| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96,290Accepted-Finance | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹1.1 L+₹10,393 (10.8%)Accepted-Finance | L2 | Accepted-Finance 2nd Lowest | |
| 3 | L3₹1.1 L+₹14,195 (14.7%)Accepted-Finance | L3 | Accepted-Finance 3th Lowest | |
| 4 | L4₹1.5 L+₹49,405 (51.3%)Accepted-Finance | L4 | Accepted-Finance 4th Lowest | |
| 5 | L5₹1.5 L+₹50,270 (52.2%)Accepted-Finance | L5 | Accepted-Finance 5th Lowest |
Tender Value
₹1.5 L
Closing Date
12 Apr 2021, 10:00 amClosed
EE WSD APWD Port Blair
EE WSD APWD Port Blair
Special repair to the Bungalow AB 23 and its Servant Quarter Sw Providing IEI
2021_APWD_2838_1
02/NIT/WSD/2020-21
Open Tender
Electrical Works
Works
30 days
Port Blair
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
19 Apr 2021
6 Apr 2021
12 Apr 2021
6 Apr 2021
12 Apr 2021
6 Apr 2021
6 Apr 2021 - 12 Apr 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing the following module metal flush box (Make: Legrand, Model: Mylinc or equivalent) along with suitable modular base and cover plate(white) with frame (Make: Legrand, Model: Mylinc or equivalent) for modular switches in recess etc. as required.
a) 1 module
a) 3 modules
b) 6 modules
c) 9 modules
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 5/6 A switch
b) 15/16 A switch
c) 3 pin 5/6 A socket outlet
d) 6 pin 15/16 A socket outlet
e) Bell push
Supplying of 15 W recessed mounted LED downlight CDL/WW with minimum efficacy of 100 lm/w ( Make: Phillips , Model : Dura Slim or equivalent in technical specification).
Supplying of LED Bulk Head of wattage between 9 W to 10 W with PDC housing and IP65/ IP66 Protection, WH/NW/WW (Make:-Philips, Model : Endura or equivalent in technical specification).
Installation ,Testing, Commissioning of all LED wall bracket /ceiling fittings of all sizes and shapes , complete with all accessories including connections etc. as required.
Supplying and fixing Electronic Door Bell suitable for single phase, 230 V (Make: Philips, Model: Smart Harmony, Model No.: 913713825601 or equivalent in technical specification ).
Supplying of 5 star rated, energy saving ceiling fan of 1200 mm sweep(Opal White/Brown ) suitable for operation on 230 volts, single phase, 50 Hz, AC supply with all accessories as required (Make: Crompton, Model: High Speed Plus-5 star or equivalent in technical specification).
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & fixing 25 A Modular AC Box (Single Phase ) with 25 A SP MCB, Plastic Enclosure & Top (ISI marked) including connections etc. as required ( Make : Anchor, Model : ROMA, Code : 98484 or equivalent in technical specification).
Providing and fixing 100A capacity , 415 Vac, 50 Hz,TP&N Switch Fuse Unit with Rewirable Porcelein Fuse Units, ISI marked (Make: Havells, Cat. No.: IHBRTE4100 or equivalent in technical specification) including drilling holes , making connections, etc. as required.
Providing and fixing 100A, 8 way , Busbar Chamber (Make: Havells, Cat. No.: IHBC010008 or equivalent in technical specification) including drilling holes , making connections, etc. as required.
Providing and fixing 100A capacity , 415 Vac, 50 Hz,Onload Changeover Switch in sheet enclosure, ISI marked (Make: Havells, Cat. No.: IHBFFE0100 or equivalent in technical specification) including drilling holes , making connections, etc. as required.
M/s Sai Electrical Works
JOY GURU ENTERPRISES
NAVJEEVAN ENTERPRISES
DILIP RAJ
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .