Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.1 LAccepted-AOC VPO MUNDHAL KHURD TEHSIL DISTT BHIWANI PIN 127041 HARYANA | BHIWANI | BHIWANI | HARYANA | 127041 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹4.6 L+₹47,130 (11.5%)Rejected-AOC MAIN ROAD VPO BALDHAN KALAN DISTRICT REWARI 123411 | REWARI | REWARI | HARYANA | 123411 | 2 | Rejected-AOC Higher Rate |
Tender Value
₹4.1 L
EMD Value
₹8,180
Closing Date
21 Mar 2024, 5:00 pmClosed
Executive Engineer Horticulture Division Gurugram
Executive Engineer Horticulture Division Gurugram
DEVELOPMENT OF LANDSCAPING WORK OF FOOTBALL STADIUM AT SPORTS COMPLEX SEC-12 FARIDABAD.).
2024_HRY_366928_1
EE/HORT/PWD/Gurugram
Open Tender
Miscellaneous Goods
Tender
60 days
Gurugram
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
₹8,180
Yes
18 Mar 2025
11 Mar 2024
22 Mar 2024
11 Mar 2024
21 Mar 2024
11 Mar 2024
Amount
Maintenance of fine grass lawn for One Month including fertilizer application, DAP @ 20gm/sqm, urea 40gm/sqm, watering, weeding, top dressing with good earth and manure mixture 2:1 @ 0.01cum per sqm, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads (HSR 26.10 ).
Installation of 3HP Submersibel pump. Installation of Submersible Tubewell Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. All types of soil 300 mm dia (HSR 33.6.1.1)
Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia (HSR 33.8.2)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 50 mm dia nominal bore (HSR 22.88.6)
Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 1.5 sqmm (HSR 24.5.1.2)
Supply and lowering ISI Mark 3 HP single phase Submersible motor with pump of Lubi, KSB, Crompton, Texmo etc (along with Nylon rope) (NS)
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia (HSR 33.16.2)
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp (HSR 33.17.2)
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 150 mm dia (HSR 33.18)
Providing and fixing gun metal non- return valve of approved quality (screwed end): 50 mm nominal bore Horizontal (HSR 22.99.4.1)
Supply and fixing ISI mark panel board of 3 hp of BCH, Cuttler Hammer, L&T, Boparai etc. with Lock & Key Steel Box (NS)
Supply and fixing of 16 mm aluminium cable of R.R./Havells/Fenolux make. (NS)
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V'' notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (HSR 33.19)
The Gaur Co-Operative Multi Purpose Society Ltd. (BID ID -1072090)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .