Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.8 L+₹54,409.40 (1.59%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹37.8 L+₹3.6 L (10.6%)Rejected-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-AOC L3 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
30 Nov 2022, 6:00 pmClosed
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
REPAIR, REPLACEMENT AND MAINTENANCE OF UNSERVICEABLE ITEMS OF LT DISTRIBUTION SYSTEM, DEFECTIVE ITEMS OF STREET LIGHTS, SECURITY LIGHTS AND DG SETS, AMF PANELS AND MISC ITEMS AT 9 BRD UNDER GE (AF) LOHEGAON AT AIR FORCE STATION PUNE
2022_MES_561266_1
8629/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹86,000
Yes
9 Feb 2023
4 Nov 2022
7 Dec 2022
4 Nov 2022
30 Nov 2022
18 Nov 2022
Amount
M&L for servicing of DG set 62.5 KVA to 125 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed. ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
M&L for servicing of DG set 160 KVA to 250 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed.( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
M&L for servicing of DG set 500 KVA to 750 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed. ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
Material only for the following item of DG set 62.5 KVA to 125 KVA DG set be incorporated in repairs for item No 1.00 complete all as specified and directed.
(a) Fuel Filter
(b)Oil Filter element with 'O' ring
(c) Fan belt
(d) Alternator belt
(e) Radiator hose pipe inlet/outlet
(f) Solenoid switch 12 volts,DC
(g) Oil Pressure Pipe
(h) Fuel Pressure Pipe
Material only for the following item of DG set 160 KVA to 250 KVA to be incorporated in repairs for item No 2.00 complete all as specified and directed.
(a) Fuel Filter
(b) Oil Filter element with 'O' ring
(c) Fan belt
(d) Alternator belt
(e) Radiator hose pipe inlet/outlet
(f) Solenoid switch 12/24 volts,DC
(g) Oil Pressure Pipe
(h) Fuel Pressure Pipe
Material only for the following item of DG set 500 KVA to 750 KVA to be incorporated in repairs for item No 3.00 complete all as specified and directed.
(a) Fuel Filter
(b)Oil Filter element with 'O' ring
M &L for Removing the fuel injection pump (FIP) & injectors from DG set cap 62.5 KVA to 160 KVA and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning complete all as specified and directed. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
Taking down defective self starter 12 Volt of DG set of cap from 20KVA and below 160 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
(a) Rewinding the burnt field coil.
(b) Rewinding the burnt armature coil with commutator.
(c) Replacement of bush/ bearing.
(d) Replace the worm out carbon brush with brush holder.
(e) Replacement of clutch.
(f) Replacement of solenoid switch.
(g) Replacement of Bentex drive.
Taking down defective self starter 24 Volt of DG set of cap from 160 KVA to 750 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
(a) Rewinding the burnt field coil.
(b) Rewinding the burnt armature coil with commutator.
(c) Replacement of bush/ bearing.
(d) Replace the worm out carbon brush with brush holder.
(e) Replacement of clutch.
(f) Replacement of solenoid switch.
(g) Replacement of Bentex drive.
M&L for disconnecting the U/S alternator capacity of 30 KVA to 160 KVA, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning complete all as specified and directed.
Taking down old US contactor and S&F new contactor for the following range complete all as specified and directed.
(i) MNX 40 contactor 40A, 415 volt, 3 pole
(ii) MNX80 contactor 80A, 415 volt, 3 pole 2NO+2NC
(iii) MNX225 contactor 225 A, 415 volt, 3 pole 2NO+2NC
Material and labour for replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as specified and directed.
Material and labour for replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as specified and directed.
M & L for replacement of brass battery terminal suitable for lead Acid Battery 12 V 40 AH to 12 V , 180 AH complete all as specified and directed.
M & L for maintenance servicing and complete checking of automatic main failure (AMF) panel of any capacity including replacement of worn out parts, copper cables, relay of suitable range, toggle switches, indicator & repair of Ammeter, Voltmeter complete and testing complete all as specified and directed. Note :- Spare parts required will be measured and paid separately under relevant item of this Schedule here after.
(a) Toggle switch suitable for AMF panel.
(b) CT's of range 62.5 to 400 KVA
(c) Relay of range 62.5 KVA to 400 KVA.
(d) Ammeter digital type square flush type
(e) Voltmeter digital type square flush type
(f) Copper wire single core for internal connection.
(g) Voltage monitoring relay (digital type)
(h) DG set digital Controller
M&L for taking out diesel from the fuel tank of DG set of capacity 20 KVA to 160 KVA and cleaning the fuel tank complete of any size complete all as specified and directed..
M&L for De-scaling & cleaning , painting (except fins area) & welding / soldering / brazing of radiator of any capacity & any type ccomplete all as specified and directed.
Supply only coolant for radiators of DG sets of capacity 30 KVA to 750 KVA complete all as specified and directed.
Supply only battery distilled water for batteries of DG sets complete all as specified and directed.
M&L for draining out old engine oil and filling new engine oil of grade as recommended by manufacturer for DG set any make and capacity complete all as specified and directed.
S & F in replacement of fuel indication transparent plastic tube of any size as per existing complete all as specified and directed.
Supply and fix in replacement of broken acoustic enclosure door hinges with stainless steel hinges complete with nut bolts etc as per site requirement of any type, cap and make of DG set complete all as specified and directed.
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 62.5 KVA to 160 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint complete all as specified and directed.
Silencer with exhaust pipe complete bends, coupling etc suitable for 100 to 400 KVA DG set including fixing arrangements and painting with silver colour over a coat of red oxide primer complete all as specified and directed.
Supply & Fix in replacement of automatic voltage regulator 62.5 to 400 KVA DG set complete all as specified and directed.
Supply and fixing of PVC Insulated, PVC Round Sheathed Multi Core Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volt 1.5 sqmm and 7 core from DG set to AMF Panel complete all as specified and directed.
S&F in repair of street light timer, astro mini type for lighting control based on sunrise/ sunset timing by lattitude/ longitude settings time switch 110-240 V AC 1 phase , base /DIN complete all as specified and directed.
Supply and fixing of 180 AH sealed lead acid battery 12 volt into DG set with all necessary connections complete all as specified and directed.
Labour only for comprehensive maintenance of and attending day to day break down of DG Set including servicing including first hand repairs, consisting of normal repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, levelling of distilled water, cleaning of main ,battery charging alternator where ever exists with vacuum cleaner including replacements of defective/ worn out spares such as diesel filters, oil filters, rubber hose pipe ,V-belt, fuel pipe and change of oils etc. and cleaning of Radiator with new at site complete all as specified and directed. Note:- (i) The maintenance cost of DG Set shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts and labour cost for fixing spares. (ii) All spares and oil replaced will be measured and paid under relevant items of schedule ‘A’. (iii) Servicing shall be carried out authorised dealer of manufacturer i.e. OEM. (iv) Non attending the complaint with in 8 Hrs @ Rs. 2000.00/day shall be recovered by the contractor. (v) Keep the complaint pending after one day @ Rs.4000.00/day shall be recovered by the contractor. (vi) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-Incharge. (g) Spares shall be measured and paid separately. (h) Comprehensive maintenance of DG sets is applicable for contract period per job and shall be measured and paid once as one job on completion of contract only
(a) 62.5 KVA to 125 KVA
(b) 160 KVA to 250 KVA
(c) 500 KVA to 750 KVA
Demolitation of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolitation of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation or as required on site etc complete all as specified and directed.
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation or as required on site complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc or as required on site etc complete all as specified and directed.
Supply and labour for Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1: 4 for laying of under ground cable duct complete all as specified and directed.
M & L for cement plaster work 10 mm thick in 1:4 Rendering on fair faces of brick work or concrete surfaces including 5 mm thick finishing to be carryout one even and smooth surface (without usingextra lime or cement) complete all as specified and directed.
M & L for MS angle iron 50x50 x 5 mm and MS steel chequred plate of thickness 5 mm for cable duct cover complete all as specified and directed
M & L for painting of MS angle / tubular/hollow trusses/structure and MS Chackered Plateetc by applying one coat of red oxide primer and two coat of bituminius paint on surface as required on site complete all as specified and directed.
M & L for preparation of surface and applying of two coats of cement based paint on walls of cable duct /wall complete all as specified and directed.
Tools & Labour for making through hole upto 450 mm thick in wall of stone machanry for passing of UG cables of any size including making good the disturbed portion of wall to match existing surface complete all as specified and directed.
Dismantling carefully old DG set of capacity 160 KVA and removing all components from sub stn Bldg and loading on transport vehicale by using crane/ suitable loader/men power as required for loading and unloading form 9 BRD sub stn and shifting to AGE E & M MES Store Yard and unloading carefully storing in store for further disposal action complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm harddense soil complete all as specified and directed.
S & F Steel work in tubular/hollow trusses/structure etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 and structural steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and directed.
S& F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with rivetted /bolted welded attachment complete all as specified and directed.
S & F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L Providing, cement concrete 1:2:4 B0 (12.5mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M & L for servicing of high mast light driving mechanism by checking alll electrical and machnical component, chain, pully, rope,. Motor etc and greasing oiling of chain, motor, pully etc servicing of motor, control panel, auxiliary contacts, replacement of u/s items i.e. toggle switch, indicator light, control wiring complete all as specified and directed.
Labour & Tools incl ladders to attanding general street light complaints for repair / maint of steert light/ flood light fitting any type and capacity after taking out from poles upto 11 mtrs height any place wihin the stn checking throughly function of drivers and connected item, removing carbon on joints, repairing of cable joints/ loose connection, making sholdering etc incl replacement of small parts like wire upto 1.5 mtr long, nut bolts, screws , insulation tape etc fixing on pole after carry out nacessary repairs and testing for smooth functioning complete all as specified and directed. Note : (a) Repairs may be carryed out as an when required basis on site i.e number of times and shall be measured and paid as per site requirement as per satisfaction of Engr-in-Charge and Spare parts like electronic drivers, ballast , lamp , ignator etc shall be measured and paid separately in respective items.
Lowering down of high mast light at any height repairing and replacement of unserviceable parts such as ignitor, capacitor, ballast, lamp electronic driver and internal and external circuit etc as required on site complete all as specified and directed. (Note : Spare / parts required for replacement shall be measured and paid seperately and lowering down work may be carry out as and when required basis for any kind of repair.)
Taking down the existing street light fitting and Supply & fix (in Repalcement) energy saving and environmental frindly long life LED Street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics IP 65/IP66 road way luminaries with LEDs as light source and lens embedded PC cover /toughened glass and impact resistance of IK07 and electronic driver fixed on pole with and including suitable dia size bracket as per manufacturer recommendation, bracket 1.5 m long complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers painting the clamps with coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.
-ditto- all as per item Ser No 50.00 above but 60 Watt complete all as specified and directed
-ditto- all as per item Ser No 50.00 above but 70 Watt complete all as specified and directed
-ditto- all as per item Ser No 50.00 above but 90 Watt complete all as specified and directed
Taking down the existing Flood lights fitting and Supply & fix (in Repalcement) energy saving and environmental frindly long life exclusive innovative flood light luminaries 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with LEDs as light source and lens embedded PC cover /toughened glass and impact resistance of IK07 and electronic driver fixed on high mast pole or any any other place as requird on site incl making all nacessary arrangement for fixing complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers complete all as specified and directed.
-ditto- all as per item Ser No 54.00 above but 120 Watt complete all as specified and directed
-ditto- all as per item Ser No 54.00 above but 170/180 Watt complete all as specified and directed
-ditto- all as per item Ser No 54.00 above but 200/210 Watt complete all as specified and directed
Taking down old,rusted, unsv Junction box of any size, type and supply & fix new junction box of size not less than 400 mm x300 mm x 190 mm, made out of Fibre material, shockproof and rustproof, cable entry from bottom. 100% wheather proof, restricted to unauthorised tapping with class FV-0 as per IS : 11731 Part-II or V-0 as per UL-94 and fixing to pole etc using suitable clamps nuts, bolts etc for accommodating and including the following complete all as specified and directed:- a) Four strip Aluminium Bus bar of capacity 100 A , 20 CM long- 01 Set b) MCB SP 10A-01 Nos
S&F in replacement of PVC insulated 1.5 sqmm copper two core conductor cable between cable loops box to fitting drawn through the pole complete all as specified and directed
Taking out the old unsv pole ,Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with black bituminous paint for embedded portion of pole complete all as specified and directed
Excavation in trenches not exc 1.5 m wide and exc 1.5 m in depth and getting it out for laying of cable / pole etc in following soil starta complete all as specified and directed
Soft/loose soil
Hard/dense soil
Soft/ disintegrated rock
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 10 cm after laying and stretching jointing and testing the cable complete all as specified and directed [Note : Measuremenet will be done after punning]
M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75) mm all complete all as specified and directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified and directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 50 mm complete all as specified and directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm complete all as specified and directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm ccomplete all as specified and directed
Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site complete all as specified and directed (Excavation and earth work will be measured seperately)
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete cable complete all as specified and directed , for following size:-
25 Sqmm 4 core
16 Sqm 4 core
25 sqmm 3.5 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
150 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
300 sqmm 3.5 core
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core multistranded cable flat or circulas 4 sqmm incl taking out old unserviceable wire complete all as specified and directed.
-ditto- all as per item Ser No 72.00 above but Service wire of size 6 Sq mm twin core
-ditto- all as per item Ser No 72.00 above but Service wire of size 10 Sq mm twin core
M&L for scrapping of old aluminium paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces and painting with two coats of aluminium paint on pole , brackets old junction boxes channels etc incl alternate 30 cm wide white and blue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed.
M&L for scrapping old painted surface with emery paper for preparation of smooth surfaces and spray painting with two coats of synthetic enamel paint (as existing on site) for LT/HT Panel/ fidder pillers boxes etc complete all as specified and directed.
Material and labour for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out removing of grass and vegetation grown around the electrical installations like transformers, LT panels, 2 pole structure, HT panels area inside the fencing complete all as specified and directed.
Trimming for branches of trees, bushes, hurbs under over head line including removal of trees branches etc to a distance not exceeding 50 mtr from over head line complete all as specified and directed.
Provn of services for finding cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and directed.
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below complete all as specified and directed for following size of joints :-
25 to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
150- 185 sqmm 3.5 core
240-300 sqmm 3.5 core
Supply and fixing LED Post top fitting 40 Watt 5700 K CCT IP 65 powder coated aluminium die cast and spun aluminium with clear diffuser suitable for landscape lighting incl making necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed.
Taking old unserviceable driver from LED light fitting and S&F LED outdoor driver with all Electricals connection as per existing make on site and testing for smooth functioning complete all as specified and directed. For following capacity of light fitting
(a) for LED light fitting 60-72 Watts
(b) for LED light fitting 80-120 Watts
(c) for LED light fitting 150 Watt
(d) for LED light fitting 250 Watt
(e ) for LED light fitting 300 Watt
Supply and fixing LED Bollard light fitting 8W IP 65 powder coated PDC aluminium body with opal diffuser weather proof 900 mm long suitable for landscape lighting incl making necessary arrangement for mounting fitting incl PCC work as reqd on site and testing complete all as specified and directed.
Taking down the existing highbay light fitting and Supply & fix (in Repalcement) energy saving and environmental friendly robost IP 65 protected LED midbay with PDC housing suitable for ceiling (Surface/Suspended) mount 120 Watt with system efficiency not less than 120 lm/W incl electronic driver fixed in ceiling/ suspended incl making all nacessary arrangement for fixing/hanging and anchering as required on site making electrical connections complete all as specified and directed.
Material and labour for cross arms, bracing supports, clamps and back plates fabricated from structural steel sections, including nut bolts, washer welding bending cold/ hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one premer coat of red oxide primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M& L for danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and tongue in signal red colour and fixed with MS clamps bolts nuts of approved size LT, 20x15cm complete all as specified and directed.
Supplying, spreading & leveling stone aggregate size of 40 mm grade to the existing sub station or complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 250 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 63 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning complete all as specified and directed.
S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. complete all as specified and directed.
S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 4x25.0 sq. mm+ 2x16.0 sq.mm earth wire including suitable size PVC Conduit/Casing capping complete all as specified and directed.
S & F Sub Main Wiring with PVC Insulated multistranded copper conductor wires with 4 x16.0 sq. mm+ 2x10.0 sq.mm earth wire including suitable size PVC Conduit/Casing capping complete all as specified and directed.
S & F Sub Main Wiring with PVC Insulated multistranded copper conductor wires with 4 x10.0 sq. mm+ 2x6.0 sq.mm earth wire including suitable size PVC Conduit/Casing capping complete all as specified and directed.
S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x4.0 sq. mm + 1x2.5 sq. mm earth wire including suitable size PVC Conduit/Casing capping complete all as specified and directed.
S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x6.0 sq. mm + 1x4.0 sq. mm earth wire including suitable size PVC Conduit/Casing capping complete all as specified and directed.
-ditto- all as per Ser item No 102.00 above but with 2x10.0 sq. mm + 1x6.0 sq. mm earth wire including suitable size PVC Conduit/Casing capping complete all as specified and directed.
-ditto- all as per Ser item No 102.00 above but with 2x16.0 sq. mm + 1x10.0 sq. mm earth wire including suitable size PVC Conduit/Casing capping complete all as specified and directed. Note for Ser No 98 to 104 : item shall be measured and paid as one length with wires as specified and PVC conduit/casing capping.
S&F Hot Dip galvanised solid perforated cable tray and cover of width 450 mm, depth 100 mm and thickness (12 SWG) fabricated from GI sheet GI coupler plate and hardware and all nacessary Vertical or horizontal fixing arrangements as required on site complete all as specified and directed.
S&F Hot Dip galvanised perforated cable tray and cover of width 100 mm, depth 25 mm and thickness (16 SWG) fabricated from GI sheet GI coupler plate and hardware and all nacessary Vertical or horizontal fixing arrangements as required on site complete all as specified and directed.
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar consisting of MCCB. 125 A 18KA - 1 Nos complete all as specified and directed.
Taking out carefully serviceable LT UG Cable/wires after disconnecting from DBs on wall/duct/cutting of walls of assorted size as required on site and re routing properly by making proper cutting in wall/cable duct clamping etc completed and making good disturbed surface of wall/floor as existing sourrounding complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 16 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete all as specified and directed.
S&F MCB SP 240 volt 6 to 32 A 'C' series complete all as specified and directed.
M/s Harshal Traders
Rama Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .