| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr Quoted ₹1.7 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹1.8 Cr+₹9.7 L (5.76%)Rejected-Finance | ₹1.8 Cr+₹9.7 L (5.76%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹1.8 Cr+₹15.0 L (8.93%)Rejected-Finance | ₹1.8 Cr+₹15.0 L (8.93%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹1.9 Cr+₹19.9 L (11.8%)Rejected-Finance | ₹1.9 Cr+₹19.9 L (11.8%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹1.9 Cr+₹20.7 L (12.3%)Rejected-Finance | ₹1.9 Cr+₹20.7 L (12.3%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹2.0 Cr
EMD Value
₹2.7 L
Closing Date
27 Jun 2022, 6:00 pmClosed
Chief Engineer Bathinda, Bathinda Mil Stn
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
ADDN/ ALTERATION OF 12 X OFFICER MARRIED ACCN AT ABOHAR MIL STN
2022_MES_521378_1
CE BTZ/ABH/TOKEN-04 OF 2022-23
Open Tender
Civil Works
Item Rate
458 days
Abohar Mil Stn
As per NIT
9 documents required · 9 mandatory
₹1,000
GE Abohar
₹2.7 L
Yes
21 Jul 2022
2 May 2022
29 Jun 2022
2 May 2022
27 Jun 2022
13 Jun 2022
Amount
B/R PORTION
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, bed block & similar work etc including form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement including 10mm wide, 30mm deep joints at the rate of 2.5 mtr centre to centre and at every turning point, filling the Joints with bitumen 7 sand mixture complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 4mm dia galvanised iron wire fitted with nut bolts complete all as specified & directed by Engineer-in- charge.
Demolition of cement concrete reinforced of any description (roof, beams, staircase, landing, chajjas etc) and in any position not otherwise specifically provided, including reinforcement cut as required to facilitate demolition and prepare the surface to casting/jointing new including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, cills, steps; seismic and other similar bands complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to better rough finished flat complete all as specified & directed by Engineer-in- charge.
Form work to sides of pillars, posts, struts piers, columns and stanchions and similar works (Square, rectangular or polygonal) rough finished complete all as specified & directed by Engineer-in- charge.
Form work to flat sides and soffits of floor or roof beams, beam haunchings, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams, etc. and similar works rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed by Engineer-in- charge.
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide, rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
Dismantling of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work (old serviceable bricks obtained from dismantled item shall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with Fly Ash bricks (old size ), straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work in half brick thick wall using Fly Ash bricks (old size bricks) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in- charge.
Material and labour for 40mm thick precast cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in louvers and jallies (measured solid) including all moulding but excluding frame and set in cement mortar (1:4) including necessary form work complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for internal plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- WPC shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 10mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster (1:1/2:2) (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete as specified and as directed by Engineer-in-Charge. Note :- Grooves shall be measured & paid separately
Material and labour for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as specified and as directed by Engineer-in-Charge.
Material and labour for damp proof coating system with single component ready on Rising damp area, Preparaing the surface thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings etc. all large voids or hollow portions must be removed and replastered. Non-moving cracks having width upto 5 mm must be filled with polymer based crack filler, after prepared the surface applying the first coat of Hydamp with paint brush directly on the prepared surfaces. Allow to dry for a minimum 2-3 hrs. Apply one part of Roff Hydamp and 2 parts of OPC white cement and make the putty, apply putty on the entire surface area. Allow it to dry for atleast 3-4 hours.Apply the final coat of Roff Hydamp on the entire surface complete all as specified and as directed by the Engineer-in-Charge.
Shotcreting average thickness 25mm in RCC columns, beams and slab etc. (with mix minimum cement content of 350 Kg per Cum). Concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregates of 6mm maximum size in proportion as per design criteria) incl the cost of centering and shuttering at edges and corner etc as directed by Engr-in-Charge incl chipping of unsound/week concrete material 50mm average thickness from slabs, beams/columns etc with mannual chiesels or standard power driven per cussion type or of approved make incl tapping of all edges, make square shoulder of cavities incl cleaning the exposed concrete surface and reinforcement with wire brushes and throughly washing with water and allowing it to dry etc incl removel of rust by applying approved rust removed chemical and the coating with Dr Fixit Epoxy zinc primer @ 6 Sqm per Litre at DFT of 100 micron as per specification, applying the SBR Latex based bonding agent on each layer of the shootcreting work of Dr Fixit Pidicrete URP on the entire surface complete all as directed including 5mm thick cement plaster in CM(1:3) finished even and smooth without using extra cement including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete as specified and as directed by Engineer-in-Charge. Make :- Sika / Fosroc
Providing and injecting approved grout in proportion Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used modified cement slurry non shrinks compound in concrete/RCC work. Made with recommended by the manufacture into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of GE. Note :- The payment shall be made on the basis of actual weight of approved grout injected.
Supply and fixing Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia and rawl plugs fixed in reinforcement complete all as specified and as directed.
Cutting holes into or through brick walls built, in cement mortar and making good in cement mortar (1:3) or cement concrete (1:2:4) type B-0 as required (Superficial area not exceeding 150 Sqcm) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and removing from site complete all as specified and as directed by Engineer-in- charge.
Taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and refixing in same opening after necessary easing, adjustments, minor repairs, oiling, adjustment with cutting or fixing plain fillets/planks made from second class hard wood etc to remove gap between floor and shutter complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made pressed steel frames of size 125 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , including fixing only butt hinges suitable Nos as directed for each leaf, and making good the wall with plaster in CM 1:6 complete all as specified and as directed by Engineer-in- charge. Note : - Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply and fixing factory made pressed steel frames of size 105 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , including fixing only butt hinges suitable Nos as directed for each leaf, and making good the wall with plaster in CM 1:6 complete all as specified and as directed by Engineer-in- charge. Note : - Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Material and labour for PCC (1:3:6) type C-1, using 20 mm graded aggregated as in back filling of pressed steel door frame/chowkhat and bed block for fixing of hold fast complete all as specified and as directed by Engineer-in-Charge
Supply & fixing factory made plain framed panelled shutter 35mm thick made out of 2nd class hard wood with lock rail and panel (two panels) inserts of 9mm BWP commercial ply. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in- charge.
Supply & fixing factory made glazed and skeleton shutter 35mm thick made out of 2nd class hard wood kiln seasoned and chemically pressure treated, open rebated and prepared to receive glass, gauze, etc., but divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, any numbers, fitted with cut and mitred beads for securing glass, gauze etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Fiber Glass Reinforced plastic (FRP) Door Frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate door frame moulded with two resistant grade unsaturated polyester plain and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete all as specified and as directed by Engineer-in- charge.
Supply and fixing to existing door frames 30mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
Material and labour for providing kitchen cabinet and cubboard in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet (for shutter, back side of cabinet, sides of cabinet, partition and shelves etc). All the edges of shutter and front exposed edge of partition/shelves shall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-charge. Note :- (i) The area of each sheet (shutter, back side of cabinet, sides of cabinet, partition and shelves) shall be measured in sqm for payment. (ii) Magnetic catcher, handles, continuous Piano hinges and PVC frame (where required) shall be measured and paid separately under appropriate item of BOQ. (iii) Any other material required for making/fixing/hanging of cabinet shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Supply and fixing Magnetic catcher fixed with steel screw complete all as specified and as directed by Engineer-in-charge.
Supply and fixing extruded brass handle fabricated type 100mm long for cabinet shutter fixed with steel screw complete all as specified and as directed by Engineer-in-charge.
Supply & fixing Continuous (piano) hinges, stainless steel, bright finish, width of flap when open 30mm complete all as specified and as directed by Engineer-in-charge .
Supply and fixing Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as directed by Engineer-in-Charge. (Note :- Frame shall be elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
Supply and fixing mild steel butt hinges, medium weight 100 mm size fixed with steel screw complete all as specified and as directed by Engineer-in-charge.
Supply only 100mm long stainless steel butt hinges heavy duty type B-21 including screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing aluminium tower bolt 150 mm size fixed with steel screw complete all as specified and as directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified and as directed by Engineer-in-charge.
Supply and fixing aluminium door handle D type 150 mm size fixed with steel screw complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified and as directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 125mm long aluminum anodised hasp & staple, safety type, with hinge pin including bolt to hinge plate fixed with and including screws complete all as specified and directed by Engineer-in-charge.
Supply & fixing Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, Overall length of cover plate 150mm, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, 2nd class hard wood (Sal) or any other 2nd class hard wood articles not exceeding 200 cubic centimetre each as small fittings such as shaped door and window stops and the like, including necessary labour etc all as specified & directed by Engineer-in- charge
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to frame with screw complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Stainless steel solid body fancy type peg set of six and fixed in position with steel screws complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing aluminium anodised frame, made out of aluminium section powder coated (minimum thickness of powder coating not less than 50 micron) for doors, window, ventilators and aluminium partition with one or more rebates including joining cleat for fixing etc., the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners. Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and as directed by Engineer-in-Charge. Note :- The weight of each section shall be physically ascertained through a board of officers convened by GE and payment shall be made only after the actual weight at site.
Supply & fixing anodised aluminium window shutter and ventilator shutter side hung type without sash, made out of aluminium section weighing not less than 0.55 Kg/mtr (1.50 to 1.80 mm thk), powder coated (minimum thickness of powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings (each shutter) such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 Nos) suitable handle (1 No.), and nesecarry assecories as required complete all as specified and as directed by Engineer-in-Charge. Note :- Aluminium chowkhat frame and Glass shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing aluminium sliding window three track with frame & two glass shutters using 4 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61 mm using aluminium powder coated section (minimum thickness of powder coating not less than 50 micron) including approved fittings like aluminium cleat, PVC track, bearing, handle lock, rubber beading etc complete all as specified and as directed by Engineer-in-Charge. Note:- Size of aluminium section of make Jindal main-2010 or equivalent in make mentioned in Appx A to PSS-II (Equivalency approved by GE) shall be as under :- (i) Three track top and vertical - Section No 20621. (ii) Three track bottom - Section No 20620 (iii) Shutter vertical section - Section 20604 (iv) Shutter top and bottom - Section 20604 (v) Shutter vertical middle (interlock) - Section 20605 (vi) Cost of Glass and wire cloth shall be included in the unit rate.
Supply & fixing aluminium Powder coated grill weight not less than 1.50 kg/sqm in windows, doors or ventilators including fixing material complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing 4mm thick sheet glass ordinary quality in squares / retangular not exceeding 0.5sqm in each pane (aluminium window/ventilator) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing, 4mm thick figured glass pin head type in squares / retangular not exceeding 0.5sqm in each pane (aluminium window/ventilator) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack or stainless steel wire staples complete all as specified and as directed by Engineer-in- charge
Supply & fixing in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack or stainless steel wire staples complete all as specified & directed by Engineer-in- charge
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed by Engineer-in- charge.
Material and labour for mild steel Framed work such as grills, ladder, cooler stand, cloth drying provision, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Mild steel bolts exceeding 12mm dia and not exceeding 20mm dia of neck, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde-E- 250) quality-A complete all as specified and as directed by Engineer-in- charge.
Material and labour for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by Engineer-in-charge.
Material and labour for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre 300mm apart including drilling depth of holes not less than 300mm and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by Engineer-in-charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles light shade 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed bed) in cement mortar (1:6) and finish the surface rough to receive the tile complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles light shade 7 to 8mm thick square or rectangular (same as floor tile ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (rendering) in cement mortar (1:3) and finish the surface rough to receive the tile including making good plaster surfaces (above skirting tile) to match the existing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for double charged vitrified ceramic coloured tiles (light shade) 10 mm thick square or rectangular area of each tile not exceeding 0.36 sqm, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed bed) in cement mortar (1:6) and finish the surface rough to receive the tile complete all as specified and directed by Engineer-in-Charge.
Material and labour for double charged vitrified ceramic coloured tiles (light shade) 10mm thick square or rectangular (same as floor tile, as per above item ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (rendering) in cement mortar (1:3) and finish the surface rough to receive the tile including making good plaster surfaces (above skirting tile) to match the existing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles light shade of size 300mmx 450mm, 7mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (rendering) in cement mortar (1:4) and finish the surface rough to receive the tile complete all as specified and as directed by Engineer-in-Charge.
Dismantling of Stone slabs of any description or thickness in floors, plateform, apron etc laid bedded and pointed in any mortar including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour 18-20mm thick machine cut, granite work duly factory grinding and polished (table rubbed and polished) as in steps, jambs, pillars, window-cills, cooking platforms (minimum size equal to width of slab, not less than 610mm) and like laid over and including 20 mm thick bedding layer in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 20 to 25 mm thick, Kota stone slab (size of slab not less than 550x450mm for flooring and in single piece for treads/riser of staircase), laid over and including 20 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 18mm thick, Kota stone slab as in skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 25mm thick cement concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in sub base of floor for leveling course, surface finished rough complete all as specified and as directed by Engineer-in-charge.
Material and labour for water proofing treatment to sunken slab and adjoining vertical surfaces as per any of the following method complete all as directed by Engineer-in-charge/GE. :- Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 300mm on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.
(B) Bore Packing : All the borehole gaps between concrete surface and pvc pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout or approved equivalent having dual shrinkage compensation property. Before the bore packing, surface of the pvc pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement.
Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing roof surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k or equivalent. After removal of all lose materials like dust etc. with wire brush coir brushes from roof surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based repair mortar/micro concrete, after the repairing work making the gola on surrounding wall’s junction and seal the vertical walls up to 300mm. In case of core cutting on the surface, the joint is seal with non-shrink grout. (B) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment.
Note : (i) Work shall be executed through specialized agency (ii) The treatment shall be carried out as per the manufactures instructions and as directed by the Engineer in charge. The name of firm shall be got approved from CWE before carrying out the work. (ii) The Plan area of floor shall be considered for payment. (iii) PCC filling under sunken area will be measured & paid separately. Make : Method 1 (Asian paint)/ Method 2 (Dr fixit) or Techno commercial equivalent in Fosroc/Sika/STP
Material & Labour for 40 mm GI pipe medium grade, made to shape as in spout pipe 60cm long in sunken/ verandah/ Balcony including making hole and making good with cement mortar complete all as specified and as directed by Engineer-in-charge.
Material & Labour for PCC (1:5:10) type E2 using 40mm graded stone aggregate as filling of sunken floors complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall, ceiling, floor etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall, ceiling, floor etc. complete all as specified and as directed by Engineer-in-charge.
Re-fixing old serviceable 15mm bore galvanised steel water tubing (GI pipe) including all fittings in new or old portion/position to walls, ceiling, floor etc complete all as specified and as directed by Engineer-in-charge. (Note :- Old serviceable pipe and fittings obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally and rerunning the old screw threads as required.
Re-fixing old serviceable 20mm bore galvanised steel water tubing (GI pipe) including all fittings in new or old portion/position to walls, ceiling, floor etc complete all as specified and as directed by Engineer-in-charge. (Note :- Old serviceable pipe and fittings obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally and rerunning the old screw threads as required.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection including dismantling/taking down of existing unserviceable PVC water storage tanks of any description and capicity complete all as specified and as directed by Engineer-in-charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection including dismantling/taking down of existing unserviceable PVC water storage tanks of any description and capicity complete all as specified and as directed by Engineer-in-charge.
Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply and fixing gun metal, globe or gate valve (ISI marked), with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply and fixing in replacement bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head or round head/knob, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Cat part No CON-CHR-107KN of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing in replacement pillar tap cast copper alloy with capstan head, chromium plated, fancy type, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Make :- Cat part No CON-CHR-021KN of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing in replacement central hole basin mixer valve with regular spout, 15mm bore, brass chromium plated, for mixing hot & cold water, complete with fittings, 450mm long braided hoses with connection and nut for WHB complete all as specified and as directed by Engineer-in-charge. Cat part No CON-CHR-167KNB of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing in replacement mixer valve 15mm bore, brass chromium plated, for mixing hot & cold water with provision for overhead shower with 140mm long bend pipe, screwed down for iron pipe suitable for fixing to wall, complete all as specified and as directed by Engineer-in-charge. Cat part No CON-CHR-273KNUPR of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing in replacement mixer valve with swinging spout (for sink) 15mm bore, brass chromium plated, for mixing hot & cold water, screwed down for iron pipe suitable for fixing to wall complete all as specified and as directed by Engineer-in-charge. Cat part No CON-CHR-309KNM of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing in replacement 15 mm bore chromium plated Angle stop valve of cast copper alloy chromium plated, fancy type screwed down high pressure with on/off handle screwed end for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-charge. Cat part No CON-CHR-059KN of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply & fixing in replacement cromium plated swivel shower of any colour with shower arm 15 mm size,195 mm long with bend of 45 degree with flange of any colour for fixing with 15mm dia pipe complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight 40+40gms.
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and fixing in replacement Kitchen Rack / Dish Rack (Kitchen Stand or wall mounted) of size 750mmx600mm (Appx size) made out of Food Grade Stainless Steel 1mm thick sheet including necessary arrangements for plates and utencils to keep (Holds up to many plates or bowls To accommodate several place settings, Multipurpose), stylish modern streamline design, rust resistant, easy to assemble and clean including fitting accessories complete all as directed by Engineer-in-charge.
Supply & fixing in replacement stainless steel sink with drainage board made out of 1.00mm thick sheet , kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar to dwarf wall or fixing cast iron cantilever brackets and connecting union to waste pipe; overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stainless steel curtain rod 25mm dia, wall thickness of pipe not less than 16 guage and grade SS 304, including brackets and pair of decorated end knobs (finials), stop roller etc. as per site requirement, fixed to wall with fixing accessories, including taking down old existing curtain rods any type or condition complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement vitreous china wash basin, white, flat back of size 550mm x 400mm with full pedestal, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting with long screwed shanks & fly-nuts, flange end bedded in red lead cement complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting with long screwed shanks & fly-nuts, flange end bedded in red lead cement complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm white with integral foot rests, excluding flushing cistern, flush pipe above floor but including PVC (SWR) 'P' trap 100/110mm bore and including setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing upto entire satisfaction of Engineer-in-charge before filling concrete complete all as specified and as directed by Engineer-in- charge.
Supply and fixing hand shower (health faucet) ABS body including 1 meter long 8mm dia flexible tube and including wall hook complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No F8030103 of CERA or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing in replacement PVC low level cistern of 10 ltrs capacity with top push button inclusive of brackets and PVC bend long type and connection to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC Bathroom mirror cabinet of appx size 450mm X 350mm X 140mm (Compact Mirror Cabinet, Concealed shelves) approved quality complete all as specified and as directed by Engineer-in-charge.
Supply and fixing chromium plated Towel Rail (Single) 600/610mm long between flanges including bracket, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Cat part No ACN-CHR-1111SM of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing chromium plated Towel Ring Round, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Cat part No F5007105 of CERA or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing chromium plated Toilet paper/Roll Holder with Stainless Steel Flap, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Cat part No AC-705 of ESS ESS or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing corner Glass shelf including chromium plated bracket and guard railing fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Cat part No ACN-1173 of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
Supply and fixing chromium plated soap dish holder, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Cat part No F5007106 of CERA or Techno commercial equivalent in make mentioned in Appx 'B'
Taking down eaves gutters and rain water PVC pipes ( any size or pattern) including all fittings, heads, shoes, bends, swan-neck etc ( measured overall as fixed along the centre line over fittings and accessories) complete as specified and as directed by Engineer-in- charge
Dismantling/taking up or down CI soil waste and vent pipe 100mm dia of any description from wall and taking out from trenches including all fittings (bend, trap, cowl, branch piece etc) and removing from the site complete all as directed by Engr-in-Charge.
Dismantling/taking up or down CI soil waste and vent pipe 75mm dia of any description from wall and taking out from trenches including all fittings (bend, trap, cowl, branch piece etc) and removing from the site complete all as directed by Engr-in-Charge.
Supply & fixing 75mm bore PVC (SWR) pipes single socketed (pressure rating not less than 6kg/sqcm) in any length with rubber ring joints for drain or rain water fixed along walls with and including PVC stack clamps (interval of 1m) of suitable size, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed (pressure rating not less than 6kg/sqcm) in any length with rubber ring joints for drain or rain water fixed along walls with and including PVC stack clamps (interval of 1m) of suitable size, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water laid in trenches /under floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water laid in trenches /under floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) junction single, (Single T) equal or unequal with access door suitable for 75mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) junction single, (Single T) equal or unequal with access door suitable for 110mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) junction double, (double T) equal or unequal with access door suitable for 75mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) with access door suitable for 75mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) with access door suitable for 110mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) multi floor trap with grating including jointing with solvent cement suitable for 75mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Grating doom 125 mm dia with waste hole of stainless steel complete all as specified and as directed by Engineer-in- charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour with using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new plastered Internal wall surface by sand papering or by any other mean and after preparing the surfaces applying the following complete all as specified and as directed by Engineer-in-charge:- (a) Applying Wall care putty in two coats (1mm thick each coat) on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directed. (b) Two coats of acrylic distemper of approved tint over a coat of primer by using Airless spray / Roller.
Material and labour for preparation of new plastered surfaces of ceiling by sand papering or by any other means, preparing the surfaces smooth and after preparing the surfaces applying three coats of lime white wash with using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment on Old Internal wall surfaces of any desciption, preperation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology and after preparing the surfaces applying the following complete all as specified and as directed by Engineer-in-charge:- (a) Applying Wall care putty in two coats (1mm thick each coat) on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directed. (b) Two coats of acrylic distemper of approved tint over a coat of primer on old prepared surface by using Airless spray / Roller Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible.
Material and labour for Preparation of old decorated surfaces (plastered/unplastered) of walls/pillars /cornices by remove / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean and washing down with water including applying wall care putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth, and after preparing the surface smooth applying one coat of cement base paint with paint brush as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of old decorated surfaces (plastered / unplastered) of ceiling by remove / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean including applying wall care putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth, and after preparing the surface smooth applying One coat of lime white wash with paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in- charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in- charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Demolition PCC/chequered tiles laid flat of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping, as in kerb or mud stops, rounded or chamfered on edges, packing around chequered tiles, sides/around of interlocking tiles, bed block, for embedded posts & similar work etc complete all as specified and as directed by Engineer-in-charge.
Supply & fixing chequered cement concrete coloured tiles (with grey cement & pigment) of size 25cm x 25cm, 25mm thick laid as in floor/path, set jointed and pointed in neat cement slurry with grey cement and pigment to match the shade of tile, tiles laid over and including 20 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge.
Dismantling brick terracing tiles single layer from roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition/taking out of mud from roofs, any thickness, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for Preparing surface including removing / cutting uprooting grass, vegetations and roots of small plants etc on roof and surrounding/parapit wall, loose particle, cleaned of all dust by wire brushing etc , sprinkling water on the surface and ensure water does not stand anywhere. If it is so, the roof surface shall be leveled than surface shall be painted with one coat of cold applied bituminous primer @ 0.40 ltr per sqm, applied over primed surface APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application, torching with overlaps as recommended by the manufacturer complete all as specified and as directed by Engineer-in-charge.
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for 40mm thick brick tiles (old serviceable tiles obtained from demolition/dismantled item shall be reused) laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for mild steel framed work, framed/truss work made by using hollow square/rectangular/round pipe (ERW or induction butt welded tubes conforming to latest relevant IS), including special shaped washers, bending and welding etc, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for structural steel work, framed work made by using rolled mild steel Joist, channel, angle, or tee sections, fixed independently distance pieces, cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, and cut to shape, drilled and counter sunk for screw, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 50mm thick PUF panel in approved colour made of Puf insulation in core having density 40+2 Kg/Cum sandwiched betweeen two numbers of polyster coated galvalume steel sheet including end of the puff shall be covered by galvalume sheet, these sheets shall be made out of 0.50mm thick (TCT) High tensile steel having min yield strength of 550 Mpa confirm to AZ 150 of AS-1397 with hot dip metalic coating of 55% ZN alloy having total coating mass of minimum 150 gms/sqm inclusive of both side, the material shall be coated with polyster coating paint system of 20 micron over primer of 5 micron (exposed side) & alkyd back coat of 5 micron over primer coat of 5 microns, the material shall be supplied as per drawing (approved by GE) complete all as specified and directed by Engineer-in-charge. Make :- Jindal Puf Panels/Metecno Puf Panels/Sintex Puf Panels
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing powder coated GI, E-grid suspended false ceiling grid system of size 600mmx600mm with main runner 39x29.7x0.8mm, cross tee 39x27.7x0.80mm, and wall angle 22.20x22.20x0.65mm to make grid of size 600x600mm to receive false ceiling of size 595x595mm suspended with GI wire not less than 2mm dia hanger fixed with steel dash fastener or frame purlin of the roof with butterfly clips, hold down clips etc. main runner, cross tee, wall angle, of MS galvanised (PPP COS) complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 7 to 8 mm thick exposed metal frame celing with gypsum board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmx600mm grid all as per manufacturer's instructions, finish, fixed to aluminium/ CGI frame work with hold down clips in false ceiling complete all as specified and as directed by Engineer-in-charge.
EM PORTION
Taking down carefully existing copper/aluminium point wiring (light/fan/sockets/bell/power point) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 174 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 174 but for one socket out let 5 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow,junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Taking down carefully existing copper/aluminium point wiring (light/fan/sockets points ) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed sunken boxes etc but except concealed conduit and junction boxes and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit but including 2mm thick galvanised steel pressed sunken box suitable modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). Note:- Where ever it is not feasible to cable drawn through existing PVC conduit (for ceiling fan point only) due to blocked, casing caping shall be provided by contractor without any extra cost, cost for the same shall deemed to be included in the quoted unit rate.
Supply and fixing modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No AHFSXXW061 of Havells or Techno commercial equivalent in make mentioned in Appx 'B' Note :- Inner plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular switch 5/6Amps, single pole, two way (1 module) complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No AHFSXXW102 of Havells or Techno commercial equivalent in make mentioned in Appx 'B' Note :- Inner plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular Bell Push switch, 5Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No AHFSBXW101 of Havells or Techno commercial equivalent in make mentioned in Appx 'B' Note :- Inner plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No AHFKPXW063 of Havells or Techno commercial equivalent in make mentioned in Appx 'B' Note :- Inner plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No AHFKCXW163 of Havells or Techno commercial equivalent in make mentioned in Appx 'B' Note :- Inner plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No AHFSXXW161 of Havells or Techno commercial equivalent in make mentioned in Appx 'B' Note :- Inner plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular Socket outlet 25 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. Make :- Cat part No AHFKCXW253 of Havells or Techno commercial equivalent in make mentioned in Appx 'B' Note :- Inner plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 6Amps, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection and testing, complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement electronic Bell musical type, AC 230 Volts single pole including making elctric connection and testing, complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED lamp minimum 5 star rated 12W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) CRI : Morethan 80
Material and labour for concealed wiring for TV antenna connection complete with coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a aluminium wire net drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick GI/pressed steel sunken box flush mounted of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular TV socket, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (TV socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed wiring for telephone connection complete with PVC insulated sheathed cable with copper conductor having single strand of 0.4 mm dia one pair taped for telephone wiring drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick GI/pressed steel sunken box flush mounted of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular TV socket, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (Telephone socket shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing modular type (1 module) 2 pin TV antenna connection socket outlet round flush type duly marked with symbol of TV complete all as specified and as directed by Engineer-in-charge. Note :- Inner plate for fixing the socket shall be included in point wiring item of BOQ.
Supply and fixing modular type (1 module) telephone connection socket outlet flush type duly marked with symbol of telephone complete all as specified and as directed by Engineer-in-charge. Note :- Inner plate for fixing the socket shall be included in point wiring item of BOQ.
Material and labour for concealed sub main wiring (Four run for main i.e. three phase and netural and one run for continues as earth wire connected to earth dolly etc., using red, yellow, blue, black and green colour wires as colour coding) with 10 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 25mm dia (medium quality ISI marked), on independent circuit from DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :- Five run of 10 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and fixing in replacement of LED complete fitting including batten, T-8 Retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : Morethan 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing in replacement LED light fitting 1 x 10 Watt, appx 2 feet long environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing in replacement of LED Bulkhead fitting 1 x 10 Watt, complete with Standard profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-65. (g) CCT : 6500K (h) Pressure die cast Aluminium housing (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Morethan 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing in replacement energy efficient LED street light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply, installation, commissioning and testing of factory made LT panel Board (main control board) of size size 150cm X 100cm X 15 cm fixed on/inside wall (front side open-able including locking arrangements and handle), dust proof, vermin proof made out of CRCA sheet 2 mm thick powder coated, provision of 7 compartments for accommodating the electronic meter-04 Nos, MCCB-01 No, MCB-05 Nos, stair case circuit, separate bus bar chamber, including provision of rubber beading and mild steel cable glands, lugs and conduit as required, provision of air fins for ventilation, complete with internal wiring of panel board with solid conductor copper cable single core of suitable size with proper spacing, complete including all connections incoming / out going , including taking down old panel board any type with fittings complete all as directed by Engineer-in-charge and comprising of following accessories :- (i) 200 Amp rated copper bus bar with colour code mounted on epoxy insulators for phase and netural (FP) : 01 set (set of 04 bus bars) (ii) MCCB 100 Amps, FP, 415 V, 16 KA - 01 No (Incoming) (iii) MCB 63 Amps, TPN - 04 Nos (Outgoing) (iv) MCB 10 Amps, SPN, 10 KA - 01 No (Outgoing) Note :- Electronic meter shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing three phase electronic meter tamper proof LCD Display with poly carbonate cover 415 V, 10-60 Amp accuracyclass -I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data, time, current reading , load, PF, Voltage and KWH including taking down old meter complete all as specified and as directed by Engineer-in-charge. Note :- Old Electric meters shall be deposited in AGE E/M store yard.
Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) TPN, 4 Way, suitable for mounting Isolator/MCB, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in existing new DB/panel complete all as specified and as directed by Engineer-in-charge
Supply and fixing isolator, DP, 32/40 Amps, 240 volts AC supply fixing in existing new DB/panel complete all as specified and as directed by Engineer-in-charge
Supply and fixing isolator, TPN, 63 Amps, 415 volts AC supply fixing in existing new DB/panel complete all as specified and as directed by Engineer-in-charge
Supply and fixing Protector and accessories for AC starter 25 A, 2 Module grouted flush to walls complete all as specified and as directed by Engineer-in-charge
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing electric water heater (Geyser) storage type ABS body of capacity 25 Ltrs, 5 Star rating, 230V, single phase AC supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with Hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece, PVC connection for hot and cold water, three core PVC Insulated PVC Sheathed copper conductor flexible cable including 15Amp plug suitable for existing socket and fixing material, 04 No Nut bolts etc. Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.
Supply and fixing exhaust fan (Air fresher) made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 MM complete all as specified and as directed by Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 50 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, including taking out old unserviceable cable any size complete all as specified and as directed. Note :- (i) Excavation, earth work, sand cushioning, brick protection, boring/cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Material and labour for sand cushioning, with dry and clean fine river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Supply and fixing in replacement GI tubing light grade of size 80 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under road for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing in replacement GI tubing light grade of size 50 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under road for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)
Taking up or down existing galvanised steel water tubing (GI pipe) 40mm bore including fitting/connection from trench, wall, floor etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 40mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. laid in trenches or laid in floor including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge. Note :- (i) Excavation and earth work shall be measured & paid separately under appropriate item of this Schedule.)
Supply and fixing gun metal, globe or gate valve (ISI marked), with iron wheel head, screwed both ends suitable for 40mm bore iron pipes including taking down old unserviceable valve complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Material and labour for cutting of road/floor etc any type upto 45cm width and depth for laying of cable/pipe, after that returning filling including spreading, leveling watering and well ramming in layers upto 30cm in soft/loose soil and hardcoer and top layer 15cm thick filling by using PCC (1:3:6) type C2 using 40mm graded stone aggregate to match the existing level of road/floor complete all as specified and as directed.
Boring hole/Excavation by trenchless technology for boring of holes under road, pavement, hardstanding using trenchless boring machine or by means of manual manpower suitable for inserting GI pipe any dia upto 50mm including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.
STELLAR PROJECTS
M/s RAMESH KUMAR VERMA CONTRACTORS
BHULLARCONSTRUCTIONS
M/s GURFATEH BUILDERS
M/s Balvinder Singh Engineer and Contractors
M/S VERMA BUILDERS & DEVELOPERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .