Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAdmitted-Finance 13 138 SHAKTINAGAR SHUKLAGANJ UNNAO | UNNAO | UTTAR PRADESH | 209801 | L1 | Admitted-Finance | |
| 2 | L2₹10.0 L+₹2.2 L (28.7%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S SHRI KRISHNA CONTRUCTION L2 | MAA DURGA CONSTRUCTION L1 |
|---|---|---|---|---|---|
| 1.00 | Carriage of following from Site Store to work site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. (Distance 00-50Kms.) PCC Pole 8.5 mtr Long | 60 | No | 600 ₹36,000 Lowest | 650 ₹39,000 |
| 2.00 | LT XLPE Cable 3.5*150/3*240/3.5*240 sqmm | 100 | Mtr. | 100 ₹10,000 | 50 ₹5,000 Lowest |
| 3.00 | ABC bunch 3*50/3*95 sqmm | 1,500 | Mtr. | 50 ₹75,000 | 40 ₹60,000 Lowest |
| 4.00 | 100 kva TF | 5 | No. | 6,000 ₹30,000 | 3,000 ₹15,000 Lowest |
| 5.00 | LT Incoming Pannel | 7 | No. | 2,000 ₹14,000 | 1,000 ₹7,000 Lowest |
| 6.00 | 63 kva TF | 4 | No. | 6,500 ₹26,000 | 3,000 ₹12,000 Lowest |
| 7.00 | 250 kva TF | 1 | No. | 8,500 ₹8,500 | 3,500 ₹3,500 Lowest |
| 8.00 | LT XLPE Cable Single Core Cable 400 and 150 sqmm | 150 | Mtr. | 200 ₹30,000 | 50 ₹7,500 Lowest |
| 9.00 | Line material viz. Aerial bunch conductor/Weasal conductor/Dog and other line material etc. | 8 | Qtl. | 500 ₹4,000 | 250 ₹2,000 Lowest |
| 10.00 | Providing and fixing DB BOX | 14 | No. | 2,000 ₹28,000 Lowest | 2,000 ₹28,000 Lowest |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
29 Sept 2025, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC II FATEHABAD
EDC II FATEHABAD
installation of new 63/100/250 kva TF under EDD Bah
2025_DVVNL_1069215_2
TENDER NO 08/2025-26
Open Tender
Miscellaneous Works
Lump-sum
180 days
fatehabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DVVNL
₹10,000
Yes
30 Sept 2025
24 Sept 2025
29 Sept 2025
24 Sept 2025
29 Sept 2025
24 Sept 2025
Amount
Carriage of following from Site Store to work site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. (Distance 00-50Kms.) PCC Pole 8.5 mtr Long
LT XLPE Cable 3.5*150/3*240/3.5*240 sqmm
ABC bunch 3*50/3*95 sqmm
100 kva TF
LT Incoming Pannel
63 kva TF
250 kva TF
LT XLPE Cable Single Core Cable 400 and 150 sqmm
Line material viz. Aerial bunch conductor/Weasal conductor/Dog and other line material etc.
Providing and fixing DB BOX
Providing and fixing DB CLAMP
Providing and fixing LT clamp
Providing and fixing EARTHING COMPLETE
Providing and fixing CLAMP FOR T CHANNEL
Providing and fixing X ARM CLAMP
Providing and fixing F BRACKET
Providing and fixing STAY COMPLETE
Providing and fixing SUSPENTION CLAMP
Providing and fixing DEAD AND CLAMP
Providing and fixing EYE HOOK
Providing and fixing STON PAD
Providing and fixing BOLTS NUT
Providing and fixing GI WIRE FOR GUARDING
Providing and fixing GUARDING ANGLE
Providing and fixing CLAMP GUARDING
Providing and fixing MS Angle 75*75*6*2228mm with clamp
Providing and fixing Doble pole clamp
Providing and fixing Allumunium Lugs
Providing and fixing Danger Board
Providing and fixing 11 kv fuse Set
Providing and fixing tailness unit with LT Pannel box complete installation (plinth, earthing and other associates work completed by contractors)
Erection of 8.5 Mtr. long PCC pole including fixing of accessories for 11 Kv line as per RESPO Norm.
Erection of double pole on 8.5 Mtr. long STP poles including fixing of accessories for double pole as per RESPO norm.
Grouting of 8.5 Mtr PCC Pole and STP Pole, including fixing of accessories for 11/13 Kv line as per RESPO Norm.
Laying sagging stringing and binding and jumpering etc of ACSR Weasal conductor/Dog conductor as per santion Estimate in supervisioning of Engineer
Laying cable, sagging, stringing, binding and jumpering of LT XLPE Cable 3.5*150/3*240/3.5*240 sqmm sqmm complete work in all repect.
Laying cable, sagging, stringing, binding and jumpering of ABC bunch 3*95 sqmm complete work in all repect.
Laying cable, sagging, stringing, binding and jumpering of LT XLPE Cable Single Core Cable 400 and 150 sqmm complete work in all repect.
Installation of LT Pannel as per santion Estimate in supervisioning of Engineer.
making Fencing for 250 kva TF as per santioned estimate/Drawning.
Chemical Earting of 250 kva TF as per santioned estimate/Drawning.
Making Plinth for 250 kva TFas per santioned estimate/Drawning
Installation, Commisioning and Testing of 250 KVA TF complete work in all Respect.
Installation of 63 kva TF complete work in all Respect.
Installation of 100 kva TF complete work in all Respect.
Cutting of kharanja/mettalic road/concrete portion while digging pit for erection of PCC/STP poles and giving the exact shape after exicution work as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc reauired for proper completion of work.
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer
M/S SHRI KRISHNA CONTRUCTION (BID ID -5569074)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .