face of frame, fixing to position with required nos. of W.I. clamps of size 25cm to 30cm long, 35mm wide, 2mm to 3 mm thick in C.C(1:3:6) including cutting grooves in choukaths, jointing with adhesive solution fixing to proper position etc. all complete including cost and supply of all materials, labour, T&P, all taxes, transportation, staging, scaffolding etc. complete as directed by the Engineer-in-charge.
Supply of 32mm thick single leaf Second class teak wood with antitermite treated paneled Door shutters having both side styled moulded having bottom rail of 200 mm thick, top rail 100mm thick , middle lock rail 200 mm thick alongwith straight vertical moulded style of 125mm width (total 2 panels) and panel should be 20 mm thick piasal plank embedded 16mm to styles & rails with one no of aluminum aldrop of size 300mm x 16mm x 40mm, two nos of 150 mm with 175mm x 40mm flat aluminum handles, 2 nos. of 200 mm x 10mm aluminum tower bolts and required numbers of wooden hinged cleats, fixing at position etc all complete . including cost of all materials, labour, loading & unloading Charges, all taxes, transportation charges, stacking at site store etc. all complete as directed by Engineer In- Charge.(Excluding GST) N.B.- Size & design decided by the department as per requirement at site.
Supplying, fitting, fixing Sal wood frame choukaths for doors, windows, ventilators, coaltaring two coats to wall side face of frame, fixing to position with required nos. of W.I. clamps of size 25cm to 30cm long, 35mm wide, 2mm to 3 mm thick in C.C(1:3:6) including cutting grooves in choukaths, jointing with adhesive solution fixing to proper position etc. all complete including cost and supply of all materials, labour, T&P, all taxes, transportation, staging, scaffolding etc. complete as directed by the Engineer-in-charge..(Excluding GST)
Supply of 32mm thick single leaf seasoned piasal wood with antitermite treated paneled Door shutters having both side styled moulded having bottom rail of 200 mm thick, top rail 100mm thick , middle lock rail 200 mm thick alongwith straight vertical moulded style of 125mm width (total 2 panels) and panel should be 20 mm thick piasal plank embedded 16mm to styles & rails with one no of aluminum aldrop of size 300mm x 16mm x 40mm, two nos of 150 mm with 175mm x 40mm flat aluminum handles, 2 nos. of 200 mm x 10mm aluminum tower bolts and required numbers of wooden hinged cleats, fixing at position etc all complete . including cost of all materials, labour, loading & unloading Charges, all taxes, transportation charges, stacking at site store etc. all complete as directed by Engineer In- Charge.(Excluding GST) N.B.- Size & design decided by the department as per requirement at site.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 45 x 70 mm (Excluding GST)
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick (Excluding GST)
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge.(Excluding GST)
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge.(Excluding GST)
Providing and fixing of Aluminium sliding door using Jindal Deluxe 27mm series 3track and 4 track with all necessary accessories. including supply and fixing of 6mm thick clear Toughend glass with necessary including the cost of Door closer for door shutters.weather sealant - all complete (Excluding GST)
Proividing and fixing of Aluminium framed Glass door cum fixed ùsing 63 x 38mm sections as outer frames and 48x45mm sections as glass shutter frames with necessary accessories including supply and fixing of 6mm thick clear toughened glass including the cost of Door closer for door shutters. - all complete with lock arrangements (Excluding GST)
proividing and fixing of Aluminium framed Lvr door ùsing 63 x 38mm sections as outer frames and 48x45mm sections as door shutter frames alongwith 103mm wide Z type extruded louver sections assembled with 48mm wide flat alongwith necessary accessories - all complete lock arrrangements (Excluding GST)
Supplying, fitting, fixing up AL window (sliding type) made up aluminum Section 9778 as window fram, section No. 4095, 4096 & 9777, 3994 as shutter frame with 5mm thick black glass as panel fitted with rubber bending including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-in-charge.(Excluding GST)
Supplying fitting fixing of 6.5mm to 6.7mm thick ceramic wall tiles ( premimum Quality 300 x 300 mm) and cutting to required size as approved by EIC in floors, treads or steps and landing on 12mm thick bed of cement mortar 1:3(1cement: 3 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and cleaning complete including supply of all labour material taxes tollage etc all complete but excluding GST as per direction of Engineer in charge (Excluding GST)
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Supplying fitting fixing of 8mm thick ceramic floor tiles ( premimum Quality 300 x300 mm or 400 x 400 mm size) and cutting to required sizein floors, treads or steps and landing on 20 mm thick bed of cement mortar 1:4(1cement: 4 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and cleaning complete including supply of all labour material taxes tollage etc all complete but excluding GST as per direction of Engineer in charge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Supplying fitting fixing of 10mm thick double charged Vitrified floor tiles ( premimum Quality 600 x600 mm size) and cutting to required sizein floors, treads or steps, risers, skirtings and landing on 20 mm thick bed of cement mortar 1:4(1cement: 4 sand) jointed with white cement including rubbing and cleaning complete including supply of all labour material taxes tollage etc all complete but excluding GST as per direction of Engineer in charge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Providing and laying Polished Granite stone in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.( Excluding GST)
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Providing and laying Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) etc. all complete as specified and as directed by the Engineer-in-Charge.( Excluding GST)
Providing and laying Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (Slopped skirting as per the architectural drawing) etc. all complete as specified and as directed by the Engineer-in-Charge.( Excluding GST)
12 MM thick Cement plaster with cement mortar (1:4) proportion, over brick work including racking out the joints, finished smooth to the exposed surface, rounding the corners wherever found necessary including cost & supply of all materials, labour, T&P, staging, scaffolding, watering, curing, taxes,tollage, royalties, etc. complete but excluding GST as per direction of Engineer-in-charge
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
6 MM thick Cement plaster with cement mortar (1:4) proportion, over RCC work including racking out the joints, finished smooth to the exposed surface, rounding the corners wherever found necessary including cost & supply of all materials, labour, T&P, staging, scaffolding, watering, curing, taxes, tollage, royalties, etc. complete but excluding cost of GST as per direction of Engineer-in-charge
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) over RCC work and others including racking out the joints, finished smooth to the exposed surface, rounding the corners wherever found necessary including cost & supply of all materials, labour, T&P, staging, scaffolding, watering, curing, taxes, tollage, royalties, etc. complete but excluding cost of GST as per direction of Engineer-in-charge
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
one coat Priming with water bond cement primer to the newly plaster surface of the exterior Wall or over the exisitng putty surface of the interior wall of approved make & shade to make an even finished surface in all heights with all scaffolding and staging including cost and supply of all materials, labour, T&P, all taxes, transportation charges, staging, scaffolding, etc. complete but excluding GST as per direction of Engineer-incharge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Finishing walls with Acrylic Smooth exterior paint of required shade over new work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in all heights with all scaffolding and staging including cost and supply of all materials, labour, T&P, all taxes, transportation charges, staging, scaffolding, etc. complete but excluding GST as per direction of Engineer-incharge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Two coats wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour in all heights with all scaffolding and staging including cost and supply of all materials, labour, T&P, all taxes, transportation charges, staging, scaffolding, etc. complete but excluding GST as per direction of Engineer-incharge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete in all heights with all scaffolding and staging including cost and supply of all materials, labour, T&P, all taxes, transportation charges, staging, scaffolding, etc. complete but excluding GST as per direction of Engineer-incharge.
Upto stilt floor
For first floor
For second floor
For third floor
For fourth floor
For fifth floor
For sixth floor
For seventh floor
Above seventh floor
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm with supply of all materials,labour ,T&P etc all complete as per the direction of Engineer-in-charge . ( Excluding GST)
Providing and fixing Threshold for doors openings Granite of approved colour or mirror polished marble 30 mm thick - colours matching to the adjoing floors also it should be full width of wall. cutting and nosing , as per architectural drawings and specifications approved by the engineer-in-charge etc.
providing and laying factory made chamfered edged cement concrete paver blocks in footpath, park lawn, drive way or light traffic parking etc. M30 strength and 80 mm thick ,made by table vibratory method using PU mould , laid in required colour & parten over 50 mm thick compacted bed of sand , compacting and proper embedding /laying of inter locking paver blocks into the sand bedding layer throught vibratory compaction by using plate vibrator, filling the joints with sand and cutting the paver blocks as per required size and partern, sweeping the surface etc all complete with supply of material, labour , t&P taxes tollage etc all complete but excluding GST as directed by EIC
Provision of lift for residential appartment of 16 passengers lift up to 8 floors with hairline stainless steel finish inner car and LED light in roof also exhaust fan as per the architectural design approved by the engineer-in-charge etc, complete.
Supplying and fixing of garbage chute approved make as per the architectural drawing and specification approved by the engineer-in-charge etc.
Supplying and Fixing of Wardrobe single side laminate finish and other side vineer finish with all the necessary supports and specfication as per architectural design approved by engineer-in-charge etc.
Supplying and Fixing of 18mm thick BWP marine ply with both side laminated carcass with shutter and auto closed hinges of 180 degree. This carcass units includes the oil pull out, vegetable pull out with chest of drawers with the make of telescopic channel
Supplying and Fixing of wall hung unit using 18mm thick commercial ply with both side laminate with concealed lipping appropriate adjustable shelf .Shutters should be 18 mm thk commercial ply including necessary hardwares such as handles and hinges.
Providing, fitting, fixing up false ceiling of approved design and drawing in all floors with G.I Section on 4 walls to be fixed by means of steel screw and PVC plug and the G.l. grid 2’-0”x2’-0” to be suspended from ceiling by using 12.5mm thick Fire Line Gypsum Board including cost of all materials, all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge
Construction of Subgrade with borrowed useful earth having CBR more than or atleast equal to 8 from outside road boundary by mechanical means up to SDR and lifts including pre-watering of soil at borrow area, removal of top soil, excavation of soils at borrowed area, conveyance of soil, depositing the soil on the embankment, spreading soil, breaking clods, sectioning, grading and consolidation with 8 to 10 Tonnes Vibratory Road Roller @ OMC to meet requirement of table 300-2 of MoRT&H, including all hire and operational charges of T&P complete for finished item of work as per MoRT&H specification 305 (5th revision)
Construction of Granular sub-base by providing HBG material confirming to Grading - III to VI of MoRT&H Table 400-1 and conveyance of all materials to work site and spreading in uniform layers with motor grader or by approved means, on prepared surface mixing by mix in place method with Rotavator / approved means at OMC and compacting with vibratory roller to achieve the desired density etc., complete for finished item of work as per MoRT&H Specification 401 (Fifth revision) and as directed by the Engineer-in-charge.
Providing, laying, spreading and compacting graded HBG crushed stone aggregate with to 250mm compacted thick Wet mix macadam in two layers of 125 mm each as specification confirming to table 400-13 including premixing the material with water at OMC in plant,carriage of mixed material by tipper to site, laying in uniform thickness with paver in base course on well prepared surface and compacting with vibratory roller of 8 to 10Tonnes to achieve the desired density in stages to proper grade and camber,as directed by Engineer-in-charge including cost and conveyance of all materials (viz) stone aggregates of specified sizes,water etc.,labour charges for all operations, hire & operational charges of power roller and other T&P, complete as per Clause No 406 of MORTH for finshed item of work
Providing , laying and consolidation of 95 mm thick Dense Graded Bituminous Macadam with 100 - 120 TPH batch type hot mix plant producing an average output of 75 tones per hour using hard blasted granite crushed aggregates of Grading - I as per table 500-10 of MoRT&H Specification 505 (5th revision) premixed with bituminous binder of VG 30 grade @ 4 to 4.50% of weight of total mixture, transported to site, laid over a previously prepared surface with a hydrostatic paver finisher with sensor control to the required grade, level and alignment and rolled as per Clauses 501.6 and 501.7 to achieve the desired compaction for finished item of work as directed by the Engineer-in-Charge including hire and operational charges all T&P and all other contingent charges necessary including cost of (excluding seigniorage) charges of all materials etc., complete in all respects as directed by Engineer-in-Charge and as per MoRT&H specification No. 505 (5th Revision)
Providing and applying Prime coat with bitumen emulsion of Slow setting(Bulk) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 Kg/Sqmt using mechanical means for finished item of work as directed by Engineer-in-Charge as per technical specification including cost and conveyance of bitumen emulsion, water etc., to site, labour charges, hire and operational charges of all T&P, etc., compelte over WMM as per MORTH Specification No.502
Providing and applying Tack coat using bitumen ermulsion of Medium @ 0.20 kg per sqm on the prepared surface of granular base cleared with mechanical broomer applied uniformly with the aid of emulsion pressure sprayer and spraying bar with nozzles including cost and conveyance of emulsion water etc., labour charges for all operations, hire and operational charges all T&P complete as per MoRT&H specification 503 Complete for finished item of work as directed by the Engineer - In- Charge.
Providing and laying of Bituminous Concrete with 100 - 120 TPH batch type hot mix plant producing an average output of 75 tones per hour using hard blasted granite crushed aggregates of Grading – II as per Table 500-17 of specification 507 of MoRT&H (5th revision), premixed with Bituminous binder of VG 30 Grade @ 5.2 to 5.4 % of mix and filler, transporting the hot mix to work site, laying with hydrostatic sensor paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRT&H Specification 507 (5th revision) complete for finished item of work in all respects as directed by Engineer-in-Charge
Pavement Marking:Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. as per drawing & Technical Specification Clause 803 MORTH Specifications
Providing and fixing 100mm diameter PVC pipe for weep holes in retaining wall, abutment, wing/return wall extending to full depth of the member complete as per Technical Specification clause 2706
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Providing and fixing in position drainage spouts complete as per drawings and Technical Specifications Clause 2705.
Prooviding and fixing main entrance gate complete all specifications as per drawings and as per direction of engineer incharge
Providing and plantation of Trees, Shrubs, and Hedge at Landscaping area i/c watering and removal of unserveiceable material’s as per direction of officer in charge
Proving and preparing of the kids play area as per the drawing specification including the kids play equipments as per the direction of Engineer-in-charge
Proving and installation of signage details as per the drawing specification as per the direction of Engineer-in-charge
Proving and installation of light poles as per the drawing specification and direction of Engineer-in-charge
providing fitting and fixing the fabricted MS structures after cutting, bending, making holes, jointing ,welding as per requirement and Hoisting fabricated structurals, placing in position as per the drawings or as directed with supply of labour and material,machinery, cost of fuel, electrode, gas, consumables hire and running charges of all kind of equipments etc all complete as per direction of Engineer-in-charge.
Mechanical Electrical Plunmbing: Include for the complete Supply, Installation, Testing, Commisioning and handing over as detailed in the Specifications and on the Drawings and to the complete satisfaction and approval of the Engineer and all concerned 'Statutory Authorities and under the following sections
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
100mm diameter.
150mm diameter.
200mm diameter.
Providing and laying in position Masonary Manhole complete with heavy duty CI Manhole cover including earthwork n excavation, dressing complete with internal cement plaster as per the specifications. 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Manhole covers 600x600
Construction brick / block masonry manhole as per standard design in the drawings top RCC cover including reinforcement for heavy loads, polypropylene steps, all complete as per specifications and as directed by the engineer incharge.
1200mm dia
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Gully traps & covers -300x300
Allow for necessary connections to manholes including necessary builders work fixing, fittings, accessories to complete as per Drawings and Specifications.
Providing and fixing pipework accessories, all in accordance with the Drawings and Specification.
UPVC Floor Clean Out & SS covers in various diameters
UPVC Floor Trap SS gratings 110mm diameter.( cockroach & mosquito trap)
UPVC Floor Trap SS gratings 110mm diameter.( floor drain)
UPVC Floor Trap SS gratings 75x63 mmBalcony Drain
UPVC Vent Cowl in various diameters
Providing, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.
32mm diameter. uPVC IS 4985
50/40 mm diameter. uPVC IS 4985
75mm diameter.
110mm diameter.
150mm diameter.
Providing, fixing & testing of UPVC rain water pipes (IS : 4985-1983 class-5 10 Kg/cm2 pressure) including injection moulded fittings (heavy duty) (plain or door) e.g. bends, junction, cowls, tees, offsets, access pieces etc. Clamps/Supports jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good as required at Site.
75mm diameter.
100mm diameter.
Providing and fixing pipework accessories, all in accordance with the Drawings and Specification. Ref. RWO,
Providing and fixing pipework accessories, all in accordance with the Drawings and Specification. RW free discharge
Providing, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.
150mm pipe diameter.
Providing, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.
75mm diameter. (Vent pipe)
150mm diameter.( Soil & waste pipe)
50mm diameter ( Balcony Drain pipe)
Allow for all access doors, rodding eyes and the like as specified and as shown on drawings.
Allow for acoustic insulation to all drainage pipes specified and as shown on drawings.
Providing and fixing water supply incoming line from water supply network - GI heavy duty 160mm dia under ground pipe
Providing and fixing valves and accessories 600x600x600mm for cold water system including all fixings fittings and all other necessary accessories, all in accordance with the Drawings and Specification
Supply & installation of valve chamber including valves
Float Valve With Switch
Auto level indicator
Supply and installation of transfer pump set, balancing pipe works, overhung-impeller, including, Pressure Sensors,Dry run Protection, insulations, Isolating valves, Non-return valve, flexible connection, Strainer valve and all necessary fixings and fittings, accessories, all in accordance with the Drawings and Specification
Cold water Transfer pump sets complete as detailed in drawing and specifications - 3.8 lit/sec@3 bar
Cold water Transfer pump sets complete as detailed in drawing and specifications - 6.0 lit/sec@3 bar
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti- microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on walls & Shaft.
20mm diameter.
25mm diameter.
32 mm diameter.
40 mm diameter.
50mm diameter.
65mm diameter.
75mm diameter.
Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 23 Deg C)for pipes from 1/2 Inch to 2 Inch. Schedule 40 Pipe to be used from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846. ASTM F441 with only CPVC solvent cement conforming to ASTM F-493. - For Hot Water
20mm diameter.
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti- microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
20mm diameter.
Providing and fixing Brass Valves and accessories for hot & cold water system including all fixings fittings and all other necessary accessories, all in accordance with the Drawings and Specification
15mm diameter.
20mm diameter.
25mm diameter.
32mm diameter.
40mm diameter.
50mm diameter.
65mm diameter.
75mm diameter.
80mm diameter.
Brass Float valve 75mm diameter.
Float Switch
Bip taps 20mm Bib tap with valve
20mm Angle valve
Water Hammer Arresrter
Supply and installation of transfer pump set, balancing pipe works, overhung-impeller, including, Pressure Sensors,Dry run Protection, insulations, Isolating valves, Non-return valve, flexible connection, Strainer valve and all necessary fixings and fittings, accessories, all in accordance with the Drawings and Specification
Cold water Transfer pump sets complete as detailed in drawing and specifications - 9.0 lit/sec@3 bar
Supply and installation of booster pump set, balancing pipe works, domestic water booster pumps including, Pressure Sensors,Dry run Protection,insulations, pressure vessels, isolating valves, non-return valves, flexible connection, stainer valves, pressure gauges, and all necessary fixings and accessories, all in accordance with the Drawings and Specification
Cold water booster pumps sets complete as detailed in drawing and specifications - 1.9li/sec@3 bar (1 Duty & 1 Stand by)
Cold water booster pumps sets complete as detailed in drawing and specifications - 2.5li/sec@3 bar (1 Duty & 1 Stand by)
Cold water booster pumps sets complete as detailed in drawing and specifications - 2.5li/sec@3 bar (1 Duty & 1 Stand by)
20mm Bib tap with valve
20mm Angle Valve
Supply and installation of electrical water heaters and all necessary fixings and accessories, all in accordance with the Drawings and Specification
15L electrical water heater
50L electrical water heater
Supply & Installation only of sanitary wares,accessories and all necessary fixings complete with angle valves, mixing valves, connections, fittings, supports, fixation. ...etc.), all in accordance with the Drawings and Specification
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32/40 mm dia
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing toilet paper holder C.P. brass
Robe hook
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers
Counter Basin
Supply, Installation, Testing, Commisioning fans including necessary controls, control wiring, canvas connections, fixing accessories, vibration isolators, etc., complete all in accordance with the Drawing & Specifications
Wall mounted Exhaust Fan EF-01, 175 LPS for kitchen with all accessories.
Wall mounted Exhaust Fan EF-02, 35 LPS for toilets with all accessories.
Wall mounted Exhaust Fan EF-03, 200LPS for garbbage with all accessories.
Wall mounted Exhaust Fan EF-04, 200LPS for garbbage with all accessories.
Supply, Install, testing & commissioning of Splitl unit including fittings, access panels, supports, clamps and control panel;, High pressure drain pipes, extended drain pan, Accoustic lined R32/R410A refrigerant gas, supports, clamps & additional drip tray etc.as specified in the drawings & specification
Split Unit - GF-DSU-01 (1TR) Telephone Rm Ground Floor
Split Unit - GF-DSU-02 (1TR) Electrical Rm Ground Floor
Split Unit - RF-DSU-01 (1TR) Electrical Rm Roof Floor
Supply,Installation, T& C of CU System outdoors units with all required Hard copper piping between the outdoor and indoor units including all the Y-branches, couplers, valves, insulation and foundation etc as specified in the drawings & specification
Out door Unit; Ref - GF-ODU-01 (1TR) Telephone Rm Ground Floor
Out door Unit; Ref - GF-ODU-02 (1TR) Electrical Rm Ground Floor
Out door Unit; Ref - RF-ODU-01 (1TR) Electrical Rm Roof Floor
Supply and install the following fire fighting system as specified to give a complete system that is acceptable to the Engineer, all Local Authorities and in accordance with NFPA standards under the following sections.All pipes crossing walls, RCC slabs etc. shall be provided with sleeves of same material and gap to be filled with approved sealant.
Standard galvanized steel pipe work and ductile iron type threaded fittings for wet riser system, including all necessary supports, pipe sleeves where necessary keyed couplings, fire stops, consumables to complete, all in accordance with the Drawings and Specification.
25mm diameter.
65mm diameter.
100mm diameter.
Air Release Valve with Pressure gauge 25mm diameter.
Gate valve 100mm diameter.
Fire hose cabinet including hose reel with 25mm x 30m and 65mm x 30mm long hose reels, hose racks, pressure restricting type fire hose valves,double head landing valve with 4.5Kg DCP fire extinguisher, 10Lbs dry powder fire extinguisher , pressure gauge and interconnecting pipework and fittings all in accordance with Drawings and Specifications
Fire hose reel cabinet - Surface Mounted finished with Stainless Steel Ref : FHC
Portable fire extinguisher: Wall mounted Carbon dioxide fire extinguishers (5 Kg capacity) with mounting bracket & base
Portable fire extinguisher: Wall mounted ABC dry chemical powder (Multipurpose) fire extinguishers (5 Kg capacity) with mounting bracket & base
2.5Kg Carbon dioxide Dry powder fire extiniguisher
Sand Bucket
Fire Blanket
Fire water booster pump set control panel, gate valves, rising stem isolation valve, flexible connection, pressure relief valve, flow meter, swing type check valves, pumps base, fixing in position with all necessary fittings, supports and accessories, all in accordance with standards, Drawings and Specifications
Fire water booster pump set - 900LPM @ 40m head (1 Duty + 1 Stand by)
Supply and install condensate drain pipes for air conditioning and refrigeration equipment, including all necessary vapour sealed and canvas wrapped, fittings, fixtures, joints, brackets, supports, labelling and the like; complete and connecting to the nearest drain pipe
Supply, fabrication, installation, testing of Interconnecting refrigerant pipe work with closed cell 19mm/13mm thick crosslinked polyethylene (XLPE) tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supports
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete :
1. 200 mm diameter.
2. 250 mm diameter
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 coarse sand) finished with floating coat of neat cement and makingmm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
HDPE pipe work and fittings measured separately for Cold water incoming line, check valve, Gate valve, control valves, installed underground including all necessary supports, fixings and accessories, slab or wall penetrations, expansion loops, recesses and notches where required and all in accordance with the Drawings and Specification.
160mm dia (within the plot limit)
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
Connection to the Under water tank inside plot limit) including float switch, motorized butterfly valve, brass ball valve, auto water level indicator, connection to the control panel including fittings, SS supports, fixings and accessories and connections, complete all in accordance with the Drawings and Specification
Design, manufacture, supply, assembling, installation, test and commission the following Main Distribution Board as per the specifications/drawings/Local Authority Regulations, Complete with all necessary ACB's MCCB's, fuses, switches, earthing etc. including all supporting frame. Complete in all respect and as per direction of Engineer-in-charge..
Design, manufacture, supply, assembling, installation, test and commission of following Capacitor Bank as per specifications, drawings with all harmonic filters, Isolators,Switches, internal wiring, etc. including all accessories.Complete in all respect and as per direction of Engineer-in-charge..
Capacitor Bank 35kVAR
Capacitor Bank 100 KVAR
Design, manufacture, supply, assembling, installation, test and commission of following motor starter panels complete with contactors, relays, protection, push buttons, indicators, voltmeter, ammeter etc. as per specifications, drawings complete with breakers, Isolators,Switches, internal wiring, etc. including all accessories interlocking with level controller. Complete in all respect and as per direction of Engineer-in-charge..
Motor Controller for 10 HP Open well submersible pump
Motor Controller for 5 HP Water Booster pump
Motor Controller for 15 HP Fire Terrace pump
Lift Controller for Lift (15 HP) inluding lift car + well light
Supply, Install, test and commission following types of Sub Main Distribution Boards as per specification, drawings complete with all isolators, MCCB’s, ELCB’s, TPN copper busbars, internal wiring, & KWH Meters etc. including all accessories. Complete in all respect and as per direction of Engineer-in-charge..
REF: SMDB-GF
REF: SMDB-FF with provision of 8nos 3phase KWHR meter
REF: SMDB-SF with provision of 8nos 3phase KWHR meter
REF: SMDB-3F with provision of 8nos 3phase KWHR meter
REF: SMDB-4F with provision of 8nos 3phase KWHR meter
REF: SMDB-5F with provision of 8nos 3phase KWHR meter
REF: SMDB-6F with provision of 8nos 3phase KWHR meter
REF: SMDB-7F with provision of 8nos 3phase KWHR meter
REF: SMDB-FF with provision of 4 nos 3phase KWHR meter
REF: SMDB-SF with provision of 4 nos 3phase KWHR meter
REF: SMDB-3F with provision of 4 nos 3phase KWHR meter
REF: SMDB-4F with provision of 4 nos 3phase KWHR meter
REF: SMDB-5F with provision of 4 nos 3phase KWHR meter
REF: SMDB-6F with provision of 4 nos 3phase KWHR meter
REF: SMDB-7F with provision of 4 nos 3phase KWHR meter
REF: SMDB-D1 with provision of 7 nos 3phase KWHR meter
REF: SMDB-RF
REF: DB-Common
REF: DB Floors
Supply and installation of isolators including enclosure all necessary fittings, fixing and supports complete, all in accordance with the Drawings and Specification. Complete in all respect and as per direction of Engineer In Charge.
20A - TPN - Isolator W/P
32A - TPN - Isolator W/P
40A - TPN - Isolator W/P
40A - TPN - Isolator W/P for electric car charger
63A - TPN - Isolator W/P for electric car charger (future)
Installation of Energy meters for individual flats including all necessary fittings, fixing and supports complete, all in accordance with the Drawings, Specification & authority regulations
Supply, Installation, testing & Commissioing of Water Level controller with level strobes for following tanks with wiring, conduiting, accessories, supports, etc. including interlocking with water pump motor starter controllers complete in all respect as per the manufacturer recommendations. Complete in all respect and as per direction of Engineer-in-charge..
For Overhead Tank
For Underground tank
Supply, Laying, termination, testing & commissioing of the following 1100 volts grade XLPE insulated sheathed Aluminium conductor armoured cable laid on ducts, cable tray or trunking including connection, terminations, fixings, fittings to equipment as required, complete; all in accordance with the Drawings and Specification
4C x 300 mm² + ECC. ( MDB TO SMDB )
4C x 185mm² + ECC (MDB TO SMDB)
4C x 95 mm² + ECC. ( MDB TO SMDB)
4C x 35 mm² + ECC. ( MDB TO SMDB )
4C x 25mm² + ECC. (MDB TO SMDB)
4C x 16mm² + ECC.
Supply, Laying, termination, testing & commissioing of the following 1100 volts grade FRLS insulated copper conductor flexible wire laid on ducts, cable tray or trunking including connection, terminations, fixings, fittings to equipment as required, complete; all in accordance with the Drawings and Specification. Complete in all respect and as per direction of Engineer In Charge.
4C x 25mm² + ECC. (SMDB TO DB)
4C x 16 mm² + ECC. ( SMDB TO DB'S )
4C x 10 mm² + ECC.( SMDB TO DB )
Supply, Laying, termination, testing & commissioing of the following 1100 volts grade PVC insulated copper conductor flexible wire laid on ducts, cable tray or trunking including connection, terminations, fixings, fittings to equipment as required, complete; all in accordance with the Drawings and Specification. Complete in all respect and as per direction of Engineer-in-charge...
2 x 1C x 1.5 mm² CU/PVC+1C x 1.5mm² ECC for Outdoor CCTV Cameras.
2 x 1C x 1.5 mm² CU/PVC+1C x 1.5mm² ECC for Fire Alarm Panel
2 x 1C x 1.5 mm² CU/PVC+1C x 1.5mm² ECC for Water Level controller.
2 x 1C x 1.5 mm² CU/PVC+1C x 1.5mm² ECC for SMATV head end equipments.
Supply and Installation of Heavy duty return flanged perforated GI Cable Tray / Compartmentalised GI Trunking of following sizes, complete with all factory made accessories, supports, earthing etc. as per specification. Complete in all respect and as per direction of Engineer-in-charge..
100x50mm Cable tray
150mm Cable tray
225mm Cable tray
300mm Cable tray
450mm Cable tray
150x 100 mm Cable Trunking
Providing and laying in position the following size of Double wall HDPE pipe confirming to IS14930 laid under ground between two manholes with 1.5mm Nylon draw wire, including earth work in excavation and backfilling, complete with jointing, accessories etc. required as per specification.
3 X 150mm Nominal Dia for main LV cables from Building plot edge to the Electrical room.
Providing and laying in position Masonary Manhole draw pit of following sizes for cables & Pipe ducts complete with heavy duty CI Manhole cover including earthwork n excavation, dressing complete with internal cement plaster as per the specifications. 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supply, fixing, testing & commissioing of following wiring accessories of approved make and design including modular switches, sockets, grid plate, front cover plate of finish as per architect, all necessary fittings, fixing and supports complete, all in accordance with the Drawings and Specification. Complete in all respect and as per direction of Engineer-in-charge..
5/6 amps switch
2 way 5/6 amps switch
3 pin 5/6 amp socket outlet for Exhaust fan
6A switched socket outlet for Tenant Fridge
6A switched socket outlet for Tenant RO water unit
6A switched socket outlet for Tenant Sink Waste Crusher
6A switched socket general outlets
16A switched socket general outlets
16 A switched socket outlet for Washing machine
16A switched socket outlets for Geyser
16A switch with neon for Geyser
16A switch for smart bath tum ( master bed toilet)
Bell push
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supply, fixing, testing & commissioing of following wiring for 230 volts single phase and neutral for following switch and socket outlet with FRLS insulated copper conductor 1100 volts grade stranded flexible wires in concealed / surface mounted 2 mm thick PVC conduit with 1.2 mm thick GI box with earthing stud complete all in accordance with the Drawings and Specification. Complete in all respect and as per direction of Engineer-in-charge..
Primary point for 16A + 6A switched socket with 2 x 4.0mm² wires + 1C x 2.5mm² ECC in Kitchen.
Same as item above but loop point with 2 x 1.5mm² wires + 1C x 1.5mm² ECC in Kitchen.
Primary point for 16A + 6A switched socket with 2 x 4.0mm² wires + 1C x 2.5mm² ECC in Living & Bedrooms.
Same as item above but for 6A switched socket loop point with 2 x 1.5mm² wires + 1C x 1.5mm² ECC in Living & bedrooms.
Primary point for 16A socket with 2 x 4.0mm² wires + 1C x 2.5mm² ECC for Geyser (Water Heater).
Same as item above but for 16A switch with 2 x 4.0mm² wires + 1C x 2.5mm² ECC for Geyser (Water Heater).
Primary point for 16A switched socket with 2 x 4.0mm² wires + 1C x 2.5mm² ECC for Washing Machine.
Primary point for 6A Twin switched socket with 2 x 1.5mm² wires + 1C x 1.5mm² ECC for Telephone Cabinet.
Primary point for 6A single socket with 2 x 1.5mm² wires + 1C x 1.5mm² ECC for Exhaust Fan.
Primary point for 6A single switched socket with 2 x 1.5mm² wires + 1C x 1.5mm² ECC for common area.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Receiving, handling, assemblying, installation, testing & commissioing of following Light fittings and fixtures with control gear, lamp, supports, fittings and all necessary accessories.
18/20W IP 42 surface mounted circular LED light for corridoors
15W LED surface mounted circulart - stairs
18/20W LED T5 tube fitting, IP-65 (parking)
10W LED recessed/surface mounted ceiling light toilets
10W LED mirror light with frosted diffuser, IP-40
LED surface mounted light (apart. corridoor)
10W LED recessed/surface mounted ceiling light
LED wall mounted light IP 20
Wall bracket light IP 65
Ceiling fans - 36" with regulator
Ceiling fans - 48" with regulator
Ceiling fans - 56" with regulator
35W LED T8 4FT tube fitting, IP-65 wall mounted
LED surface mounted light (apart. corridoor)
18W CFL Garbage Room Typ floor IP54
Wall bracket light IP 65
Supplying,installation,testing and commissioning of Microwave technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.6 mtr and for 5m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply.
Supply, fixing, testing & commissioing of wiring for 230 volts single phase and neutral for following switch and lights with FRLS insulated copper conductor 1100 volts grade stranded flexible wires in concealed / surface mounted 2 mm thick PVC conduit with 1.2 mm thick GI box with earthing stud complete all in accordance with the Drawings and Specification. Complete in all respect and as per direction of Engineer-in-charge..
Wiring for light point/ fan point/ exhaust fan point/ call bell/emergency light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC (secondary loop point) (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire)
Supply, install, testing of complete earthing system as specified and shown on drawings including earth electrode pits, earth continuity conductors, equipotential bonding, earthig cables , earth terminals for main distribution board, sub main distribution boards, final distribution boards, control panels, equipments, AC, cable tray and other appliances, etc. Complete in all respect and as per direction of Engineer-in-charge..
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/ coke and salt ) as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earth Terminal for wall mounting with provision for connecting multiple earth cables effectively.
50mm x 6mm GI AC earth Bar 600 mm long
50mm x 6mm GI DC earth insulated Bar 600 mm long
Bare GI tapes / wires including all necessary fixing accessories and effecting connections as per specifications.
25 X 6 mm thick GI tape.
6 SWG GI wire.
Providing, laying, testing and commissioning of following 1100 volts grade PVC insulated sheathed copper conductor unarmoured cable including copper thimbles, fixing hardware as required for Earth & Bonding of all panels & Equipments as per drawings confirming to Specifications.
Providing and fixing of test link in weather proof 1.6 mm thick MS box of approved make and design.
Supply, install, testing of complete Lightning Arrestor system & its associated earthing system as specified and shown on drawings including earth electrode pits, earth continuity conductors, equipotential bonding, earthig cables , earth terminals for Lightning Ssystem. Complete in all respect and as per direction of Engineer-in-charge..
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Supply and fixing of LED type aviation obstruction light complete Cat. No.752/ WIPRO make Cat. No.WAN 20001 or Bajaj make Cat. No.BJAOL-2 with 900mm long 32mm dia GI pipe.
Supply, Installation, Testing & Commisioning of following Manually operated electronic Fire alarm system (MOEFA) as detailed in the Specifications and on the Drawings and to the complete satisfaction and approval of the Engineer and all concerned Statutory Authorities and under the following sections. Complete in all respect and as per direction of Engineer-in-charge..
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
FRLS PVS insulated core 1.5 sq.mm Armoured copper cable on ceilling / wall using fixing accessories like screws, plug, clamps and etc.
6 watts wall mounted type Speaker
Supply and laying of 2 core 1.5 sqmm armoured copper cable for control wiring to the terrace pump motor with runs of 14 swg tc wire for earthing, providing in wall with suitable sized cable glands, copper sockets and etc.
Supply and laying of 2 core 1.5 sqmm armoured copper cable for control wiring to the terrace pump motor with runs of 14 swg tc wire for earthing, providing in wall with suitable sized cable glands, copper sockets and etc.
Supply & Installation of 1/3'' CMOS,1280x960:25fps(P)/30fps(N), 0.01lux/f1.2, 4mm/f1.8 lens, Electronic Day/Night Network Dome Camera
Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 16-Channel Video, 2 Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored atleast 30 days. With 2 CIF Resolution 25 FPS for 5 Cameras -6TB hard disk
Supply & Installation of 32" LCD TV
Supply & Installation of 8 Port Layer 2 manageble POE Network switch (16 PORT-10/100 BASE-T & 2 NOS. 1-G COMBO PORT FOR UPLINK)
Supply & Installation of CAT6, 8-Port loaded, Straight Jack Panel for Active data
Supply & Laying of CAT6 SL Series Patch cords Panel Side
Supply & Laying of CAT6 SL Series Patch cords Camera Side
Supply & Laying of Information outlet with 2 port 110 style faceplate
Supply & Laying of CAT6 UTP Cable with PVC conduit
Supply, Installation, Testing, Commisioning of Audio-Video Door Access Intercom Entry system with capacity of 3 Main entrance, 2 Conceierge (Guard) & 75 tenants Stations as detailed in the Specifications and on the Drawings and to the complete satisfaction and approval of the Engineer and confirming to manufacturer recommendation for the following. Complete in all respect and as per direction of Engineer-in-charge.
Main Entry Station : Wall mounted single gang master entrance station fully equipped with VFD displaying Unit name & number, scrolling message of 160 charaters, handfree Microphone, Speaker, 1/4" CCD"color camera (with night viewing), Access Control Direct Digital 20 Unique Codes Dailing Keypad, with in-built 220 VAC Power supply unit, complete in water resistant IP65 ABS plastic / Zinc cast tamper-proof enclosure operating at-10°C to 60°C.
Concierge / Guard / Reception Station : Desk top / Wall mounted Handset intrument with LCD screen for caller name & number, entrance door release button, two way communications with main entry station, direct dialing intercom facility with all tenant / other guard stations all in ABS plastic body.
Tenant / Apartment Station : Desk top / Wall mounted Handset intrument with LCD screen display for main station camera, entrance door release button, two way hands free communications with main entry station, direct dialing intercom facility with all tenant / guard stations all in ABS plastic body.
Door Controller : Door control unit complete with door interlocking and realsing, interfacing with Fire Alarm system for emrgency opening, Fail-safe feature complete with electromagnetic Door Lock, Door release Push Button, Emergency Door release Breakglass point.
Wiring : Solid non-shield PE insulated copper twin core twisted control wiring in conduit from door controller to each accessories including termination etc. complete in all respect as per specifcations & drawings and manufacturer recommendations.
Gate Barrier : Gate Barrier system complete with Pedestal, operating mechanism, power connection, warning light, Car Sensors, IR reader, operating keys, control panels etc complete in all respect as per drawings and specifications.
Gate Barrier with 3 meter long Boom
Remote IR Access keys for gate operation two key per flat
Providing and laying in position Masonary Manhole draw pit of following sizes for Telephone cables & Pipe ducts complete with heavy duty CI Manhole cover including earthwork n excavation, dressing complete with internal cement plaster as per the specifications. 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
600mm x 600mm & 600mm deep Telephone manhole
Providing and fixing of Distribution Cabinet / Frame in Telephone room suitable for multi pair copper conductor telephone cable termination complete as per local service provider standards & requirements for Fixed line service.
Main Distribution Frame (MDF) 100 pair
Intermediate Distribution Frame (IDF) 8 pair
Supply and installation of structured cables, laid in conduits, ducts, cable tray or trunking (measured elsewhere) including connection to equipments & terminations, as required, complete, all in accordance with the Drawings and Specifications.
10 pair copper conductor 0.5mm ² Jelly filled armoured indoor telephone cable from MDF to floor IDF at typical floors.
2 pair copper conductor 0.5mm ² HDPE Insulated, & PVC sheathed telephone indoor cable from IDF to Indoor Cabinet of each apartment / Quarter.
Supply, laying, testing & commissioing of following cabling complete with conduiting, Cable tray, GI Back box, terminations, labelling in all respect in compliance with local service provider for Fixed line and Internet as per drawings & specifications.
2 nos. 4 pairs Cat6A UTP cable/wire from Telephone ONT Cabinet to RJ11/RJ45 outlets inside apartment
Providing, fixing, testing & commissioing of Telephone system devices of approved make & design including modular Jacks, grid plate, front cover plate of finish as per architect, all necessary fittings, fixing and supports complete, fixtures, connections, terminations, fixings, fittings and the like complete; all in accordance with the Drawings,Specification, & Local regulations.
Dual Jacks 1xRJ 11 + 1xRJ45 Outlet (Voice + Data)
Apartment Telephone ONT Cabinet with Cat6A UTP Patch Panel, Copper Tag box confirming to BSNL, Twin Power socket, Space for Wireless Router, Space for (Future) FTTH box all in 60x60x15cm steel cabinet made from CRCA sheet having front glass door, recessed in wall complete to accept Future Fibre Connection, in future, all as per drawings & specifications.
IDF-A1 (to A7) for Fixed lines 20pair wall mounted with door lock facility inside Telephone cabinet at typical floor and confiming to BSNL standards.
MDF-A1 for Fixed lines 20 pair wall mounted with door lock facility inside Telephone room at ground floor and confiming to BSNL standards.
MDF-A1 for Fixed lines 100 pair wall mounted with door lock facility inside Telephone room at ground floor and confiming to BSNL standards.
MDF-A1 for Fixed lines 150 pair wall mounted with door lock facility inside Telephone room at ground floor and confiming to BSNL standards.
Supply and installation of perforated GI Cable Tray including fixings, fittings, supports, complete; all in accordance with the Drawings and Specification.
300x50mm Cable tray
Supply, install, test & commissioin SMATV devices and fixtures including supports, fittings and accessories; all in accordance with the Drawings and Specifications.Complete in all respect and as per direction of Engineer-in-charge..
SMATV coaxial modular socket outlet of approved make and design with modular grid plate, front cover plate of finish as per architect, all necessary fittings, fixing and supports complete, all in accordance with the Drawings and Specification
Coaxial 4 way IF Splitter with low return loss grade 3, high shielding, 75 Ohms, 5-2400Mhz, in high quality Die cast housing Sn coated, confirming to EN50083-2 & EN60728-4 indoor SMATV / TV Hub located inside at each apartment for SMATV service from floor cabinet floor.
Coaxial 8 way IF Splitter with low return loss grade 2, high shielding, 75 Ohms, 5-1000Mhz, in high quality Die cast housing Sn coated, confirming to EN50083-2 & EN60728-4 indoor SMATV / TV Hub located inside floor cabinet at each typical floor for SMATV service from roof floor.
100x50mm HDRF Cable tray from roof floor to the typical floor 8 way IF splitter.
150x50mm HDRF Cable tray from roof floor to the typical floor 8 way IF splitter.
Conduit and wiring to 'SMATV devices and fixtures points from distribution boards; including wires, conduits, connections, terminations, fixings, fittings and the like complete; all in accordance with the Drawings and Specification.
Coaxial RG11 cable from Roof top to floor Splitter
Coaxial RG11 cable from floor Splitter to apartment splitter
Coaxial RG11 cable from floor apartment splitter to TV point
Supply and installation of isolators including enclosure all necessary fittings, fixing and supports complete, all in accordance with the Drawings and Specification.
32A SPN Isolator W/P for AC machines
Supply, fixing, testing & commissioing of following wiring accessories of approved make and design including modular switches, sockets, grid plate, front cover plate of finish as per architect, all necessary fittings, fixing and supports complete, all in accordance with the Drawings and Specification.
25A Socket outlet connection for indoor AC
For indoor AC 30 amps. TPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure
Supply, fixing, testing & commissioing of following wiring for 230 volts single phase and neutral for following switch and socket outlet with FRLS insulated copper conductor 1100 volts grade stranded flexible wires in concealed / surface mounted 2 mm thick PVC conduit with 1.2 mm thick GI box with earthing stud complete all in accordance with the Drawings and Specification.
Primary point for 32A Isolator with 2 x 6.0mm² wires + 1C x 4mm² ECC for AC outdoor units.
Providing and fixing in position the following 2 mm PVC conduits concealed or exposed with 1.5mm Nylon draw rope including all accessories i.e bends, junction boxes with cover plates of approved make and design.
32mm dia for future Fiber cable from Telephone room at ground to Telephone ONT Cabinet inside each apartment.
Supply and installation of perforated GI Cable Tray including fixings, fittings, supports, complete; all in accordance with the Drawings and Specification.
100x50mm Cable tray
Allow for co-ordination with Local Authority for permanent power supply connections & release in all respect of Authority requirements
Supply, handling, laying, effecting proper connections, testing and commissioning of the following sizes of 1.1 KV XLPE insulated, Aluminium conductor, armoured cables laid in trenches over a bed of sand, excavation of trenches, covering with 1st class bricks, back filling adn compacting complete as required.as required, complete with end terminations glanding; all in accordance with the Drawings and Specification.
2 x 3½ Core, 400mm² cable From substation to Building B1
2 x 3½ Core, 400mm² cable From substation to Building B2
2 x 3½ Core, 400mm² cable From substation to Building B3
1 x 3½ Core, 400mm² cable From substation to Building C1
1 x 3½ Core, 400mm² cable From substation to Building C2
x 3½ Core, 185mm² cable From substation to Building D1
Providing and laying in position the following size of Hume pipes in road crossing and paved area, including earth work in excavation and backfilling, filling up joints with cement mortar 1:4 (1 cement : 4 coarse sand), laid on PCC 1:3:6 (1 cement:3 coarse sand 6 crushed stone aggregate 20 mm and down graded) and embedded in PCC 1:3:6, finished smooth, complete including sand cushioning at cable entry, etc. complete as required and as per specification.
300 mm dia. Hume Pipe
150 mm dia. Hume Pipe
Supply installation testing, and commissioning of external feeder pillar for street lights complete with all swichgears, busbar, protection, Timers, Solar Switch, all in weather proof free standing enclosure including the foundation cables connections, supports, or necessary excavation, backfilling, etc.
Feeder Pillar 6 Way TPN 100A
Supply & installation of Street lighting fixtures and accessories complete with brackets, luminaries, lamps, and cutouts, terminate cables, commission and grouting of base plate and handling down as shown in drawings including pole foundation, excavation, 1:3:6 Cement Concrete, 30 cm Cement Pedestal, pole painting 2 coat redoxide & 2 coat enamel, number painting, supports, fittings and accessories; all in accordance with the Drawings and Specifications and to the complete satisfaction and approval of the Engineer and all concerned. Statutory Authorities Proposed LED lighting fixtures shall have electrical & photometric specification to achieve all light parameters as per road class. Contractors shall submit lighting calculation using approved material for the approval of Engineer
Supply & installation of 9 meter high Steel Tubular Lighting pole with base plate, with 1 meter MS rod earthing & 1 meter overhang single arm including / for 1 x 150W LED street light with controlgears, batteries, internal wiring complete in all respect.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/ coke and salt ) as required.
Supply and fixing in position the following GI tape / wires including providing all fixing accessories and effecting proper connections.
6 SWG G.I. wire
25mm x 6 mm GI Tape
Supply, handling, laying, effecting proper connections, testing and commissioning of the following sizes of 1.1 KV XLPE insulated, Aluminium conductor, armoured cables laid in trenches over a bed of sand, excavation of trenches, covering with 1st class bricks, back filling adn compacting complete as required.as required, complete; all in accordance with the Drawings and Specification
1 x 4C x 16mm² cable from MDB B1 to Feeder Pillar
1 x 4C x 10mm² cable from Feeder Pillar to Street light & loop-in out
1 x 4C x 6mm² cable from Street light loop-in out
Wiring PVC insulated copper conductor wires of 1100 Volts grade inside steel tubular pole from control gear box to Street Light fitting & earthing with 1.5 sq. mm PVC insulated copper conductor earth wire including terminations all in accordance with the Drawings and Specification
3x1Cx1.5mm² wire
Supply, receiving, fixing of aviation obstruction light with LED low light with red colour LED intensity 30 candle in one direction, total intensity 600 (Type L1 - 300 Binay make)
Supply, Installation, Testing & commissioing of Containment system for Telephone cables by providing uPVC pipe ducts laid underground with Masonary Manhole Draw pits
Providing and laying in position the following size of Hume pipes in road crossing and paved area, including earth work in excavation and backfilling, filling up joints with cement mortar 1:4 (1 cement : 4 coarse sand), laid on PCC 1:3:6 (1 cement:3 coarse sand 6 crushed stone aggregate 20 mm and down graded) and embedded in PCC 1:3:6, finished smooth, complete including sand cushioning at cable entry, etc. complete as required and as per specification.
100mm Nominal Dia
Providing and laying in position Masonary Manhole complete with heavy duty CI Manhole cover including earthwork n excavation, dressing complete with internal cement plaster as per the specifications. 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
600mm x 600mm & 600mm deep Telephone manhole
Supply Installation, Testing & Commissioing of CCTV system devices and fixtures including hardware, head end equipments, wiring, connections, network switches, supports, fittings and accessories; complete in all respect as the Drawings and Specifications.
NPR camera : 1/3" CCD, PAL, Color C/CS Mount Box type IP Camera with 'Number Plate Recognistion (NPR)' suitable for outdoor location i.e., entry, exit and near boom barrier with POE, a resolution of 530 TVL, S/N ratio more than 50 dB having suitable sensitivity, day night digital signal processing, digital zoom, digital noise reduction and automatic gain control features, motion detection, OSD on screen display function, auto iris type vaerifocal lens with focal length of 3.6 mm to 10 mm, DC 12V / AC230 V operating voltage compatibility with outdoor housing suitable for camera and lens etc. complete as required with RS 232 / 485 port, VGA Card. Make : Bosch / Sony / Pelco / Samsung / Panasonic.
CCTV head end equipments with all accessories, warranties, operational manual, hardware & software supports, Jack & Connectors, lead wires, passwords, complete in all aspect for 24x7 operation of system as per drawings & specifications.
42" CCTV LED Monitor including all accessories.
Single mode OM3 Fiber Optics Outdoor cable in 50mm dia uPVC pipe underground including escavation & back filling for following buildings.
From Building B1 to Gate CCTV Monitoring station
From Building B2 to Gate CCTV Monitoring station
From Building B3 to Gate CCTV Monitoring station
From Building C1 to Gate CCTV Monitoring station
From Building C2 to Gate CCTV Monitoring station
From Building D1 to Gate CCTV Monitoring station
Network Video Recorder (NVR) with Keyboard, Joystick & 1 month storage
Network POE Switch
2 KVA UPS Single phase (230 V ± 15%) Volts input & single phase output (230 V ± 1%), 50 Hz. Input harmonic current THD 3% at 100% load, 6% maximum at 50% load with 15 minute battery backup along with battery cabinet complete in all respect as required.
Gate Barrier system complete with Boom barrier, Operating Pedestal, mechanism, manual operating lever, power connection, warning light, Car Sensors, IR reader, operating keys, control panels etc complete in all respect as per drawings and specifications.
Gate Barrier with 3 meter long Boom
Remote wired controller with open-close push buttons at Security gate
Remote IR Access keys for gate operation
unique infra engineers pvt ltd
DILLIP CONSTRUCTIONS PVT LTD
SRICO PROJECTS PVT LTD
M/s. PSK Engineering Construction & Co
M/s. PLCOMM INFRA LLP
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid