Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 CrAdmitted-Finance | ₹8.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.6 Cr+₹79.9 L (9.08%)Admitted-Finance | ₹9.6 Cr+₹79.9 L (9.08%) | L2 | Admitted-Finance |
| 3 | L3₹12.2 Cr+₹3.4 Cr (39.0%)Admitted-Finance B 604 VASUNDHRA APARTMENTS PLOT NO 16 SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹12.2 Cr+₹3.4 Cr (39.0%) | L3 | Admitted-Finance |
| 4 | L4₹13.8 Cr+₹5.0 Cr (57.0%)Admitted-Finance | ₹13.8 Cr+₹5.0 Cr (57.0%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | B D Raizada Projects Pvt Ltd L4 | Global Enterprises L1 | AMIT ASSOCIATES L2 | Pooja Singla Builders And Engineers Pvt Ltd L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | SUMMER APPLIANCES
Supply and install storage type water cooler , fully stainless steel electric driven (single phase) having approx storage capacity of 40 litres and nominal cooling capacity of 40 litres per hour complete | 10 | Each | 59,900 ₹5,99,000 | 40,000 ₹4,00,000 Lowest | 55,000 ₹5,50,000 | 45,000 ₹4,50,000 |
| 2.00 | S&F voltage stabilizer for automatic operation single phase naturaly air cooled indoor type wall mounted and designed for input variation between 170 V to 250 V with output voltage stablizer at 230 V with accuracy of +/- 2.5% of capacity 3 KVA.(For water Coolers) complete | 10 | Each | 5,900 ₹59,000 Lowest | 6,000 ₹60,000 | 6,500 ₹65,000 | 10,000 ₹1,00,000 |
| 3.00 | INTERNAL ELECTRIC SUPPLY
S&F VTPN DB's 415 Volts, IP-43, with MCCB 250 AMP, 4 pole as incommer, 6 way with 200 Amps rated copper bus bar double door type complete all as directed | 1 | Each | 44,900 ₹44,900 | 9,600 ₹9,600 Lowest | 10,500 ₹10,500 | 15,000 ₹15,000 |
| 4.00 | S&F recessed mounted LED 2x2 fitting neutral white enabled by advanced LED light, it lends into ceiling panel and maintains uniform luminance across aperture to enhance visual comfort and including connecting up electric connection from ceiling rose to light fittings complete all as specified and as directed. | 52 | Each | 5,900 ₹3,06,800 | 1,800 ₹93,600 Lowest | 2,150 ₹1,11,800 | 11,000 ₹5,72,000 |
| 5.00 | S&F concealed conduit 20 mm for LAN /internet and telephone wiring complete all as specified and directed. | 5,200 | RM | 79 ₹4,10,800 | 100 ₹5,20,000 | 125 ₹6,50,000 | 50 ₹2,60,000 Lowest |
| 6.00 | S&F dual face plate with gang box complete all as specified and as directed | 699 | Each | 149 ₹1,04,151 Lowest | 220 ₹1,53,780 | 250 ₹1,74,750 | 325 ₹2,27,175 |
| 7.00 | S&F cat 6 for date and voice complete all as specified and as directed | 279 | Each | 229 ₹63,891 | 42 ₹11,718 | 55 ₹15,345 | 25 ₹6,975 Lowest |
| 8.00 | M&L for IP 66 powder coated pressure die cast aluminum compact high power LED bldg security light with heat resistant toughened glass of rating 25 W inclprovn of 3 core PVC insulated sheathed, stranded copper conductor cable/flexible chord of size 2.5 sqmm for electrical \connection from ceiling rose to security/street light fitting complete all as specified and as directed. | 6 | Each | 4,900 ₹29,400 | 2,700 ₹16,200 Lowest | 3,000 ₹18,000 | 10,000 ₹60,000 |
| 9.00 | S&F single pole and neutral enclose with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps including cutting chases and concealing with same enclose in wall and making well including finishing of surfaces complete all as directed. | 7 | Each | 2,490 ₹17,430 | 660 ₹4,620 Lowest | 680 ₹4,760 | 1,500 ₹10,500 |
| 10.00 | S&F AC modular box with modular back plate and top cover suitable for and including modular socket 3 pin 20W and one modular MCB 25 Amp complete all as specified and directed. | 72 | Each | 2,290 ₹1,64,880 | 660 ₹47,520 Lowest | 690 ₹49,680 | 1,500 ₹1,08,000 |
Tender Value
Refer Docs
EMD Value
₹7.1 L
Closing Date
3 Dec 2022, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer Delhi Zone, Delhi Cantt-10
CONSTRUCTION OF OFFICE ACCN FOR SIX OFFICERS OF AAO (P), LAO (A), LAO(B), LAO(C), LAO 505 AND SERVICE CENTER FOR DELHI AREA AT DELHI CANTT
2022_MES_519183_1
CA NO CEDZ/TOKEN-27 of 2022
Open Tender
Civil Works
Lump-sum
540 days
Delhi Cantt
MES contractor enlisted in MES under class S cat a i having deposited Standing Security of Rs 1100000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹3,000
GE (P) East Delhi Cantt
₹7.1 L
Yes
6 Dec 2022
21 Apr 2022
5 Dec 2022
21 Apr 2022
3 Dec 2022
16 Nov 2022
Amount
SUMMER APPLIANCES Supply and install storage type water cooler , fully stainless steel electric driven (single phase) having approx storage capacity of 40 litres and nominal cooling capacity of 40 litres per hour complete
S&F voltage stabilizer for automatic operation single phase naturaly air cooled indoor type wall mounted and designed for input variation between 170 V to 250 V with output voltage stablizer at 230 V with accuracy of +/- 2.5% of capacity 3 KVA.(For water Coolers) complete
INTERNAL ELECTRIC SUPPLY S&F VTPN DB's 415 Volts, IP-43, with MCCB 250 AMP, 4 pole as incommer, 6 way with 200 Amps rated copper bus bar double door type complete all as directed
S&F recessed mounted LED 2x2 fitting neutral white enabled by advanced LED light, it lends into ceiling panel and maintains uniform luminance across aperture to enhance visual comfort and including connecting up electric connection from ceiling rose to light fittings complete all as specified and as directed.
S&F concealed conduit 20 mm for LAN /internet and telephone wiring complete all as specified and directed.
S&F dual face plate with gang box complete all as specified and as directed
S&F cat 6 for date and voice complete all as specified and as directed
M&L for IP 66 powder coated pressure die cast aluminum compact high power LED bldg security light with heat resistant toughened glass of rating 25 W inclprovn of 3 core PVC insulated sheathed, stranded copper conductor cable/flexible chord of size 2.5 sqmm for electrical \connection from ceiling rose to security/street light fitting complete all as specified and as directed.
S&F single pole and neutral enclose with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps including cutting chases and concealing with same enclose in wall and making well including finishing of surfaces complete all as directed.
S&F AC modular box with modular back plate and top cover suitable for and including modular socket 3 pin 20W and one modular MCB 25 Amp complete all as specified and directed.
S&F of RJ 112 Tej jack with shutter modular type complete all as specified and directed.
S&F of modular socket type for INTERNET complete all as specified and directed.
RAIN WATER HARVASTING SYSTEM M&L for drilling 250 mm dia bore hole by DTH cum Rotary at any depth below the GL in any kind of soil / rock up to 50 M depth incl disposal of surplus spoil to a distance not exc 50 m away all as specified and directed.
S & F self perforated unplasticised PVC pipes 200 mm dia of pressure rating 10 kg/ sqcm fixed complete to walls or in floors complete all as specified.
EXTERNAL WATER SUPPLY Supply , laying jointing testing ductile iron pipe with spigot socketed ends class K-9 conforming to IS 8329 with inside cement mortar lining laid in trenches of 100mm bore size complete including joints and jointing materials suitable for DI pipes all as specified and directed
Supply , laying jointing testing ductile iron pipe with spigot socketed ends class K-9 conforming to IS 8329 with inside cement mortar lining laid in trenches of 80mm bore size all as specified and directed
Cutting existing DI pipe line 150 mm dia, screwing and inserting ferrule for making new branch connection GI tube of 80 mm dia including necessary fittings complete all done in positing without taking down complete all as specified and as directed
ARBORICULTURE Supply only fine sand at site including royalty and carriage for preparing compost at site (sand shall be brought at site and stacked for measurement before incorporating in the work) complete all as specified.
Supply only sweet / good earth at site including royalty and carriage for preparing compost for pits/required for planting trees and shrubs etc (sweet/good earth free from objectionable extraneous matter, toxic material and termites shall be brought at site and stacked for measurement before incorporating in the work. 20% of computed volume shall be reduced for loose stacking, complete all as specified.
Supply only manure at site including royality and carriage for preparing compost at site. Manure shall be brought at site and stacked for measurement before incorporating in the work. 8% computed volume shall be reduced for loose stacking completely all as specified.
Preparing compost pits of size 0.60x0.60x0.60 by excavation in ordinary soil carrying out antitermite treatment, planting trees & refilling of the pit with compost (manure, sand & sweet earth mixed in ratio (1:1:4) breaking moulds, ramming and flooding with water filling with more compost if necessary and fine dressing including removal of rubbish unserviceable materials & surplus soil to a distance n.exc 100 m. ATT shall be in form of 200 gms neem cake mixed with every cum of compost followed by Dursban or equivalent applied at 2 ml per litre in the first watering of 20 litres per pit, complete all as specified. Note :- (i) The rate for excavation and getting out of soil shall be deemed to be included in the unit rate of this item. (ii) The rate for mixing only earth, manure and sand is deemed to be included in the unit rate of this item supply of sweet earth, manure and sand shall be paid under respective item of this schedule.
Preparing compost pits of size 0.90x0.90x0.90 by excavation in ordinary soil, applying antermite treatment, planting the tree & refilling of pit with compoost (manure, sand & sweet earth mixed in ratio 1:1:4) breaking mould, ramming and flooding with water with more compost if necessary and fine dressing including removal of rubbish unserviceable materials and surplus soil to a distance n.exc 100m. ATT shall be in form of 200 gms neem cake mixed with every cum of compost followed by Dursban or equivalent applied at 2 ml Per litre in the first watering of 20 litrs per pit. Note:- 1. The rate for excavation and getting out of soil shall be deemed to be included in the unit rate of this item. 2. The rate for mixing only earth, manure and sand, deemed to be included in the unit rate of this item supply of sweet earth, manure and sand shall paid under respective item of this schedule.
Supply and planting following trees in location where shown on drawing and described in schedule 'A' and specifications/directed by Engr-in-Charge, girth 80mm to 100mm minimum (measured at 150mm top of roots) and complete provided necessary pots whereas required as per plants and height as shown under.
(a) Bottle palm `4' height
(b) Cycus palm 4' height
(c) Kochnar 4' height
(d) Champa 4' height
(e) Jacarnda mimo safelia 4' height
(f) Deloniox Regia (Gulmohar) 4' height
(g) Cassia fistala (Amaltas) 4' height
(h) Chinese Palm 4' height
(j) Bougenvillia varigelta 4' height
(k) Ashoka 4' height
Supply and planting shrubs i.e. Aclypha 2', Calliandraz', Crotons 3', Hamcha, Jasminum capensis `Hibisew, Ticoma, Golden Dorangta, Red Hedge and complete provided necessary pots whereas required as per plants as directed by Engr-in-Charge.
(i) Ploughing of whole site in sofl/ordinary soil upto the depth of 20 cm and removing all the unwanted material such as stones, weeds, tree root etc which are not suitable for healthy growth of grass .
(ii) Dressing and leveling the soil to a required gradient and slope on completion of work mentioned in Note (a) above after loosening the soil.
(iii) Mixing of fertilizers and manure evenly by manually as under and as directed .
Manure:- Old cow dung or Okhla sludge at the rate of 2.25 cuts foot for 10 Sqm.
Fertilisers :-
(i) Neem Kholi at the rate of 2 kg for 10 Sqm.
(ii) Benemeal at the rate of 1 Kg for 10 Sqm.
(iii) D.A (16.42) at the rate of 0.15 kg for 10 Sqm.
(iv) BHC dust 10% or lindance dust at the rate of 0.15 kg for 10 Sqm.
(d) Fine dressing a top soil after mixing the manure and fertilizer to requisite slope.
(e) Watering the area for fine dressing of soil after one week till the soil get water upto.
(f) Fine dressing of surfaces of top soil to require slope and gradient towards the manholes.
(g) Plantation of grass @ 10 Cm do both way by dibbling root method.
EXTERNAL ELECTRIC SUPPLY Supply, installing, testing and commissioning outdoor type step down transformer, 11 KV/433 volts (at no load) AC 3 Phase 50 Hz 500 KVA capacity, core copper wound, oil immersed, naturally cooled, ONAN with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV side) and having tapping at +5% to -10% in Step of 2.5% on HV site to be changed by means of hand operated off load tap changer gear.The transformer shall be confirming to IS-1180 (not below level -II ) with standard fittings and shall comprise etc. complete all as specified and directed of the following :-
(a) One cable box for HT connection, three Nos procelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers
(b) One cable box on LT side (secondary side) consisting of connection through Bus Bar Trunking/cable termination.
(c) Oil conservatror with filter type drain valve and oil level guage
(d) De-hydrating breather with first fill fo dehydrating agent (Sillica gel).
(e) Explosive vent, Thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs, oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain soild cast steel detachable rollers.
(f) Oil temparature meter and winding temparature meter having range 0-120 degree celsius.
(g) Two earthing terminals on tank cover to facilitate fixing for earth stirp earthing of body.
(h) Rating plate and terminal marking plate.
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(k) First filling of new and unused transformer oil, filtered and tested upto 60 KV dielectric strength at 2.5 mm air gap between testing electrodes.
(l) Lifting lugs
(m) Pressure release valve.
(n) Foundation as per manufacturers recommendations.
Supply & lay of LT UG Cable of 300 sqmm 1 core size (2 Run) including connection with lugs, cable gland etc from Transformer to Main LT panel out door type 1100 volts grade XLPE insulated PVC bedded galvanised steel strip armoured electric power cable with stranded aluminium conductor complete all as specified and as directed
Supply, installation, Testing and commissioning of Automatic Power Factor Correction (APFC) capacitor panel having aggregate capacity 200 KVAR in 5 stage with micro processor based control , factory made oudoor type, platform mounted,suitable for 440 volts 3 phase 4 wire, 50 Hz AC supply system, having duly insulated copper bus bars, dust and vermin proof, IP 57 class protection and made of 1.6 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Navtal) lock with 2 keys, internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 sqmm complete all as specified and directed and comprising of followings :-
incoming:-
(i) MCCB 4 pole 300 Amp 25 kA 415V.
Outgoing :-
(i) Power factor corrector relay 10 stage Microprocessor based, modular type , intelligent APFC relay capable of having self adjustment to any capacitor value suitable to maintain power factor between 0.85 to 0.95 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps- 01 No
(ii) Power Capacitor MPP-H type of under mentioned capacity :-
(a) 50 KVAR - 2 No
(b) 25 KVAR - 2 No
(c) 15 KVAR - 2 No
(d) 5 KVAR -04 No
(iii) Power contactor 40 Amp - 02 Nos
(iv) Power contactor 30 Amp - 02 Nos
(v) Power contactor 20 Amp - 06 Nos
(vi) MCB TP 63 Amp - 02 Nos
(vii) MCB TP 40 Amp - 02 Nos
(vii) MCB TP 32 Amp - 02 Nos
(viii) MCB TP 20 Amp - 04 Nos
(ix) Protection Fuse 32 Amp HRC type
(xi) ON – OFF Push Button
(xii) Aux Contacts 5 No + 5 NC of L&T or equvalent in Crompton Greaves /Siemens/ABB - 7 set
(xiv) One Amp Meter 0-600 Amps with CT's & one Volt meter 0-500 V
(xv) Indicating light for capacitor ON / OFF position
Note : The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation.
Supply, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type LT Panel outdoor type of appropriate size and fabricated from 3.5 mm thick CRCA sheet steel with necessary MS angle iron frame work(50X50X6mm), weather proof, vermin proof, suitable rating copper bus bar chamber for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labeling , cable alley suitable for termination of cables including supply and fixing of following switchgear and accessories in the panel complete as required size conforming specification as per IS 5039. The panel should be CPRI approved and having IP 57 ingress protection including necessary foundation for mounting all as specified and directed by Enginer in charge. (Main LT panel outdoor)
Incoming
(i) ACB 4 pole 1000 Amp 50 KA 415V (Main Incomming) - 01 Nos
Outgoing :-
(i) MCCB 4 pole 415 V breaking cap 35 KA , current rating 150 Amps. - 04 Nos(Each Floor Upto 3rd Floor VTPN)
(i) MCCB 4 pole 415 V breaking cap 35 KA , current rating 100 Amps. - 02Nos(4 th Floor VTPN,Fire Fightning)
(ii) MCCB 4 pole 25 Amp 16 kA 415V - 01 Nos(Lift )
(v) MCCB 4 pole 300Amp 25 kA 415V 01 Nos(APFC Panel)
(vi) MCCB 4 pole 16Amp 16 kA 415V - 02 Nos(Street Light)
(vii) Space for MCCB 4 pole 100Amp 25 kA 415V( Blank)
(viii) Digital Voltmeter(0-500V) -01 Nos
(ix) Digital Ameter (0-1000A) - 01 Nos,
(x) LED indication lamp -01 (R Y B, set of three)
(xiii) CT: 1000/5A, 5VA CL.1-3 Nos
(xiv) Busbar: 1500Amps, System Voltage: 415V, 50 Hz, 4W +E
Boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine suitable for GI tube of 100mm dia & suitable for 0.4 mpa working pressure complete all as specified and as directed by Engineer In Charge.
S&F connecting of testing and commissioning of LED street light fittings 60 W IP54withcomplete accessories fixed inexisting poles and bracketes and connecting from kiosk box bymeans of 3 runs of 2.5 Sqmm PVC insulated but unsheathed FRLS copper conductor cable complete allas specified and directed.
Material and labour for platform for the transformer of size 3.0x2.5x1.5 m with PCC 1:4:8 type D-2 with 40 mmm graded crushed stone, 15 cm thick I foundation, brick work in CM 1:6 with sub class 'B'old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 type C-1 using 20 mm graded crused stone aggregate on top and grouting of MS channels for transformer and fabrication of chain link fencing for transfer for size 5.5x5.5x2.1 m height with angle iron gate of size 2.0x2.1 meter with proper locking arrangement including lock & key wire mesh 4 mm dia size 150x100 mm, angle iron post of size 65x65x6 mm and wire mesh fixed with post with MS flat 40x5 mm and nuts and washer MS gate fabricated by 40x40x5 mm angle size duty painted with synthetic enamel paint two coat over a coat of red oxide primer. All post should embedded in PCC 1:2:4 of size including necessary excavation work complete all as specifed and directed.
M&L for LT kiosk box for security/street lights weather proof made out of PVC fire retardant, non fusing, shock & dust proof, one piece moulded SMC base and SMC cover with hinged door, pole mounting type comprising of aluminum busbar TPN of 63 Amps with MCB, SP 15 Amp of size 300x200x100mm fixed on pole MS clamps 20x3mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of danger sign of size not less than 10cmsx7.5cms with letter and conventional skull and bones in signal red colour on front face of kiosk box complete all as specified and directed
S&F connecting testing and commission post top lentern luminaries of 28 watt LED lamp and complete with strandard fitting and also including provisono f sixing on 40 mm bore light grade DI pipe fixed on gate post and connecting with 3 run of 1.5 sqmm PVC insulated, unsheathed copper conductor cable including sheet metal enclosure DB two way with MCB SP 2.5 Amps rating luminaries complete allas specified and directed.
EXTERNAL WATER SUPPLY Supplying, laying, jointing, testing and commmisioning of DI Pipe size 100 mm bore as per IS 8329-2000, class K-9 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and as directed
LIFT supply, installation, testing and commsiioning of 544 Kg 08 passengers having rated speed 1.5 m/s with single speed motor conforming to IS-15785, IS-14665 and suitable for 3 Ph, 415V, 50 Hz AC supply, suitable to serve Ground floor+ 04 upper floors withAC variable voltage and variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operationwith/without attendant, center opening doors / 2P TSPD withdoor drive (electric moto driven mechanism), sliding stainless steel door, automatic rescue device (ARD) system, 3 D infrared sensor in full height of door & built in announcing system without handset (04 Nos, one each i car, machine room & near ground floor landing door) complete all as specified and directed
Make : OTIS/Schnidler, Kone, Mtisubishi
The lift shall conform to the following technical specifications.
(i) Type of lift : Passenger lift (08 passangers)
(ii) Load capacity : 544 Kg
(iii) Speed : 1.5 m/s with single speed motor
(iv) Power supply :3-Ph, 4 wire, 415 V, 50 Hz AC
(v) Type of drive : AC Variable voltage & Variable Frequency
(vi) Type of Mahine : Gearless
(vii) Car size L Not less than 1.60 m x 1.35m
(viii) Car & landing door at all flors : 2 P TSPD/ center opening door withVVVF door drive, opening size not less than900mm x 2000mm, sliding type, center opening,fabricated bystainless steel not less thn 16 gauge having hairline finish (N-304)
(ix) Car Enclosure : Manufactured with stainless steel frame not less than16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated o commercial supply and one LED light fitting operated on battery with invertor as emergency light,complete internal ventilation system providedwith concealed axial/corss flow fan with auto cut-off systemand stainelss steel grill/wire mesh for protection.
(x) Provision of standard thickness 40mm diameter stainless steel hand rail all around inside the car cabin
(xi) Terminal Buffers : Metal specialspring/PU/Oil buffers as per manufacturere's recommendation. The buffing stroke shall bot be less than 200mm.
(xii) Door Opening (inside) : Protected by 2P TSPD stainless steel door having harline finish with opening not less than 800 mm x 2000mm.
(xiii) Car & counter weight Guide : As per OEM recommendations
(xiv) Flooring : As per OEM recommendations
(xv) Signals :
(a) Combines luninous hall buttons with LED/LCD/TFT hall position indicators at all floors
(b) LED/LCD/TFT car positionindicator panel of stainless steel
(c) Car operating pnel of stainless steel with luminous buttons in car
(d) Car direction indicator in car & landing
(e) Battery operated alarm bell & ememergency light (rechargable) alongwith suitable maintenance free battery. (The system shall be separate from ARD Batteries)
(f) Overload warning feature in car cabin (display/announcing type boty)
(g) One fireman's switch to be installed at ground floor near landing door.
(h) All signal fixtures & car operating panel on hariline stainless steel face plate with hariline finish
(j) Infrared door sensor safety edge of door for entire height.
(k) Built in announcing system without handset 2 Nos, one for lift car & ground floor landing door and one announcing system with handset in machine room
(l) The interior of the car shall be provided with as device that audibly announce the floor positionof lift car has reached and announce that car entrance/exit door is open or closed.
(xvi) Stop & Opening : 05-05 with all opening being on the same side
(xvii) Safety Device :
(a) Automatic Rescue Device (ARD)/ automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charge input be connected with converter of regenerative drive.
(b) The ARD actuation time shall be less than on second after filure of powe supply and when ARD is opertive the car shall stop at the nearest floor and then door shll open.
(xviii) Machine Room : Located above the hoist way, details as per building drawings
(ixx) Hoist Way : Construciton details as per building drawings
(xx) Civil work : Necessary civil work viz. maiking good disturbed sufaces, modification to landing space to suit car size, necessary foundation to machine(s) etc.
(xxi) One number of wall mounted type telephone instrument installed inside of car cabin alongwith fixing arrangement and telephone cable of suitable size from car cabin to mahine room run alongwith travelling cable. The telephone instrument shall be connected in the telephone DB installed in the mahince room.
(xxii) Mirror of suitbable size to be provided on the lift car wall opposite to main door above SS railing.
Fabrication,Supplying & installation, testing and commissioning of Electrical motor control panel for Lift of cubical construction double door panel wall mounted indoor type fabricated 2mm thick CRCA sheet compartmentalized with hinged lockable doors, dust and vermin proof, powder coated, single core PVC insulated FRLS copper conductor cables, having suitable mountings for switchgears and accessories and internal control & power wiring with suitable rating PVC insulated FRLS copper conductor, earth terminals numbering etc suitable for operation on 415V 3 phase 50 Hz AC supply with enclosure protection class IP 55 with 40 Amp rating Al bus bar etc complete as required
(a) Incoming :-
MCCB 4 pole 25 Amp 25 kA 415V(incomer for Lift ) - 01 Nos
(b) outgoing :-
(i) MCCB 4 pole 25 Amp 25 kA 415V(iOutgoing for Lift ) - 02 Nos
(ii) Digital type Volt meter 0-500 volt - 01 Set
(iii) Digital type Amp meter with CT's - 01 No
(iv) Indicating Lamps : 01 set
DG SET Supply, installing, commissioning and testing complete of manufacturer of OEM (Original Eqpt Manufacture) manufactured and tested static Silent Diesel Engine driven generating set capable of delivering 62.5 KVA, 415 volts (AC 3 Phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternatore and mounted on Dunlop metallastik foundation pads on a common base frame and threafter intalled in the CPCB approved acoustic enclosure (the complete set conforming to and test certified as per CPCB norms and as specified) all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete and shall comprise of the following :-
(a) ENGINE (PRIME MOVER). Diesel Engine 1500 RPM of suitbale HP as recommended by manufacturer but not less than 80.1 BHP (at NTP) water cooled, Turbocharged aircooled, 1x 88 AH 12 Volts electric battery start, complete with fly wheel and all standard fittings/fixtures as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp & pressure gauge, water temp guage and frequency meter (digital type) including safety shutdown contents) and also including self starter, dynamo, fuel tank etc and conforming to I.S. 10002, ISO 3046, BS-5514. The engine shall give electrical out put of 62.5 KVA at 0.8 PF.
(b) ALTERNATOR. AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to BS 2613/IS 4722, 3 Phase, 415 volts, 50 Hz, 4 wire system output 62.5 KVA PF 0.8 1500 RPM insulation class `H' enclosure IP 23/TEFC complete with AVR with + 1% voltage regulation directly coupled to and match the above engine and capable for over load of 10% for one hr in 12 hr operation.
( c) CONTROL PANEL (AMF PANEL) The control panel to match with the requirment of DG set and shall be manufactred with 14/16 gauge CRCA sheet and is powder coated for a weather proof and long lasting finish . The control panel consist of following parts as per manufacred norms: (i) PCC- key switch/ Autostart Generator set controller. (ii) Multifunction meter displaying the parameter as voltage current, frequency water oil pressure KVA,KW (iii) Contractors with HRC fuse of suitable rating,current transformers, AMF logic Battery Charger< Aluminium Bus bar of suitable capacity indicating lamps. (iv) Standard foundation as per manufactrers specification anti vibration foundation pad of approved make & suitable capacity.
(d) Dunlop Metallastick anti-vibration pads for mounting engine - alternator assembly on the base frame/plate
(e) BASE FRAME. Made out of structural steel as per manufactur's recommended design/specications.
(f) ACOUSTIC ENCLOSURE. Provn of an integral type approved/certified acoustic enclosure as per CPCB norms for the DG sets restricted the noise level to 75 db at one meter along and temp rise within canopy shall not exceed 5° to 7° Celsius. It shall be made of 16 SWG CRCA MS sheet with powder coated finish on outside and provided with non igniting fire retardant foam as accustic material. There shall be four hinged doors out of which one shall be with a glass window. The base frame shall be ISM section. It shall also include the following :-
(i) Silence absorption type, non-resistance, residential and exhaust pipe covered with asbestos rope lagging extending to about 2 mtrs outside the acoustic enclosures.
(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and flourescent lamp fittings.
(iii) Fuel tank of 8 hrs capacity but not less than 150 ltrs made of 14 SWG CRCA MS sheet duly powder coated and provided with float, gauge and fuel float switch.
(g) Battery 1 Nos 12 V x 88 AH DC charged/sealed maint free of suitable cap all inclusive of engine/alternator protective foundation with LCD display.
(h) Control panel
(j) Foundation of DG set as per manufactuer recommendation & drawings.
(k) CATALOGUES. Operation and Maintenance manual, spare parts list, overhauling manual - 03 sets
(i) All outgoing feeders shall be connected by cable through suitable size gland plate/glands.
(ii) The various feeders hall be indicated by 50 mm size PVC reflective tape letter
FIRE FIGHTING (E/M) M & L single sided version 3W single side display with man running right LED signane with built in battery backup for 2 hrs, luminaire type BESL03 LED SSD WBB Green MR Make-Bajaj or equivalent
M & L single sided version 3W single side display with man running left LED signane with built in battery backup for 2 hrs, luminaire type BESL03 LED SSD WBB Green MR Make-Bajaj or equivalent
M & L single sided version 3W single side display for staircase signage upwards (with built in battery backup for 2 hrs), Green Make-Bajaj or equivalent
M & L single sided version 3W single side display for staircase signage downupwards (with built in battery backup for 2 hrs), Green Make-Bajaj or equivalent
Supply & install testing and commissioning of fire fighting panel suitable for 415 volts, 3 phase, 4wire, 50 Hz power distribution system. The panel should be free standing floor mounting compartmentalized design of 2mm thick CRCA sheet steel enclosure indoor type dust & vermin proof conforming to IP 52, painting, earthing numbering, danger plate as per specification and drawing , flush front with 300 amps throughout the length of the panel. The incoming and outgoing feeder breakers fuses, indicating lamps etc shall be accommodated in modular multitier arrangement. The paint specification adequate size cable alley shall be provided all around the panel and in back for each cable bending and termination. The panel shall be fabricated by CPRI/Fire authority approved manufacturer. The outgoing feeder inside the panel shall be connected through cooper bus bar, bus bar shall be provided with heat shrinkable sleeves and shall be colour coded. The panels shall be suitable for cable entry from top. The panel shall be fabricated after the approval of fabrication drawings in wiring from Engineer-in-Charge. The rated also include installation of the panel on floor/wall including civil work involved for errection. The panel shall consist of the following :-
INCOMING :-
(a) Moulded case circuit breaker, 4 pole with breaking capacity 36 KA, rating 250 amp – 01 No
(d) Indicating lamps (R Y B) including fuses (03 Nos) 2 Amps capacity – 01No (set of three)
OUTGOING :- (Main Pump)
(a) Moulded case circuit breaker, 3 pole with breaking capacity 35 KA, 415 Voltm rating 200 amp – 02 Nos
(b) Contactor 80 mp – 03 Nos
(c) 45-75 Amp over load relay – 01 No
(d) SSP (VSPD1) – 01 No
(f) Push button with eliment (stop/Start) – 02 Nos
(g) Indicating Lamp (ON/OFF/TRIP) – 03 Nos
(h) 6A SP MCB, 10 KA – 01 No
(j) Terminal block – 06 Nos
(k) Star-Delta Timer (0-30Sec) – 01 Nos
Jockey Pump
(a) Moulded case circuit breaker, 3 pole with breaking capacity 25 KA, 415 Volt, rating 63 Amps – 02 Nos
(b) Contactor 32 Amps – 01 No
(c) 14-23 Amp over load relay – 01 No
(d) SSP (VSPD1) – 01 No
(f) Push button with eliment (stop/Start) – 02 Nos
(g) Indicating Lamp (ON/OFF/TRIP) – 03 Nos
(h) 6A SP MCB, 10 KA – 01 No
(j) Terminal block – 06 Nos
12 V Diesel Engine Pump
(a) MCB DP 16 Amps, 10 KA-02 Nos
(b) 12V DC Automatic Bty Charger 10A-01 No
(c) DC Relay – 05 Nos
(e) 12V DC ESR – 01 No
(f) Terminal block – 01 set
(g) Fault indicator – 01 Set
(h) Push button with eliment (START/STOP/MUTE/RESET) – 0s34 Nos
(j) DC Volt Meter (0-30V) – 01 No
(k) DC Ammeter (0-30A)- 01 No
(l) 12 V DC Hooter – 01 No
Supply, installation, testing and commissioning of electric terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50 Hz supply system. The panel should be suitable for automatic operation for the fire pump as per the specified parameter. The panel shall be completely compartmentalized and complete with relays, contractors, starters, aluminum bus bar, designation lables as per requirement, continuous earth bar, panel separators, protective screens, cable clamping supports system panel lamps, top/bottom cable gland plate for incoming and outgoing cable entries complete all as specified and directed
S & F Dry chemical type Fire Extinguisher ISI marked in 6.0 Kg Cap confirming to IS: 15683-2006 duly filled with ISI marked powder confirming to IS : 15683-2006 duly filled with ISI marked powder confirming to IS: 14609 with squeeze grip release valve, discharge pipe, pressure gauge locking arrangement,operation manual and wall bracket.
S & F CO2 type Fire Extinguisher ISI marked in 4.5 Kg Cap confirming to IS: 15683-2006 complete with wheel type control valve, locking arrangement,operation manual and wall bracket.
S&F clean agent fire extiguisher ISImarkedin 4 kg cap confirming t IS:15683 complete with control valve, locking arrangement, operation manual complete all as specified and directed
S&F wheeled dry powder Powder extinguisher ISImarkedin 25 Kg cap confirming to IS:15683 complete with wheel type contorl valve,locking arrangement, operation manual and wall bracket
Supply, installation, testing & commissioning of 2 way communication Fire Fighter's Telephone jack complete as required as per technival specification.
Supply, installation, testing & commissioning of 2 way communication Fire Fighter's Handset jack complete as required as per technival specification.
LIGHTENING PROTECTION Supply and fixing of specially designed lightning current High Voltage Sheilded Cable (HVSC) 7 layer cable consisting of Inner Core, Concentric Conductor (copper), Inner binding tape, Insulation material, Metallic screen, Outer binding tape, Outer sheath with the nominal cross sectional area of 50 sq.mm & overall diameter of 37mm with the insulation resistance of 1830 M Ohm-km, tested for 200 KV as per termination & connected to the earth pit with the lower terminal kit to safely route the lightning current.
Providing, laying, testing and commissioning of earthing pits with inspection chamber using required qty of ISOGEL (Chemical to enhance earth bonding improving compound) using copper earth electrod of tube/rod of 3 Mtrs Length includind cover etc as required (as per sketch in technical specifications)( 10 year maintanance free)
Supply, installation, testing and commissioning of Advance Lightning Protection complete with the lightning Air Terminal- Configured as a Spheroid consisting and comprising of separate electrically isolated 4 panels surrounding an Earthed Central Finial. The Insulation material used to electrically isolate the panels shall comprise of a base polymer which provides high Ozone & UV resistance with di-electric strenght of 24-38 KV/ mm tested as per NFC 17-102 & IEC 60-1: 1989. The CSE terminal shall not contain any electronic circuits or any moving parts for its operation. The CSE terminal shall be tested & certified by CPRI (Central Power Research Institute, Govt of India) for the impluse current of 45 KA (8/ 20 micro sec) with 5 positive & 5 negative impulse. The CSE terminal shall be approved by DGMS (Director General of a protection radius of 79m with the Level 1 (High) protection & to be mounted as per design and shall be provided with following accessories/ fitments. • Upper & Lower Termination Kit • FRP Mast (2m) • Inline coupling • Guy wire kit 4m • GI Mast (3m) Protection radius 45 m with Level 1/ High protection)
Description of Work / Item(s)
Amount
Total amount of Revised Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of Sch 'A' Section II (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of Revised Sch 'A' Section III (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of Revised Sch 'A' Section V (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Road, Path & Culvert) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (Compound wall, fencing & Gate) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of Sch 'A' Section VIII (Rain Water Harvesting System) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of Sch 'A' Section IX (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of REVSIED Sch 'A' Section X (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
Total amount of REVISED Sch 'A' Section XI (Fire Fighting E/M WORKS) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XI)
Total amount of Sch 'A' Section XII (DG Set) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XII)
Total amount of Sch 'A' Section XIII (Lift) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIII)
Total amount of Sch 'A' Section XIV (AIR CONDIGTIONING) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIV)
Total amount of Sch 'A' Section XV (Demolition & Dismantling) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XV)
Total amount of Sch 'A' REVSIED Section XVI (Excavation, Earth work & Site Clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XVI)
Total amount of Sch 'A' Section XVII (Hard Standing (Open & Covered) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XVII)
B D Raizada Projects Pvt Ltd
AMIT ASSOCIATES
Pooja Singla Builders And Engineers Pvt Ltd
AMIT ASSOCIATES
Pooja Singla Builders And Engineers Pvt Ltd
B D Raizada Projects Pvt Ltd
Bidder Name
AMIT ASSOCIATES
Pooja Singla Builders And Engineers Pvt Ltd
Global Enterprises
B D Raizada Projects Pvt Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .