Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | ₹20.0 L Quoted ₹21.0 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹23.0 L+₹2.1 L (9.80%)Rejected-AOC | ₹23.0 L+₹2.1 L (9.80%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹23.5 L+₹2.5 L (11.9%)Rejected-AOC | ₹23.5 L+₹2.5 L (11.9%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹23.9 L+₹3.0 L (14.1%)Rejected-AOC | ₹23.9 L+₹3.0 L (14.1%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹24.3 L+₹3.3 L (15.8%)Rejected-AOC | ₹24.3 L+₹3.3 L (15.8%) | L5 | Rejected-AOC Rejected |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
21 Feb 2023, 6:00 pmClosed
GE (I) Campbell Bay
GE (I) Campbell Bay, Army land, Campbell Bay, Great Nicobar-744302
REPAIRS/REPLACEMENT/ MAINTENANCE OF UNSERVICEABLE LT SWITCH GEARS, LT POLES, LT UG CABLE, LT JUMPERS, INSULATORS, STREET LIGHT FITTINGS, TIMERS, JUNCTION BOXES AND OTHER CONNECTED MISC E/M WORKS AT INS BAAZ AND ARMY LAND UNDER GE (I) CAMPBELL BAY
2023_MES_578308_1
8057/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) Campbell Bay
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹42,000
30 Mar 2023
1 Feb 2023
23 Feb 2023
1 Feb 2023
21 Feb 2023
14 Feb 2023
Amount
Taking down LED street light fitting/ LED flood light fitting of any watts and type from any height of pole/walls/high mast of any location and detecting the fault in the fitting by checking the accessories, wiring and refixing the same after repairs & incorporating the faulty spares complete all as directed by Engineer-in-Charge. Note : Spares like driver and other accessories etc will be measured and paid separately under relevant items
Supply only LED Driver suitable for existing 45 W LED light fittings complete all as specified and directed. Make : as per OEM of light fittings (available light fittings are CG/Havells/Philips/Wipro/Bajaj) Note for item :Drivers shall be techincally compitable for existing type of fittings & frame size shall be matched to existing fittings.
Description all as per item No.2,but Driver suitable for 45 W to 60 W LED light Fittings
Description all as per item No.2,but Driver suitable for 60 W to 150 W LED light Fittings
Supply, installation, testing and commissioning integral LED Aviation Light 12W comprising aluminum Housing with polycarbonate enclosure including all necessary drilling, bolting or riveting etc complete all as specified and directed Make : Bajaj, Phillips, Havells, Wipro or equivalent Note : Necessary mounting arrangements for the lights are deemed to be inclusive in above quoted rates
Supply, installation & testing light emitting diode street light Luminaries compressing pressure, die cast housing for better aesthetics and thermal management. Comprises of extruded aluminium housing with pre-wired gear tray with LED’s & drive, heat resistant flat glass suitable gasketed for IP 66 protection, high grade power coating and fitted with toughened glass with high power LED’s of not less than 60 watt complete including taking down existing fittings all as specified and directed Make: Bajaj, Wipro, Havells, Phillips or equivalent
S&F in replacement of GI Pipe bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary arrangement for fixing the existing street light fitting on pole / wall with two sets of clamps made out of flat iron 50 x 6mm, bolts, nuts and washers including applying two coats of aluminium paint over on coat of red oxide zinc chrome primer complete all as directed by Engr-in-Charge.
M & L for PVC flexible cable with copper conductor 2.5 sqmm, 2 core, 1100 volts grade multistranded for connecting from existing junction box to street light fitting complete all as specified and directed Make : Havells / Polycab / Finolex or equivalent
Supply and fix FRP junction box of size 250 x 200 x 105 mm for loop in - loop out connections of street lights including one four pole connector mounted on existing street light poles complete all as specified and directed Make : Sintex / Hensel or equivalent
S&F in repairs factory made outdoor type street light control panel, with and including all accessories such as control switch, contactor, automatic control relay, pre-wired etc. fixed on fabricated angle iron channel of suitable size and grouting on floor, Timelite-40 Amps, 3 Pole 230/415 volts-Astronomical Time switch. Make -Indo-Asian Cat No.TLO65ASO or equivalent in Havells, Stranded, Legrand.
M&L for cleaning LT/Street light poles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPER LAC)/ BERGER (LUXOL)
M&L for cleaning LT/Street light poles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of synthetic enamel weather proof emulsion distemper paint and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPER LAC)/ BERGER (LUXOL)
M&L for Dismantling foundation of LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of paint to pole surface, type of paint shall be as per requirement of pole complete all as directed by Engineer-in-Charge. Note:- (i) The rate quoted is deemed to be inclusive of necessary crane / vehicle charges for shifting and installation of the pole incluidng new pcc foundation and earth works.
Disconnecting & taking out unserviceable MCCB 3P 63-100 A 25kA and Supply,test,install & commissioning of new MCCBs 415volts,50 Hz, suitable for exisitng panel (frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel type size of lugs, glands,nuts,bolts,spreaderer links and screws complete all as specified and directed by Engr-in-Charge for the following capacities. Note: (i)The above item shall be executed within 01 hour from the complaint recieved as and when required basis on the discretion Engr-in-charge. (ii) However any further delay in execution of the above item a penalty of 05 times the rate quoted may be deemed to be recovered at the time of RAR on the discretion of Engr-in-charge (iii) Tenderer should employed highly skilled and well known technicians for executing the above item timely (iv) Tenderer is deemed to inclusive of cable lugs / links suitable for MCCBs / MCBs Make : Legrand / L&T / Havells / Indoasian / Standard or equivalent
Description all as per item No.14,but MCCB 3P 63-100 A,36KA
Description all as per item No.14,but MCCB 3P 125 A,25KA
Description all as per item No.14,but MCCB 3P 160 A,25KA
Description all as per item No.14,but MCCB 3P 200 A,25KA
Description all as per item No.14,but MCCB 3P 250 A,25KA
Description all as per item No.14,but MCCB 4P 160 A,25KA
Description all as per item No.14,but MCCB 4P 200 A,25KA
Description all as per item No.14,but MCCB 4P 250 A,25KA
Description all as per item No.14,but MCCB 4P 315-400 A,36KA
Description all as per item No.14,but 3 pole MCB, 63 A, C-curve,10KA
Description all as per item No.14,but 3 pole MCB, 32-40 A, C-curve,10KA
Disconnecting & taking out unserviceable on load change over switch 320 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,front handle operated suitable in open execution type mounted on sheet metal enclosure and Supply,test,install & commissioning of new change over switch , suitable for exisitng panel (frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel type size of lugs, glands,nuts,bolts,spreaderer links and screws complete all as specified and directed by Engr-in-Charge for the following capacities. Note: (i)The above item shall be executed within 01 hour from the complaint recieved as and when required basis on the discretion Engr-in-charge. (ii) However any further delay in execution of the above item a penalty of 05 times the rate quoted may be deemed to be recovered at the time of RAR on the discretion of Engr-in-charge (iii) Tenderer should employed highly skilled and well known technicians for executing the above item timely (iv) Tenderer is deemed to inclusive of cable lugs / links suitable for MCCBs / MCBs Make : Legrand / L&T / Havells / Indoasian / Standard or equivalent
Description all as per item No.26,but on load change over switch 250 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,front handle operated, mounted in sheet metal enclosure closed execution type
Description all as per item No.26,but on load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,front handle operated, mounted in sheet metal enclosure closed execution type
Supply and connect LT 1100 V outdoor type cable straight through heat shrinkable epoxy joint kit suitable for the following sizes with necessary jointing materials complete all as directed by Engr-in-charge. Make :- M-SEAL/ DENSON/3-M/ RAYCHEM (a) 2 / 4 core 10 / 16 sq mm
All as per item 29 above above but 3.5 core x 25/35 sqmm
All as per item 29 above above but 3.5 core x 70/95 sqmm
All as per item 29 above above but 3.5 core x 120/150 sqmm
All as per item 29 above above but 3.5 core x 185/240 sqmm
M&L for Meggering with 1000v/2500v/5000v hand operated megger machine of HT/LT Overhead conductor/HT/LT UG cable between Span to Span/two pole structure/four pole structure, any type insulator with complete diconnection & reconnection of jumper for checking of fault and rectification for any size any place after disconnection of AB switch/MCCB/any Breaker complete.
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool,nuts,boltsetc of the following sizes and including taking out unserviceable burnt out cable from its existing location size of cable 2 core 10 sq mm complete all as specified and directed by Engr-in-Charge :- Make : Polycab / Gloster / Finolex / Havells or equivalent
All as per item 35 above above but 2 core x 16 sqmm
All as per item 35 above above but 4 core x 16 sqmm
All as per item 35 above above but 3.5 core x 25 sqmm
All as per item 35 above above but 3.5 core x 50 sqmm
All as per item 35 above above but 3.5 core x 70 sqmm
All as per item 35 above above but 3.5 core x 120 sqmm
All as per item 35 above above but 3.5 core x 150 sqmm
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in soft/ loose soil complete all as specified and as directed Engineer-in-Charge.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as directed by Engineer-in-Charge.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as directed by Engineer-in-charge.
M&L for HDPE double wall corrugated pipes confirming to IS -14930 part-II with IP protection -68 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for cable protection all specifed and directed by Engr-in-Charge.
M&L for HDPE double wall corrugated pipes confirming to IS -14930 part-II with IP protection -68 having outer dia 120 mm and inner dia of 103 mm with necessary couplers, bends etc for cable protection all specifed and directed by Engr-in-Charge.
M & L Galvanised iron tubing 80 mm dia light grade laind in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as specified and directed.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
M&L for Attending of LT 1.1 KV Break downs, checking faults and renwal of burnt fuse wires in in 1.1kV installations with necessary tools i.e 1.1kv discharge rod, meggers,gloves etc complete all as directed by Engr-in-Charge. Note:(i) T&P shall be provided by contractor in free of cost, deemed rate shall be included in the quoted rate. (ii) One Skilled electrican and helper shall be provided while attending this job in free of cost,deemed rate shall be included in the quoted rate. (iii) proper isloation and safety guidelines shall be followed by the contractor, incase of any eventulity the contractor is fully responsible.
Maintenance of earthings of installations like cleaning of earth pits, treatment of earthing by pauring salt water, replacement of perished wire mesh, unserviceable funnel and repair works like patch works to the PCC chambers and RCC cover with cement mortar 1 : 4 all as directed.
Taking out HT/LT UG cable laid in underground/trench/cable duct/tunnel/surface and relaying/rerouting the same cable shall laid in underground/trench/cable duct/tunnel/surface as per direction of Engr-in-Charge. Note:(i)Earth work shall be measured & paid seperately under relevant items (ii) taking out &relaying of cable protection pipe shall be measured & paid separetly under relevant items
Taking out cable protection pipe laid in underground/trench/ and relaying same in underground/trench as per direction of Engr-in-Charge. Note: laying direction of cable protection pipe shall as directed by Engr-in-Charge.
S&F cable route indicator,made out of 150mm dia and 6mm thick MS plate,duly embossed with description as"MES LT 1100V UG cable" fitted to 0.5m long angle iron of size 25mm x 25mm x3mm with bolts and nuts and painting all over with two coats of aluminium paint over one coat of red oxide primer and embedded in PCC 1:3:6 type C1 block size 200mm x 200mm x 200mm and planted in cable trench all as specified and directed by Engr-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 4 sq. mm nominal cross section in service connections including necessary end terminations with suiatble lugs with crimping tool,screws etc completed all as directed by Engr-in-Charge.
M/S G S GREWAL
MAHESWARI CONSTRUCTIONS
Govinda Swamy Construction
USR Transport
M/S PANNER SELVAM
RSL Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .