| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.3 LAccepted-AOC NO 43 AVINASHI ROAD GOLD WINS CIVIL AERODROME POST COIMBATORE 641 014 | COIMBATORE | TAMIL NADU | 641014 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹63.0 L+₹72,909 (1.17%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹63.3 L+₹1.0 L (1.67%)Rejected-AOC 2 209 1 NANGAVARAM ROAD PERUGAMANI POST SRIRANGAM TALUK TIRUCHIRAPPALLI | TIRUCHIRAPPALLI | TAMIL NADU | 620001 | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
17 Oct 2024, 3:00 pmClosed
SUPERINTENDING ENGINEER
THE SUPERINTENDING ENGINEER PWD BUILDINGS CONSTRUCTION AND MAINTENANCE CIRCLE COIMBATORE
PROVISION OF INTERNAL AND EXTERNAL ELECTRICAL ARRANGEMENTS TO THE ADDITIONAL BUILDING IN GOVERNMENT HOSPITAL AT JALLIPATTI IN TIRUPPUR DISTRICT.
2024_PWD_488764_1
07BCMCBE24092024
Open Tender
Electrical Works
Lump-sum
JALLIPATTI
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹42,000
29 Mar 2025
27 Sept 2024
17 Oct 2024
27 Sept 2024
17 Oct 2024
27 Sept 2024
Amount
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ).
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End.
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End.
Supply and fixing of single box type 4'20W LED fitting complete with TW round blocks on wall or ceiling with 20 W LED TubeLight (Double Side) with PVC unsheathed FRLS Copper leads from terminals to the fitting.
Supply and fixing of 9W LED Lamp for BH Point.
Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb.
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting.
Supply and fixing of 1200mm (48") Sweep BLDC ceiling fan complete (HIGHER END) with 2 Module 100 W Fan Step Regulator (HIGHER END) with stepped with 1 meter down rod on the existing fan clamp.
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall.
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan.
Supply and fixing of 16" (400 mm) Wall mounting fan on wall with necessary connection complete.
Supply and fixing of 16A Two -way switch in suitable Modular type GI box on wall with suitable front cover plate with connection(Higher End).
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End.
Supply and fixing of 3nos.6A two module 5 pin socket, 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug inflush with wall with earth connection (For AC Plug) (X-RAY, SCAN, ECG, LAB, DUTY DOCTOR, UPS IN & OUT)
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for
accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. i. 63A 4P MCB - 1 no. ii. 63A 4P 30MA RCCB/ELCB - 1 no. iii. 63A DP MCB Isolator -3 nos. iv. 6A to 32A SP MCB - 12 nos.
Supply and fixing of 63A FP MCB with 63A 30mA FP RCBO in flush with wall and making good of the concealed portion with earth Connection.
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion.
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.
Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.
Supply and Run of 4 of 16 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed portion.
Supply and run of 3 of 2.5 sq.mm PVC insulated SC unseathed FRLS copper conductor of 1100V grade in suitable gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour (For Lift).
Supply and fixing of 32A TPNMC switch on suitable angle iron frame work with MS cable entry box with earth connection only.
Supply and fixing of 63A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only-X-RAY
Supply and laying of 4x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 4 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamp.
Supply and fixing of brass cable gland for 4 x 10sq.mm. PVC armoured LTUG cable with earth connection.
Supply and laying of 3 1/2 x 25 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
supply and laying of 3 1/2 X 25 sq.mm PVC armoured LTUG cable in suitable size GI pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clamping of 3 1/2 X 25sq.mm. PVC LTUG armoured cable on post or on wall with MS clamp.
Supply and fixing of brass cable gland for 3 1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply, Fabrication, Erection, Testing and commissioning of indoor dust and vermin proof four compartment CT Metering panel made up of 16SWG CRCA sheet of size 48" x 48" x 18" with necessary stiffner and provided with following arrangements. 1. Front open door for each compartment provided with sealed locking arrangement. 2. 6mm thick hylam sheet in metering compartment for fixing 3phase 415V 4wire 50Hz Digital Energy meter provided by TANGEDCO.
3. 3Nos 1.5" x 1/4" and 1" x 1/4" Copper bus bar on suitable bus support with 3Nos 315/5A CTs in bus bar compartment. 4. 3Nos 315A fuse unit & 1no 250A neutral link on 6mm thick hylam sheet in fuse comparment. 5. Fixing of control fuses and wiring with flexible PVC copper wire and LED Indicator arrangements. 6. 2Nos copper earth bus of 1" x 1/8" in the rear side. 7. Suitable MS base channel for mounting. 8. Viewing glass in the door for meter compartment. 9. Provision of cable entry and outgoing compartment. 10. Painting the panel with 2 coats of epoxy paint over one coat of red oxide.
Supply, Erection, Testing & Commissioning of 250A capacity Dust & Vermin proof cubicle panel made out of 16SWG CRCA sheet steel enclosure with supply & fixing of the following interior mounting fuse switches with HRC fuses with a central bus bars chamber & two numbers of Horizontal cable chamber at top and bottom. 250A FP SDF Double Break switch withHRC fuse units - 1no as incoming.
Outgoings: 125A TP SDF Double Break switch with HRC Fuse units - 2Nos. 63A TP SDF Double Break switch with HRC Fuse units - 8Nos.
The bus bar chamber consist of 4nos. of 30mmx6mm Copper flat for three phases and neutral and also for interconnection for 250A switch. The interconnection with the bus bars to the 125A SDF DB Switches with 30mmx3mm Copper flat, 63A SDF DB Switches with No.8 SWG Copper Conductor and Double earth connection to all the switches should be done using No.8 SWG Copper conductor. The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.
The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition 2 runs of 1"x¼" copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit. The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches.
The Panel should be mounted on angle iron frame work of size 1½"x1½"x¼" MS channel provided all around the sides of the panel. The whole arrangements should be erected on 3"x1½"x¼" MS Base channel on a suitable masonry pedastal. (All Switches should be with ISI mark and of Higher End make only).
Supply and laying of 3 1/2 x 240 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 3 1/2 X 240 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3 1/2 x 240 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3 1/2 x 240 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Supply erection testing commissioning of 2.0TR (6000 KCal/ Hr) ABS Plastic split type Air Conditioner (3star) conforming to IS1391 [Part-2] 1992 with Rotary compressor operating on Non CFC refrigerant suitable for wall mounting for operating on 230V 50HZ single phase AC supply with Three Star rating Model as per BEE Specification and capable of performing the following functions. A)Cooling B)Dehumidifying C)Air circulating D)Filtering. the installation work for the above split type AC units includes the following.
1. Mounting / fixing indoor and outdoor units at their respective locations. 2. Laying refrigerant pipe line of 6mtrs. distance, both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polythene foam 5mm thick tubing. 4. Laying 15mm dia flexible PVC drain pipe of 6mts. Length to throw out the condensate water being formed in the indoor unit.
5. Leakage testing the entire gas unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit.
Supply and Erection of 5 KVA Voltage stabilzer for 2 TR split type AC unit high / low voltage cut off time delay relay with input voltage cut off time range of 170V - 270V and out put range of 200 - 240V with 3 minutes time delay relay.
Supply and fixing of MS stand for fixing outdoor unit.
Supply and fixing of 5000VA UPS with 8Nos.12V 150AH tubular battery [Exide IT 500] with 2 hours back up and 48months warranty for mentioned capacity on full load operation and the following features.
a) Inverter shall be free from workman ship defects sharp edges nicks, scratches, burs etc, all fasteners shall be fixed properly. Equipments shall be complete with all parts and all parts shall be functional. b) Enclosure shall conform to protection requirement of IRL to IS 13947 (part 1) 1993.
c) Switching device shall be MOSFET (or) IGBT. d) Switching frequency shall be about 50HZ. II. Input ; 120 v to 260 v 50 HZ single phase AC III. Output : The variation in output voltage from No load to full load expressed as a percentages of no load voltage shall not exceed +1.5% over + 10% and 20% variation of the rated DC input voltage. The frequency of the output voltage shall be 50 HZ + 1.3%. IV). Inverter efficiency minimum 85% as per CI.T.93 of ISS.
v) Over load: inverter shall with stand 10% overload for at least 10 minutes. V). Protections. VI). a) When the Input voltage goes outside the range 120 to 260 volts the system shall switch over to inverter mode. b). over voltage short circuit and over load protection at inverter output terminals. C).Battery reverses polarity. d). Protection against over discharge. The load shall be cut off as soon as the voltage of the battery terminal falls blow. i) 10.5 v for 12 v and ii) 21v for 24v battery system e).The inverter shall incorporate an arrangement for automatic change over of load from main supply to the inverter AC output incase of failure of mains supply with correct pending indication as per cL; 5.6 of IS 13314/ 1992 f). inverter should have surge protection also VII indicators. a) Following indicators shall be provided.
i) Mains presence ii) Mains mode. iii) Battery charging iv) INVERTER MODE v) Battery low. 8. battery bank; 12 Volts lead acid battery to IS 7372 (1995) with amdts.No1,2&3 shall be reputed makes with ISI mark. 9) Battery stand with wheel angle iron frame arranged.
Design, Engineering, Supply, Fabrication, Erection, Testing, Commissioning and Handing over of 1No.20 persons 1360kg Capacity Passenger cum Bed Lift (Gearless) with Machine Room and Disable friendly and with fire rated doors as per the following specifications. 1. Location : Additional Building in Government Hospital at Jallipatti 2. No. of Lift : One No
3. Type of Lift : Passenger cum Bed Lift with machine room - Gearless model 4. Capacity of Lift : 20 Persons / 1360kgs 5. Speed : 1.0mtr / sec 6. Type of Drive : V3F Drive with enhanced ride comfort and near Zero Level Functions. 7. No. of Floors : 2 Floors [Ground + 1] 8. Total Travel : 3.6Mtrs / Pit 1600mm / Head room 4800mm 9. Leveling accuracy : High level accuracy with smooth and jerk free stopping.
10 Construction of lift shaft : RCC with brick masonry 11.Car: 18 SWG High Quality Car. S.S. Car and Hand rail, granite /marble flooring and Perspex False Ceiling. 12 Position of Machinery : Directly above the Lift well – Gearless. 13 No. of Landings : 2 in the front side only. 14 No. of Car Entrance : One in the front side. 15 Car Entrance : Power operated V3F Drive, Side opening Sliding Stainless Steel (1.5mm) Hairline finish door.
16 Landing Entrance door : Side opening Sliding Stainless Steel (1.5mm) hairline finish door with provision for Emergency Exit key at all landings. 17 Lift well : 2300mm (Wide) x 3000mm (Depth) available as per Chief Architect Drawing. 18 Lift Pit : 1600mm Depth. 19 Car Size : 1300 x 2400 x 2200 (mm Wide x mm Depth x mm Height as per IS 14665 (Part I) 2000 20 Car Clear Opening of Gates / Doors / Lintel : 1200mm Wide x 2000mm Height and Lintel : 2200mm as per IS 14665 (Part I) 2000
26 Emergency provisions : Battery operated Alarm bell & Light to be Provided with Automatic charging device. 27 Fire Man’s switch : In the Ground Floor 28 Minor Builder works : included 29 Scaffoldings : included 30 Sill angles and Fascia Plates : included 31 Steel for Lift Machinery : included 32 Servicing and maintenance : Free Comprehensive servicing and maintenance for one Year Guarantee period.
33 Automatic Rescue Device : Provision to facilitate the landing to the nearest floor at the time of power failure. The ARD consists of suitable Battery system with charger, Inverter, under voltage protection system etc. complete with all accessories. 34 Provision for Intercom : To be provided in the Lift Car, Ground Floor Reception Area & Machine Room with Phone (Press & Speak) with clear and Audible volume of sound.
35 Lift License : Preparation of Drawings, payment of inspection charges to CEIG and insurance policy and Obtaining CEIG approval for the Lift as per Lift act should be done by the Lift contractor. 36 Floor Position : Included with LED display and floor annunciator. 37 Special Features: a. Infra red door sensor with full height screen b. Full width half height rear panel mirror c. S.S. hairline finish hand rail in car d. Stainless steel signal features e. Vandal proof SS button with SS cover f. S.S. hairline finish door frames for landing doors g. V3F door operator h. Call register signal
i. Stainless steel facio plates for car operating Panel and landing fixtures j. Steel ladder in Lift machine room and in lift pit. k. On / Off switch for fan and light l. Over-load warning indicator with audio Announcer m. Voltage stabilizer for control circuit. n. Small Vision Glass of size not less than 150mm x 500mm in both of the two centre opening doors of Lift Car as well as Landing doors. o. Differently abled persons friendly. 38 Over Speed Governor, Phase failure and Phase reversal Relay, alarm bell, T guide brackets for car and counter weight, Rubber padding under the winding unit, Motor of adequate capacity,
Electromagnetic brake with compression springs, Car safety gears, Buffers, Electro mechanical locks, Emergency key, side supporting angles, Motor over load protection devices, Final limit switch main, suspension ropes, Counter weights, Lifting joist for mounting the Machineries. 39 Guarantee : Guarantee for at least one year for the materials and workmanship of equipments should be offered by the Lift contractor.
40 Site testing in accordance with IS 14665 should be carried out at the time of Handing over to the User department. 41 Supply, operation and maintenance manual and necessary tools for operation and a set of spare parts required for one year to be provided. (KONE/JOHNSON/OTIS/EQUIVALENT)
SUN ELECTRICALS (BID ID -1165564)
GANAPATHY ELECTRICALS (BID ID -1166845)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .