Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹42.9 L+₹38,325 (0.90%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹45.4 L+₹2.8 L (6.66%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹47.2 L+₹4.7 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹49.7 L+₹7.1 L (16.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 Mar 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
COMPREHESIVE REPAIR MAINTENANCE OF CI DI GI PIPE LINES PUMPS AND MOTORS MOTOR PANELS AND ALLIED WORKS AT TBII AREA AND DUNKRIK LINE AREA ETC UNDER AGE EMI IN GE C KIRKEE
2022_MES_509785_1
8545/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
TB III AND DUNKRIK AREA
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹98,000
Yes
26 Mar 2022
22 Feb 2022
23 Mar 2022
22 Feb 2022
21 Mar 2022
9 Mar 2022
22 Feb 2022 - 8 Mar 2022
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for lying of pipe etc and getting out in soft / loose soil complete all as specified and directed by Engineer in Charge.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for lying of pipe etc and getting out in Road cuttings/Soft Disintegrated Rock complete all as specified and directed by Engineer in Charge.
Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engineer in Charge.
Returning filling in trenches including spreading ,leveling,watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engineer in Charge.
Material and Labour for repairs, renewal of pipe lines and attending emergency water supply breakdown complaints within 6 hours on telephonic intimation/SMS by arranging JCB/Excavator for excavation, braking footpath paved with PCC block, PCC flooring, bituminous road etc upto 4 meters depth, dewatering with pump, cutting and removing defective pipes, lowering the required size of pipes, valves and fitting with the help of crane and welding works if any, refilling the trench after repair with excavated soil, relaying of removed PCC blocks and matching with sorroundings etc complete including PCC work complete all as specified and as directed by Engineer in Charge.
Note for item no 5: (i) Material required for the repairs such as pipe, fittings, valve, mechanical joints, PCC, PCC blocks etc will be measured and paid separately as supply only in relevant items of this schedule. (ii) Items such as rubbergaskets, nuts, bolts and washers etc are to be included in the quoted rate. (iii) The contractor shall provide sufficient barricades, caution tape, danger boards etc at work site to avoid any accidents at site. (iv) If the contractor fails to start the work within 6 hours on receipt of telephonic intimation/SMS.
Taking up cast iron water mains (incl all fitting) 80mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and directed by Engineer in Charge.
Taking up cast iron water mains (incl all fitting) 100mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and directed by Engineer in Charge.
Taking up cast iron water mains (incl all fitting) 150mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and directed by Engineer in Charge.
Taking up cast iron water mains (incl all fitting) 200mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and directed by Engineer in Charge.
Taking up cast iron water mains (incl all fitting) 250mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and directed by Engineer in Charge.
Taking up cast iron water mains (incl all fitting) 300mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and directed by Engineer in Charge.
Material and Labour for Cutting cast iron pipes in position for insertion of fittings, mechanical joints etc for bore of pipe 80mm dia complete all as specified and as directed by Engineer in Charge.
Material and Labour for Cutting cast iron pipes in position for insertion of fittings, mechanical joints etc for bore of pipe 100mm complete all as specified and as directed by Engineer in Charge.
Material and Labour for Cutting cast iron pipes in position for insertion of fittings, mechanical joints etc for bore of pipe 150mm complete all as specified and as directed by Engineer in Charge.
Material and Labour for Cutting cast iron pipes in position for insertion of fittings, mechanical joints etc for bore of pipe 200mm complete all as specified and as directed by Engineer in Charge.
Material and Labour for Cutting cast iron pipes in position for insertion of fittings, mechanical joints etc for bore of pipe 250mm complete all as specified and as directed by Engineer in Charge.
Material and Labour for Cutting cast iron pipes in position for insertion of fittings, mechanical joints etc for bore of pipe 300mm complete all as specified and as directed by Engineer in Charge.
Laying only 80 mm bore CI pipes with spigot and socket ends laid in trenches including thorough cleaning of old CI pipe by descaling internally with steel brushes equal to bore of pipe ,scraping, washing properly complete all as specified and directed by Engineer in Charge.(Note :- Pipe retrived from item no.6 which is found serviceable in every respect as decided by Engineer in charge shall only be used and measured.)
All as per item no.18 above but for 100mm bore CI Pipe complete all as specified and directed by Engineer in Charge.(Note :- Pipe retrived from item no.7 which is found serviceable in every respect as decided by Engineer in charge shall only be used and measured.)
All as per item no.18 above but for 150mm bore CI Pipe complete all as specified and directed by Engineer in Charge. (Note :- Pipe retrived from item no.8 which is found serviceable in every respect as decided by Engineer in charge shall only be used and measured.)
All as per item no.18 above but 200mm complete all as specified and directed by Engineer in Charge. (Note :- Pipe retrived from item no.9 which is found serviceable in every respect as decided by Engineer in charge shall only be used and measured.)
All as per item no.18 above but 250mm complete all as specified and directed by Engineer in Charge. (Note :- Pipe retrived from item no.10 which is found serviceable in every respect as decided by Engineer in charge shall only be used and measured.)
All as per item no.18 above but 300mm complete all as specified and directed by Engineer in Charge. (Note :- Pipe retrived from item no.11 which is found serviceable in every respect as decided by Engineer in charge shall only be used and measured.)
Material & Labour for Ductile iron fittings such as bends (any type ,radius and angle), tapers any type (straight , bend, increasing, decreasing or double socket etc.),Tee piece ,single branch 'Y'junction double branch ,collar etc. caps and plugs etc. as per IS:9523-2000 of class K-7 ,with internal cement mortor lining and external zinc and black bitumen coated of dia upto 150mm complete all as specified and directed by Engineer in Charge.
All as per item no.24 above but dia 200mm to 300mm complete all as specified and directed by Engineer in Charge.
Supply, laying, jointing & testing DI-K7 class with spigot and socket for 100 mm bore dia pipe,suitable for push on rubber joint ,with internal cement mortor lining ,and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 includding Rubber Gasket & joints as per IS:9523-2000 laid in trenches /Road / Ducts / Footpath /on wall /on floor locations complete all as specified and directed by Engineer in Charge. Make : Jindal/Electrotherm or its equivalent.
All as per item No.26 here-in-before but 150 mm bore dia complete all as specified and directed by Engineer in Charge.
All as per item No.26 here-in-before but 200 mm bore dia complete all as specified and directed by Engineer in Charge.
All as per item No.26 here-in-before but 250 mm bore dia complete all as specified and directed by Engineer in Charge.
All as per item No.26 here-in-before but 300 mm bore dia complete all as specified and directed by Engineer in Charge.
Material and Labour for laying, jointing and testing MS Pipe 450mm to 500mm bore, 8mm thick, externally coated with anti corrosive paint with welded joints laid in trenches in short length as required at site upto 4 meter in depth including taking out defective pipes complete all as specified and as directed by Engineer in Charge.
Taking up worn out GI steel tubing of 15mm bore incl all fittings from trenches complete all as specified and directed by Engineer in Charge.
Taking up worn out GI steel tubing of 20mm bore incl all fittings from trenches complete all as specified and directed by Engineer in Charge.
Taking up worn out GI steel tubing of 25mm bore incl all fittings from trenches complete all as specified and directed by Engineer in Charge.
Taking up worn out GI steel tubing of 40 to 50 mm bore incl all fittings from trenches complete all as specified and directed by Engineer in Charge.
Taking up worn out GI steel tubing of 80mm bore incl all fittings from trenches complete all as specified and directed by Engineer in Charge.
Taking up worn out GI steel tubing of 100mm bore incl all fittings from trenches complete all as specified and directed by Engineer in Charge.
Taking up worn out GI steel tubing of 150mm bore incl all fittings from trenches complete all as specified and directed by Engineer in Charge.
Material & Labour for Laying in trenches/fixed to wall Galvanised steel water tubing 15mm bore, medium grade with and including all necessary fittings complete all as specified and as directed by Engineer in charge.
All as per item no.39 above but for 20 mm bore pipe complete all as specified and directed by Engineer in Charge.
All as per item no.39 above but for 25 mm bore pipe complete all as specified and directed by Engineer in Charge.
All as per item no.39 above but for 40 mm bore pipe complete all as specified and directed by Engineer in Charge.
All as per item no.39 above but for 50 mm bore pipe complete all as specified and directed by Engineer in Charge.
All as per item no.39 above but for 80 mm bore pipe complete all as specified and directed by Engineer in Charge.
All as per item no.39 above but for 100 mm bore pipe complete all as specified and directed by Engineer in Charge.
All as per item no.39 above but for 150 mm bore pipe complete all as specified and directed by Engineer in Charge.
Material & Labour for taking apart and reassembling stuffing box of sluice valve 80mm to 150mm SS Spindle in position suitbale for existing sluice valve including replacement of gland packing complete all as spcified and as directed by Engineer in Charge. Note:- Nuts,bolts & washers required for the work shall be measured and paid separately as supply only under relevant item of this schedule.
Material & Labour for taking apart and reassembling stuffing box of sluice valve 200mm to 450mm SS Spindle in position suitbale for existing sluice valve including replacement of gland packing complete all as spcified and as directed by Engineer in Charge. Note:- Nuts,bolts & washers required for the work shall be measured and paid separately as supply only under relevant item of this schedule.
Supply & Fix in repairs CI body non raising spindle sluice valve with cast iron wheel, of size 80mm bore, class PN-1.6 with SS spindle with brass nut, both ends flanged confirming to IS-14846 with standard bolts hole , fixing with nuts , bolts , washers ,rubber gasket etc complete in position of pipe line complete all as specified and directed by Engineer in Charge. Note:-Rate of Rubber gasket required for the work shall be deemed to be inclusive in the quoted rate.
All as per item no 49 above but 100mm bore complete all as specified and directed by Engineer in Charge.
All as per item no 49 above but 150mm bore complete all as specified and directed by Engineer in Charge.
All as per item no 49 above but 200mm bore complete all as specified and directed by Engineer in Charge.
All as per item no 49 above but 250mm bore complete all as specified and directed by Engineer in Charge.
All as per item no 49 above but 300mm bore complete all as specified and directed by Engineer in Charge.
All as per item no 49 above but 450mm bore complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair Cast Iron air release valve with air outlet, 100mm dia, flanged including required fittings at site and making necessary modification/arrangements on CI/MS/DI pipeline of bore upto 450mm complete all as specified and as directed by Engineer in Charge.
Material and labour for dismantling & taking out carefully sluice valve head with gate, spindle and stuffing box of size 80 mm to 450 mm bore in position, replacement of worn out SS/GM spindle & SS/GM nut with new SS/GM spindle & SS/GM nut for sluice valve class PN 1.6/1.0 and refixing gate, spindle, nut, valve head with stuffing box incl necessary PTFE gland packing,nuts ,bolts ,washers ,gland bolts, rubbers gasket etc complete all as specified and as directed by Engineer in Charge. Note:-(1) SS/GM spindle ,nuts shall be measured and paid separately as supply only. (2) Nuts ,bolts & washers whenever require new shall be measured and paid separately as supply only (3) PTFE gland packing and Rubber gasket shall be inclusive of the quoted rate of this item.
Supply only SS spindle for sluice valve class PN1.6/1.0, 80 mm to 150 mm bore complete all as specified and as directed by Engineer in Charge.
Supply only SS spindle for sluice valve class PN1.6/1.0, 200 mm to 300 mm bore complete all as specified and as directed by Engineer in Charge.
Supply only SS spindle for sluice valve class PN1.6/1.0, 450 mm bore complete all as specified and as directed by Engineer in Charge.
Supply only SS nut suitably threaded internally as per spindle thread and to the size of wedge of valve gate for sluice valve 80 mm to 150 mm bore class PN 1.6/1.0 complete all as specified and as directed by Engineer in Charge.
Supply only SS nut suitably threaded internally as per spindle thread and to the size of wedge of valve gate for sluice valve 200 mm to 300 mm bore class PN 1.6/1.0 complete all as specified and as directed by Engineer in Charge.
Supply only SS nut suitably threaded internally as per spindle thread and to the size of wedge of valve gate for sluice valve 450 mm bore class PN 1.6/1.0 complete all as specified and as directed by Engineer in Charge.
Supply & Fix in repair gun metal gate valve with iron wheel head, screwed both ends for pipes 15mm bore complete all as specified and directed by Engineer in Charge.
All as per item No. 64 above but of size 20 mm bore complete all as specified and directed by Engineer in Charge.
All as per item No. 64 above but of size 25 mm bore complete all as specified and directed by Engineer in Charge.
All as per item No.64 above but of size 40 mm bore complete all as specified and directed by Engineer in Charge.
All as per item No.64 above but of size 50 mm bore complete all as specified and directed by Engineer in Charge.
Supply & fix in repairs cast iron swing check non return valve confirming to IS:5312(Part I) of 1969, both end flanged with rubber gasket & nuts, bolts & washers of sizes 150 mm bore complete all as specified and directed by Engineer in Charge.
Supply & fix in repairs cast iron swing check non return valve confirming to IS:5312(Part I) of 1969, both end flanged with rubber gasket & nuts, bolts & washers of sizes 100 mm bore complete all as specified and directed by Engineer in Charge.
Supply & fix in repairs cast iron swing check non return valve confirming to IS:5312(Part I) of 1969, both end flanged with rubber gasket & nuts, bolts & washers of sizes 80 mm bore complete all as specified and directed by Engineer in Charge.
Supply & fix in repairs cast iron foot valve confirming to IS:4038, flanged end with rubber gasket & nuts, bolts & washers of sizes 150/200 mm bore complete all as specified and directed by Engineer in Charge.
Supply & fix in repairs cast iron foot valve confirming to IS:4038, flanged end with rubber gasket & nuts, bolts & washersof sizes 100 mm bore complete all as specified and directed by Engineer in Charge.
Supply & fix in repairs cast iron foot valve confirming to IS:4038, flanged end with rubber gasket & nuts, bolts & washersof sizes 80 mm bore complete all as specified and directed by Engineer in Charge.
Supply and fix mild steel screw bolts (machine made) with hexagonal heads at one end and screwed the other , each screwed end to be fitted with washers and one hexagonal nut n exc 10cm long , 10 to 20 mm dia of neck complete all as specified and as directed by Engineer in Charge.
Supply & Fix MS mechanical joint with rubber washer, mild steel screw bolts (machine made) with screwed both ends of dia as per flange hole and required length each screwed end to be fitted with washers and one hexagonal nut suitable for bore of pipe 80mm complete all as specified and directed by Engineer in Charge.
All as per item no. 76 above but suitable for bore of pipe 100mm complete all as specified and directed by Engineer in Charge.
All as per item no. 76 above but suitable for bore of pipe 150mm complete all as specified and directed by Engineer in Charge.
All as per item no. 76 above but suitable for bore of pipe 200mm complete all as specified and directed by Engineer in Charge.
All as per item no. 76 above but suitable for bore of pipe 250mm complete all as specified and directed by Engineer in Charge.
All as per item no. 76 above but suitable for bore of pipe 300mm complete all as specified and directed by Engineer in Charge.
Material and Labour for PCC 1:5:8 Type C5 block masonry, over 10cm in width, built in cement mortar 1:6, complete all as specified inc;uding demolition of precast cement concrete block walling built in cement mortar complete all as specified and as directed by Engineer in Charge.
Material and labour for cement plaster 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and fair incl taking down plaster any description , racking out joints , hacking for key , scrubbing down with water complete all as specified and directed by Engineer in Charge.
Material and labour for PCC 1:3:6 Type-C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete including necessary form work and including demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer in Charge.
Material & Labour for Mild steel framed work with ends of bars souldered, welded or riveted or forced into spikes, framed guard bars, ladders, framed balusters, walkways, railings, gates, frame work of water rank, valvepit and similar work conforming to Fe 290 Gde E165 including painting with one coat of red oxide primer and one coat of anticorrosive black bituminous paint including dismantling of mild steel work of nay description complete all as specified and as directed by Engineer in Charge.
Material & Labour for one coat of synthetic enamel paint to old steel surfaces of any descripton including preparation of surfaces, for area over 10cm in width or girth, not otherwise specially provided for complete all as specified and as directed by Engineer in Charge.
Material & Labour for Preparation of Old surfaces (Plastered or un-plastered) of walls and applying One coat of cement base paint complete all as specified and as directed by Engineer in Charge.
Material & Labour for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed by Engineer in Charge.
Material & Labour for 75mm thick Cement concrete 1:4:8 Type D-2 (using 40mm graded agg) as in sub base of floors/interlocking tiles complete all as specified and as directed by Engineer in Charge.
Material & Labour for Machine pressed precast cement conctete interlocking paver block rubber moulded glossy finished any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment over and including 50mm thick sand cushion including dismantling of existing Interlocking tiles of any type/size and in any position complete all as specified and directed by Engineer in Charge.
Supply and Fix hot dipped galvanized chain link fencing with zinc coating, nominal height of 2400mm, pitch of 50mm and wire dia 3.15mm (approx weight 2.55 Kg/Sqm) complete all as specified and directed by Engineer in Charge.
Material & Labour for Mild steel work of angle fixed independently for fencing post and others conforming to Fe 410-A including cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts including dismantling, taking down unserviceable one complete all as specified and as directed by Engineer in Charge.
Material and Labour for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete for support of chain link fencing including dismantling, taking down unservicebale one complete all as specified and as directed by Engineer in Charge.
Dismantling and taking out complete pump of any type, of capacity 90 HP to 100 HP from foundation including dismantling suction and delivery pipe connection from pump, carrying to workshop and back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete include testing, commissioning complete all as specified and as directed by Engineer in Charge. (Note:- (i) Small spares such as gaskets, nuts, bolts and washers, screws, consumable like grease etc in deemed to included in the rate quoted by the bidder. (ii) Parts to be replaced shall be measured and paid separately as supply only under relevant item of this schedule)
Supply only Ball Bearing (DE) suitable for Pump of capacity 90 to 100 HP
Supply only Ball Bearing (NDE) suitable for Pump of capacity 90 to 100 HP
Supply only Impeller suitable for Pump of capacity 90 to 100 HP
Supply only Pump Shaft suitable for Pump of capacity 90 to 100 HP
Supply only Lantern Ring suitable for Pump of capacity 90 to 100 HP
Supply only Mechanical Seal suitable for Pump of capacity 90 to 100 HP
Supply only Water Deflector suitable for Pump of capacity 90 to 100 HP
Supply only Bush suitable for Pump of capacity 90 to 100 HP
Supply only Key Impeller suitable for Pump of capacity 90 to 100 HP
Supply only Gland Packing suitable for Pump of capacity 90 to 100 HP
Supply only Gasket Set suitable for Pump of capacity 90 to 100 HP
Dismantling and taking out complete pump of any type, of capacity 15 HP to 30 HP of different models from foundation including dismantling suction and delivery pipe connection from pump, carrying to workshop and back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete include testing, commissioning complete all as specified and as directed by Engineer in Charge. (Note:- (i) Small spares such as gaskets, nuts, bolts and washers, screws, consumable like grease etc in deemed to included in the rate quoted by the bidder. (ii) Parts to be replaced shall be measured and paid separately as supply only under relevant item of this schedule)
Supply only Ball Bearing (DE) suitable for Pump of capacity 15 to 30 HP
Supply only Ball Bearing (NDE) suitable for Pump of capacity 15 to 30 HP
Supply only Impeller suitable for Pump of capacity 15 to 30 HP
Supply only Pump Shaft suitable for Pump of capacity 15 to 30 HP
Supply only Lantern Ring suitable for Pump of capacity 15 to 30 HP
Supply only Mechanical Seal suitable for Pump of capacity 15 to 30 HP
Supply only Water Deflector suitable for Pump of capacity 15 to 30 HP
Supply only Bush suitable for Pump of capacity 15 to 30 HP
Supply only Key Impeller suitable for Pump of capacity 15 to 30 HP
Supply only Gland Packing suitable for Pump of capacity 15 to 30 HP
Supply only Gasket Set suitable for Pump of capacity 15 to 30 HP
Dismantling and taking out complete pump of any type, of capacity 5 HP to 10 HP of different models from foundation including dismantling suction and delivery pipe connection from pump, carrying to workshop and back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete include testing, commissioning complete all as specified and as directed by Engineer in Charge. (Note:- (i) Small spares such as gaskets, nuts, bolts and washers, screws, consumable like grease etc in deemed to included in the rate quoted by the bidder. (ii) Parts to be replaced shall be measured and paid separately as supply only under relevant item of this schedule)
Supply only Ball Bearing (DE) suitable for Pump of capacity 5 HP to 10 HP
Supply only Ball Bearing (NDE) suitable for Pump of capacity 5 HP to 10 HP
Supply only Impeller suitable for Pump of capacity 5 HP to 10 HP
Supply only Pump Shaft suitable for Pump of capacity 5 HP to 10 HP
Supply only Lantern Ring suitable for Pump of capacity 5 HP to 10 HP
Supply only Mechanical Seal suitable for Pump of capacity 5 HP to 10 HP
Supply only Water Deflector suitable for Pump of capacity 5 HP to 10 HP
Supply only Bush suitable for Pump of capacity 5 HP to 10 HP
Supply only Key Impeller suitable for Pump of capacity 5 HP to 10 HP
Supply only Gland Packing suitable for Pump of capacity 5 HP to 10 HP
Supply only Gasket Set suitable for Pump of capacity 5 HP to 10 HP
Dismantling, taking out induction motor 90 HP to 100 HP from foundation by removing electric connecion, coupling carefully and including transportation to workshop and back after repair complete and reassembling and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning , properly aligning and testing complete all as specified and as directed by Engineer in Charge.
Dismantling, taking out induction motor 15 HP to 30 HP from foundation by removing electric connecion, coupling carefully and including transportation to workshop and back after repair complete and reassembling and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning , properly aligning and testing complete all as specified and as directed by Engineer in Charge.
Material and Labour for complete rewinding of motor, any type, after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in slots, rewinding with existing size of super enamelled copper wire, with and including required binding, bonding,insulaton, varnishing and drying and proper testing after rewinding for the motor of Capacity 90 HP to 100 HP complete all as specified and as directed by Engineer in Charge.
Material and Labour for complete rewinding of motor, any type, after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in slots, rewinding with existing size of super enamelled copper wire, with and including required binding, bonding,insulaton, varnishing and drying and proper testing after rewinding for the motor of Capacity 15 HP to 30 HP complete all as specified and as directed by Engineer in Charge.
Dismantling, taking out induction motor 5 HP to 10 HP from foundation by removing electric connecion, coupling carefully and including transportation to workshop and back after repair complete and reassembling and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning , properly aligning and testing complete all as specified and as directed by Engineer in Charge.
Material and Labour for complete rewinding of motor, any type, after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in slots, rewinding with existing size of super enamelled copper wire, with and including required binding, bonding,insulaton, varnishing and drying and proper testing after rewinding for the motor of Capacity 5 HP to 10 HP complete all as specified and as directed by Engineer in Charge.
Repair/Maintenance/Overhauling in situ of pump starter panel by dismantling taking out old damaged panel wiring, replacement of contactor, relays, timer, push buttons, single phase preventor, voltmeter, ammeter, LED indicator and other miscellaneous items as required and testing after completion of work Complete all as specified and as directed by Engineer in Charge.
Supply & Fix AC contactor, 3 Pole, 3 Ph ,415 Volt, AC, 50Hz, Type ML-2 to ML-5 complete all as specified and as directed by Engineer in Charge. Make:- L&T or equivalent from list of make as approved by GE.
Supply & Fix AC contactor, 3 Pole, 3 Ph ,415 Volt, AC, 50Hz, Type ML-10 complete all as specified and as directed by Engineer in Charge. Make:- L&T or equivalent from list of make as approved by GE.
Supply & Fix AC Side mounting add on aux contact block for contactor complete all as specified and as directed by Engineer in Charge. Make:- L&T or equivalent from list of make as approved by GE.
Supply & Fix AC front add on aux contact block for contactor complete all as specified and as directed by Engineer in Charge. Make:- L&T or equivalent from list of make as approved by GE.
Supply & Fix Thermal over load relay for 3 phase AC Motor starter, relay setting range 9.0 to 15.0 Amps complete all as specified and as directed by Engineer in Charge. Make:L&T or equivalent from list of make as approved by GE.
Supply & Fix Electronic timer,3-30 sec415V, make-L&T or as per existing make as approved by GE.
Supply & Fix Motor Protection relay, O/L range 1.2 Amps complete all as specified and as directed by Engineer in Charge. Make:L&T or equivalent from list of make as approved by GE.
Supply & Fix single phase preventor relay, make-L&T or as per existing make as approved by GE.
Supply & Fix LED Indication lamp (R-Y-B) as per existing size complete all asspecified and as directed by Engineer in Charge.
Supply & Fix starter push button (Red/Green) as per existing size complete all asspecified and as directed by Engineer in Charge.
Supply & Fix in repairs submerssible flat copper cable conductor 3 Core 10 Sqmm 1100 volts grade complete all as specified and as directed by Engineer in Charge. Make: Finolex/KEI/Havells
Repair/Maintenance of unserviceable submersible pump of 15HP capacity by lifting from UG sump and dismantling and strip openeing of 3 phase 415 Volts, AC Submerssible pump set, transporting the pump set to workshop for repair including replacement of unserviceable parts of pump such as GM impeller, neckring, bowl assembly, bushes, coupling, lock, sand cup, CI intermediate bowl, S/S pump shft etc including testing at site on full load complete all as specified and directed by Engineer in Charge.
Note for itme no 115: (i) Rate quoted by contractor is deemed to be inclusive of minor spares like gland, grease, nut bolts and major spares required for work shall be measured and paid separately and rate quoted shall be deemed to be inclusive of fixing charges of major new spares under this item. (ii) Contractor should visit site before quoting the rates. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor shall make arrangement for pluging suction and discharge line with dead flanges without extra cost, so that pumping of installation is not disturbed and there is no leakage of water. (v) The defective parts such as pump shaft, impeller, neckring, coupling, lock, gun metal bushes, sand cap etc will be measured and paid separately under respective item of this schedule.
Supply only Pump shaft stainless steel sleeve suitable for 15 HP submerssible pump complete all as specified and as directed by Engineer in Charge.
Supply only Impeller bronze/Gun metal suitable for 15 HP submerssible pump complete all as specified and as directed by Engineer in Charge.
Supply only Neckring Gun metal suitable for 15 HP submerssible pump complete all as specified and as directed by Engineer in Charge.
Supply only Gun metal bowl bushes suitable for 15 HP submerssible pump complete all as specified and as directed by Engineer in Charge.
Supply only Cast Iron suction/discharge case bowl suitable for 15 HP submerssible pump complete all as specified and as directed by Engineer in Charge.
Supply only Sand Cap suitable for 15 HP submerssible pump complete all as specified and as directed by Engineer in Charge.
Supply only Cast Iron intermediate bowl suitable for 15 HP submerssible pump complete all as specified and as directed by Engineer in Charge.
Repair/Servicing of unserviceable submersible motor of 15HP, 3 Phase 415 Volts by lifting from UG sump, transporting the pump set to workshop for repair, dismantling and strip opening, rewinding with PVC insulated superior quality water proof copper winding wire of suitable size/gauge and number of turns including replacement of insulating material including new submerssible cable of suitable size for connection from motor to outside upto a length of 1.5m and reassembling inlcuding testing at site on full load complete all as specified and directed by Engineer in Charge.
Note for item no 123: (i) The defective parts such as thurst plate, bearing, sleeve, pad, bush etc will be measured and paid separately under respective item of this schedule. (ii) Contractor should visit site before quoting the rates. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) Cost for repair,servicing,complete checking, machine work etc whatever is required for work like cutting, grinding etc is deemed to be inclusive in the rate quoted by the Contractor.
Supply & Fix Thurst plate suitable for submerssible motor of capacity 15 HP complete all as specified nad as directed by Engineer in Charge.
Supply & Fix Thurst pad suitable for submerssible motor of capacity 15 HP complete all as specified nad as directed by Engineer in Charge.
Supply & Fix Bearing suitable for submerssible motor of capacity 15 HP complete all as specified nad as directed by Engineer in Charge.
Supply & Fix Bush suitable for submerssible motor of capacity 15 HP complete all as specified nad as directed by Engineer in Charge.
Material and Labour for fabrication, supply and fixing of sign Board of size 3.5m X 1m X 0.5m with angle iron frame duly welded of size 30mm X 30mm X 3mm thick, pasted with flex board duly printed letters in white colour on dark blue background prewired with and including LED lighting 25 Watt, connecting cable weatherproof 4 Sqmm 2 Core from switchboard including taking out old signboard at pump house complete all as specified and as directed by Engineer in Charge.
Supply of alum ferric free form impurity class I suitable for drinking water specification complete all as specified and as directed by Engineer in Charge. Make : Shri Rayalseema Ltd or its equivalent as approved by GE.
Material and Labour for Cleaning of RCC OH reservior 100000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete with and including writing date of cleaning with white paint (Size 80 mm X 60mm) over black blackground in epoxy paint complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC OH reservior 50000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete with and including writing date of cleaning with white paint (Size 80 mm X 60mm) over black blackground in epoxy paint complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC OH reservior 20000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete with and including writing date of cleaning with white paint (Size 80 mm X 60mm) over black blackground in epoxy paint complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC OH reservior 10000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete with and including writing date of cleaning with white paint (Size 80 mm X 60mm) over black blackground in epoxy paint complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC OH reservior 5000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete with and including writing date of cleaning with white paint (Size 80 mm X 60mm) over black blackground in epoxy paint complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC semi UG clear water sump 100000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC semi UG clear water sump 50000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC semi UG clear water sump 20000 gallon cap internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete all as specified and directed by Engineer in Charge.
Material and Labour for Cleaning of RCC semi UG sedimentation tank 150000 gallon cap in 3 compartments internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete all as specified and directed by Engineer in Charge. (Note:- Cleaning of one sedimentation tank shall be considered as one job)
Material and Labour for Cleaning of RCC semi UG sedimentation tank 50000 gallon cap in 2 compartments internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete all as specified and directed by Engineer in Charge. (Note:- Cleaning of one sedimentation tank shall be considered as one job)
Material and Labour for Cleaning of RCC semi UG sedimentation tank 100000 gallon cap in 2 compartments internally by brushing walls,floors and through washing and removing all dirt ,muds etc through drain out pipe complete all as specified and directed by Engineer in Charge. (Note:- Cleaning of one sedimentation tank shall be considered as one job)
Supply & fixing of new nylon brush (Hard quality) with wooden base of size 250X120mm with hard wood handle 30mm dia and 5 mtr long as per manufacturer instruction, fix with telescopic handle complete all as specified and and directed by Engineer in Charge.
Material & Labour for cleaning of MES water supply installations/Area by surface dressing by removing small unequalities n.exc 15cm deep (including removing of vegetations/Shrubs/Creepers/Under-growth), cleaning of drains & carrying away the rubbish to a distance of n.exc 50m away at various installations complete all as specified and as directed by Engineer in Charge.
Supply only Granular Chlorine, Grade I, with chlorine constant 65% drinking water purification complete all as specified and as directed by Engineer in Charge. Make : Bharti Waters Pvt Ltd or its equivalent as approved by GE.
Material & Labour for chemical testing of water sample at PMC or at any government recognized water testing lab for the following parameters :- Turbidity, pH, Total Hardness, Alkalinity, Chloride, Nitrate,TDS, Iron, Flourides, Calcium, MAgnesium, Aluminium, Sulphide, Lead, Arsenic, Mangnese, Copper, Mercury, Residual Chlorine etc complete all asspecified and as directed by Engineer in Charge.
Note for item No 144: (i) Sample of water shall be collected from each pump house as specified by Engr-in-charge in sterilised bottle provided by the Lab. Rate quoted by Contractor is deemed to be included of the cost of bottle. (ii) Cost of transportation of water sample to the lab and collection of duly signed lab report is included inrate quoted by the bidder. Cost of report & testing shall be borne by the bidder.
ONKAR ELECTRIC AND GENERAL STORE
JP ENTERPRISES
K.K.Enterprises
Takshashila electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .